Letter Sequence Other |
---|
|
|
MONTHYEARML0129104202002-01-0808 January 2002 Clarification of Leakage Inspection (Tac No. MB1065) Project stage: Other ML0228300432002-10-0909 October 2002 Current TAC List Project stage: Other ML0229101492002-10-18018 October 2002 Relief, Alternative Repair of Control Rod Drive Housing Interface with Reactor Vessel. TAC MB5700 Project stage: Other ML0330104342003-10-21021 October 2003 Alternative Repair of Control Rod Drive Housing Interface with Reactor Vessel Project stage: Other ML0617704772006-06-23023 June 2006 Oyster Creek, Response to Request for Additional Information - Proposed Alternative Repair of Control Rod Drive Housing Interface with Reactor Vessel Project stage: Response to RAI ML0622604182006-08-14014 August 2006 Response to Request for Additional Information - Proposed Alternative Repair of Control Rod Drive Housing Interface with Reactor Vessel Project stage: Response to RAI 2002-10-09
[Table View] |
|
---|
Category:Letter
MONTHYEARML23342A1162024-01-0909 January 2024 Independent Spent Fuel Storage Installation Security Inspection Plan L-23-019, Proof of Financial Protection 10 CFR 140.152023-12-18018 December 2023 Proof of Financial Protection 10 CFR 140.15 IR 05000219/20230022023-11-0909 November 2023 EA-23-076 Oyster Creek Nuclear Generating Station - Notice of Violation and Proposed Imposition of Civil Penalty - $43,750 - NRC Inspection Report No. 05000219/2023002 ML23286A1552023-10-13013 October 2023 Defueled Safety Analysis Report (DSAR) ML23249A1212023-09-0606 September 2023 NRC Inspection Report 05000219/2023002, Apparent Violation (EA-23-076) ML23242A1162023-08-30030 August 2023 Biennial 10 CFR 50.59 and 10 CFR 72.48 Change Summary Report January 1, 2021 Through December 31, 2022 ML23214A2472023-08-22022 August 2023 NRC Inspection Report 05000219/2023002 IR 05000219/20230012023-05-31031 May 2023 NRC Inspection Report No. 05000219/2023001 IR 07200015/20234012023-05-16016 May 2023 NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2023401 ML23114A0912023-04-24024 April 2023 Annual Radioactive Effluent Release Report for 2022 ML23114A0872023-04-24024 April 2023 Annual Radioactive Environmental Operating Report for 2022 L-23-004, HDI Annual Occupational Radiation Exposure Data Reports - 20222023-04-24024 April 2023 HDI Annual Occupational Radiation Exposure Data Reports - 2022 L-23-003, Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations2023-03-31031 March 2023 Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations ML23088A0382023-03-29029 March 2023 Stations 1, 2, & 3, Palisades Nuclear Plant, and Big Rock Point - Nuclear Onsite Property Damage Insurance ML22361A1022023-02-24024 February 2023 Reactor Decommissioning Branch Project Management Changes for Some Decommissioning Facilities and Establishment of Backup Project Manager for All Decommissioning Facilities IR 05000219/20220022023-02-0909 February 2023 NRC Inspection Report No. 05000219/2022002 ML23031A3012023-02-0808 February 2023 Discontinuation of Radiological Effluent Monitoring Location in the Sewerage System ML23033A5052023-02-0202 February 2023 First Use Notification of NRC Approved Cask RT-100 ML23025A0112023-01-24024 January 2023 LLRW Late Shipment Investigation Report Per 10 CFR 20, Appendix G ML22347A2732022-12-21021 December 2022 Independent Spent Fuel Storage Installation Security Inspection Plan Dated December 21, 2022 ML22297A1432022-12-15015 December 2022 Part 20 App G Exemption Letter L-22-042, Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.152022-12-14014 December 2022 Oyster, Pilgrim, Indian Point, Palisades and Big Rock Point - Proof of Financial Protection 10 CFR 140.15 IR 07200015/20224012022-12-0606 December 2022 NRC Independent Spent Fuel Storage Installation Security Inspection Report 07200015/2022401 (Letter & Enclosure 1) ML22280A0762022-11-0202 November 2022 Us NRC Analysis of Holtec Decommissioning Internationals Funding Status Report for Oyster Creek, Indian Point and Pilgrim Nuclear Power Station ML22276A1762022-10-24024 October 2022 Decommissioning International Proposed Revisions to the Quality Assurance Program Approval Forms for Radioactive Material Packages ML22286A1402022-10-13013 October 2022 NRC Confirmatory Order EA-21-041 IR 05000219/20220012022-08-11011 August 2022 NRC Inspection Report 05000219/2022001 ML22215A1772022-08-0303 August 2022 Decommissioning International (HDI) Proposed Revisions to the Quality Assurance Program Approval Forms for Radioactive Material Packages ML22214A1732022-08-0202 August 2022 Request for Exemption from 10 CFR 20, Appendix G, Section Iii.E ML22207B8382022-07-26026 July 2022 NRC Confirmatory Order EA-21-041 ML22130A6882022-05-10010 May 2022 Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G L-22-026, Occupational Radiation Exposure Data Report - 20212022-04-29029 April 2022 Occupational Radiation Exposure Data Report - 2021 ML22118A6122022-04-28028 April 2022 Annual Radioactive Environmental Operating Report for 2021 ML22118A5822022-04-28028 April 2022 Annual Radioactive Effluent Release Report for 2021 ML22091A1062022-04-0101 April 2022 Nuclear Onsite Property Damage Insurance (10 CFR 50.54(w)(3)) L-22-022, and Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations - Holtec.2022-03-25025 March 2022 and Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations - Holtec. ML22069A3762022-03-10010 March 2022 Late LLRW Shipment Investigation Report Pursuant to 10 CFR 20, Appendix G ML22032A0582022-03-0808 March 2022 EA-21-139; EA-150: Oyster Creek Nuclear Generating Station - NRC Investigation Report Nos.. 1-2021-002 & 1-2021-014 ML22060A2202022-03-0202 March 2022 NRC Office of Investigations Case No. 1-2021-009 ML22049B2452022-02-19019 February 2022 Late Low Level Radwaste Shipment Report Pursuant to 10 CFR 20 Appendix G IR 05000219/20214022022-01-26026 January 2022 EA-21-041: Confirmatory Order Related to Oyster Greek Nuclear Generating Station - NRC Investigation Report I-2020-007; NRC Inspection Report Nos. 05000219/2021402 & 07200015/2021401 ML22025A3422022-01-25025 January 2022 and Big Rock Point - Changes to Site Organization ML22025A2182022-01-25025 January 2022 Late LLRW Shipments Investigation Report Pursuant to 10 CFR 20, Appendix G ML22021B5512022-01-21021 January 2022 Compensatory Measures Not Implemented Per Site'S Physical Security Plan Due to Multiplexer (Mux) Power Supply Failure L-21-134, and Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Independent Spent Fuel Storage Installations2021-12-17017 December 2021 and Indian Point Nuclear Generating Stations 1, 2, & 3 - Report on Status of Decommissioning Funding for Independent Spent Fuel Storage Installations ML21349A5192021-12-15015 December 2021 Commitment Change Summary Report ML21285A1912021-11-30030 November 2021 Nrc'S Analysis of Holtec Decommissioning International'S Decommissioning Funding Status Report for Oyster Creek Nuclear Generating Station and Pilgrim Nuclear Power Station, Docket Nos 50-219 and 50-293 IR 05000219/20210032021-11-16016 November 2021 NRC Inspection Report No. 05000219/2021003 L-21-118, Changes to Signature Authority & Addressee for Holtec Decommissioning International, LLC Correspondence Re to Oyster Creek Nuclear Generating Station, Pilgrim Nuclear Power Station, Indian Point Nuclear Generating Units 1, 2, 3, & Palisades2021-11-0909 November 2021 Changes to Signature Authority & Addressee for Holtec Decommissioning International, LLC Correspondence Re to Oyster Creek Nuclear Generating Station, Pilgrim Nuclear Power Station, Indian Point Nuclear Generating Units 1, 2, 3, & Palisades IR 05000219/20214042021-08-26026 August 2021 NRC Independent Spent Fuel Storage Security Inspection Report No. 07200015/2021402 and Security Decommissioning Inspection Report 05000219/2021404 - (Public) 2024-01-09
[Table view] |
Text
January 8, 2002 Mr. Oliver D. Kingsley, President and Chief Nuclear Officer Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
OYSTER CREEK NUCLEAR GENERATING STATION - CLARIFICATION OF LEAKAGE INSPECTION (TAC NO. MB1065)
Dear Mr. Kingsley:
On November 10, 2000, AmerGen Energy Company, LLC (AmerGen) requested the U.S.
Nuclear Regulatory Commission (NRC) approval of an alternative repair to two leaking control rod drive (CRD) housings. This request was based on the guidance contained in the BWRVIP-17 report, Roll/Expansion Repair of Control Rod Drive and In-Core Instrumentation Penetrations in BWR Vessels. Although this report has not been approved for generic use by the Boiling Water Reactor (BWR) licensees, it has been used as a basis of plant-specific repairs. On November 16, 2000, the NRC staff approved this request.
By letter dated January 19, 2001, AmerGen clarified the conditions under which the leakage inspections for the control rod drive (CRD) housings will be initiated and what limits should apply. Part of the alternative repair was to follow page 7 in the section entitled, Penetration Leakage Acceptance Limits contained in the BWRVIP-17 report.
The CRD housing leakage limits specified in BWRVIP-17 are dependent upon the length of the outage when the leakage inspections are performed. Certain leakage limits apply when the outage is less than 7 days (Table 2-3). Other leakage limits apply when the outage is greater than 7 days (Table 2-4). Because the tables do not address what limits should apply if the outage is planned for a nominal duration of 7 days, AmerGen will apply the leakage limits of Table 2-3 if the planned outage duration is 7 days or less. The heading on Table 2-3 in BWRVIP-17 refers to leakage limits for inspections during forced outages of less than 7 days.
AmerGen believes that the leakage limits in Table 2-3 should apply to inspections during outages of opportunity of 7 days or less whether they are scheduled or forced. Also, the leakage limits of Table 2-3 would still remain applicable if a scheduled or forced outage is initially planned for 7 days or less and is subsequently extended due to unforseen or emerging circumstances.
AmerGen intends to perform the CRD housing leakage inspection only if there is a need to enter the drywell during a planned or forced outage regardless of expected outage length, in order to reduce occupational dose.
O. D. Kingsley The NRC staff has reviewed these notes of clarification and believes that they meet the intent of the BWRVIP-17 guidance. Therefore, the NRC staff has no objection to these points of clarification.
Sincerely,
/RA/
Helen N. Pastis, Senior Project Manager, Section 1 Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-219 cc: See next page
ML012910420 OFFICE PD1-1/PM PD1-1/SL BC:EMCB OGC PD1-1 (A)
NAME HPastis:as SLittle WBateman AHodgdon LRaghavan DATE 11/7/01 11/5/01 12/17/2001 12/27/2001 1/8/02 Oyster Creek Nuclear Generating Station cc:
John Skolds Kent Tosch, Chief Chief Operating Officer New Jersey Department of Exelon Generation Company, LLC Environmental Protection 4300 Winfield Road Bureau of Nuclear Engineering Warrenville, IL 60555 CN 415 Trenton, NJ 08625 William Bohkle Senior Vice President Nuclear Services Michael P. Gallagher Exelon Generation Company, LLC Director - Licensing 4300 Winfield Road Exelon Generation Company, LLC Warrenville, IL 60555 Correspondence Control Desk P.O. Box 160 John B. Cotton Kennett Square, PA 19348 Senior Vice President - Operations Support Exelon Generation Company, LLC Ernest J. Harkness 4300 Winfield Road Plant Manager Warrenville, IL 60555 Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC Joseph J. Hagan P.O. Box 388 Senior Vice President - Forked River, NJ 08731 Mid Atlantic Regional Operating Group Exelon Generation Company, LLC Kevin P. Gallen, Esquire 200 Exelon Way, Suite 305 Morgan, Lewis & Bockius LLP Kennett Square, PA 19348 1800 M Street, NW Washington, DC 20036-5869 Jeffrey A. Benjamin Vice President - Manager Regulatory Assurance Licensing and Regulatory Affairs Oyster Creek Nuclear Generating Station Exelon Generation Company, LLC AmerGen Energy Company, LLC 4300 Winfield Road P.O. Box 388 Warrenville, IL 60555 Forked River, NJ 08731 Ron J. DeGregorio Edward J. Cullen, Jr., Esquire Vice President Vice President, General Counsel and Oyster Creek Nuclear Generating Station Secretary AmerGen Energy Company, LLC Exelon Generation Company, LLC P.O. Box 388 300 Exelon Way Forked River, NJ 08731 Kennett Square, PA 19348 H. J. Miller J. Rogge, Region I Regional Administrator, Region I U. S. Nuclear Regulatory Commission U.S. Nuclear Regulatory Commission 475 Allendale Road 475 Allendale Road King of Prussia, PA 19406-1415 King of Prussia, PA 19406-1415 Mayor Lacey Township 818 West Lacey Road Forked River, NJ 08731 Senior Resident Inspector (Oyster Creek)
U.S. Nuclear Regulatory Commission P.O. Box 445 Forked River, NJ 08731