Tennessee Valley Authority, Post Office Box 2000, Spring City, Tennessee 37381-2000 M I 1 2001 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C.

20555 10 CFR 50, App E.

Gentlemen:

Docket No.

50-390 In the Matter of Tennessee Valley Authority WATTS BAR NUCLEAR PLANT (WBN)

EMERGENCY PLAN IMPLEMENTING PROCEDURE (EPIP) REVISION In accordance with the requirements of 10 CFR Part 50, Appendix E, Section V, the enclosure provides the EPIPs as listed below.

EPIP Rev Title Effective Date Notification of Unusual Event Alert Site Area Emergency General Emergency Activation and Operation of the Operations Support Center 4-25-2001 4-25-2001 4-25-2001 4-25-2001 4-25-2001 Pages 11A and 1IB for EPIP-l, revision 16, are being reissued.

These pages were issued as single pages (81/2 X 11) but should have been issued as a single fold out page (11 X 17).

Filing instructions are included with these documents.

c4 Pnnted on recyded paper EPIP-2 EPIP-3 EPIP-4 EPIP-5 EPIP-7 15 18 19 20 14

) )

U.S. Nuclear Regulatory Commission Page 2 MAY 11 2001 There are no regulatory commitments in this letter.

If you should have any questions, please contact me at (423) 365-1824.

Sincerely, P.. Pce

Manager, Licensing and Industry Affairs Enclosure cc (Enclosure)

NRC Resident Inspector (w/o Enclosure)

Watts Bar Nuclear Plant 1260 Nuclear Plant Road Spring City, Tennessee 37381 Mr.

L. Mark Padovan, Senior Project Manager U.S. Nuclear Regulatory Commission MS 08G9 One White Flint North 11555 Rockville Pike Rockville, Maryland 20852 U.S. Nuclear Regulatory Commission (2 copies)

Region II Atlanta Federal Center 61 Forsyth St.,

SW, Suite 23T85 Atlanta, Georgia 30303

U.S. Nuclear Regulatory Commission Page 3 PLP:JES Enclosure cc (w/o Enclosure):

T.

L. Adams, ADM 1V-WBN R. J.

Adney, LP 6A-C J. A. Bailey, LP 6A-C D. K.
Baker, BR 3H-C J. E.
Baker, WTC G-WBN L. S.
Bryant, MOB 2R-WBN M. J.

Burzynski, BR 4X-C C. C.

Cross, LP 6A-C M. H. Dunn, ET 10A-K J. E.
Maddox, EQB lA-WBN NSRB Support, LP 5M-C L.

V.

Parscale, ADM 1B-WBN F.

L. Pavlechko, WTC 1P-WBN J.

A. Scalice, LP 6A-C K.

W. Singer, LP 6A-C R.

J.

Vander Grift, EQB 2W-WBN J.

A. West, MOB 2R-WBN Sequoyah Licensing Files, OPS 4C-SQN

EDMS, WT 3B-K S :\\SITELIC\\SHARED\\LROUSE\\SUBMIT\\EPIP052001

. DOC

FILING INSTRUCTIONS EPIP-1 pages 11A & llB (8 1/2z x 11) pages 11A & llB (11 x 17 foldout)

Remove Insert

FEPIPI

]

Rpevision 16 IIPane 11A of 49 I

FEWIP SRevision 16 PaE elB of 49 Modes: 1, 2, 3, 4 potentiai LULO Core Cooling Red Core Cooling Orange OR pibe Heat Sink Red (RHR Not in Service)

  • i*~ii!*~~ii!!*i~iii~

~~iiiiiii~iiiiiiii!*i~~iii~i...

i~i*;; i~~.. i......

iii iiii i~! i iiiii~ i,!iii'iiiiii K, sampie activity is Greater Than 300 p.tCi/gm Not applicable dose equivalent iodine-131 Potential LOSS Greater Than 12000F IGreater Than 7270F Potential LOSS Not Applicable VALID RVLIS level <33%

(No RCP running)

VALILu *eaulng increase of Greater Than:

74 R/hr On 1-RE-90-271 and 272 OR 59 R/hr On I-RE-90-273 and 274 Any condition that, in the Judgment of the SM/SED, Indicates Loss or Potential Loss of the Fuel Clad Barrier Comparable to the Conditions Listed Above.

RCLS-Leak results in Loss of subcooling

(<65°F Indicated),

[85-F ADV]

Potential LOSS Pressurized Thermal Shock Red OR Heat Sink Red (Pi-4 Not iin Sprvinp.

Non Isolatable RCS Leak Exceeding The Capacity of One Charging Pump (CCP)

In the Normal Charging Alignment.

OR RCS Leakage Results In Entry Into F-1 I*PotentialI SGTR that results in a Not Applicable safety injection actuation OR Entry into E-3 O.....

LSS VALID RVLIS level

<33%

(No RCP Running)

Potential LOSS Not Applicable Any condition that, in the Judgment of the SM/SED, Indicates Loss or Potential Loss of the RCS Barrier Com arable to the Conditions Listed Above.

Containment (FR-Z.1) Red OR Actions of FR-C.1 (Red Path)

  • are INEFFECTIVE

.are.INEFFECTIVE

.... R......

LOS Potential LOSS Rapid unexplained decrease Containment Hydrogen following initial increase Increases to >4% by volume OR O6R Containment pressure or Pressure >2.8 PSIG (Phase..

Sump level Not increasing B) with < One full train of (with LOCA in progress)

Containment spray Potential LOSS Containment Isolation is Not Applicable Incomplete AND a Release Path to the Environment Exists

-R 4.cntnment.-Byp...ss RUPTURED S/G is also Unexplained VALID increase FAULTED outside CNTMT in area or ventilation RAD OR monitors in areas adjacent to Prolonged (>4 Hours)

CNTMT (with LOCA in Secondary Side release progress) outside CNTMT from a S/G with aSGTL > T/S Limits INSTRUCTIONS NOTE: A condition' is considered to be MET if, in the judgment of the Site Emergency Director, the condfiton will be MET imminently (i.e., within 1 to 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />, in the absence of a viable success path).

The classification shall be made a soon as this determination is made.

1. In the matrix to the left, review the INITIATING CONDITIONS in all columns and identify which, if any, INITIATING CONDITIONS are MET.

Circle these CONDITIONS.

2. For each of the three barriers, identify if any LOSS or Potential LOSS INITIATING CONDITIONS have been MET.
3. If a CSF is listed as an INITIATING CONDITION; the respective status tree criteria will be monitored and used to determine the EVENT classification for the Modes listed on the classification flowchart.
4. Compare the barrier losses and potential losses to the EVENTS below and make the appropriate declaration.

EVENTS UNUSUAL EVENT Loss or Potential LOSS of Containment Barrier SITE AREA EMERGENCY LOSS or Potential LOSS of any two barriers ALERT Any LOSS or Potential LOSS of Fuel Clad barrier OR Any LOSS or Potential LOSS of RCS barrier LOSoiO are GENERAL EMERGENCY LOSS of any two barriers and Potential LOSS of third barrier F

I S

S I

0 N

P 0

D U

C T

B A

R R

I E

R M

A T

R I

X U

=

=

=

==

5 Potential LOSS Not Applicable VALID Reading increase of Greater Than:

108 R/hr on 1-RE-90-271 and 1 -RE-90-272 OR 86 R/hr on 1 -RE-90-273 and I1 -RE-90-274 1 -RE-90-274 Any condition that, in the Judgment of the SM/SED, Indicates Loss or Potential Loss of the CNTMT Barrier Comparable to the Conditions Listed Above.

the Conditions Listed Above.

I mmmmmý L.ý I

I

ý I r-w

FILING INSTRUCTIONS EPIP-2 EPIP-2, Revision 14 EPIP-2, Revision 15 Remove Insert

TENNESSEE VALLEY AUTHORITY WATTS BAR NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURES EPIP-2 NOTIFICATION OF UNUSUAL EVENT Revision 15 Unit 0 QUALITY RELATED PREPARED BY:

Frank L. Pavlechko (Type Name)

SPONSORING ORGANIZATION:

Emergency Planning APPROVED BY Frank L. Pavlechko EFFECTIVE DATE: 4/25/01 LEVEL OF USE: REFERENCE

REVISION LOG Revision Implementation Description of Revision Number Date 0

04/13/90 Superseded IP-2 1

04/01/91 Editorial and format changes 2

01/22/92 Editorial and format changes 3

02/10/93 Add Section 2.0 Responsibility. Add Site Emergency Director announcements to Section 3.0. Change Section 3.0 to reflect removal of red Emergency Notification System ring-down phones which are being replaced by NRC designated phones which will require dialing a number. Add NUREG 0654, FEMA-REP-1, Rev. 1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in support of Nuclear Power Plants.

4 08/16/93 Editorial (non-intent) and format changes. Source notes added to the procedure.

5 05/27/94 Follow-up notification form added to the procedure.

Phone numbers revised.

6 08/01/94 Initial Dose Assessment for Radiological Emergencies (EPIP-16) referenced and phone numbers to the NRC Response Center revised.

7 04/21/95 Phone number revised. Editorial (non-intent) changes made.

Revision Implementation Pages Description of Revision Number Date Affected CN-1 09/28/95 4, 5 Phone numbers revised (new area code).

Editorial (non-intent) changes made.

8 7/5/96 4,5,6,7,8 Phone number and titles revised. Procedure (TI-30) replacement identified. All revisions were evaluated to be non-intent.

9 10/10/96 3,4,5, 8,9 The following non-intent revisions were made: SM designee identified by title, OSC and TSC support personnel instruction added, a reference was added and the non QA record instructions revised.

CN-1 3/27/97 3,5,6 TEMA additional back-up number added.

NOTIFICATION OF UNUSUAL EPIP-2 WBN EVENT Revision 15 Page 3 of 12 Revision Implementation Pages Description of Revision Number Date Affected CN-2 2/2/98 3,5,7,8 SSP-4.05 was replaced by SPP-3.5 in new procedure system. Editorial.

10 6/30/98 All Non-Intent Change. Incorporated Change Notices 1 and 2. Changed reference SSP 3.4 to SPP 3.1.

11 10/21/99 All Non Intent Change. Moved termination of emergency step from Appendix A to Appendix B. STD-3.2 reference canceled.

12 6/14/00 All Non Intent Change. Revised reference number. Added backup call to the ODS should the EPS fail to operate. Added the word actions after notifications in Step 4 for clarification.

13 10/31/00 All Non-Intent change. Revised NRC dedicated pg. 5 phones from FTS-2000 to TVA phone circuits per (RIS) 2000-11 "NRC Emergency Telecommunications Systems".

14 3/30/01 All Plan effectiveness determinations revisions Page 6,10 indicate the following revisions do not reduce the level of effectiveness of the procedure or REP:

Non-Intent change. Revised phone number.

Revised initial notification form to standardize within TVAN and meet new NEI PI requirements to the NRC.

15 All 4/25/01 Plan effectiveness determinations revisions pg. 2, 10 indicate the following revisions do not reduce the level of effectiveness of the procedure or REP:

Non-Intent change. Corrected typo.

NOTIFICATION OF UNUSUAL EPIP-2 WBN EVENT Revision 15 Page 4 of 12 1.0 PURPOSE 1.1 To provide a method for timely notification of appropriate individuals when the Shift Manager (SM) or Site Emergency Director (SED), Technical Support Center (TSC) has determined by WBN, EPIP-1 that an incident has occurred which is classified as a NOTIFICATION OF UNUSUAL EVENT.!

1.2 To provide a method for periodic reanalysis of the current situation by the SED to determine whether the NOTIFICATION OF UNUSUAL EVENT action(s) should be terminated, continued or upgraded to another classification.

2.0 RESPONSIBILITY The SED who is initially the SM (or other SM on-site during the emergency) or designee (Unit Supervisor, US) until properly relieved by the TSC SED, has the responsibility and authority for implementation of the action(s) in this instruction. 5 3.0 INSTRUCTIONS 3.1 Upon determining that existing conditions are classified as a NOTIFICATION OF UNUSUAL EVENT according to EPIP-1 (independent evaluations by crew members may be beneficial), the SED, or designee, will: 4, 5

1.

IF there are personnel injuries, IMPLEMENT EPIP-10, "Medical 0

Emergency Response."

2.

COMPLETE Appendix A, Notification Information 0

3.

ANNOUNCE to the crew: "A Notification of Unusual Event 03 is being declared based on I will be the Site Emergency Director."

4.

NOTIFY the ODS direct by ODS Ringdown or No. 5-751-1700 or 5-751-2495 and PROVIDE the information from Appendix A. IF the ODS cannot be contacted within 10 minutes, the Tennessee Emergency Management Agency is to be notified of the Radiological Emergency Plan activation by calling:

9-1-800-262-3300 or 9-1-615-741-0001 or 9-1-800-262-3400.2 1

5.

FAX Appendix A to the ODS. (# pre-programmed or 5-751-8620.)

13

6.

ANNOUNCE to the plant, "ATTENTION ALL SITE PERSONNEL.

ATTENTION ALL SITE PERSONNEL. A Notification of Unusual Event is being declared based on conditions." (Repeat) 03

7.

NOTIFY Duty Plant Manager, and PROVIDE Appendix A information (SEE duty list for telephone numbers). The Duty Plant Manager will call the Plant Manager or alternate.

o

8.

IF TSC and OSC support is needed, ACTIVATE the emergency paging system (EPS).

03 NOTE If the EPS system fails, call the ODS ringdown or (5-751-1700) and have him activate the EPS.

9.

NOTIFY NRC, using the designated NRC phone (ENS), of plan activation.

0 NOTE NRC notification should be made as soon as practicable, within one hour of "NOTIFICATION OF UNUSUAL EVENT" declaration. Whenever NRC requests, a qualified person must provide a continuous update to the NRC Operations Center. The following commercial numbers are for the NRC Operations Center:3,6 9-1-301-816-5100 (MAIN) 9-1-301-951-0550 (Backup) 9-1-301-816-5151 (FAX)

10.

EVALUATE the need to implement EPIP-16, "Initial Dose Assessment for Radiological Emergencies, "for a dose projection if radioactivity is being released through normal plant release paths.

0

NOTIFICATION OF UNUSUAL EPIP-2 WBN EVENT Revision 15 Page 6 of 12 3.0 INSTRUCTIONS (continued)

11.

NOTIFY WBN Emergency Preparedness.

03 NOTE Notification to Emergency Preparedness should be made as soon as practicable, but only when notification does not interfere with emergency actions or notifications in progress.

Work - 3232 or Work - 8004 or 1838 Home 1-423-337-2911 Home 1-865-376-4691 Pager - 30374 Pager - 70215

12.

REEVALUATE the event using WBN EPIP-1 as necessary to determine if conditions warrant reclassification.

o A.

IF the situation no longer exists, TERMINATE the emergency by informing the ODS and the Duty Plant Manager.

B.

IF the condition warrants upgrading to a higher classification, INITIATE the appropriate steps of WBN EPIPs 3, 4, or 5.

C.

IF other plant conditions warrant the need for follow-up information, COMPLETE the Follow-up Notification Form, Appendix B and NOTIFY the TSC/CECC (if it is staffed), or NOTIFY the ODS direct by ODS Ringdown or No. 5-751-1700 or 5-751-2495 and PROVIDE the information. IF the ODS cannot be contacted within 10 minutes, the Tennessee Emergency Management Agency is to be notified of the information by calling:

9-1-800-262-3300 or 9-1-615-741-0001 or 9-1-800-262-3400.2 0

3.0 INSTRUCTIONS (continued)

13.

FAX Appendix B to the ODS.

(# pre-programmed or 5-751-8620.)

If there is any possibility of a radiological release, do not send personnel into areas of unknown radiological conditions without first contacting Radiological Control.

14.

ENSURE applicable notifications/actions required by SPP-3.5 and SPP-3.1 have been made.

15.

NOTIFY the NRC Resident Inspector by calling 1776 and PROVIDING the information on Appendix A.

16.

After the event is terminated, SEND the completed WBN EPIP-2 and associated documentation to WBN Emergency Preparedness (EP) Manager. The EP Manager shall forward documentation to DCRM for storage as appropriate.

CAUTION 0

0]

0]

0

NOTIFICATION OF UNUSUAL EPIP-2 WBN EVENT Revision 15 Page 8 of 12 4.0 4.1 4.2 Other Documents 10 CFR 50.72 Immediate Notification Requirements for Operating Nuclear Power Reactors NUREG-0654, FEMA-REP-1, Rev. 1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants.

ANSI N 18.7 - 1976 REFERENCES Interfacing Documents SPP-3.1 Corrective Action Program SPP-3.5 Regulatory Reporting Requirements WBN-EPIP-1 Emergency Plan Classification Flowchart WBN-EPIP-3 Alert WBN-EPIP-4 Site Area Emergency WBN-EPIP-5 General Emergency WBN-EPIP-10 Medical Emergency Response WBN-EPIP-13 Termination of the Emergency and Recovery WBN-EPIP-14 Radiological Control Response WBN-EPIP-16 Initial Dose Assessment for Radiological Emergencies CECC-EPIP-9 Emergency Environmental Radiological Monitoring Procedures

5.0 APPENDIX Appendix A, Notification Information Appendix B, Follow-up Notification Form 6.0 RECORDS 6.1 QA Records Entire EPIP-2, when the REP is activated, is a QA Record.

6.2 Non QA Records All EPIP-2 records generated during the course of a drill/exercise will be assembled by the EP Manager and stored appropriately.

APPENDIX A (Page 1 of 1)

INITIAL NOTIFICATION FORM NOTIFICATION OF UNUSUAL EVENT 1,4

[I THIS IS AN ACTUAL EVENT

-1I THIS IS AN EXERCISE This is NAME A NOTIFICATION OF UNUSUAL EVENT has been declared at Watts Bar Nuclear Plant affecting:

IE-Unit 1 F1 Unit 2 Event Declared:

Time:

Date:

EAL Designator (e.g., Fire 4.1):

Brief Description of the Event:

Radiological Conditions:

F-- No Abnormal Releases Offsite FI Airborne Release Offsite L-Liquid Release Offsite L-1 Release Information Not Known at this time EL There is no Protective Action Recommendation at this time.

FL] Ask, "Please repeat the information you have received to ensure accuracy."

APPENDIX B (Page 1 of 1)

WBN FOLLOW-UP INFORMATION FORM NOTIFICATION OF UNUSUAL EVENT

1.

o] "THIS IS A REAL EVENT" or 13 "THIS IS A DRILL."

2.

"This is at the Watts Bar Nuclear Plant.

This is follow-up information regarding the Notification of Unusual Event at Watts Bar:

Unit 1 [o Unit 2 o."

3.

"Reactor:

Shutdown [3 At power 0"

4.

"Plant conditions are:

Stable n Deteriorating ["

5.

"Follow-up information: (e.g., key events, status changes)

6.

"The radiological conditions are:

o1 No Abnormal Release Offsite o]

Airborne Release Offsite o1 Liquid Release Offsite o3 Release Information Not Known."

7.

"Additional Rad information: (e.g., release duration)

8.

o] "There is no Protective Action Recommendation at this time."

9.

"The event terminated at

/

Time Date

10.

o "Please repeat the information you have received to ensure accuracy."

11.

/

/

Signature Time Date

SOURCE NOTES Page 1 of 1 1

NRC IE Information Notice 89-89 2

NRC IE Information Notice 86-97 3

NRC IE Information Notice 86-28 4

MC 840827 00500 4A, MSC-02375, NCO 9200 30985 5

ANSI N18.7-1976 Subsection 5.3.9.3: 01 POR 6

NRC Administrative Letter 94-04 Event Notification Worksheets Emergency Communications System Telephone Numbers to the NRC Operations Center and Regional Offices.

Section 3.0 Instructions, 3.1, and Appendix A (Page 1 of 1).

EPIPs will contain the following elements.

Change of NRC Operation Center commercial telephone and facsimile numbers.

FILING INSTRUCTIONS EPIP-3 EPIP-3, Revision 17 EPIP-3, Revision 18 Remove Insert

TENNESSEE VALLEY AUTHORITY WATTS BAR NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURES EPIP-3 ALERT Revision 18 Unit 0 QUALITY RELATED PREPARED BY:

Frank L. Pavlechko (Type Name)

SPONSORING ORGANIZATION:

Emergency Planning APPROVED BY:

Frank L. Pavlechko EFFECTIVE DATE:

4/25/01 1 LEVEL OF USE: REFERENCE

EPIP-3 WBN ALERT Revision 18 Page 2 of 12 REVISION LOG Revision Implementation Description of Revision Number Date 0

04/13/90 Superseded IP-3 1

04/01/91 Editorial and format changes.

2 01/22/92 Enhanced with human factor editorial changes and updated references.

3 02/10/93 Insert Section 2.0 Responsibility. Add Site Emergency Director announcements to Section 3.0. Change title of Plant Duty Supervisor to Duty Plant Manager. Change Section 3.0 to reflect removal of red Emergency Notification System ring-down phones which are being replaced by NRC designated phones which will require dialing a number. Modify Appendix A so that when faxed or copied, last few lines will not be excluded. Removed notes which addressed steps that have already been performed. NUREG 0654, FEMA-REP-1, Rev.1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in support of Nuclear Power Plants.

4 8/16/93 Editorial (non-intent) and format changes. Source notes added to the procedure.

5 1/1/94 Added NRC Resident call as Step 16.

6 01/11/94 Included notifying Security (CAS) on Step 9. changed wording on Step 17 to initiate WBN EPIP-13.

7 05/27/94 Followup Notification Form added to the procedure. Phone numbers revised.

8 8/1/94 Initial Dose Assessment for Radiological Emergencies (EPIP-16) referenced and phone numbers to the NRC Response Center revised.

9 10/14/94 Revised phone number.

10 04/21/95 Revised phone numbers. Editorial (non-intent) changes made.

Revision Implementation Pages Description of Revision Number Date Affected 1

7/5/96 4,5,7,8 Phone number and titles revised. Procedure replacement (TI-30) identified. All revisions were evaluated to be non-intent 2

10/10/96 3,4,8,9 The following non-intent revisions were made: Shift Personnel replaced Shift Clerk to reflect additional personnel trained on the paging system, SM designee identified by title, a phone number added, a reference was added and the non-QA record instructions were revised.

EPIP-3 WBN ALERT Revision 18 Page 3 of 12 Revision Implementatio Pages Description of Revision Number n

Affected Date CN-1 3/27/97 3,5,7 TEMA added alternate phone number.

CN-2 2/2/98 3, 5, 7, 8 SSP-4.05 was replaced by SPP-3.5 in new procedure system. Editorial changes.

13 6/30/98 All Non-Intent Changes. Incorporated Change Notices 1 and

2. Changed reference SSP 3.4 to SPP 3.1.

14 10/21/99 All Non Intent Change. Moved termination of emergency step from Appendix A to Appendix B. STD-3.2 referenced canceled.

15 06/14/00 All Non Intent Change. Revised reference number. Added reference to the direct line to the ODS for clarification.

Added the word actions after notifications in Step 19 for clarification.

16 10/31/00 All Non-Intent change. Revised NRC dedicated pg. 6 phones from FTS-2000 to TVA phone circuits per (RIS) 2000-11 "NRC Emergency Telecommunications Systems".

17 3/30/01 All Plan effectiveness determinations revisions Page 10 indicate the following revisions do not reduce the level of effectiveness of the procedure or REP:

Non-Intent change. Revised initial notification form to standardize within TVAN and meet new NEI PI requirements to the NRC.

18 4/25/01 All Plan effectiveness determinations revisions pg. 2, 10 indicate the following revisions do not reduce the level of effectiveness of the procedure or REP:

Non-Intent change. Corrected typo.

EPIP-3 WBN ALERT Revision 18 Page 4 of 12 1.0 PURPOSE 1.1 To provide a method for timely notification of appropriate individuals when the Shift Manager (SM) or Technical Support Center (TSC) Site Emergency Director (SED) has determined by WBN EPIP-1 that an incident has occurred which is classified as an ALERT.4 1.2 To provide a method for periodic reanalysis of the current situation by the SED to determine whether the ALERT should be terminated, continued or upgraded to another classification.

2.0 RESPONSIBILITY4 The SED who is initially the SM (or other SM onsite during the emergency) or designee (Unit Supervisor, US) until properly relieved by the TSC SED, has the responsibility and authority for implementation of the actions in this instruction.

3.0 INSTRUCTIONS 4

3.1 Upon determining that existing conditions are classified as an ALERT according to EPIP-1 (independent evaluations by crew members may be beneficial), the SED, or designee, will:

1.

DIRECT Shift Personnel to activate the Emergency Paging System 0

(EPS) to staff the TSC and Operations Support Center (OSC).

Shift Personnel should confirm activation and provide the 20 minute printed report to the SM for review.

NOTE 1 IF the EPS systems fails, call the ODS, ringdown or (5-751-1700) and have him activate the EPS.

NOTE 2 IF the above methods of activating the EPS fail, the Shift Personnel must use the Radiological Emergency Response Call Lists to staff the TSC and OSC. This list is located in the EPS Manual near the terminal.

2.

COMPLETE Appendix A, Notification Information.

3.

ANNOUNCE to the crew:

"An Alert is being declared based on 0

_ I will be the Site Emergency Director."

"EPIP-3 WBN ALERT Revision 18 Page 5 of 12 3.0 INSTRUCTIONS (continued)

4.

NOTIFY the ODS direct by ODS Ringdown or No. 5-751-1700 or 5-751-2495 and PROVIDE the information from Appendix A. If the ODS cannot be contacted within 10 minutes, the Tennessee Emergency Management Agency is to be notified of the Radiological Emergency Plan activation by calling 9-1-800-262-3300 or 9-1-615-741 -0001 or 9-1-800-262-3400.2

5.

FAX Appendix A to the ODS.

(No. pre-programmed or 5-751-8620.)

6.

ANNOUNCE to the plant: "ATTENTION ALL SITE PERSONNEL.

ATTENTION ALL SITE PERSONNEL.

An ALERT emergency has been declared based on Staff the TSC and OSC." (Repeat)

7.

EVALUATE plant conditions, assembly and accountability additional details, go to WBN Evacuation").

IF you are accountability, GO TO step 10.

and IF conditions warrant, INITIATE by completing steps 8 and 9.

(For EPIP-8, "Personnel Accountability and not going to initiate assembly and

9.

ANNOUNCE to the plant:

"ATTENTION ALL SITE PERSONNEL.

ATTENTION ALL SITE PERSONNEL. Report to your assembly areas for accountability" (Repeat) AND ACTIVATE assembly alarm for personnel assembly and accountability. INITIATE WBN EPIP-8, "Personnel Accountability and Evacuation."'

10.

CALL RADCON Lab and SAY: "We are in an Alert, implement WBN EPIP-14 and CECC EPIP-9."

El El

8.

NOTIFY Security (CAS) that assembly and accountability is to be conducted.

0l 0l 0l

[]

[]

CAUTION If there is any possibility of a radiological release, do not send personnel into areas of unknown radiological conditions without first contacting Radiological Control (RADCON).

EPIP-3 WBN ALERT Revision 18 Page 6 of 12 3.0 INSTRUCTIONS (continued)

11.

IF there are personnel injuries, IMPLEMENT WBN EPIP-1 0, "Medical Emergency Response."

12.

IF there is a security threat, IMPLEMENT WBN EPIP-1 1, "Security and Access Control."

13.

NOTIFY Duty Plant Manager, and PROVIDE Appendix A information (SEE duty list for telephone numbers). The Duty Plant Manager will call the Plant Manager or his alternate.

14.

EVALUATE the need to implement EPIP-16, "Initial Dose Assessment 0

for Radiological Emergencies," for a dose projection if radioactivity is being released through normal plant release paths.

15.

NOTIFY the NRC, using designated NRC phone (ENS), of plan activation.

0 NOTE NRC notification should be made as soon as practicable but within one hour of "ALERT" declaration. Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center. The following commercial numbers are for the NRC Operations Center:3' 5 9-1-301-816-5100 (MAIN) 9-1-301-951-0550 (BACKUP) 9-1-301-816-5151 (FAX)

16.

NOTIFY the NRC Resident Inspector by calling 1776 and PROVIDING the information on Appendix A.

0

EPIP-3 WBN ALERT Revision 18 Page 7 of 12 3.0 INSTRUCTIONS (continued)

17.

REEVALUATE conditions using WBN EPIP-1 as necessary.

C A.

IF the conditions are under control, INITIATE actions identified in WBN EPIP-13, 'Termination of the Emergency and Recovery."

B.

IF the conditions warrant upgrading to a higher classification, INITIATE the appropriate steps of WBN EPIP-4 or EPIP-5.

C.

IF other plant conditions warrant the need for followup information, COMPLETE the Followup Notification Form, Appendix B, and NOTIFY the TSC/CECC (if it is staffed) or, NOTIFY the ODS direct by ODS Ringdown or No. 5-751-1700 or 5-751-2495 and PROVIDE the information.

IF the ODS cannot be contacted within 10 minutes, the Tennessee Emergency Management Agency is to be notified of the information by calling:

9-1-800-262-3300 or 9-1-615-741-0001 or 9-1-800-262_34002

18.

FAX Appendix B to the ODS.

(No. pre-programmed or 5-751-8620.)

19.

ENSURE applicable notifications/actions required by SPP-3.5 and SPP-3.1 have been made.

20.

SEND the completed WBN EPIP-3 and associated documentation to El the Emergency Preparedness (EP) Manager. The EP Manager shall forward documentation to DCRM for storage as appropriate.

EPIP-3 WBN ALERT Revision 18 Page 8 of 12

4.0 REFERENCES

4.1 Interfacing Documents SPP-3.5 Regulatory Reporting Requirements SPP-3.1 Corrective Action Program WBN-EPIP-1 Emergency Plan Classification Flowchart WBN-EPIP-2 Notification of Unusual Event WBN-EPIP-4 Site Area Emergency WBN-EPIP-5 General Emergency WBN-EPI P-1 0 Medical Emergency Response WBN-EPIP-1 1 Security and Access Control WBN-EPIP-13 Termination of the Emergency and Recovery WBN-EPIP-1 6 Initial Dose Assessment for Radiological Emergencies CECC-EPIP-9 Emergency Environmental Radiological Monioring Procedures 4.2 Other Documents 10 CFR 50.72 Immediate Notification Requirements for Operating Nuclear Power Reactors NUREG 0654, FEMA-REP-1, Rev. 1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants.

ANSI N18.7-1976 CECC-EPIP-8 Dose Assessment Staff Activities During Nuclear Plant Radiological Emergencies

EPIP-3 WBN ALERT Revision 18 Page 9 of 12 5.0 APPENDIX Appendix A, Notification Information Appendix B, Followup Notification Form 6.0 RECORDS 6.1 QA Records Entire WBN EPIP-3, when the REP is activated, is a QA Record.

6.2 Non-QA Records All EPIP-3 records generated during the course of a drill/exercise will be assembled by the EP Manager and stored appropriately.

EPIP-3 WBN ALERT Revision 18 Page 10 of 12 APPENDIX A (Page 1 of 1)

INITIAL NOTIFICATION FORM1 ALERT F--

THIS IS A REAL EVENT

-I THIS IS A DRILL This is NAME An ALERT has been declared at Watts Bar Nuclear Plant affecting:

r-- Unit I El Unit2 Event Declared:

Time:

Date:

EAL Designator (e.g., Fire 4.1):

Brief Description of the Event:

Radiological Conditions:

F--

No Abnormal Releases Offsite El Airborne Release Offsite E] Liquid Release Offsite El Release Information Not Known at this time El There is no Protective Action Recommendation at this time.

El Ask "Please repeat the information you have received to ensure accuracy."

=

=

B

EPIP-3 WBN ALERT Revision 18 Page 11 of 12 APPENDIX B (Page 1 of 1)

WBN FOLLOWUP INFORMATION FORM ALERT

1.

0

'THIS IS A REAL EVENT' or 0l 'THIS IS A DRILL."

2.

'This is at the Watts Bar Nuclear Plant.

This is followup information regarding the Alert at Watts Bar:

Unit 1 0

Unit 2 0."

3.

"Reactor:

Shutdown 0l At power El"

4.

"Plant conditions are:

Stable 0l Deteriorating El"

5.

"Followup information: (e.g., key events, status changes)

6.

"Site Assembly and Accountability is ongoing: Yes El No D"

7.

'The radiological conditions are:

"El No Abnormal Release Offsite "El Airborne Release Offsite "El Liquid Release Offsite "El Release Information Not Known."

8.

"Additional Rad information: (e.,.. release duration)

9.

El

'There is no Protective Action Recommendation at this time."

10.

'The event terminated at

/

Time Date

11.

El "Please repeat the information you have received to ensure accuracy."

12.

I

/

Signature Time Date w

EPIP-3 WBN ALERT Revision 18 Page 12 of 12 SOURCE NOTES Page 1 of 1 I

NRC IE Information Notice No. 89-89 2

NRC IE Information Notice No. 86-97 NRC IE Information Notice No. 86-28 ANSI N18.7-1976 Subsection 5.3.9.3: 01 POI NRC Administrative Letter 94-04 Event Notification Worksheets Emergency Communications System Telephone Numbers to the NRC Operations Center and Regional Offices EPIPs will contain the following elements.

Change of NRC Operations Center commercial telephone and facsimile numbers.

FILING INSTRUCTIONS EPIP-4 EPIEP-4, Revision 18 EPIP-4, Revision 19 Remove Insert

TENNESSEE VALLEY AUTHORITY WATTS BAR NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURES EPIP-4 SITE AREA EMERGENCY Revision 19 Unit 0 QUALITY RELATED PREPARED BY:

Frank L. Pavlechko (Type Name)

SPONSORING ORGANIZATION:

Emergency Planning APPROVED BY:

Frank L. Pavlechko EFFECTIVE DATE: 4/25101 LEVEL OF USE: REFERENCE

REVISION DESCRIPTION Revision Implementation Description of Revision Number Date 0

04/13/90 Superseded IP-4.

1 04/01/91 Editorial and format changes.

2 01/22/92 Improved human factoring (pages 2-4) and updated references. Add a step for SM Clerk to provide EPS activation confirmation to SM. Specify EAL unique identifier in event description (Attachment 1).

3 02/10/93 Add Section 2.0 Responsibility. Add Site Emergency Director announcements to Section 3.0.

Change title of Plant Duty Supervisor to Duty Plant Manager. Change Section 3.0 to reflect removal of red Emergency Notification System ring-down phones which are being replaced by NRC designated phones which will require dialing a number.

Modify Appendix A so that when faxed or copied, last few lines will not be excluded. Removed notes which addressed steps that have already been performed. NUREG 0654, FEMA-REP-1, Rev.1, Citeria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in support of Nuclear Power Plants.

4 8/16/93 Editorial (non-intent) and format changes. Source notes added to the procedure.

5 1/1/94 Added NRC Resident Call as Step 14.

6 4/11/94 Included notifying Security (CAS) on Step 7 and changed Step 15 to initiate WBN EPIP-1 3. Added county contingency notifications to Step 4.

7 5/27/94 Followup Information Form added to the procedure. Phone numbers revised.

8 8/1/94 Initial Dose Assessment for Radiological Emergencies (EPIP-16) referenced and phone numbers to the NRC Response Center revised.

9 10/14/94 Revised phone number to McMinn County.

10 4/21/95 Revised a phone number. Editorial (non-intent) change made.

Revision Implementation Pages Description of Revision Number Date Affected CN-1 9/28/95 5

Revised phone numbers. Editorial (non-intent) changes made.

11 7/5/96 4,5,7,8 Phone number and titles revised. Procedure replacement ("1-30) identified. All revisions were evaluated to be non-intent.

EPIP-4 WBN SITE AREA EMERGENCY Revision 19 Page 3 of 12 Revision Implementation Pages Description of Revision Number Date Affected 12 10/10/96 3,4,5,8,9, The following non-intent revisions were made: Shift 10 Personnel replaced Shift Clerk to reflect additional personnel trained on the paging system, SM designee identified by title, a phone number was added, assembly and accountability instruction enhanced, a reference was added, the non-QA record instructions were revised, and wind speed and direction were added to the initial notification form per TEMA request.

CN-1 3/27/97 3,5,6,7 TEMA additional back-up number added, changed county primary and back-up numbers CN-2 7/31/97 3,5 Phone number change.

CN-3 2/2/98 3,5,7,8 SSP-4.05 was replaced by SPP-3.5. Editorial change.

13 6/30/98 All Non-intent changes. Incorporated Changes Notices 1, 2 and 3. Changed reference SSP 3.4 to SPP 3.1.

14 10/21/99 All Non-intent change. Moved termination of emergency step from Appendix A to Appendix B. STD-3.2 reference canceled.

15 02/08/00 ALL Non-Intent change. Phone numbers revised.

16 06/14/00 All Non Intent change. Reference number revised. Phone number revised. Added the word actions after notifications in Step 17 for clarification. Added reference to the ODS, direct line for clarification. This revision resolves problem identified in WBN PER, 006394.

17 10/31/00 All Non-Intent change. Revised NRC dedicated phones from FTS-2000 to TVA phone circuits per (RIS) 2000 pg. 6 11 "NRC Emergency Telecommunications Systems".

Plan effectiveness determinations revisions indicate 18 3/30/01 All the following revisions do not reduce the level of Page 5,10 effectiveness of the procedure or REP:

Non-Intent change. Revised phone numbers.

Revised initial notification form to standardize within TVAN and meet new NEI PI requirements to the NRC.

19 4/25/01 All' Plan effectiveness determinations revisions indicate 19 4/25/01 the following revisions do not reduce the level of pg. 2, 10 effectiveness of the procedure or REP:

Non-Intent change. Corrected typo.

1.0 PURPOSE4 1.1 To provide a method for timely notification of appropriate individuals when the Shift Manager (SM) or Technical Support Center (TSC) SED has determined by WBN EPIP-1 that an incident has occurred which is classified as a SITE AREA EMERGENCY.

1.2 To provide a method for periodic reanalysis of the current situation by the SED to determine whether the SITE AREA EMERGENCY should be terminated, continued or upgraded to a General Emergency.

2.0 RESPONSIBILITY 4 The SED who is initially the SM (or other SM onsite during the emergency) or designee (Unit Supervisor, US) until properly relieved by the TSC SED, has the responsibility and authority for implementation of the actions in this instruction.

3.0 INSTRUCTIONS 3.1 Upon determining that existing conditions are classified as a SITE AREA EMERGENCY according to WBN EPIP-1 (independent evaluations by crew members may be beneficial), the SED, or designee, will: 4

1.

DIRECT the Shift Personnel to activate the Emergency Paging System (EPS) to staff the TSC and Operations Support Center (OSC).

Shift Personnel should confirm activation and provide the 20 minute 0

printed report to the SM for review.

NOTE I IF the EPS system fails, call the ODS, ringdown or (5-751-1700) and have him activate the EPS.

NOTE 2 IF the above methods of activating the EPS fail, Shift Personnel must use the Radiological Emergency Response Call Lists to staff the TSC and OSC. This list is located in the EPS Manual near the terminal.

3.0 INSTRUCTIONS (continued)

2.

COMPLETE Appendix A Notification Information.

3.

ANNOUNCE to the crew: "A Site Area Emergency is being declared based on

. I will be the Site Emergency Director, all support and job assignments must be authorized through me."

4.

NOTIFY the ODS direct by ODS Ringdown or No. 5-751-1700 or 5-751-2495 and PROVIDE the information from Appendix A.

IF the ODS cannot be contacted within 10 minutes, then directly notify Rhea County, Meigs County, McMinn County, and the Tennessee Emergency Management Agency (TEMA) of the classification.

Rhea County EMA (Alternate)

Meigs County EMA (Alternate)

McMinn County (Alternate)

Tennessee EMA (Alternate)

(Alternate) 9-775-2505 9-775-7828 9-1-423-334-3211 9-1-423-334-5268 9-1-423-744-2724 9-1-423-744-2721 9-1-800-262-3300 9-1-615-741-0001 9-1-800-262-3400 (TIME)

___(TIME)

(TIME)

___(TIME)

(TIME)

(TIME)

(TIME)

__-(TIME)

(TIME)

5.

FAX Appendix A to the ODS.

(No. pre-programmed or 5-751-8620.)

If there is any possibility of a radiological release, do not send personnel into areas of unknown radiological conditions without first contacting Radiological Control (RADCON).

6.

NOTIFY Security (CAS) that assembly and accountability is to be conducted.

El El 0

CAUTION El El

3.0 INSTRUCTIONS (continued)

7.

ANNOUNCE to the plant: "ATTENTION ALL SITE PERSONNEL.

ATTENTION ALL SITE PERSONNEL. A SITE AREA EMERGENCY has been declared based on

. All personnel report to your assembly areas for accountability.

Staff the TSC and OSC." (Repeat)

SOUND assembly alarm AND 0

INITIATE WBN EPIP-8, "Personnel Accountability and Evacuation."

0

8.

CALL RADCON Lab and SAY: "We are in a Site Area Emergency, implement WBN EPIP-14 and CECC EPIP-9."

9.

IF there are personnel injuries, IMPLEMENT WBN EPIP-10, "Medical Emergency Response".

10.

IF there is a security threat, IMPLEMENT WBN EPIP-1 1, "Security 0

and Access Control".

11.

NOTIFY Duty Plant Manager, and PROVIDE Appendix A information 0

(SEE duty list for telephone numbers). The Duty Plant Manager will call the Plant Manager or alternate.

12.

EVALUATE the need to implement EPIP-16, "Initial Dose Assessment 0

for Radiological Emergencies," for a dose projection if radioactivity is being released through normal plant release paths.

13.

NOTIFY the NRC, using designated NRC phone (ENS), of plan El activation.

NOTE NRC notification should be made as soon as practicable, within one hour of "SITE AREA EMERGENCY' declaration.

Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center. The following commercial numbers are for the NRC Operations Center:3,5 9-1-301-816-5100 (MAIN) 9-1-301-951-0550 (BACKUP) 9-1-301-816-5151 (FAX)

EPIP-4 WBN SITE AREA EMERGENCY Revision 19 Page 7 of 12 3.0 INSTRUCTIONS (continued)

14.

NOTIFY the NRC Resident Inspector by calling 1776 and 0

PROVIDING the information on Appendix A.

15.

REEVALUATE conditions using WBN EPIP-1 as necessary.

0 A.

IF the conditions are under control, INITIATE actions identified in WBN EPIP-1 3, 'Termination of the Emergency and Recovery."

B.

IF conditions warrant upgrading to a higher classification, INITIATE the appropriate steps of WBN EPIP-5.

C.

IF other plant conditions warrant the need for followup information, COMPLETE the Followup Notification Form, Appendix B, and NOTIFY the TSC/CECC (if it is staffed) or, NOTIFY the ODS direct by ODS Ringdown or No. 5-751-1700 or 5-751-2495 and PROVIDE the information.

IF the ODS cannot be contacted within 10 minutes, the Tennessee Emergency Management Agency is to be notified of the information by calling 9-1-800-262-3300 or 9-1-615-741-0001 or 9-1-800-262-34002

16.

FAX Appendix B to the ODS.

(No. pre-programmed or 5-751-8620.)

0

17.

ENSURE applicable notifications/actions required by SPP-3.5 and 0

SPP-3.1 have been made.

18.

SEND the completed WBN EPIP-4 and associated documentation to 0

the Emergency Preparedness (EP) Manager. The EP Manager shall forward documentation to DCRM for storage as appropriate.

4.0 REFERENCES

4.1 Interfacing Documents SPP-3.1 Corrective Action Program SPP-3.5 Regulatory Reporting Requirements WBN-EPIP-1 Emergency Plan Classification Flowchart WBN-EPIP-2 Notification of Unusual Event WBN-EPIP-3 Alert WBN-EPIP-5 General Emergency WBN-EPIP-10 Medical Emergency Response WBN-EPIP-1 1 Security and Access Control WBN-EPIP-13 Termination of the Emergency and Recovery WBN-EPIP-1 6 Initial Dose Assessment for Radiological Emergencies CECC-EPIP-9 Emergency Environmental Radiological Monitoring Procedures 4.2 Other Documents 10 CFR 50.72 Immediate Notification Requirements for Operating Nuclear Power Reactors NUREG 0654, FEMA-REP-1, Rev. 1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants.

ANSI 18.7-1976 CECC-EPIP-8 Dose Assessment Staff Activities During Nuclear Plant Radiological Emergencies

EPIP-4 WBN SITE AREA EMERGENCY Revision 19 Page 9 of 12 5.0 APPENDIX Appendix A, Notification Information Appendix B, Followup Notification Form 6.0 RECORDS 6.1 QA Records Entire WBN EPIP-4, when the REP is activated, is a QA Record.

6.2 Non-QA Records All EPIP-4 records generated during the course of a drill/exercise will be assembled by the EP Manager and stored appropriately.

APPENDIX A (Page 1 of 1)

INITIAL NOTIFICATION FORM '

SITE AREA EMERGENCY

-I THIS IS A REAL EVENT I THIS IS A DRILL This is NAME An SITE AREA EMERGENCY has been declared at Watts Bar Nuclear Plant affecting:

EI Unit 1 i-Unit2 Event Declared:

Time:

Date:

EAL Designator (e.g., loss of AC 3.1):

Brief Description of the Event:

Radiological Conditions:

LI No Abnormal Releases Offsite

-1I Airborne Release Offsite FI Liquid Release Offsite F-1 Release Information Not Known at this time

-I There is no Protective Action Recommendation at this time.

Meteorological conditions are:

Wind Speed:

m.p.h.

Wind Direction From:

degrees F-I Ask "Please repeat the information you have received to ensure accuracy."

APPENDIX B (Paqe 1 of 1)

WBN FOLLOWUP INFORMATION FORM SITE AREA EMERGENCY

1.

El

'THIS IS A REAL EVENT' or 0l 'THIS IS A DRILL."

2.

'This is at the Watts Bar Nuclear Plant.

This is followup information regarding the Site Area Emergency at Watts Bar:

Unit 1 El Unit2 Il."

3.

"Reactor:

Shutdown

4.

"Plant conditions are:

Stable El El At power 0

"l Deteriorating l "

5.

"Followup information: (e.g., key events, status changes)

6.

"Onsite assembly and accountability is ongoing: Yes El

7.

'The radiological conditions are:

No Abnormal Release Offsite Airborne Release Offsite Liquid Release Offsite Release Information Not Known."

8.

"Additional Rad information: (e.a.. release duration)

9.

'The meteorological conditions are: Wind speed:

from:

Wind direction

10.

El

'There is no Protective Action Recommendation at this time."

11.

'The event terminated at

/

Time Date

12.

El "Please repeat the information you have received to ensure accuracy."

/

/

Signature Time Date El El El El No El "

13.

I$

11 Signature Time Date

SOURCE NOTES Page 1 of 1 1

NRC IE Information Notice No. 89-89 2

NRC IE Information Notice No. 86-97 NRC IE Information Notice No. 86-28 ANSI 18.7-1976, Subsection, 5.3.9.3: 01POI NRC Administrative Letter 94-04 Event Notification Worksheets Emergency Communications System Telephone Numbers to the NRC Operations Center and Regional Offices EPIPs will contain the following elements.

Change of NRC Operations Center commercial telephone and facsimile numbers.

FILING INSTRUCTIONS EPIP-5 Remove EPIP-5, Revision 19 Insert EPIP-5, Revision 20

TENNESSEE VALLEY AUTHORITY WATTS BAR NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURES EPIP-5 GENERAL EMERGENCY Revision 20 Unit 0 QUALITY RELATED PREPARED BY:

Frank L. Pavlechko (Type Name)

SPONSORING ORGANIZATION:

Emergency Planning APPROVED BY:

Frank L. Pavlechko EFFECTIVE DATE: 4/25/01 LEVEL OF USE: REFERENCE

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 2 of 12 REVISION LOG Revision Implementation Description of Revision Number Date 0

04/13/90 Superseded IP-5.

1 04/01/91 Reflect revision to Al 2.8.11 concerning SM designees for certain tasks. Convert ODS information to Attachment. Revised ODS communication methods.

2 01/22/92 Improved human factoring and updated references.

3 02/10/93 Changed coversheet. Added Section 2, Responsibility. Removed Note concerning steps previously done. In Section 3.1 included words concerning independent evaluating of crew members.

Included parenthesis and changed wording to aid operators in what to say. Changed order of steps. Removed Notes 1 and 2 in Section 2.1 because of redundancy. Changed TEMA telephone number.

Changed title of Plant Duty Supervisor to Duty Plant Manager.

Removed (red phone) from Section 2.2 due to FTS 2000 installations. Added Step 15 to ensure applicable notification.

4 08/16/93 Editorial (non-intent) and format changes.

Source notes added to the procedure.

5 1/1/94 Changes made to the Protective Action Recommendation Guidance to incorporate new 10 CFR 20 changes and EPA-400. Added NRC Resident call as Step 14.

6 4/11/94 Included notifying Security (CAS) on Step 5 and changed Step 15 to initiate WBN EPIP-1 3. Added contingency county notifications to Step 6.

7 5/27/94 Followup Notification Form was added to the procedure. Phone numbers revised.

8 8/1/94 Initial Dose Assessment for Radiological Emergencies (EPIP-16) referenced and phone numbers to the NRC Response Center revised.

9 10/14/95 Revised McMinn County phone number.

10 4/21/95 Revised phone numbers. Editorial (non-intent) changes made.

Revision Implementation Pages Description of Revision Number Date Affected CN-1 9/28/95 3,5,11 Revised phone numbers. Editorial (non-intent) changes made. All references to RM were changed to RE to make it consistent with site description documents.

11 7/5/96 4,5,6,7,8 Phone number and titles revised. Procedure replacement (TI-30) identified. All revisions were evaluated to be non-intent.

12 10/10/96 3,4,5,8,9 The following non-intent revisions were made: Shift Personnel replaced Shift Clerk to reflect additional personnel trained on the paging system, SM designee identified by title, a phone number was added, assembly and accountability instruction enhanced, a reference was added, and the non-QA record instructions were revised.

CN-1 3/27/97 3,5,6 TEMA additional back-up number added, counties changed phone numbers

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 3 of 12 Revision Implementation Pages Description of Revision Number Date Affected CN-2 2/2/98 3,5,6,7,8 SSP-4.05 was replaced by SPP-3.5. Editorial changes were made.

13 6/30/98 All Non-intent Changes. Incorporated Change Notices 1 and

2. Changed reference SSP 3.4 to SPP 3.1.

14 10/21/99 All Non-intent change. Moved termination step from Appendix A to Appendix C. STD-3.2 reference canceled.

15 02/08/00 All Non-intent change. Revised phone number.

16 6/14/00 All Non Intent change. Revised phone number. Reference number revised. Added reference to the ODS, direct line for clarification. Added the work actions after notifications in Step 17 for clarification. This revision resolves problem identified in WBN PER, 006394.

17 08/16/00 All Intent change. Revised CNTMT Rad Monitors (1-RE 90-271, 272, 273, & 274) readings to correspond with (Pg. 3, 1 the new TI-RPS-162, "Response of the Primary Containment High Range Monitors" readings (Reference EDC-50600). This analysis resulted in a revision to Table 2 on the PAR Chart. This revision resolves action items from CORP PER-99-000038 000. This revision was also determined not to reduce the level of effectiveness of the procedure or REP.

18 10/31/00 All Non-Intent change. Revised NRC dedicated phones pg. 6 from FTS-2000 to TVA phone circuits per (RIS) 2000 11 "NRC Emergency Telecommunications Systems".

19 3/30/01 All Plan effectiveness determinations revisions indicate the following revisions do not reduce the level of effectiveness of the procedure or REP:

Intent change. Re-paginated. Revised phone numbers. Revised initial notification form to standardize within TVAN and meet new NEI PI requirements to the NRC. Revised PAR chart to meet requirements of RTM 96 Vol. 1 Rev. 4. Revised follow-up form to reflect changes in PAR chart.

20 4/25/01 All Plan effectiveness determinations revisions indicate pg. 2, 9 the following revisions do not reduce the level of effectiveness of the procedure or REP:

Non-Intent change. Corrected typo.

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 4 of 12 1.0 PURPOSE 1.1 To provide a method for timely notification of appropriate individuals when the Shift Manager (SM) or Technical Support Center (TSC) Site Emergency Director (SED) has determined by WBN EPIP-1 that an incident has occurred which is classified as a GENERAL EMERGENCY.11 1.2 To provide a method for periodic reanalysis of the current situation by the SED to determine whether the GENERAL EMERGENCY should be terminated or continued.

2.0 RESPONSIBILITY The SED who is initially the SM (or other SM onsite during the emergency) or designee (Unit Supervisor, US) until properly relieved by the TSC SED, has the responsibility and authority for implementation of the actions in this instruction.'10 1' 3.0 INSTRUCTIONS 3.1 Upon determining that existing conditions are classified as a GENERAL EMERGENCY according to WBN EPIP-1 (independent evaluations by crew members may be beneficial), the SED, or designee, will:11 0

1.

DIRECT Shift Personnel to activate the Emergency Paging System (EPS) to staff the TSC and Operations Support Center (OSC). Shift Personnel should confirm activation and provide the 20 minute printed report to the SM for review.

NOTE 1 IF the EPS system fails, call the ODS ringdown or (5-571-1700) and have him activate the EPS.

NOTE 2 IF the above methods of activating the EPS fail, Shift Personnel must use the Radiological Emergency Response Call Lists to staff the TSC and OSC.

This list is located in the EPS Manual near the terminal.

0]

2.

COMPLETE Appendix A and B, Notification Information.

0

3.

ANNOUNCE to the crew: "A General Emergency is being declared based on I will be the Site Emergency Director, all support and job assignments must be authorized through me."

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 5 of 12 3.0 INSTRUCTIONS (continued) 0

4.

IF Assembly Alarm has not been activated, NOTIFY Security (CAS) that assembly and accountability is to be conducted.

SOUND the assembly alarm AND INITIATE WBN EPIP-8,"Personnel Accountability and Evacuation".

01

5.

ANNOUNCE to the plant: "ATTENTION ALL SITE PERSONNEL.

ATTENTION ALL SITE PERSONNEL. A GENERAL EMERGENCY has been declared based on All plant personnel report to assembly areas for accountability. Staff the TSC and OSC." (Repeat) 0

6.

NOTIFY the ODS direct by ODS Ringdown or 5-751-1700 or 5-751-2495 and PROVIDE the information from Appendix A.

IF the ODS cannot be contacted within 10 minutes, then directly notify Rhea County, Meigs County, McMinn County, and the Tennessee Emergency Management Agency (TEMA) of the classification.

Rhea County EMA (Alternate)

Meigs County EMA (Alternate)

McMinn County EMA (Alternate)

Tennessee EMA (Alternate)

(Alternate) 9-775-2505 9-775-7828 9-1-423-334-3211 9-1-423-334-5268 9-1-423-744-2724 9-1-423-744-2721 9-1-800-262-3300 9-1-615-741-0001 9-1-800-262-3400

-_(TIME)

____(TIME)

-_(TIME)

(TIME)

-_(TIME)

(TIME)

___(TIME)

(TIME)

(TIME) o

7.

FAX Appendix A to the ODS. (No. pre-programmed or 5-751-8620.)

o

8.

CALL RADCON Lab and SAY: "We are in a General Emergency, implement WBN EPIP-14 and CECC EPIP-9."

o

9.

IF there are personnel injuries, IMPLEMENT EPIP-10, "Medical Emergency Response".

0 10 IF there is a security threat, IMPLEMENT EPIP-1 1, "Security and Access Control".

0l

11.

NOTIFY Duty Plant Manager, and PROVIDE the Appendix A information (SEE duty list for telephone numbers). The Duty Plant Manager will call the Plant Manager or his alternate.

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 6 of 12 3.0 INSTRUCTIONS (continued)

El

12. EVALUATE the need to implement EPIP-16, "Initial Dose Assessment for Radiological Emergencies," for a dose projection if radioactivity is being released through normal plant release paths.

o

13. NOTIFY the NRC by the NRC designated phone (ENS) of plan activation.

NOTE NRC notification should be made as soon as practicable, but within one hour of "GENERAL EMERGENCY' declaration. Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center. The following commercial numbers are for the NRC Operations Center:3,13 9-1-301-816-5100 (MAIN) 9-1-301-951-0550 (BACKUP) 9-1-301-816-5151 (FAX) o

14. NOTIFY NRC Resident Inspector by CALLING 1776 and PROVIDING the information on Appendix A.

El

15. REEVALUATE conditions using WBN EPIP-1 as necessary. IF conditions are under control, INITIATE actions identified in WBN EPIP-1 3, "Termination of the Emergency and Recovery."

E]

IF other plant conditions warrant the need for followup information, COMPLETE the Followup Notification Form, Appendix C, and NOTIFY the TSC/CECC (if it is staffed) or NOTIFY the ODS direct by ODS Ringdown or No. 5-751-1700 or 5-751-2495 and PROVIDE the information.

IF the ODS cannot be contacted within 10 minutes, the Tennessee Emergency Management Agency is to be notified of the information by calling 9-1-800-262-3300 or 9-1-615-741-0001 or 9-1-800-262 3400.2 El

16. FAX Appendix C to the ODS. (No. pre-programmed or 5-751-8620.)

CAUTION: If there is any possibility of a radiological release, do not send personnel into areas of unknown radiological conditions without first contacting RADCON.

El

17. ENSURE applicable notifications/actions required by SPP-3.5 and SPP-3.1 have been made.

El

18. SEND the completed WBN EPIP-5 and associated documentation to the Emergency Preparedness (EP) Manager. The EP Manager shall forward documentation to DCRM for storage as appropriate.

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 7 of 12

4.0 REFERENCES

4.1 Interfacing Documents SPP-3.5 Regulatory Reporting Requirements SPP-3.1 Corrective Action Program WBN-EPIP-1 Emergency Plan Classification Flowchart WBN-EPIP-2 Notification of Unusual Event WBN-EPIP-3 Alert WBN-EPIP-4 Site Area Emergency WBN-EPIP-1 0 Medical Emergency Response WBN-EPIP-1 1 Security and Access Control WBN-EPIP-1 3 Termination of the Emergency and Recovery WBN-EPIP-1 6 Initial Dose Assessment for Radiological Emergencies CECC-EPIP-9 Emergency Environmental Radiological Monitoring Procedures 4.2 Other Documents Response Technical Manual (RTM) 96 Vol. 1, Rev. 4 10 CFR 50.72 Immediate Notification Requirements for Operating Nuclear Power Reactors NUREG 0654, FEMA-REP-1, Rev. 1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants.

ANSI N18.7-1976 10 CFR 20, Standards for Protection From Radiation EPA 400-R-92-001, Manual of Protective Action Guides and Protective Actions for Nuclear Incidents Implementation of New EAL Protective Action Guides and Protective Actions for Nuclear Incidents CECC-EPIP-8 Dose Assessment Staff Activities During Nuclear Plant Radiological Emergencies

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 8 of 12 5.0 APPENDICES Appendix A, Notification Information Appendix B, Protective Action Recommendation Guidance Appendix C, Followup Information Form 6.0 RECORDS 6.1 QA Record Entire WBN EPIP-5, when the REP is activated, is a QA Record.

6.2 Non-QA Records All EPIP-5 records generated during the course of a drill/exercise will be assembled By the EP Manager and stored appropriately.

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 9 of 12 APPENDIX A (Page 1 of 1)

INITIAL NOTIFICATION FORM 1,8 GENERAL EMERGENCY r-THIS IS A REAL EVENT F-- THIS IS A DRILL This is NAME There has been a GENERAL EMERGENCY declared at Watts Bar Nuclear affecting:

El Unit 1 Event Declared:

F-- Unit 2 Time:

Date:

EAL Designator (e.g., Fission Product Barrier Matrix):

Brief Description of the Event:

Radiological Conditions:

r-No Abnormal Releases Offsite ER Airborne Release Offsite E] Liquid Release Offsite F-1 Release Information Not Known at this time The following Protective Action Recommendation is provided E-1 Recommendation 1 - Evacuate 2 mile radius and 10 miles downwind and shelter remainder of 10 mile EPZ.

E-Recommendation 2 - Evacuate 2 mile radius and 5 miles downwind and shelter remainder of 10 mile EPZ.

Meteorological Conditions are:

Wind Speed:

m.p.h.

Wind Direction From:

degrees F

Ask, "Please repeat the information you have received to ensure accuracy."

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 10 of 12 APPENDIX B (Page 1 of 1)

PROTECTIVE ACTION RECOMMENDATION 4,,6.7.8,9,12 Note 1: If conditions are unknown utilizing the flowchart, then answer NO.

(General Emergenc)

Declared HE a ED CONTIr

  • Modify p on availa]

Imonitorii

  • Locate ar hot spots.

5 miles is the ProjectedNO or Measured Dose Greater than PAG Table 1 Limits YES

  • 4UE ASSESSMENT rotective actions based ble plant and field ig information.

id evaluate localized RECOMMENDATION 1 EVACUATE 2 miles radius and 10 miles downwind AND SHELTER remainder of 10 mile EPZ I

RECOMMENDATION 2 EVACUATE 2 mile radius and 5 miles downwind AND SHELTER remainder of 10 mile EPZ TABLE I Protective Action Guides TYPE LIMIT Measured 3.9E-6 microCi/cc of Iodine 131 or 1 REM/hr External Dose Projected 1 REM TEDE or 15 REM Thyroid CDE 6

A A

F J

A

GENERAL EMERGENCY EPIP-5 Revision 20 Page 11 of 12 APPENDIX C (Page 1 of 1)

WBN FOLLOWUP INFORMATION FORM GENERAL EMERGENCY O

"THIS IS A REAL EVENT" or 0

"THIS IS A DRILL."

"This is at the Watts Bar Nuclear Plant.

This is followup information regarding the General Emergency at Watts Bar:

Unit 1

[3 Unit 2 M."

"Reactor:

Shutdown 0

At power "The Plant conditions are:

Stable 03 Deteriorating

[

"Followup information: (e.g., key events, status changes)

6.

"Evacuation of nonessential site personnel

7.

"The radiological conditions are:

"O No Abnormal Release Offsite 01 "o

Airborne Release Offsite 0

8.

"Additional Rad information: (e.g., release is ongoing: Yes 0 No 03 "

Liquid Release Offsite Release Information Not Known."

duration)

9.

"The meteorological conditions are: Wind speed:

Wind direction from:

it

10.

"The following protective action recommendation is provided:"

O3 Recommendation 1 O3 Recommendation 2

11.

"The event terminated at:

/

Time Date

12.

11 "Please repeat the information you have received to ensure accuracy."

I Signature Date WBN 11

1.
2.
3.
4.

5.

13.

Signature Date

EPIP-5 WBN GENERAL EMERGENCY Revision 20 Page 12 of 12 SOURCE NOTES Page 1 of 2

' NRC IE Information Notice No. 89-89 2 NRC IE Information Notice No. 86-97 3 NRC IE Information Notice No. 86-28 4 NRC IE Information Notice No. 83-28 5 MC-850321809004, MSC-00956, NCO-920030366 6 NIR-0588, DV-851601F 00001.

7 MC-840827005037, MSC-02402.

8 MC-840827005005, MSC-02376, NCO-920030986 9 MC-840719003003, MSC-00700, NCO-920030221 10 MC-840827005035A, MSC-2400

" ANSI N18.7-1976 12 390/93-64A 13 NRC Administrative Letter 94-04 Event Notification Worksheets Emergency Communications System Telephone Numbers to the NRC Operations Center and Regional Offices Criteria For Protective Action Recommendations For General Emergencies Monitor readings included in Logic Diagram for Protective Action Recommendations App. B, Note 3 Include sheltering and immediate Protective Action.

Appendix B (Page 1 of 1) Recommendation 2 and Note 1 Initiating Conditions.

Revision to Instructional Notes. Appendix B (Page 1 of 1) Notes 1 through 5.

Range of Protective Action Recommendations by the Site Emergency Director. Appendix A (Page 1 of 1) Number 9. Appendix B (Page 1 of 1) Protective Action Recommendation Guidance.

Recommendations 1 through 9.

CNTMT Rad Monitor Levels used in Protective Action Recommendations. Appendix B (Page 1 of 1)

Note 3.

SED duties that can not be delegated. Section 2.0 responsibility. Also see EPIPs 6 and 15.

EPIPs will contain the following elements.

Subsection 5.3.9.3: 01POI 10 CFR 20 revision made to the PAR chart.

Change of NRC Operations Center commercial telephone and fax numbers.

FILING INSTRUCTIONS EPIP-7 EPIP-7, Revision 13 EPIP-7, Revision 14 Remove Insert

TENNESSEE VALLEY AUTHORITY WATTS BAR NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURES EPIP-7 ACTIVATION AND OPERATION OF THE OPERATIONS SUPPORT CENTER (OSC)

Revision 14 Unit 0 QUALITY RELATED PREPARED BY:

Frank L. Pavlechko (Type Name)

SPONSORING ORGANIZATION:

Emergency Planning APPROVED BY:

Frank L. Pavlechko EFFECTIVE DATE: 4/25/01 LEVEL OF USE: REFERENCE

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 2 of 57 REVISION LOG (Page 1 of 3)

Revision Effective Pages Description of Revision Number Date Affected I

0 N/A New WBN Supersedes IP-7.

EPIP 1

02/10/93 4

Added OSC Teams Coordinator, OSC Power Stores Coordinator, DCRM Representative, TSC Coordinator to response organization.

Removed note about RADCON staffing issues.

4 Added 3.5 section on call out list.

5 Added OSC Teams Coordinator Personnel Pool Log.

6 Added NUREG 0654 and NUREG 0696 and 10 CFR 50, App. E 8

references.

Added page 2 to Appendix A, Alt. OSC Layout. Changed all 11 Attachments to Appendices.

Added OSC Mgr Briefing items to Appendix D.

18,19 Added deactivation responsibilities to checklists.

17,22,28,31,3 3,35,37,39,40 47 Added Appendix Q, OSC Personnel Coordinator Checklists.

Added OSC Power Stores Coordinator Checklists.

Added Work Control Boardwriter Checklists.

Added RADCON Boardwriters Checklists.

Added DCRM Coordinator checklists.

2 08/16/93 All Editorial (non-intent) and format changes. Repetitive non-used information removed. New OSC Team Briefing/Debriefing Form added. Source notes added to the procedure. Revised RADCON Briefers' responsibilities. Non-pager contacts for Asst. OSC Manager reduced. TSC Coordinator position discontinued due to lack of need for the position. OSC Logkeeper Appendix was repeated twice, one of the Appendix was removed. Contact information for Maintenance personnel added to the OSC Teams Coordinator position. Nuclear Stores duties enhanced.

3 10/04/93 6

OSC equip., supplies, and procedures will be replenished following a drill, exercise or emergency.

21,22,23 Change Briefing Form to dispatch teams out of OSC.

4 09/02/94 All Added Fitness For Duty note in Section 3.2.3, A. Added WBN EPIPs 12, 15, and 16 to the references section. Changed briefing form, Appendix F, to move OSC Managers signature to front of the form. Added responsibilities to Appendices G, K, N, and 0. Other editorial changes were made. Added optional OSC RADCON Briefer's Emergency Response Teams Staging Area orientation to Appendix H. Added responsibility of faxing Emergency Response Teams board status to Main Control Room to Appendix L.

CN-1 1/17/95 7,55 Source note referencing the capabilities of the OSC was added to the text.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 3 of 57 REVISION LOG (Page 2 of 3)

Revision Effective Pages Description of Revision Number Date Affected 5

4/21/96 3,11,19,20,22, Minor editorial changes concerning eating and drinking in the OSC, 24,46, notification of non-pager wearing responders, changes to OSC 52,54 roster and additions to OSC Teams Coordinator's responsibilities.

Phone number revisions.

6 10/10/96 3, 4, 5, 6, 7, 9, The following non-intent and editorial revisions were made: Shift 13, 14, 19, 24, Clerk revised to Shift Personnel to reflect additional trained 26, 27, 31, 33, responders on shift, enhanced OSC activation instructions, added 35, 37, 38, 39, pager number to ERO call list, revised organizational title as 40, 41, 42, 44, needed, when to card in on the assembly card readers revised, and 45, 48, 49, 51, staffing of the OSC, redundant material/information removed, 53, 55 typographical errors corrected, fitness for duty instructions enhanced, activation time for minimum staffing of the OSC included, SM replaced SOS, non-QA records instructions enhanced, additional duty added to App. G, App. V added to the procedure, mainframe computer reference replaced with Curator, and editorial and grammatical enhancements made to assist human factoring.

CN-1 2/15/97 9, 38, 53 Operational responsibility added to Appendix L and T. Typographic error corrected on appendix list.

CN-2 2/10/98 3,5, 8,15, 22, Satellite phone, NP-STD-1.6 changed to SPP-1.2 for FFD, key 34 check-off for briefers, App. J removed "initiate" fire response.

7 6/30/98 All Non-intent Changes. Incorporated Change Notices 1 & 2. SM FAX

  1. changed. Alternate OSC number revised.

8 2/28/99 All Non-intent change. Revised ERFDS to ICS and referenced OSC alternate locations in Appendix C.

9 10/21/99 All Non-intent change. Developed new landscape tables for App L and P to replace scanned tables. Added step to OSC clerk's responsibilities (App L) to ensure all sign roster.

10 02/07/00 All Non-intent changes. Revised APP. F OSC Team Briefing/Debriefing Form per corrective actions for PER-00-000177-000. Added steps to Appendix I, Initial Activation Checklist and Operational Responsibilities. Corrected typo on Appendix L. Added step to Appendix M, Operational Responsibilities. Revised Appendix P pg. 3 of 3 to enhance OSC Teams Dispatch.

11 06/14/00 All Non-intent changes. Removed REX references and replaced it with HIS-20. Added wording to OSC Mgr., Assistant OSC Mgr.,

OPS Advisor and Nuclear Stores Coordinator responsibilities/titles to reflect wording in the REP. Corrected one typo and text alignments. Identified removal of QA records from MDB to EQB to resolve problems identified in PER98061 0. This revision also corrects problems from WBN PER006394.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 4 of 57 REVISION LOG (Page 3 of 3)

Revision Effective Pages Description of Revision Number Date Affected 12 01/24/01 All Plan effectiveness determination reviews indicate the following Pg. 11,13,42 revisions do not reduce the level of effectiveness of the procedure or REP:

Revised locations of alternate OSC to Team Room (App. A).

Added additional position to OSC minimum staffing to support REP activities and standardize staffing across TVAN (App. C).

Added ARW column to OSC team coordinator's checklist (App. P).

Non-intent change.

13 3/30/01 All Plan effectiveness determination reviews indicate the following Pg.

revisions do not reduce the level of effectiveness of the procedure 9,13,14,48 or REP:

Intent change. Revised minimum staffing requirements in the OSC to include the chemistry advisor.

Non-intent change. Corrected number sequence on page 9.

Non-intent change Added organization column to OSC team coordinator's checklist (App. P) 14 4/25/01 All Plan effectiveness determination reviews indicate the following Pg. 2, 54 revisions do not reduce the level of effectiveness of the procedure or REP:

Intent revision to delete removal of QA Records located in the MDB Vault as a result of Corrective Action 3 in WBNPER 980610. This action for flooding is no longer required due to engineering re evaluation.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 5 of 57 1.0 PURPOSE1,2,3 This procedure provides instructions for the Operations Support Center (OSC) activation, organization, operation, termination, and deactivation.

2.0 RESPONSIBILITY1,2 The OSC Manager and OSC staff are responsible for activation, operation and deactivation of the OSC.

3.0 INSTRUCTION '2 3.1 General At ALERT, SITE AREA EMERGENCY, or GENERAL EMERGENCY classifications, the OSC Manager will report directly to the OSC and shall be responsible for implementing this Procedure.

3.2 Initiating Conditions 3.2.1 The OSC is to be activated and operated when an emergency is declared and classified as an ALERT, a SITE AREA EMERGENCY, or a GENERAL EMERGENCY.

3.2.2 This Procedure may be activated at any other time as deemed necessary by the Site Emergency Director.

3.2.3 The Shift Manager (SM) will activate the OSC by announcing the emergency condition by one or more of the following methods.

A.

Plant Public Address (PA) announcement.

NOTE:

The Radiological Emergency Response Organization Call List is handled in accordance with the TVA Fitness For Duty Program.

B.

Shift personnel will normally activate the Emergency Paging System (EPS) or contact the persons designated on the Radiological Emergency Response Organization Call List.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 6 of 57 3.0 INSTRUCTION (CONTINUED)

C.

OSC personnel can also contact additional responders/replacements by phone utilizing the Emergency Response Organization Call List available in the OSC and Appendix V.

D.

Target activation time for minimum OSC staffing is approximately 60 minutes.

E.

IF the normal phone system and radio systems are not functioning, the satellite phone system will be used as described in SOI-100.01.

3.3 Activation of the OSC 3.3.1 The OSC Manager shall assume responsibility for implementing this Procedure and directing OSC personnel and activities.

3.3.2 Personnel with OSC Emergency Preparedness assignments REPORT to their response positions, (SEE Appendix A, OSC Layout, and Appendix B, Alternate OSC Layout). Activation of the facility is required at the ALERT OR higher emergency classification or at the discretion of the Site Emergency Director.

3.3.3 Other plant staff the OSC Manager determines to be necessary to support OSC functions will be called:

(1) OSC Clerk (2) Maintenance/Craft personnel as needed (3) Operations personnel as needed (4) RADCON personnel as needed (5) Transmission/Power Supply Group personnel as needed (6) Others, as needed.

3.4 Required OSC Actions 3.4.1 OSC organization (Appendix B), staff actions and responsibilities are provided in Appendices C-T.

3.4.2 OSC responders will complete all of the applicable steps contained in the appropriate Appendices.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 7 of 57 3.0 INSTRUCTION (CONTINUED) 3.4.3 Plant procedures should be followed whenever possible. Should a situation arise where normal procedures would be inappropriate, action will be performed as determined by the OSC Manager. Nonconformance with plant procedures should be documented and action/steps taken. Also, deviations may warrant initiation of a Problem Evaluation Report (PER) or other Corrective Action Plan (CAP).

3.5 Emergency Response Organization Call List The WBN Emergency Preparedness Manager shall maintain the Emergency Response organization call list listing key OSC personnel by Emergency Response Organization Title, name, home and work telephone numbers and pager numbers. The call list will be updated at least quarterly with input by the appropriate section/group supervisors.

The list will be available to shift personnel to use in case of the failure of the Emergency Paging System.

3.6 Long-Term Operation Additional personnel will be called in at the request of the OSC Manager to provide coverage or to ensure 12-hour or shorter shifts in the OSC. The OSC Manager will coordinate these call-ins with Nuclear Security to facilitate site access.

3.7 Termination and Deactivation 3.7.1 Deactivation will be implemented using WBN EPIP-13, "Termination of the Emergency and Recovery," when plant conditions are such that: (1) the emergency has been terminated; (2) the OSC has been deactivated; and (3)

OSC personnel have been relieved of emergency response duties.

3.7.2 All records generated during the operation of the OSC will be reviewed by the OSC Manager and forwarded to the Emergency Preparedness Manager.

3.7.3 All equipment and usable supplies will be returned to their storage locations.

3.7.4 All equipment, supplies and procedures will be replenished in the OSC following a drill, exercise or emergency by applicable groups as assigned in WBN EPIP-12, "Emergency Equipment and Supplies."

LE 4.0 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8

4.9 REFERENCES

TVA Nuclear Power Radiological Emergency Plan (NP REP)

WBN-EPIP-6 Activation and Operation of the Technical Support Center WBN-EPIP-8 Personnel Accountability and Evacuation WBN-EPIP-1 0 Medical Emergency Response WBN-EPIP-12 Emergency Equipment and Supplies WBN-EPIP-13 Termination of the Emergency and Recovery WBN-EPIP-14 Radiological Control Response WBN-EPIP-15 Emergency Exposure Guidelines WBN-EPIP-16 Initial Dose Assessment for Radiological Emergencies ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 8 of 57

.0 INSTRUCTION (CONTINUED) 3.8 Records 3.8.1 QA Records NONE 3.8.2 Non-QA Records The appendices and checklist in this procedure are necessary to demonstrate key actions during an emergency or NRC evaluated exercise(s) and are considered Non-Quality Assurance (QA) records.

All original records generated during the course of an emergency drill/exercise will be assembled by the Emergency Preparedness Manager and stored appropriately.

3

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS, Revision 14 SUPPORT CENTER (OSC)

Page 9 of 57

4.0 REFERENCES

4.10 Tennessee Valley Authority Nuclear Power Radiological Emergency Plan (REP) 4.11 SPP-1.2, Fitness For Duty 4.12 NUREG 0654, FEMA-REP-1, Rev. 1, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in support of Nuclear Power Plants 4.13 NUREG 0696, Functional Criteria for Emergency Response Facilities, Final Report 4.14 Title 10 Code of Federal Regulations, Part 50, Appendix E 4.15 ANSI Standard N 18.7-1976 4.16 SOI-100.01 Communications Systems 5.0 APPENDICES Appendix A Appendix B Appendix C Appendix D Appendix E Appendix F Appendix G Appendix H Appendix I Appendix J OSC Layout OSC Organization Chart OSC Manager Checklist OSC Manager Briefing Outline Assistant OSC Manager Checklist OSC Team Tracking/Debriefing Form OSC RADCON Supervisor Checklist OSC RADCON Briefer Checklist OSC Operations Advisor Checklist OSC Fire Protection Advisor Checklist N->

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 10 of 57 5.0 APPENDICES (continued)

Appendix K Appendix L Appendix M Appendix N Appendix 0 Appendix P Appendix Q Appendix R Appendix S Appendix T Appendix U Appendix V OSC Chemistry Advisor Checklist OSC Clerk Checklist OSC Briefing Team Checklist OSC Industrial Safety Advisor Checklist OSC Nuclear Security Advisor Checklist OSC Teams Coordinator Checklist OSC Nuclear Stores Coordinator Checklist Work Control Boardwriter Checklist RADCON Boardwriter Checklist DCRM Coordinator Checklist WBN OSC Roster Emergency Responder Notification Form

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 11 of 57 APPENDIX A (Page 1 of 2)

OPERATIONS SUPPORT CENTER LAYOUT Elevation 713 Radcon Lab Area

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 12 of 57 APPENDIX A (Page 2 of 2)

WBN ALTERNATE OPERATIONS SUPPORT CENTER LAYOUT Elevation 729, Plant Team Conference Room

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 13 of 57 APPENDIX B (Page 1 of 1)

OPERATIONS SUPPORT CENTER ORGANIZATION OPERATIONS SUPPORT CENTER ORGANIZATION RADCON Board Writer

(*) Denotes minimum staffing position(s) per NUREG 0654.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 14 of 57 APPENDIX C (Page 1 of 4)

OSC MANAGER INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/

ENTER keycard into the Accountability Badge Reader.

/

SIGN in OSC on the staffing chart and put on position badge.

SIGN the OSC Roster. (Appendix U)

ESTABLISH a log of activities and communications.

CALL the SED in the TSC and OBTAIN an update of emergency conditions.

RELOCATE to OSC Alternate location (Main Office Building Team Conference room) if OSC is not habitable.

NOTE: The location of the Alternate OSC/RADCON Lab will depend on inplant radiological conditions. The TSC RADCON Manager, after consultation with the SED, will make the decision on location transfer. Possible locations that will be considered are the Alternate OSC in the Main Office Building and the Relay Room 755' level next to the Control Room and the TSC or the WBN Training Center.4 ENSURE minimum staffing requirements for the OSC are met.

OSC Manager RADCON Supervisor (onshift)

__Chemistry Advisor Mechanical Maintenance Supervisor or Briefer Electrical Maintenance Supervisor or Briefer I&C Maintenance Supervisor or Briefer ENSURE OSC support personnel are notified as needed. This includes anyone who is needed to mitigate the incident. SED can authorize personnel onsite who have not been REP trained.

BRIEF OSC on personnel, radiological and plant conditions and expected actions. Use Appendix D as a guide.

I I

I

/

I

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 15 of 57 APPENDIX C (Page 2 of 4)

OSC MANAGER INITIAL OSC ACTIVATION CHECKLIST

/_

BRIEF the OSC regarding the OSC and initial information.

I_

INFORM the TSC of encountered plant conditions and the status of any emergency actions already in progress.

CONFIRM that the OSC is staffed with qualified personnel and operational.

(Will be up to discretion of OSC Manager. Minimum staffing positions must be met.)

/_

INFORM the SED that the OSC is operational.

I_

REQUIRE OSC personnel to use WBN EPIP-7 checklists to perform their assigned duties.

DETERMINE the location and function of persons/teams currently and previously tasked by the TSC/Main Control Room and ensure assignment of Team Tracking Letters.

ESTABLISH shift rotations to fill the OSC positions IF duration is expected to exceed 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

I_______

I________

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 16 of 57 APPENDIX C (Page 3 of 4)

OSC MANAGER OPERATIONAL RESPONSIBILITIES Demonstrate command and control of the OSC throughout the emergency.

Brief the OSC staff on current conditions, as needed.

Update the SED and TSC Maintenance Manager as needed.

Authorize OSC personnel to form emergency response teams.

Direct the dispatching of emergency response teams (Medical Emergency Response Teams, emergency repair teams, search and rescue teams, fire protection teams, Post Accident Sampling Teams, radiological monitoring teams, damage assessment teams, and others as necessary.)

Brief, track and coordinate Emergency Response teams which are being dispatched by the Control Room.

Ensure that team activities are continually prioritized and synchronized with the TSC.

Coordinate with the SED, TSC RADCON Manager, and OSC RADCON Supervisor authorizing exposures in excess of occupational limits. (Use WBN EPIP-1 5).

Coordinates maintenance teams and ensures they have received proper briefings and are all accompanied by a Radcon Technician (as necessary).

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 17 of 57 APPENDIX C (Page 4 of 4)

OSC MANAGER OPERATIONAL RESPONSIBILITIES Coordinate with the SED, TSC RADCON Manager, and OSC RADCON Supervisor in the issuance of KI. (Use WBN EPIP-14).

Provide supplemental staffing for the OSC as needed.

Initiate long-term 24 hour/day operation.

Relocate the OSC as habitability conditions dictate.

Deactivate the OSC when directed by the SED.

(Ensure that all assigned tasks have been completed or terminated as needed, and all emergency response teams have been properly debriefed.)

Review OSC records to ensure completeness and accuracy prior to collection by the WBN Emergency Preparedness Manager.

Maintain log of communications and activities.

Provide adequate turnover when a shift change occurs.

DEACTIVATION RESPONSIBILITIES Terminate in accordance with WBN EPIP-13, "Termination of the Emergency and Recovery."

Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Assists in forming re-entry and recovery plans.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 18 of 57 APPENDIX D (Page 1 of 2)

OSC MANAGER BRIEFING OUTLINE The following may be used as a guide for OSC Manager briefings:

1.

"This is a real emergency. This is a real emergency." OR "This is a drill. This is a drill. We need to treat this exercise as if it were a real emergency."

2.

'This is _____.

l am the OSC Manager."

"The OSC was activated at ____hours."

"The TSC (is/is not) activated.___________

Director."

is the Site Emergency

3.

"The following is a summary of conditions at this time:

Emergency Classification:

Date

_Notification of Unusual Event

-Alert

_Site Area Emergency

_General Emergency Event

Description:

Rt~at.j*--Unit I Status-Unit 2 Time Updated RCS Pres.

RCS Temp.

PZR Level ESF STATUS Time Event Started:

Primary Plant Condition:

Mode:

1 2

3 4

5 6

(circle one)

Electrical Lineup:

Description of any abnormal lineup YES NO YES NO YES NO YES NO YES NO DGIA Operating? DG2A Operating?

DGIB Operating? DG2B Operating? Offsite Pwr Avail.?

Major Mechanical Problems:

Major Electrical Problems:

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 19 of 57 APPENDIX D (Page 2 of 2)

OSC MANAGER BRIEFING OUTLINE

4.

"We are analyzing the work that was in progress at the time of the incident to determine if work should be continued, escalated, postponed or discontinued."

5.

"Our plan of action at this time is to

6.

"Please maintain an orderly atmosphere in the OSC. Listen to briefings and make information flow to the appropriate organizations."

7.

"The status of Emergency Response teams in the field is (Examples: Fire, Medical, damages, repairs..... ) More information will be provided as it becomes available."

8.

"This is a real emergency. This is a real emergency." OR "This is a drill. This is a drill."

Recorded by:

Time:

Date:

Major Instrument and Control Problems:

Environmental Problems High Rad Areas:

Toxic Gas:

High Press. Steam:

Other:

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 20 of 57 APPENDIX E (Page 1 of 3)

ASSISTANT OSC MANAGER INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time:

/_

ENTER keycard into the Accountability Badge Reader.

/_

SIGN OSC Staffing Chart and PUT ON position badge.

/

SIGN the OSC Roster (Appendix U).

/_

ENSURE Plant Status Board is initially completed.

/_

ESTABLISH logbook and communications.

I/

ENSURE that qualified (properly trained) OSC personnel are "signed-in" on the OSC Staffing Chart and the OSC Roster.

/_

REQUEST checklist completion status from OSC personnel. (Checklists are not optional.)

I/

CONTACT the following non-pager carrying OSC Support personnel:

1. OSC Clerk/Logkeeper
2. Communications Support (as needed)
3. Computer Support (as needed)

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 21 of 57 APPENDIX E (Page 2 of 3)

ASSISTANT OSC MANAGER OPERATIONAL RESPONSIBILITIES Assist the OSC Manager in providing direction and control in the OSC.

Maintain communications with the TSC.

Oversee the operations of the OSC Teams and coordinate supporting activities.

Assign TSC developed task(s) to the team briefer(s) and ensure emergency teams are properly briefed using Appendix F, OSC Team Briefing/Debriefing Form.

Authorize the dispatching of emergency response teams (includes signing briefing form, Appendix F).

Ensure emergency teams are properly debriefed, in a timely manner, using Appendix F, OSC Team Briefing/Debriefing Form.

Ensure the Plant Status Board, Emergency Response Team Tracking Boards, and OSC Staffing Chart are kept current.

Coordinate with OSC RADCON Supervisor and Operations Advisor as needed regarding OSC Team activities (determine if teams need RADCON or Operations support).

Authorize issuance of equipment and document issuance as necessary.

Assist in authorizing emergency exposures and the issuance of KI for emergency response teams.

Maintain log of communications and activities.

Provide adequate turnover when a shift change occurs.

Assist the OSC Manager in coordinating shift changes and 24 hour/day OSC operations as needed.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 22 of 57 APPENDIX E (Page 3 of 3)

ASSISTANT OSC MANAGER DEACTIVATION RESPONSIBILITIES Ensures all teams are accounted for.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

Assists in forming re-entry and recovery plans.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 23 of 57 APPENDIX F (Page 1 of 2)

WATTS BAR NUCLEAR PLANT OSC TEAM BRIEFING/DEBRIEFING FORM Task

Description:

Describe problem or task, drawings, known facts, precautions, etc.

Task Location Inform OSC Manager of Team Request From TSC Assign to Briefing Team: Lead Briefer:

Heads-up to Briefer(s):

- Ops

-RADCON

-Safety

_Other

_Enter Team Information on OSC Team Tracking Board Task Team TepmrLeader Members SSN Discipline (IM, MM, etc.)

Operations RADCON Briefing By:

Lead Briefer: Init RADCON Init Description of Problems

-Radiation Work Permit (RWP)

Procedures to be Used

_RADCON Support Tools Needed

-Hazards Between OSC and Work Location Equipment Needed

-Route to/from Work Area Clearance Required (Hold Orders)

-Contact Briefer prior to returning from field Ops Support

-List (Read) debriefing questions to be asked

-Safety Evaluation of Job Copy of Briefing Form given to team with Tele #s

_ Key(s) needed for job Maintain routine contact with team while in the field.

Method of

__TSC Results Hotline (x8611)

-Messenger Communication:

_Pager # _Phone

_Radio (Channel:-.-)

Radio Sensitive Area? __Yes _No (BP-364)

RADCON RADCON Requirements:

/

RWP Required: __Yes No If yes, RWP #

init/time SCBA_

Respirator__

Dressout Other Emerg Exposure Apprl. (EPIP-15 by SED)

Yes-(

REM) No_ N/A_

KI Approval (By TSC RADCON Manager or designee) Yes-No_

N/A_

OSC Mgr FINAL APPROVAL to release team I

___Team Necessary init/time

_Radiological Conditions have not changed since briefing

_Announce to OSC areas: "Is there any reason that we should not dispatch this team at this time?"

TEAM:

Assistant OSC Mgr

/

init/time Lead Briefer

/

in it/time I

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 24 of 57 APPENDIX F (Page 2 of 2)

WATTS BAR NUCLEAR PLANT OSC TEAM BRIEFING/DEBRIEFING FORM Briefer Task Complete:

/

Inform OSC Manager of results (Including any damage assessments) init/time Inform TSC TAT of results (x861 1)

Team Ldr Debriefing

- Was Assignment Completed?

Yes No init/time

_Observations/Damage Assessment from the field (list below)

_Equipment status Briefer

_Hazards (actual or potential)

S__Radiological Conditions init/time

_Unusual Sounds, etc.

_Other information

_Personnel Directed to OSC Teams Coordinator

_Recommendations from field team

_Debriefing Conducted By:

_Summary Provided to Briefer

-Update OSC Team Tracking Board

_Send personnel back to OSC Teams Coordinator

_Summary Provided to OSC Manager (Give this sheet to the OSC Manager.)

OSC Mgr TSC Notified:

/

-Team results provided to TSC Maintenance Manager init/time NOTES: (OBSERVATIONS/DAMAGE ASSESSMENTS/RECOMMENDATIONS)

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 25 of 57 APPENDIX G (Page 1 of 3)

OSC RADCON SUPERVISOR INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/_

ENTER keycard into the Accountability Badge Reader.

/_

SIGN in on the OSC Staffing Chart and PUT ON position badge.

/_

SIGN the OSC Roster. (Appendix U)

/_

ESTABLISH a log of communications and activities.

/_

ESTABLISH communications with the TSC RADCON Manager.

/_

ESTABLISH communications with the RADCON Lab Supervisor.

/_

ENSURE adequate RADCON staffing available for emergency response (dosimetry support, RWP support, boardwriter, clerical).

/_

CONTROL eating and drinking in the OSC until habitability has been established.

/_

ENSURE habitability surveys are current for the OSC areas, TSC, and Control Room and assembly areas as listed in WBN EPIP-8.

/_

ASSIGN HIS-20 computer operator.

/_

ENSURE that RADCON Techs are called in from home to provide staffing as required by WBN EPIP-14.

/_

LOCATE all RADCON persons/teams currently and previously tasked and ensure they are tracked on the Emergency Response Teams Board.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 26 of 57 APPENDIX G (Page 2 of 3)

OSC RADCON SUPERVISOR OPERATIONAL RESPONSIBILITIES 0

Provide and coordinate RADCON resources as necessary.

Provide direction to the RADCON Lab.

Ensure RADCON Teams are dispatched through the OSC. (Tracked on Emergency Response Teams Board.)

0 Ensure emergency response teams have adequate RADCON/dosimetry coverage.

0 Brief the OSC Manager and OSC Staff of radiological conditions as needed.

0 Provide immediate radiological information to OSC staff as conditions change.

0 Brief the TSC RADCON Manager of the RADCON resources and radiological conditions as needed.

Ensure "Environmental Problems" segment of Plant Status Board is correct.

Ensure that all predressed OSC staging area teams are issued proper dosimetry and have been evaluated for radiological access.

Provide assistance to the OSC Manager as needed.

Periodically check habitability of TSC, OSC, and Control Room, if radiological conditions warrant.

0 Administer KI to emergency response teams according to WBN EPIP-14.

(Forward Potassium Iodine Issue Report, to the TSC RADCON Manager.)

Maintain log of communications and activities.

Provide adequate turnover when a shift change occurs.

0 Log-on to Integrated Computer System (ICS).

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 27 of 57 APPENDIX G (Page 3 of 3)

OSC RADCON SUPERVISOR DEACTIVATION RESPONSIBILITIES Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

Assists in forming re-entry and recovery plans.

Ensures outlining emergency response groups (i.e., line crews, warehouse) have dosimetry and are being protected throughout the emergency.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 28 of 57 APPENDIX H (Page 1 of 4)

OSC RADCON BRIEFER INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/____

/____

/____

I/___

I I/___

I/___

ENTER keycard into the Accountability Badge Reader.

SIGN in OSC on the Staffing Chart.

SIGN the OSC Roster. (Appendix U)

ESTABLISH a log of communications and activities.

NOTIFY the OSC RADCON Supervisor of arrival.

ACCESS RADCON Party Line (4103) as necessary.

ENSURE that personnel reporting to the OSC teams staging area are briefed as time allows using page 3 of 4 of Appendix H as an orientation for responders.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 29 of 57 APPENDIX H (Page 2 of 4)

OSC RADCON BRIEFER OPERATIONAL RESPONSIBILITIES Provide radiological technical assistance to the Briefing Teams.

Provide radiological conditions analysis of the job assigned to the emergency response teams.

Assist with portions of the OSC Team Briefings.

Complete applicable portions of Appendix F, the OSC Team Tracking/Briefing/Debriefing Form.

Ensure radiological data is collected and reported back to the OSC in an expeditious manner for planning and prioritizing further emergency response activities.

Ensure TLDs are collected and processed from returning team members.

Assist in the administration of KI according to WBN-EPIP 14.

Maintain log of communications and activities.

Provide adequate turnover when a shift change occurs.

0 Ensures that the radiological information on the OSC status board is accurate.

Ensures that personnel reporting to the OSC Teams Staging Area are briefed as time allows using page 3 of 4 of Appendix H as an orientation for responders.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 30 of 57 APPENDIX H (Page 3 of 4)

OSC RADCON BRIEFER EMERGENCY RESPONSE TEAMS STAGING AREA ORIENTATION (RADCON will brief responders as conditions allow on the contents of this list.)

Stay continuously aware of REP status and in plant conditions.

Plan contingencies when assigned a team (anticipate needs and hazards) prior to entering accident area.

Communicate with briefers on a regular basis. Be aware of radio dead spots in the Plant (e.g., El. 676, RHR pump rooms). Perform functional check of radio and equipment prior to entering Auxiliary Building or accident area. Use repeat backs for effective transfer of information. BP-364 lists radio sensitive areas of the plant.

Perform applicable pathway surveys to and from work location.

Relay data promptly and frequently to the OSC! This information is critical in assessing plant conditions and protection of personnel. Consideration should be given to designating a runner to telephone data if necessary.

If on pathway the team encounters a field of >1000 mrem/HR advise the OSC.

If when arriving to destination team encounters a field of >1000 mrem/HR, return to lower dose area and advise OSC.

Stay together as a team for accountability.

In-plant conditions are dynamic, OSC will continually advise the team of any changes while in the field.

If for some reason the scope of the job changes while in the field, notify the OSC.

Note any unusual plant conditions (frisker increases, liquid leaks, poor visibility, etc.), advise OSC.

Use appropriate techniques to reduce exposure and maximize safety.

0 When in the field, use available supplies in RADCON cabinets if needed.

0 Contact RADCON briefer upon completion of task.

0 Primary accident condition RWPS are available; please familiarize yourself with them, RADCON will brief the team on the RWP.

0 If possible, keep a written log of team activities while in the field.

0 Contact RADCON or OSC for return route in the event of change of event conditions, etc.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 31 of 57 APPENDIX H (Page 4 of 4)

OSC RADCON BRIEFER DEACTIVATION RESPONSIBILITIES Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

Assists in forming re-entry and recovery plans.

WBN P-7

,ision 14

e 32 of 57 Date
___

Inits/Time

/

/

/

/

/

/____

I

/

/

ENTER into the Accountability Badge Reader.

SIGN in on the OSC Staffing Chart.

SIGN the OSC Roster. (Appendix U)

ESTABLISH a log of activities and communications.

ESTABLISH communications with the TSC Operations Manager for updates and to obtain Operations support.

CALL-IN AUOs\\Operations personnel from offshift to support OSC activities (Minimum of 3 AUOs is usually needed in the OSC).

ESTABLISH communications with the Control Room Communicator via the Control Room party-line.

LOG ON to Integrated Computer System (ICS) terminal.

ANNOUNCE on the portable radio: "AUO's report to the OSC." (repeat)

ACTIVATION AND OPERATION EPI OF THE OPERATIONS Re\\

SUPPORT CENTER (OSC)

Pac Appendix I (Page I of 2)

OSC OPERA TIONS AD VISOR INITIAL OSC ACTIVATION CHECKLIST

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 33 of 57 Appendix I (Page 2 of 2)

OSC OPERA TIONS AD VISOR CHECKLIST OPERATIONAL RESPONSIBILITIES Direct AUO's to maintain a log, and listen to the Operations Party Line to remain current on Plant Status.

Provide plant operations advice to support the OSC Manager.

Provide Operational advice to support the entire OSC, including Briefing Teams as needed. (Additional AUOs can be used to assist in briefing teams.)

Provide personnel for any operations actions that may be required while in the field.

SKeep the TSC Operations Manager, and Operations Communicator appraised of the OSC Team activities while in the field.

Operate ICS terminal in the OSC as needed.

Ensure the OSC Plant Status Board is correct.

Maintain log of communications and activities.

Provide adequate turnover when a shift change occurs.

DEACTIVATION RESPONSIBILITIES Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

Assists in forming re-entry and recovery plans.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 34 of 57 APPENDIX J (Page 1 of 2)

OSC FIRE PROTECTION AD VISOR INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/____

/____

/____

/____

I/___

ENTER keycard into the Accountability Badge Reader.

SIGN in on the OSC Staffing Chart.

SIGN OSC Roster. (Appendix U)

ESTABLISH a log of activities and communications.

ESTABLISH communications with the Fire Operations Unit or the Fire Station to provide plant status updates.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 35 of 57 APPENDIX J (Page 2 of 2)

OSC FIRE PRO TEC TION AD VISOR OPERATIONAL RESPONSIBILITIES Monitor plant status and fire response.

0 Support WBN-EPIP-10, Medical Emergency Response, as needed.

Initiate and provide first response for hazardous material containment.

Initiate personnel search and rescue in hazardous areas.

0 Maintain log of communications and activities.

Provide adequate turnover when a shift change occurs.

DEACTIVATION RESPONSIBILITIES 0

Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

0 Assists in forming re-entry and recovery plans.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 36 of 57 APPENDIX K (Page 1 of 2)

OSC CHEMIS TRY AD VISOR INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/____

I/___

/____

/____

/____

/____

I____

ENTER keycard into the Accountability Badge Reader.

SIGN in on the OSC Staffing Chart.

SIGN OSC Roster. (Appendix U)

ESTABLISH a log of activities and communications.

ESTABLISH communications with the TSC Chemistry Manager.

ESTABLISH communications with Chemistry Lab staff.

CALL the assigned Chemistry Engineer to support OSC operations.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 37 of 57 APPENDIX K (Page 2 of 2)

OSC CHEMIS TR YAD VISOR OPERATIONAL RESPONSIBILITIES Provide and coordinate Chemistry personnel needed to support the OSC.

Provide Chemistry technical content in emergency team briefings as necessary.

Dispatch the Post-Accident Sampling (PAS) team as directed by the TSC.

Maintain a communications link with the TSC Chemistry Manager.

Maintain log of communications and activities.

Provide adequate turnover when a shift change occurs.

Provide/assist in obtaining Release/Pathway information as needed.

Provide Chemistry data (primary and secondary) of initiating conditions and provide ongoing Chemistry information.

DEACTIVATION RESPONSIBILITIES Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

Assists in forming re-entry and recovery plans.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 38 of 57 APPENDIX L (Page 1 of 3)

OSC CLERK INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/

/____

/____

I

/____

ENTER keycard into the Accountability Badge Reader.

SIGN in on the OSC Staffing Chart.

SIGN the OSC Roster. (Appendix U)

ESTABLISH a log of activities and communications.

NOTIFY other staff to report to the OSC as determined by the OSC Manager.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 39 of 57 APPENDIX L (Page 2 of 3)

OSC CLERK OPERATIONAL RESPONSIBILITIES Ensure the OSC Status Boards are continuously updated to reflect current plant conditions.

0 Ensure OSC responders have signed the OSC roster.

Ensure a log is maintained of all important OSC activities.

0 In the event of a Site Wide Evacuation, notify the OSC RADCON Supervisor that this is a non-radiation worker position.

0 Collect and maintain all original copies of OSC generated records.

0 Provide records to the WBN Emergency Preparedness (EP) Manager when the OSC is deactivated.

0 Maintain log of communications and activities.

0 Provide OSC team status reports to the control room on a periodic basis.

Provide adequate turnover when a shift change occurs, and utilizes Appendix V to activate additional OSC responders.

0 Assist OSC responders in obtaining their TLDs.

DEACTIVATION RESPONSIBILITIES Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

Assists in forming re-entry and recovery plans.

I Priority Team Task Location Lead Briefer/Team Leader/RC Tech L. Briefer:_____

T. Leader:______

RC Tech:______

L. Briefer:_____

T. Leader:______

RC Tech.:________

L. Briefer: _________

T. Leader:______

RC Tech:______

L. Briefer:_____

T. Leader:______

RC Tech:______

L. Briefer:_____

T. Leader:______

RC Tech: ________

L. Briefer:_____

T. Leader:______

RC Tech:______

L. Briefer:_____

T. Leader:______

RC Tech:______

L. Briefer:_____

T. Leader:______

RC Tech:______

Comments/Status Time Briefed Time Time Out IIn Time Debriefed EPIP WBN ACTIVATION AND OPERATION OF THE OPERATIONS SUPPORT CENTER (OSC)

Revision 14 Page 40 of 57 APPENDIX L (Page 3 of 3)

EMERGENCY RESPONSE TEAMS TO: SM in MCR (Simulator for Drills)

FAX to the SM (8463) and TSC (8365)

FROM:

/

/

(For drills FAX to the SM/simulator at x8363).

WBN PIP-7 evision 14 age 41 of 57 Date:

Inits/Time

/

/____

/____

I/___

I/___

ENTER keycard into the Accountability Badge Reader.

SIGN in on the OSC Staffing Chart.

SIGN the OSC Roster. (Appendix U)

ESTABLISH a log of communications and activities.

REPORT any conditions in the plant which may be related to the emergency condition.

ACTIVATION AND OPERATION E

OF THE OPERATIONS R

SUPPORT CENTER (OSC)

P APPENDIX M (Page I of 2)

OSC BRIEFING TEAM INITIAL OSC ACTIVATION CHECKLIST

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 42 of 57 APPENDIX M (Page 2 of 2)

OSC BRIEFING TEAM OPERATIONAL RESPONSIBILITIES Provide Mechanical, Electrical, and Instrument technical expertise.

Notify Mechanical, Electrical, Instrument Foremen to report with crews to the OSC Staging Area.

Evaluate job conditions (including RADCON, Fire Operations, and Operational aspects of the task) and analyze the necessary precautions and methods best suited to safe performance of the task.

Brief the OSC Teams based on the analysis of the job.

Track, communicate and monitor safety of the OSC Teams while in the field.

Debrief the OSC Teams after completion of the task.

Complete applicable portions of Appendix F, OSC Team Briefing/Debriefing Form.

Operates Curator computer as needed to provide OSC team briefing information.

0 Maintain log of communications and activities.

0 Provide adequate turnover when a shift change occurs.

DEA C TI VA TION RESPONSIBILITIES 0

Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 43 of 57 APPENDIX N (Page 1 of 2)

OSC INDUSTRIAL SAFETY AD VISOR INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time I

ENTER keycard into the accountability card reader.

/

SIGN the OSC Staffing Chart.

/_

SIGN the OSC Roster. (Appendix U)

/_

ESTABLISH a log of communications and activities.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 44 of 57 APPENDIX N (page 2 of 2)

OSC INDUSTRIAL SAFETY ADVISOR OPERATIONAL RESPONSIBILITIES Ensure the OSC Manager/OSC Staff are aware of safety hazards that could affect emergency response activities.

Assist Briefing Teams in preparing applicable portions of Appendix F, OSC Team Tracking/Debriefing Form.

Assist Briefing Teams in briefing process. Ensure teams have adequate safety apparel and equipment to complete emergency team assignments.

Assist in obtaining/procuring adequate safety equipment.

Assist in the team debriefing process as needed.

Ensure safety hazard information obtained from returning teams flows back into the OSC in a timely expeditious manner. Incorporate significant information into the prioritizing and emergency team briefing process.

Maintain log of communications and activities.

Provide adequate turnover when a shift change occurs.

DEACTIVATION RESPONSIBILITIES Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 45 of 57 APPENDIX 0 (Page 1 of 1)

OSC NUCLEAR SECURITYAD VISOR INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/_

ENTER keycard into the Accountability Badge Reader.

/_

SIGN in on the OSC Staffing Chart.

/

SIGN the OSC Roster. (Appendix U)

I ESTABLISH a log of communications and activities.

OPERATIONAL RESPONSIBILITIES Ensure the OSC Manager/OSC Staff are aware of security hazards that could affect emergency response activities.

0 Provide assistance to briefing teams as needed.

0 Ensure security provides expeditious emergency entries and exits for teams dispatched from the OSC.

Ensure adequate staffing is available to support WBN EPIP-8, "Personnel Accountability and Evacuation," when implementing assembly and accountability or evacuations.

0 Provide Security support for search and rescue operations and other necessary emergency response actions.

0 Maintain log of communications and activities.

0 Provide adequate turnover when a shift change occurs.

DEA CTI VA TION RESPONSIBILITIES Ensures all teams are accounted for and properly debriefed.

0 Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 46 of 57 APPENDIX P (Page 1 of 3)

OSC TEAMS COORDINATOR INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/_

ENTER keycard into the Accountability Badge Reader.

/_

SIGN in on the OSC Staffing Chart.

/

SIGN the OSC Roster. (Appendix U)

/_

ESTABLISH a log of communications and activities.

/_

USE Page 3 of 3 of this Appendix to organize an OSC Teams Staging Area.

I/

ENSURE OSC tool kits have been moved from the Toolroom in the Maintenance Shop to the OSC Teams Staging Area.

I/

ENSURE the following minimum number of personnel come to the prestaging area (these numbers are approximate depending on plant conditions):

4 Electrical Maintenance 6 Mechanical Maintenance 2 I&C Maintenance 3 AUOs from Main Control Room Kitchen (or from home)

NOTE:

This is not a comprehensive list. The emergency may or may not require all of these positions to be prestaged. This is only a suggested list.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 47 of 57 APPENDIX P (Page 2 of 3)

OSC TEAMS COORDINATOR OPERATIONAL RESPONSIBILITIES Maintain contact with Assistant OSC Manager.

Manage the Emergency Response Team staging area by:

1.

Directing responders (potential OSC teams) to check-in with the HIS-20 Operator.

2.

Requiring all potential OSC team members to dress out.

3.

Prepare emergency responders to be dispatched.

Ensure that OSC briefers know who is available in the OSC Teams Staging Area by periodically distributing lists of personnel awaiting assignments.

Ensure that every team is debriefed upon returning.

DEACTIVATION RESPONSIBILITIES Ensures all teams are accounted for and properly debriefed.

Ensures all logs and team briefing forms are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

ACTIVATION AND OPERAk.

N OF THE OPERATIONS SUPPORT CENTER (OSC)

EPIP-7 Revision 14 Paae 48 of 57 Name SSN Og 5 APPENDIX P (Page 3 of 3)

OSC TEAMS COORDINATOR Name SSN Org TLD#

Margin EPT309 RRT01 0 HPRT 363.002 OSC Team Correct ARW Comments (MEG, (RAD)

OSC Respirator SCBA (A,B, etc.)

Eyewear

MIG, Teams Available etc.)

Training I

I I

I I.

I I

I I

I I

I I

+

I I

I I

I I

I

+

F I

I

-

I I

I I

+

+

F I

I I

t I

I I

+/-

4-F I

I 4

I I

I 1

1 1-F I

I

+

I I

I T

I t

t I

I I

+

F I

I I

+

I I

I

4.

1 S _____

A ______

J. ______

J L

L _______

L _____

I ____

L WBN t

t F

I

+

4 F

I 1

4.

1

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 49 of 57 APPENDIX Q (Page I of 1)

OSC NUCLEAR STORES COORDINA TOR INITIAL OSC ACTIVATION CHECKLIST Date:_

Inits/Time

/

ENTER keycard into the Accountability Badge Reader.

/

SIGN in on the OSC Staffing Chart.

I SIGN OSC Roster. (Appendix U)

I ESTABLISH a log of communications and activities.

OPERATIONAL RESPONSIBILITIES Provides coordination between Power Stores and the OSC.

Provides materials as expeditiously as possible for emergency response activities.

Operates mainframe computer to determine materials availability.

DEACTIVA TION RESPONSIBILITIES Ensures all records (anything written down during the OSC activation) are completed and signed.

Leave all papers at your station which will be collected and properly stored by WBN Emergency Preparedness.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 50 of 57 APPENDIX R (Page 1 of 2)

WORK CONTROL BOARDWRITER INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/

/____

/____

/

/

ENTER keycard into the Accountability Badge Reader.

SIGN in on the OSC Staffing Chart.

SIGN the OSC Roster. (Appendix U)

ESTABLISH a log of communications and activities.

PROVIDE a status of current work control plant activities to the OSC for immediate analysis to:

Determine if any ongoing work is related to the emergency.

Determine if current jobs should be continued, expedited or stopped.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 51 of 57 APPENDIX R (Page 2 of 2)

WORK CONTROL BOARDWRITER OPERATIONAL RESPONSIBILITIES Maintain contact on control room party line on x4102.

Maintain OSC status boards.

DEACTIVATION RESPONSIBILITIES Ensures all records (anything written down during the OSC activation) are complete and signed.

Leave all papers at work station which will be collected and properly stored by WBN Emergency Preparedness.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 52 of 57 APPENDIX S (Page I of 2)

RADCON BOARDWRITER INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/____

/_____

/____

I I/___

ENTER keycard into the Accountability Badge Reader.

SIGN in on the OSC Staffing Chart.

SIGN the OSC Roster. (Appendix U)

ESTABLISH a log of communications and activities.

ESTABLISH contact on the RADCON Party-line by dialing 4103.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 53 of 57 APPENDIX S (Page 2 of 2)

RADCON BOARDWRITER OPERATIONAL RESPONSIBILITIES Maintains the radiological status boards by providing a radiological sequence of events.

Maintains copies of radiological status board as conditions change.

Notifies the OSC RADCON Supervisor of changes in radiological conditions.

Maintains contact on RADCON Party Line (4103).

Maintains radiological status elevation maps to provide a clear status of radiological conditions at all times.

Maintains a clear status of eating and drinking in the OSC areas on the Radiological Status Board.

DEA C TI VA TION RESPONSIBILI TIES Ensures all records (anything written down during the OSC activation) are complete and signed.

Leaves all papers at work station which will be collected and properly stored by WBN Emergency Preparedness.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 54 of 57 APPENDIX T (Page 1 of 1)

DCRM COORDINA TOR INITIAL OSC ACTIVATION CHECKLIST Date:

Inits/Time

/____

/____

/_____

/____

/____

I ENTER keycard into the Accountability Badge Reader.

SIGN in on the OSC Staffing Chart.

SIGN the OSC Roster (Appendix U).

ENSURES that current WBN EPIP-7 copies are available for all OSC responders.

ESTABLISH a log of communications and activities.

ENSURE OSC Manager has a controlled copy of the WBN-EPIPs on his desk.

OPERATIONAL RESPONSIBILITIES Provides DCRM expertise as needed.

Provides drawings, documents, vendors manuals as requested by OSC.

In the event of a Site Wide Evacuation, notify the OSC RADCON Supervisor that this is a non-radiation worker position.

Assists in OSC logistics as requested.

DEACTIVATION RESPONSIBILITIES Ensures all records (anything written down during the OSC activation) are complete and signed.

Leaves all papers at work station which will be collected and properly stored by WBN Emergency Preparedness.

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 55 of 57 APPENDIX U (Page I of 1)

OSC ROSTER Date of OSC Activation WBN EP Records Coordinator

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 56 of 57 Appendix V Page 1 of 1 EMERGENCY RESPONDER NOTIFICATION FORM Fitness for Duty Person Calling Date Department Name Time Time Alcohol 5 Hrs.

Fit for Duty Official Called Needed to Prior to Report Duty Comments Report (Y/N)

(Y/N) 4 4-

+

t t

4 4-

+

f t

4 4-

+

4-4 4-

+

4-4-

4 4-

+

4-4-

4 4*

+

+

1-4

4.
4.

.t 1*

4

+

+

4.

4 4-

+

1*

4 4-4

.1.

I _________

I ______

ACTIVATION AND OPERATION EPIP-7 WBN OF THE OPERATIONS Revision 14 SUPPORT CENTER (OSC)

Page 57 of 57 SOURCE NOTES Page 1 of I 1

MC-840827005001, MSC-02371.

2.

ANSI N18.7-1976 Subsection 5.3.9.3: 01 POI

3.

MSC-02853, NCO-920042521 Revise OSC procedure duties and responsibilities. See entire procedure with all appendices.

Implementing procedures will include the following elements.

Each site will have an OSC.

Communications will be available to the TSC. The OSC will establish and maintain appropriate communications with any team that may enter the plant for assessment or repair.

Alternate OSC locations.

4.

WBPER 98016506