ML012050098

From kanterella
Jump to navigation Jump to search

Storage License Amendment Request for Fuelsolutions System Response to Request for Additional Information (TAC No. L23296)
ML012050098
Person / Time
Site: 07201026
Issue date: 07/16/2001
From: Quinn R
BNFL Fuel Solutions Corp
To:
Office of Nuclear Material Safety and Safeguards
References
-RFPFR, BFS/NRC-01-011, CMPC.0006.2, TAC L23296
Download: ML012050098 (38)


Text

-'- /602-G BNFL Fuel Solutions Corporation BNFL 3600 Glen Canyon Road Scotts Valley, CA 95066 Fuel Solutions Tel: (831) 438-6444 Fax: (831) 438-5206 July 16, 2001 BFS/NRC-01-011 Docket No. 72-1026 File No. CMPC.0006.2 Director, Office of Nuclear Material Safety and Safeguards United States Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Storage License Amendment Request for the FuelSolutionsTM System Response to Request for Additional Information (TAC No. L23296)

Reference:

Letter from USNRC to BNFL Fuel Solutions, "Request for Additional Information for the FuelSolutionsTM Spent Fuel Management System Amendment," dated May 18, 2001

Dear Sir or Madam:

This letter transmits the responses to the request for additional information (RAI) (provided via the reference letter) on the storage license amendment request (LAR) for the FuelSolutionsTM W74 Canister (LAR 01-02). This LAR requests certain specific changes to the FuelSolutionsTM W74 Canister Technical Specifications related to the storage and transfer of the W74 Canister, and has been revised to respond to requests made in the RAI. A summary of the changes and the bases for the changes are provided in the Summary of Changes included in the revised LAR.

The RAI responses and additional clarifications are attached. Enclosed are 10 copies of Revision 1 of the LAR, including the Summary of Changes, change pages to the FSAR Chapter 4, and change pages to the Technical Specifications and associated Bases. Also enclosed is a copy of supporting calculation CMPC. 1505.400 Revision 5.

The enclosed calculation contains commercial strategic information proprietary to BFS and customarily held in confidence. In conformance with 10 CFR Section 2.790, an affidavit is enclosed, setting forth the basis on which the identified proprietary information may be withheld from public disclosure. Accordingly, it is respectfully requested that the subject information, which is proprietary to BFS, be withheld from public disclosure in accordance with 10 CFR Section 2.790 of the Commission's regulations.

U.S. Nuclear Regulatory Commission BFS/NRC-01-011 Page 2 Should you or any member of your staff have any questions, please contact the undersigned at (831) 430-5220.

Sincerely)

Robert D. Quinn, P.E.

Manager of Operations Attachments Enclosures

1. LAR 01-02 Revision 1 (10 copies)
2. Affidavit pursuant to 10 CFR 2.790
3. Calculation CMPC.1505.400 Revision 5 (proprietary)

U.S. Nuclear Regulatory Commission BFS/NRC-01-011 Page 3 cc:

Mr. John Broschak Consumers Energy Palisades Nuclear Plant 27780 Blue Star Memorial Highway Covert, MI 49043 Mr. Michael Bourassa Consumers Energy Big Rock Point Plant 10269 US 31 North Charlevoix, MI 49720 Mr. Norio Hiyama IHI 1341 Beulah Road Bldg. 401-2B3 Pittsburgh, PA 15235 BFS/NRC 01-011 Responses to Request for Additional Information for FuelSolutions T M LAR 01-02 Chapter 12 - Operating Controls and Limits 12-1 For LCO 3.3.2 and LCO 3.3.3, provide analyses and/or test results that demonstrate that a canister may be kept in the transfer cask for an indefinite period of time.

Both of these requests propose changing "return CANISTER to the fuel building and remove all fuel assemblies" to "Return CANISTER to the TRANSFER CASK" without any restrictions on the length of time the canister can remain in the transfer cask, hence making the transfer cask a "de facto" storage cask.

Calculation Package No. CMPC.1505.400, Revision 4, Table 6-12 indicates that the maximum allowable fuel cladding temperature ("long term") is exceeded for normal transfer and normal hot transfer scenarios.

Regulatory Basis: 10 CFR 72.236(f) requires that storage casks must be designed to provide adequate heat removal capacity without active cooling systems.

BFS Response to 12-1 BFS has revised Calculation Package CMPC. 1504.400 to calculate the temperatures for the W74 canister heat load limit of 24.8 kW. The resulting temperatures demonstrate that the BRP canister can be placed into the transfer cask under steady state conditions and maintain temperatures within acceptable values, including maintaining cladding temperatures for normal transfer and normal hot transfer conditions below the long term cladding allowable temperature. Also, it should be noted that the peak cladding temperature for the off-normal hot transfer condition for the canister inside the transfer cask (388.7°C) is bounded by that for the canister inside the storage cask (395.8°C).

Therefore, it is demonstrated that a W74 canister loaded with BRP design basis fuel can be placed into the transfer cask for an indefinite period of time while satisfying the applicable long term cladding temperature limits for storage. Table 4.4-6 of the W74 FSAR has been revised accordingly Note that it is not intended that the transfer cask be used as a "de facto" storage cask. As such, a final action to return the canister to the storage cask has been added to the required actions for LCO 3.3.2 and 3.3.3 (see response to RAI 12-2 below).

Page 1 of 3 BFS/NRC 01-011 Responses to Request for Additional Information for FuelSolutions TM LAR 01-02 12-2 For LCO 3.3.2 and LCO 3.3.3, provide examples of compensatory measures that will be available to address system problems during canister storage in the transfer cask "long term" or provide justification why these measures are not necessary.

The change request does not state what alternative measures will be available to handle a problem with the transfer cask / canister system after the spent fuel pool is decommissioned, nor does the request state why such measures are not necessary.

Regulatory Basis: 10 CFR 72.122(b)(2)(ii) requires that the design bases for structures, systems, and components must reflect "appropriate combinations of the effects of normal and accident conditions and the effects of natural phenomena."

BFS Response to 12-2 There are no anticipated problems with temporary storage of the canister in the transfer cask. The cask will be secured in the horizontal position in an appropriate location by the licensee, with a cask centerline height not exceeding 108 inches and a support base at least 131 inches wide (consistent with the licensing basis in FSAR Chapter 3), such as provided by the skid/trailer system. Further, as discussed in response to RAI 12-1 above, the long-term storage thermal limits are satisfied for the canister in the transfer cask for normal and off normal conditions. For accident and natural phenomena, the canister and transfer cask have been evaluated for the effects of loss of neutron shield and side drop accidents, and fire, tornado wind and missile, and earthquake. The transfer cask has been demonstrated to provide adequate protection of the canister for all of these events.

Further, the transfer cask side drop evaluation bounds the effect of any tip over of the transfer cask on the skid and trailer, and as such the effects of flood velocity are bounded.

The canister is evaluated for the external pressure due to the postulated flood and shown to be adequate (see Section 3.7.7 of the W74 FSAR). The licensee will address the storage of the canister in the transfer cask in their 72.212 evaluation for site-specific conditions, and will provide supplemental shielding as required to satisfy ALARA, ISFSI, and site boundary dose limits. Thus there is no event which would lead to a problem with the transfer cask / canister system during temporary storage in the transfer cask.

To provide further margin against the occurrence of an unforeseen circumstance, an additional Required Action has been added to LCO 3.3.2 and LCO 3.3.3. Specifically, B.3 of LCO 3.3.2 and C.2 of LCO 3.3.3 have been added with the Action: "Return CANISTER to repaired or replacement STORAGE CASK," and Completion Time:

"270 days." The Bases are also modified accordingly.

Page 2 of 3 BFS/NRC 01-011 Responses to Request for Additional Information for FuelSolutions TM LAR 01-02 12-3 In TS 2.1.1, Fuel to be Stored in the FuelSolutions TM W74 canister, provide additional clarification and details in what is meant by "any other non-fissile material object."

In accordance with 10 CFR 72.2, only power reactor spent fuel and other radioactive materials associated with spent fuel storage are authorized to be stored in a canister.

BFS Response to 12-3 The terminology "any other non-fissile material object" was intended to include any fuel assembly related item that displaces less water than a fuel rod. It was not intended to permit storage of any material not associated with the spent fuel assembly hardware. To clarify the intent, the terminology of TS 2.1.1, Table 2.1-3 (paragraph 2, 2nd sentence) is modified to read, "...or stainless steel rods, neutron source rods, or any similar non-fissile fuel assembly component that displaces less water... " This clarifying sentence has also been added to Table 2.1-4 (paragraph 1, 3rd sentence).

Page 3 of 3 BFS/NRC 01-011 Additional Clarifications for FuelSolutions TM LAR 01-02 Revision of Change to LCO 3.3.2 Related to Thermocouple Call Out and Associated Temperature LAR 01-01 included changes to LCO 3.3.2, specifically changing the reference to the thermocouple used for temperature monitoring from the liner thermocouple to the cask (i.e. mid wall) thermocouple. This change was made to be consistent with the value that was specified in the LCO, which is the cask concrete mid-wall temperature as reported in FSAR Section 4.4, Table 4.4-2, Table 4.4-3 and Table 4.5-1. However, as noted in Section 2.4.3.2 of the Storage System FSAR, "the liner thermocouple is used to directly monitor concrete temperatures during dry storage. The mid-thickness thermocouple provides additional concrete temperature monitoring capability, should it be necessary. The technical specifications for monitoring cask temperatures using the liner thermocouple are contained in Section 12.3 of this FSAR."

While it is technically adequate to use the mid-wall thermocouple temperature to monitor cask thermal performance, the liner thermocouple will react more quickly to changes in thermal conditions. Thus, it is appropriate to change LCO 3.3.2 to indicate that the liner thermocouple should be used (as originally indicated) and change the temperatures to match that at the liner location. Thus, LCO 3.3.2 is revised to read, "The temperature of a STORAGE CASK with a W74 CANISTER containing fuel assemblies, as indicated by the liner thermocouple, shall meet the following limits: (a) The measured temperature shall not exceed 163°F (73°C) under normal ambient conditions (average ambient temperature up to 100'F (38'C)); (b) The measured temperature shall not exceed 192'F (89'C) under off-normal ambient conditions (average ambient temperature up to 125'F (52QC))."

Also, Section 4.4.1.10 and Tables 4.4-2, 4.4-3 and 4.5-1 of the W74 FSAR are revised to report the liner thermocouple temperature. For consistency with these revised tables, FSAR Table 4.6-1 has been editorially revised to call out the liner thermocouple. SR 3.3.3.1 of LCO 3.3.3 has also been editorially revised for clarity and consistency.

Page 1 of 1

AFFIDAVIT PURSUANT TO 10 CFR 2.790 State of California

)

)

SS.

County of Santa Cruz

)

I, Robert D. Quinn, depose and say as follows:

(1)

I am Manager of Operations of BNFL Fuel Solutions Corporation (BFS), and have been delegated the function of reviewing the information described in paragraph (2) which is sought to be withheld, and have been duly authorized to apply for its withholding.

(2)

The information sought to be withheld is contained in calculation CMPC. 1505.400.

This document has been appropriately designated as proprietary.

(3)

I have personal knowledge of the criteria and procedures used by BFS in designating information as trade secret, privileged, or as confidential commercial or financial information.

(4)

Pursuant to the provisions of paragraph (b)(4) of 10 CFR 2.790, the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure, including the information as designated in paragraph (2) above, should be withheld.

(i)

The information sought to be withheld from public disclosure is included in the report documenting information regarding nuclear fuel design, properties, and data which is owned and has been held in confidence by BFS.

(ii)

The information of a type customarily held in confidence by BFS and not customarily disclosed to the public. BFS has a rational basis for determining the types of information customarily held in confidence by it and, in that connection, utilizes a system to determine when and whether to hold certain types of information in confidence. The application of that system and the substance of that system constitutes BFS policy and provides the rational basis required.

Page 1 of 4

Under that system, information is held in confidence if it falls in one or more of several types, the release of which might result in the loss of an existing or potential competitive advantage, as follows:

a.

The information reveals the distinguishing aspects of a process or component, structure, tool, method, etc., and the prevention of its use by BFS' competitors, without license from BFS, gives BFS a competitive economic advantage.

b.

The information consists of supporting data (including test data) relative to a process or component, structure, tool, method, etc. and gives BFS a competitive economic advantage, e.g., by optimization or improved marketability.

c.

The information, if used by a competitor, would reduce the competitor's expenditure of resources or improve the competitor's advantage in the design, manufacture, shipment, installation, assurance of quality, or licensing of a similar product.

d.

The information reveals cost or price information, production capacities, budget levels, or commercial strategies of BFS, its customers or suppliers.

e.

The information reveals aspects of past, present, or future BFS or customer funded development plans and programs of potential commercial value to BFS.

f.

The information contains patentable ideas, for which patent protection may be desirable.

(iii)

The information is being transmitted to the Commission in confidence and, under the provisions of 10 CFR Section 2.790, it is to be received in confidence by the Commission.

Page 2 of 4

(iv)

The information sought to be protected is not available in public sources or available information has not been previously employed in the same original manner or method to the best of our knowledge and belief.

(v)

The proprietary information sought to be withheld in this submittal is that which is appropriately marked and being transmitted by BFS to the Document Control Desk. The proprietary information has been presented to the Nuclear Regulatory Commission and is being voluntarily provided by BFS.

(vi)

Public disclosure of the information is likely to cause substantial harm to the competitive position of BFS because:

(i)

Similar products are manufactured and sold by competitors of BFS.

(ii)

The development of this information by BFS is the result of a significant expenditure of staff effort and a considerable sum of money. To the best of my knowledge and belief, a competitor would have to undergo similar effort and expense in generating equivalent information.

(iii)

In order to acquire such information, a competitor would also require considerable time and inconvenience related to the development of a design of a canister-based spent fuel storage and transportation system.

(iv)

The information consists of design, analysis and fabrication of a transportable spent fuel storage system, the application of which provides a competitive economic advantage. The availability of such information to competitors would enable them to modify their product to better compete with BFS, take marketing or other actions to improve their product's position or impair the position of BFS' product, and avoid developing fabrication data in support of their processes, methods, and/or apparatus.

(v)

In pricing BFS' products and services, significant research, development, engineering, analytical, licensing, fabrication, quality assurance and other costs must be included. The ability of BFS' competitors to utilize such Page 3 of 4

information without similar expenditure of resources may enable them to sell their product at prices reflecting significantly lower costs.

Further the deponent sayeth not.

Robert D. Quinn Manager of Operations BNFL Fuel Solutions Corporation Subscribed and sworn before me this.(*ok day of

,2001.

Notary Public Comm. 11244720 NOTARY PUBLIC-CALIFORNIA U)

Santa Cruz County

  • ~MyComm.Expires Dec. 5, 2003 Page 4 of 4

FUEL!O0JUTIONS Fue1Solutions'm Storage System License Amendment Request LAR 01-02, Revision 1 July 2001 C of C

Reference:

WSNF-203 System Docket No. 72-1026 Prepared by:

BNFL Fuel Solutions Corporation Scotts Valley, California

@2001 BNFL Fuel Solutions Corporation All Rights Reserved

FuelSolutionsTM Storage System Docket No. 72-1026 Document No. LAR 0 1-02 July 2001 TABLE OF CONTENTS Item Tab Summ ary of Changes.........................................................................................................................

1 W 74 FSAR Change Pages.........................................................................................................

2 Technical Specification Change Pages.............................................................................................

3 Bases Change Pages..........................................................................................................................

4 Fe SiM ons ii Revision 1

FuelSolutionsTM Storage System Docket No. 72-1026 Document No. LAR 01-02 July 2001 Tab I Summary of Changes

  • BN.lSotn
  • Fuei Slutions Rvso Revision I

FuelSolutionsTM Storage System Docket No. 72-1026 Document No. LAR 0 1-02 July 2001 FuelSolutionsTM Spent Fuel Storage System C of C Number 72-1026 LAR 01-02, Revision I Summary of Changes (3 pages)

OBNFL.

SIFuel Soiutlons Revision I Item Section Description I

Basis 1

4.4.1.10, Change the temperature to This is an editorial correction to use the lower last para.

correspond to the value for temperature limit associated with the limiting heat the limiting 24.8 kW heat load for the W74 canister.

load.

2 Table 4.4-2 Change the temperatures Per Section 2.4.3.2 of the Storage System Table 4.4-3 reported for Cask FSAR, the liner thermocouple is to be used to Table 4.5-1 Thermocouple to the Liner monitor concrete temperatures. The mid-wall Thermocouple temperatures.

temperatures were listed in the table and also used in LCO 3.3.2 (see Item 4).

3 Table 4.4-6 Revise the peak fuel rod This change provides a reporting of the peak cladding temperatures to fuel rod cladding temperatures consistent with correspond to the W74 other tables for normal and off-normal canister heat load limit of conditions, and shows that the cladding 24.8 kW.

temperatures in the transfer cask remain below the long term cladding allowable temperatures.

4 Table 4.6-1 Change the callout from This is an editorial correction to clarify the Cask Thermocouple to Liner location of the reported temperatures, consistent Thermocouple.

with the change in Item 2.

5 TS 2.1.1 Change the description of the This clarification is provided to assure other non-fissile material compliance with 10 CFR 72.2.

permitted to be in the fuel I assembly.

I

FuelSolutionsTM Storage System Docket No. 72-1026 Document No. LAR 01-02 July 2001 FuelSolutionsTM Spent Fuel Storage System C of C Number 72-1026 LAR 01-02, Revision 1 Summary of Changes (3 pages)

  • uBNFLui FdudlSltons Rvso Item [ Section Description I

Basis 6

LCO 3.3.2 In LCO 3.3.2, change the The mid-wall temperatures were incorrectly temperatures to correspond used in the LCO for normal and off-normal the liner thermocouple.

conditions. The purpose of this change is to correct the monitored temperature to correspond to the specified thermocouple location 7

LCO 3.3.2 Change required action B.2 The original Action was based on the availability from "Return CANISTER to of a spent fuel pool. This basis is not the fuel building and remove supportable for decommissioning facilities such all fuel assemblies" to as Big Rock Point. As such, it is proposed that "Return CANISTER to an alternative mitigating action be performed.

TRANSFER CASK." Add Retrieval of the canister into the transfer cask required action B.3, "Return provides an adequate mitigating action, as the CANISTER to repaired or transfer cask is shown in Chapter 4 of the replacement STORAGE FSAR to provide adequate cooling for the CASK" with a completion canister. As such, this mitigation precludes the time of 270 days.

need for a spent fuel pool. To assure that the canister is returned to a storage cask for continued long term storage, an action is added to require placing the canister into a repaired or replacement storage cask.

I Revision I

FuelSolutionsTM Storage System Docket No. 72-1026 Document No. LAR 01-02 July 2001 FuelSolutionsTM Spent Fuel Storage System C of C Number 72-1026 LAR 01-02, Revision 1 Summary of Changes (3 pages)

FuelNeutions Item Section T Description Basis 8

LCO 3.3.3 Change required action C. I See discussion under Item 7.

from "Return CANISTER to the fuel building and remove all fuel assemblies" to "Return CANISTER to TRANSFER CASK." Add required action C.2, "Return CANISTER to repaired or replacement STORAGE CASK" with a completion time of 270 days.

9 B3.3.2 Under ACTIONS, add The revised discussion reflects the revised

"-B3" after B1 and revise Action, as discussed under Item 7.

discussion in accordance with Item 7.

10 B3.3.3 Under ACTIONS, add The revised discussion reflects the revised

"-C2" after C I and revise Action, as discussed under Item 8.

discussion in accordance with Item 8.

Revision 1 I

I I

FuelSolutionsTM Storage System Docket No. 72-1026 Document No. LAR 01-02 July 2001 Tab 2 W74 FSAR Change Pages

  • BNFL.

Fuel Slutions Revision 1

FuelSolutionsTM W74 Canister Storage FSAR Document No. WSNF-223 Docket No. 72-1026 July 2001 The canister cavity helium pressure of 9.3 psig (24 psia) is conservatively assumed for heat transfer analyses under normal hot storage conditions. As discussed above, during canister closure operations, the canister is back-filled with helium in order to achieve 10 psig under normal hot storage conditions with 1% rod failures. The canister shell design, fabrication, inspection, and closure processes ensure that the canister does not leak as discussed in Section 7.1 of this FSAR. A helium loss at the allowable canister leak rate over the entire 100 year storage life does not significantly reduce the canister cavity pressure or adversely impact heat transfer.

4.4.1.9 Maximum Thermal Stresses FuelSolutionsTM W74 canister maximum thermal stresses developed within the storage cask under normal conditions are addressed in Chapter 3. Calculation of these thermal stresses is based on the maximum canister structure heat load of 26A kW, and is conservative (bounding) for the actual canister heat rating of 24.8 kW.

4.4.1.10 Evaluation of Canister Performance for Normal Conditions The results of the steady-state analyses demonstrate that the storage cask allowable material temperatures under normal conditions are met for the maximum canister thermal rating, as presented in Table 4.4-1. Over the long-term storage period the spent fuel decay heat decreases, thus increasing the margins relative to the allowable temperatures. Therefore, the W74 canister is suitable for the dry storage of Big Rock Point BWR fuel within the FuelSolutionsrm W150 Storage Cask.

Table 4.4-4 presents the summary of canister pressures for normal conditions of storage. As seen from the table, the canister pressurization for normal conditions of storage are within the design allowables.

The W74 canister heat balance under normal hot storage conditions and the maximum heat load rating (Qmax) is presented schematically in Figure 4.4-16. As can be seen, heat input to the storage cask is from spent fuel decay heat (26.4 kW, based on the canister structural heat load rating) and solar (3.03 kW on top, 2.86 kW on sides). Most of the heat is lost to natural convection air flow (24.46 kW) with the remaining heat lost through the storage cask to ambient through natural convection (1.45 kW for top, 2.16 kW from sides) and radiation (1.86 kW from top, 2.35 kW from sides).

The storage cask liner thermocouple reading (1 63'F) under normal hot storage conditions with the design basis W74 canister loaded is used as the basis for establishing the technical specification for normal daily temperature monitoring, contained in Section 12.3 of this FSAR.

Fuel Slut;ons 44-13

FuelSolutionsTM W74 Canister Storage FSAR Docket No. 72-1026 Document No. WSNF-223 July 2001 Table 4.4 W74 Canister Thermal Rating in Storage Cask Applicable Fuel Group Axial Heat Profile Qmax (kW)

LHGRmax (kWlin)

Big Rock Point Max Thermal 24.8 0.216 BWR Fuel Max Thermal Gradient N/A N/A Thermal Rating 24.8 0.216 W74 Canister Structure Thermal Rating 26.4 0.230 Storage Cask Thermal Rating 28.0 0.253 Table 4.4 W74 Canister System Temperature at Qmax in Storage Cask Component Component Maximum Maximum Max. Allowable Component Temperature Temperature Temperature (24.8 kW)

(26-4 kW)

Peak Fuel Rod Cladding 384.6 0C 399.80C 385.5 0C Guide Tube 690°F 716 0F 800°F Spacer Plates:

Stainless Steel 488°F 506°F 800°F Carbon Steel 6730F 6990F 700OF Engagement Plate 431 °F 4450F 800°F Support Tube 5630F 584 0F 800°F Helium Bulk 4950F 513OF N/A Canister Shell 431OF 4450F 800OF Max. Concrete 175 0F 176 0F 200°F Liner Thermocouple(')

163 0F 166 0F N/A Eimate

(') Estimated thermocouple reading for analyzed condition.

  • BNFL Revision 2 I

4.4-14

FuelSolutionsTM W74 Canister Storage FSAR Docket No. 72-1026 Document No. WSNF-223 July 2001 Table 4.4 Maximum W74 Canister System Temperature at Qmax for Storage(')

Notes:

(i)

Except as noted, temperatures are based on a heat load of 24.8 kW.

(2) Temperatures based on a heat load of 26.4 kW.

(3) Estimated thermocouple reading for analyzed condition.

(4)

Temperatures based on heat load of 28 kW.

Revision 2 Case 5 Case 6 Case 7 Normal Normal Cold Normal Hot Allowable Component StorageO

1)

Storage(2 Storage(')

Temperature Peak Fuel Rod 373.7 0C 353.2 0C 384.60C 385.5°C Cladding Guide Tube 668°F 6270F 690°F 800°F Spacer Plates:

Stainless Steel 4660F 408OF 488°F 800°F Carbon Steel 6520F 608°F 673 0F 700°F Engagement Plate 408°F 346 0F 431°F 800°F Support Tube 540°F 485 0F 563 0F 800°F Helium Bulk 4730F 415°F 4950F n/a Canister Shell 407°F 337 0F 431OF 800°F Max. Concrete 150°F 490F 175 0F 200°F Liner Thermocouple"3) 136 0F 41OF 163 0F n/a Reference Results From Table 4.4-7 of the FuelSolutionsTM Storage System FSAR 447"0F 1970"F 1790"F Liner I

I 4.4-15 FudSolutiorts

FuelSolutionsTM W74 Canister Storage FSAR Docket No. 72-1026 Document No. WSNF-223 July 2001 Table 4.4 W74 System Temperatures for Normal Transfer(1 )

Case 13 Case 14 Case 15 Normal Normal Cold Normal Hot Material Component Transfer Transfer Transfer Allowable(4)

Peak Fuel Rod 379.00 C 362.20C 383.6C 400 0C Cladding(6)

Guide Tube 705OF 673 0F 714OF 800°F Spacer Plates:

Stainless Steel 6520F 617OF 661 OF 800°F Carbon Steel 6930F 658 0F 700OF 700°F Engagement Plate 4960F 4590F 506OF 800°F Support Tube 6740F 641°F 6830F 800OF Helium Bulk Temp.

581°F 544 0F 591OF n/a Canister Shell 5330F 4970F 543 0F 800°F Cask Inner Shell 3230F 2770F 336 0F 800OF Cask Lead Shield 319OF 2730F 332 0F 620°F Cask Outer Shell 2330F 172 0F 2490F 800°F Liquid Neutron Shield 216OF 154 0F 233 0F 2930F Neutron Shield 16.1 psia 14.6 psia 22.1 psia 60 psia(5)

Pressure Cask Thermocouple(2) 225-F 165 0F 2420F n/a Reference Results From Table 4.4-11 of the FuelSolutionsTM Storage System FSAR Cask Lead Shell(3) 332 OF 281 OF 345 OF Cask Thermocouple(2'3) 240°F 180°F 257 0F Notes:

(')

Except as noted, temperatures are based on a heat load of 26.4 kW.

(2)

Estimated thermocouple reading for analyzed condition.

(3) Temperatures based on heat load of 28 kW.

(4)

Canister allowable temperatures are from Table 4.3-1 of this FSAR. Transfer cask material allowable temperatures are from Table 4.3-2 of the FuelSolutionsTm Storage System FSAR.

(5) Neutron shield allowable pressure is from Table 2.0-1 of the FuelSolutionsTm Storage System FSAR.

(6)

Temperatures based on heat load of 24.8 kW.

  • DBNFL.44o Fuel Solutions 4.4-41 Revision 2

FuelSolutionsT M W74 Canister Storage FSAR Docket No. 72-1026 Document No. WSNF-223 July 2001 Table 4.5 Maximum W74 Canister System Temperature at Qmax for StorageI')

Case 8 Case 9 Case 13b02)

Horizontal Off-Normal Off-Normal Unloading, Material Component Cold Storage Hot Storage Initial/PeakO3)

Allowable4 Peak Fuel Rod Cladding 334.20C 395.80C(5) 389.5OC / 391.5 0C 400 0C Guide Tube 589°F 738OF 697 0F / 707OF 800/10000 F Spacer Plates:

Stainless Steel 3670F 529 0F 484°F / 623 0F 800/1000°F Carbon Steel 571 OF 721 OF 679 0F 698°F 700/1000°F Engagement Plate 305°F 4690F 4230F /422 0F 800/10000F Support Tube 4440F 608°F 562 0F /670°F 800/1000°F Helium Bulk 3750F 536 0F 491OF /563 0F n/a Canister Shell 291°F 471°F 422 0F 550°F 800/1000°F Max. Concrete 30F 208°F 153 0F /200°F 350OF Liner Thermocouple(6)

-5°F 192`F 139 0F/ 1850F n/a Reference Results From Tables 4.4-7 and 4.5-2 of FuelSolutionsTM Storage System FSAR Canister Shelf"7 290 OF 473 OF 423 OF / 662 OF Max. Concrete(7) 12 OF 228 OF 1690F/348OF Liner Thermocouple(6'7) 0 OF 210 0F 150OF/312OF Notes:

()

Except as noted, temperatures are based on a heat load of 26.4 kW.

(2)

Technical specification will prevent steady-state canister temperatures from occurring for case 13b (horizontal storage cask unloading).

(3> Peak temperatures taken from 9.5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> point in the transient analysis.

(4>

Short-term steel allowable temperatures apply for cases 8 and 9. Mitigating actions are required prior to exceeding long-term allowable temperatures for case 13b (see Section 12.3 of this FSAR). Canister allowable temperatures are from Table 4.3-1 of this FSAR. Storage cask material allowable temperatures are from Table 4.3-1 of the FuelSolutionsTm Storage System FSAR SPeak fuel cladding temperatures, and liner thermocouple temperature for Case 9, based on a canister heat load of 24.8 kW; all other canister component temperatures assume a heat load of 26.4 kW.

(6) Estimated thermocouple reading for analyzed condition.

(7) Temperatures based on heat load of 28 kW.

  • uNFLi
1. uýeilSoflutos 455Rvso 4.5-5 Revision 2

FuelSolutionsTM W74 Canister Storage FSAR Docket No. 72-1026 Document No. WSNF-223 July 2001 Table 4.6 W74 Canister System Temperature for All Vents Blocked(')

Case 11 Material Allowable Component All Vents Blocked, Initial/Peakl)

Temperature(5)

Peak Fuel Rod Cladding 389.50C / 506.30C 5700C Guide Tube 697 0F / 919°F 1000°F Spacer Plates:

Stainless Steel 484°F / 7240F I 000°F Carbon Steel 679 0F / 903OF 1 0000 F Engagement Plate 4230F / 6650F 1 000°F Support Tube 562 0F / 804°F 1000I F Helium Bulk 491OF / 7280F n/a Canister Shell 422 0F / 6850F 1000°F Max. Concrete 153 0F / 350°F 350°F Liner Thermocouple (3) 139 0F / 340°F n/a Reference Results From Table 4.4-7 and 4.6-2 of the FuelSolutionsTM Storage System FSAR Canister Shelf')

423 °F1644 °F Max. Concrete (4) 169 °F1349°F Liner Thermocoup le(3"'

15 0 °F13 34 OF Notes:

(1) Except as noted, temperatures are based on a heat load of 26.4 kW.

(2)

Peak temperature taken from the 58 hour6.712963e-4 days <br />0.0161 hours <br />9.589947e-5 weeks <br />2.2069e-5 months <br /> point in the transient analysis.

(3)

Estimated thermocouple reading for analyzed condition.

(4)

Temperatures based on heat load of 28 kW.

(5) Canister allowable temperatures are from Table 4.3-1 of this FSAR. Storage cask material allowable temperatures are from Table 4.3-1 of the FuelSolutionsTM Storage System FSAR.

Revision 2 4.6-7 Neuil-oluiairt

FuelSolutionsTM Storage System Docket No. 72-1026 Document No. LAR 0 1-02 July 2001 Tab 3 Technical Specification Change Pages Revision I WSoludons

Functional and Operating Limits 2.0 2.0 Functional and Operating Limits Table 2.1-3 FuelSolutionsTM W74 Loading Specification W74-3 W74-3 Payload Configuration Partial U0 2 Fuel Assemblies Parameter Limit/Specification Payload

Description:

Cladding Material/Condition:

Initial Enrichment(O):

Bumup:

Cooling Time:

< 64 Big Rock Point BWR partial U0 2 fuel assemblies, as defined in Table 2.1-7.

Partial fuel assemblies are defined as those assemblies having one or more rods missing from the design basis assembly array. The empty army locations may contain nothing, partial length rods, hollow zircaloy or stainless steel rods, neutron source rods, or any similar non-fissile fuel assembly component that displaces less water than a design fuel rod. Any remaining empty canister basket guide tubes and/or support tubes may be loaded with fuel assemblies meeting any of the acceptable loading specifications W74-1, W74-2, and W74-4 through W74-6, subject to the limitations of those specifications.

If less than 64 total fuel assemblies are loaded, a dummy fuel assembly shall be placed into each empty CANISTER basket guide tube. Each dummy fuel assembly shall be the approximate weight and size of the actual fuel being loaded.

Zircaloy cladding with no known or suspected cladding defects greater than hairline cracks or pinhole leaks.

3.55 w/o 235U (missing array interior or edge rods - 9x9) 3.6 w/o 235U (missing array interior or edge rods - 1 lx 1i)

< 40,000 MWd/MTU.

> 3.0 years. The minimum acceptable cooling time varies by fuel assembly class and enrichment, as a function of bumup; and is also dependent on the total cobalt content of the fuel and control components. The effects of the maximum acceptable decay heat, initial uranium content, and gamma and neutron sources are incorporated into the minimum cooling time determination. Fuel assemblies shall not be stored with less than the minimum acceptable cooling time indicated in Table 2.1-9.

Note: (')

Defined as lattice average enrichment.

FuelSolutionsTM W74 Canister Note: (o Defined as lattice average enrichment.

2.0-5 Amendment 2

Functional and Operating Limits 2.0 2.0 Functional and Operating Limits Table 2.1-4 FuelSolutions TM W74 Loading Specification W74-4 W74-4 Payload Configuration Partial MOX Fuel Assemblies Parameter Limit/Specification Payload

Description:

< 64 Big Rock Point BWR partial MOX fuel assemblies, as defined in Table 2.1-8. Partial fuel assemblies are defined as those assemblies having one or more rods missing from the design basis assembly array. The empty array locations may contain nothing, partial length rods, hollow zircaloy or stainless steel rods, neutron source rods, or any similar non-fissile fuel assembly component that displaces less water than a design fuel rod. Any remaining empty canister basket guide tubes and/or support tubes may be loaded with fuel assemblies meeting any of the acceptable loading specifications W74-1 through W74-3, W74-5, and W74-6, subject to the limitations of those specifications.

If less than 64 fuel assemblies are loaded, a dummy fuel assembly shall be placed into each empty CANISTER basket guide tube.

Each dummy fuel assembly shall be the approximate weight and size of the actual fuel being loaded.

Cladding Material/Condition:

Zircaloy cladding with no known or suspected cladding defects greater than hairline cracks or pinhole leaks.

Initial Enrichment:

See Table 2.1-8 Burnup:

See Table 2.1-8 Cooling Time:

See Table 2.1-8 FuelSolutionsTM W74 Canister 2.0-6 Amendment 2

Storage Cask Temperatures During Storage 3.3.2 3.3 STORAGE CASK INTEGRITY 3.3.2 Storage Cask Temperatures During Storage LCO 3.3.2 APPLICABILITY:

The temperature of a STORAGE CASK with a W74 CANISTER containing fuel assemblies, as indicated by the liner thermocouple, shall meet the following limits:

a.

The measured temperature shall not exceed 163'F (73°C) under normal ambient conditions (average ambient temperature up to 100-F (38-C)).

b.

The measured temperature shall not exceed 192°F (89'C) under off-normal ambient conditions (average ambient temperature up to 125°F (52'C)).

c.

The differential temperature between two successive daily measurements shall not exceed the corresponding differential ambient temperature plus 83°F (46°C).

During STORAGE OPERATIONS.

ACTIONS NOTE Separate Condition entry is allowed for each STORAGE CASK.

1COMPLETION CONDITION REQUIRED ACTION TIME A.

STORAGE CASK concrete A. 1 Administratively verify correct 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> temperature exceeds the fuel loading.

specified limit AND A.2 Visually check all STORAGE 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> CASK inlet and outlet screens for debris blockage in accordance with LCO 3.3.1.

AND A.3 Check the thermocouple and 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> related instumnentation to assure they are fimctioning properly.

ANJD (continued)

FuelSolutionsTm W74 Canister I

3.3 -2 Amendment 2

Storage Cask Temperatures During Storage 3.3.2 3.3.2 Storage Cask Temperatures During Storage COMPLETION CONDITION REQUIRED ACTION TIME A.4 Repair or replace thermocouple 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> and related instrumentation as necessary.

AND A.5 Perform visual inspection of the 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> STORAGE CASK vent channels by removing the debris screens and using visual aids as necessary. If no obstruction is found, the interior of the STORAGE CASK, including the guide rails and heat shield, is to be visually inspected for ventilation obstructions using remote inspection tools or by temporarily removing the STORAGE CASK top cover.

B.

Required Actions and B.1 Initiate actions to cool the cask 96 hours0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> associated Completion to within the limit.

Times are not met.

AND B.2 Return CANISTER to 30 days TRANSFER CASK.

AND B.3 Return CANISTER to 270 days repaired or replacement STORAGE CASK.

FuelSolutionsM W74 Canister 3-3 -3 Amendment 2

Storage Cask Temperatures During Storage 3.3.2 3.3.2 Storage Cask Temperatures During Storage SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.2.1 Verify that the STORAGE CASK temperatures are 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> within limit NOTE Daily cask temperatures can be expected to vary slightly due to changes in the ambient temperature. This is acceptable as long as the temperatures remain within the specified limit FuelSolutionsM W74 Canister 3.3-4 Amendment 2

Storage Cask Temperatures During Horizontal Transfer 3.3.3 3.3 STORAGE CASK INTEGRITY 3.3.3 Storage Cask Temperatures During Horizontal Transfer LCO 3.3.3 The measured temperature of a STORAGE CASK with a W74 CANISTER containing fuel assemblies, as indicated by the liner thermocouple, shall not exceed 185'F (85'C).

APPLICABILITY:

During TRANSFER OPERATIONS.

ACTIONS NOTE Separate Condition entry is allowed for each STORAGE CASK.

I I COMPLETION CONDITION REQUIRED ACTION TIME A.

STORAGE CASK concrete A.1 Transfer the CANISTER into 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> temperature limit is not met.

the TRANSFER CASK..

B.

Required Actions and B.1 Inspect the STORAGE 5 days associated Completion CASK for damage.

Times are not met.

B.2.1 If no damage, transfer 7 days CANISTER to STORAGE CASK.

OR B.2.2 If damaged, transfer 21 days CANISTER to new STORAGE CASK.

C.

Required Actions and C. I Return CANISTER to 30 days associated Completion TRANSFER CASK.

Time are not met.

AND B.3 Return CANISTER to 270 days repaired or replacement STORAGE CASK.

FuelSolutionsM W74 Canister 3.3-5 Amendment 2

Storage Cask Temperatures During Horizontal Transfer 3.3.3 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.3.1 After the STORAGE CASK is downended to the 30 minutes horizontal orientation, monitor and record STORAGE CASK concrete temperature as indicated by the STORAGE CASK liner thermocouple.

FuelSolutionsM W74 Canister Amendment 2 3.3 -6

FuelSolutionsTM Storage System Docket No. 72-1026 Document No. LAR 01-02 July 2001 Tab 4 Bases Change Pages Revision 1 Fuetl SOtions

Storage Cask Temperatures During Storage B 3.3.2 B 3.3 STORAGE CASK INTEGRITY B 3.3.2 Storage Cask Temperatures During Storage BASES BACKGROUND After placement on the ISFSI pad, the heat from the fuel assemblies within the CANISTER is removed by air flowing past the CANISTER, entering in the inlet vents and exiting through the outlet vents in the STORAGE CASK.

Monitoring of the STORAGE CASK concrete temperatures assures that the heat removal capability of the STORAGE CASK is not compromised.

APPLICABLE SAFETY The thermal analyses of the STORAGE CASK (Reference 1) and ANALYSIS CANISTERs (Reference 2) result in STORAGE CASK concrete temperatures that correspond to the design basis conditions and configuration. Monitoring of the STORAGE CASK concrete temperature assures that the long-term concrete and fuel assembly cladding temperatures remain within allowable values.

Temperatures not satisfying the limits may indicate a problem with the conditions or configuration which need to be corrected to maintain temperatures with acceptable values.

LCO The specified temperature limits assure that the long-term storage cask concrete and fuel assembly cladding temperatures remain within allowable values. This assures long-term integrity of the STORAGE CASK concrete and the fuel assembly cladding.

APPLICABILITY STORAGE CASK temperature monitoring is performed during STORAGE OPERATIONS.

ACTIONS A note has been added to the Actions stating that a separate Condition entry is allowed for each STORAGE CASK. This is acceptable since the Required Actions for each Condition provide appropriate compensatory measures for each STORAGE CASK not meeting the LCO. Subsequent STORAGE CASKs that do not meet the LCO are governed by subsequent Condition entry and application of associated Required Actions.

(continued)

FuelSolutionsTM W74 Canister B 3.3-2 Amendment 2

Storage Cask Temperatures During Storage B 3.3.2 BASES ACTIONS (continued)

A._I If the indicated concrete temperature is greater than any of the specified limits, or if the concrete temperature rise exceeds the specified limits, then it is required to confirm that the CANISTER has been loaded with SNF assemblies that comply with the Functional and Operating limits of Section 2.0 of the W74 CANISTER Technical Specification.

Administrative verification of the fuel loading, by means such as video recordings and records of the loaded fuel assembly serial numbers, can establish whether a misloaded fuel assembly is the cause of the out-of limit condition.

The Completion Time is sufficient to determine and correct most failure mechanisms.

A.2 All STORAGE CASK inlet and outlet vents and screens should be checked for debris blockage in accordance with LCO 3.3.2 of the FuelSolutionsTM Storage System Technical Specification.

The Completion Time is sufficient to determine and correct most failure mechanisms.

A.3 - A.4 Another possible cause of exceeding the temperature limits is equipment malfunction. The thermocouple and related instrumentation should be checked to assure they are functioning properly, and repaired or replaced as necessary.

The Completion Time is sufficient to determine and correct most failure mechanisms.

(continued)

FuelSolutionsg W74 Canister B 3.3-3 Amendment 2

Storage Cask Temperatures During Storage B 3.3.2 BASES ACTIONS (continued)

A.5 Another possible cause of temperatures exceeding the limits is obstruction inside the vents or the cask. Visual inspection of the STORAGE CASK vent channels is performed by removing the debris screens and using visual aids as necessary. If no obstruction is found, the interior of the STORAGE CASK, including the guide rails and heat shield, should be visually inspected for ventilation obstructions using remote inspection tools or by temporarily removing the STORAGE CASK top cover.

The Completion Time is sufficient to determine and correct most failure mechanisms.

B.1 - B.3 If the temperature cannot be successfully reduced to within the specified limits by the above actions, then mitigating actions must be taken to cool the STORAGE CASK within the limits until other measures can be employed. The CANISTER can be retrieved to the TRANSFER CASK (which has been evaluated to maintain acceptable temperatures under steady state conditions). The licensee will temporarily store the CANISTER in the TRANSFER CASK in a horizontal configuration bounded by that analyzed in the FSAR, and will provide any supplemental shielding which may be determined necessary as the result of a site-specific evaluation conducted in accordance with 10 CFR 72.212. The CANISTER will be returned to a repaired or replacement STORAGE CASK for continued long term storage. The Completion Times are reasonable based on the time required to establish cooling actions and place the CANISTER into the TRANSFER CASK, and to return CANISTER to a repaired or replacement STORAGE CASK, in an orderly manner without challenging personnel.

SURVEILLANCE SR 3.1.2.1 REQUIREMENTS The STORAGE CASK concrete temperatures are to be checked daily to provide adequate frequency to assure that temperatures remain within the specified limits and provide adequate time to initiate corrective actions.

REFERENCES

1. FuelSolutionsTM Storage System SAR, Section 4.4.
2.

FuelSolutionsM W74 Canister Storage SAR, Section 4.4.

FuelSolutionsM W74 Canister Amendment 2 B 3.3-4

Storage Cask Temperatures During Horizontal Transfer B 3.3.3 B 3.3 STORAGE CASK INTEGRITY B 3.3.3 Storage Cask Temperatures During Horizontal Transfer BASES BACKGROUND When a STORAGE CASK with a CANISTER containing fuel assemblies is in the horizontal orientation, the natural convective air flow that cools the CANISTER is altered. The STORAGE CASK thermocouple temperature is correlated through analysis to the maximum concrete temperature near the liner/concrete interface.

Assuring that the storage cask thermocouple temperature limit is not exceeded assures that the short-term allowable concrete temperature is not exceeded.

APPLICABLE SAFETY The basis for maintaining this STORAGE CASK temperature limit is ANALYSIS the thermal analysis contained in Chapter 4 of the Storage System SAR (Reference 1). The specified temperature limit is correlated to the short-term allowable concrete temperature.

LCO Limiting the concrete temperature during horizontal CANISTER TRANSFER OPERATIONS maintains the STORAGE CASK concrete temperatures within the design basis.

APPLICABILITY Temperature monitoring is performed during horizontal TRANSFER OPERATIONS.

ACTIONS A note has been added to the Actions stating that a separate Condition entry is allowed for each STORAGE CASK. This is acceptable since the Required Actions for each Condition provide appropriate compensatory measures for each STORAGE CASK not meeting the LCO. Subsequent STORAGE CASKs that do not meet the LCO are govemed by subsequent Condition entry and application of associated Required Actions.

AA.I If the STORAGE CASK concrete temperature limit is not met, then it is required to take action to reduce the STORAGE CASK concrete temperature. This may be accomplished by removing the CANISTER from the STORAGE CASK into the TRANSFER CASK.

The Completion Time is adequate to perform this task.

(continued)

FuelSolutionsTM W74 Canister B 3.3-5 Amendment 2

Storage Cask Temperature During Horizontal Transfer B 3.3.3 BASES ACTIONS (continued)

B.1 The STORAGE CASK should be inspected for signs of damage to the concrete. The Completion time is adequate to perform the inspection and assessment.

B.2.1 If the STORAGE CASK is undamaged, it may be reused. The Completion Time is reasonable based on the time to complete the TRANSFER OPERATIONS.

B.2.2 If the STORAGE CASK is damaged, then it may not be used. A new STORAGE CASK will be required to store the CANISTER. The Completion Time is reasonable based on the time to complete the TRANSFER OPERATIONS.

C.A - C.2 If the CANISTER cannot be placed into storage or retrieved from storage within the specified time, mitigating actions must be initiated.

The CANISTER can be retrieved to the TRANSFER CASK (which has been evaluated to maintain acceptable temperatures under steady state conditions). The licensee will temporarily store the CANISTER in the TRANSFER CASK in a horizontal configuration bounded by that analyzed in the FSAR, and will provide any supplemental shielding which may be determined necessary as the result of a site-specific evaluation conducted in accordance with 10 CFR 72.212. The CANISTER will be returned to a repaired or replacement STORAGE CASK for continued long term storage. The Completion Times are reasonable based on the time required to place the CANISTER into the TRANSFER CASK, and to return CANISTER to a repaired or replacement STORAGE CASK, in an orderly manner without challenging personnel.

SURVEILLANCE The STORAGE CASK concrete temperature is to be checked every REQUIREMENTS 30 minutes when the STORAGE CASK is in a horizontal orientation with a CANISTER containing fuel assemblies. The frequency of inspection assumes that temperatures remain within limits and provide adequate time to initiate corrective actions.

REFERENCES

1. FuelSolutionsM Storage System SAR, Section 4.5.

FuelSolutionsg W74 Canister B 3.3-6 Amendment 2