Emergency Plan Implementing Procedures, EPIP-2 (Rev 16), EPIP-3 (Rev 19), EPIP-4 (Rev 19), EPIP-5 (Rev 25), EPIP-7 (Rev 18), EPIP-14 (Rev 15), and EPIP-17 (Rev 20)
ML003754740
Person / Time
Site: Sequoyah  Tennessee Valley Authority icon.png
Issue date: 09/15/2000
From: Salas P
Tennessee Valley Authority
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
-RFPFR
Download: ML003754740 (125)


Text

Tennessee Valley Authority. Post Office Box 2000, Soddy-Daisy, Tennessee 373;&

September 15, 2000 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Gentlemen:

In the Matter of )) Docket Nos. 50-327 Tennessee Valley Authority 50-328 SEQUOYAH NUCLEAR PLANT (SQN) - UNITS 1 AND 2 - EMERGENCY PLAN IMPLEMENTING PROCEDURE (EPIP) REVISIONS In accordance with the requirements of 10 CFR 50, Appendix E, Section V, the enclosure provides the following EPIP:

EPIP Revision Title EPIP-2 16 Notification of Unusual Event EPIP-3 19 Alert EPIP-4 19 Site Area Emergency EPIP-5 25 General Emergency EPIP-7 18 Activation and Operation of the Operations Support Center (OSC)

EPIP-14 15 Radiological Control Response EPIP-17 20 Emergency Equipment and Supplies If you have any questions concerning this matter, please telephone me at (423) 843-7170 or J. D. Smith at (423) 843-6672.

Since:

V'edr'--Sdlas Licensing and Industry Affairs Manager Enclosure cc: See page 2 pvk(

U.S. Nuclear Regulatory Commission Page 2 September 15, 2000 cc: Mr. R. W. Hernan, Project Manager (Enclosure)

U.S. Nuclear Regulatory Commission One White Flint, North 11555 Rockville Pike Rockville, Maryland 20852-2739 NRC Resident Inspector (Enclosure will be provided by Sequoyah Nuclear Plant SQN Document Control Unit) 2600 Igou Ferry Road Soddy-Daisy, Tennessee 37384-3624 Regional Administrator (Enclosure)

U.S. Nuclear Regulatory Commission Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303-3415

TENNESSEE VALLEY AUTHORITY SEQUOYAH NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE EPIP-2 NOTIFICATION OF UNUSUAL EVENT Revision 16 QUALITY RELATED PREPARED/PROOFREAD BY: W. P. Brooks RESPONSIBLE ORGANIZATION: Emergency Preparedness APPROVED BY: John Casey EFFECTIVE DATE: 08/31/2000 Level Of Use: Reference REVISION DESCRIPTION: Intent Change, Editorial changes, Added steps for standardization with WBN, BFN, and Corp., Format change for ease of use. Revisions are not shown due to extent of format changes.

Date 1.0 PURPOSE 1.1 To provide a method for timely notifications of appropriate individuals when the Shift Manager (SM) has determined by EPIP-1 that events have occurred that are classified as a NOTIFICATION OF UNUSUAL EVENT.

1.2 To provide the Site Emergency Director (SED) a method for periodic reanalysis of current conditions to determine whether the NOTIFICATION OF UNUSUAL EVENT should be terminated, continued, or upgraded to a more serious classification.

2.0 REFERENCES

2.1 Interface Documents A. SPP-3.5, "Regulatory Reporting Requirements" B. EPIP-3, "Alert" C. EPIP-4, "Site Area Emergency" D. EPIP-5, "General Emergency" E. EPIP-10, "Medical Emergency Response" F. EPIP-14, "Radiological Control Response" G. CECC EPIP-9, "Emergency Radiological Monitoring Procedures" H. PHYSI-32, "Security Instructions For Members Of The Security Force".

3.0 INSTRUCTION 3.1 ACTIVATION OF THE REP Upon classifying events as a NOTIFICATION OF UNUSUAL EVENT in accordance with EPIP-1, "Emergency Plan Classification Matrix," the SM shall:

[1] ANNOUNCE to Operating Crew:

"A Notification of Unusual Event has been declared based on (Describe the Conditions). I will be the Site Emergency Director." LI FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

Date 3.1 ACTIVATION OF THE REP (Continued)

NOTE ODS should be notified within 5 minutes after declaration of the event

[2] COMPLETE Notification of Unusual Event (NOUE) Notification Form (Page 6). El

[3] NOTIFY ODS.

[a] CALL ODS.

IRindown Line or r 5-751-1700 or 1 5-751-2495I or 1 9-785-1700 Initial Time

[b] READ completed Form (Page 6) to ODS. 3l

[c] FAX ODS NOUE Notification Form (Page 6). El 15-751-8620 FAX 1

[4] IF ODS CANNOT be contacted within 10 minutes of the declaration, THEN

[a] NOTIFY Tennessee Emergency Management Agency (TEMA).

S00-262-3 or 196741-0001 or 1888-616-8091 (satellite)

Initial Time

[b] READ completed Form (page 6) to TEMA. D

[c] FAX TEMA NOUE Notification Form (Page 6). II 9-1-615-242-9635 FAX

[5] ANNOUNCE to plant personnel:

"ATTENTION PLANT PERSONNEL. ATTENTION PLANT PERSONNEL.

A NOTIFICATION OF UNUSUAL EVENT HAS BEEN DECLARED BASED ON (Describethe Conditions), AFFECTING UNIT(s) " []

REPEAT Announcement. El

[6] IF there are personnel injuries, THEN IMPLEMENT EPIP-10, "Medical Emergency Response." []

FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

Date 3.1 ACTIVATION OF THE REP (Continued)

[7] MONITOR radiation monitors.

IF radiation monitors indicate unplanned radiological release, THEN

[a] NOTIFY RADCON Shift Supervisor to EVALUATE implementation of CECC EPIP-9, "Emergency Radiological Monitoring Procedures" and EPIP-14, "Radiological Control Response."

[b] PERFORM Dose Assessment.

NOTIFY Chemistry Shift Supervisor to perform a dose assessment using EPIP-14.

r 7285 Lai or r6348 L or FPager 350-40732

[c] REFER to EPIP-1, Radiological Effluents Section, AND EVALUATE need for additional classifications. El

[8] IF there is a security threat, THEN NOTIFY Security Shift Supervisor to implement PHYSI-32,"Security Instructions For Members Of The Security Force." []

61or5

[9] NOTIFY Plant Management in accordance with SPP-3.5 AND PROVIDE NOUE Notification information. El NOTE I NRC notification should be made as soon as practicable, but within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of "NOTIFICATION OF UNUSUAL EVENT" declaration. Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center.

NOTE 2 Do not dial "1" prior to the number when using ENS phones.

[10] NOTIFY NRC of plan activation via ENS in accordance with SPP-3.5.

r(301) 816-5100 (Main) (301) 951-0550 (Backup) 9-1-(301) 816-5151 (Fax)

Initial Time FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

Date 3.1 ACTIVATION OF THE REP (Continued)

[11] NOTIFY Site Emergency Preparedness as soon as practicable when notification does not interfere with emergency actions or notifications in progress. LI John Casey Work 8 =-7658 Pager 350-20372 Car 9-280-6616 Bill Peggram Work 843-83601 Pager 350-30388 Home 9-842-3020

[12] MONITOR plant conditions AND EVALUATE using EPIP-1, AND

[a] IF plant conditions warrant, THEN UPGRADE to a higher classification AND INITIATE EPIP-3 or EPIP-4 or EPIP-5. LI

[b] IF additional conditions satisfy criteria of other NOUE's OR Conditions warrant a need for follow-up information, THEN COMPLETE NOUE Follow-up Form (page 7), AND REPORT to ODS for State notification at:

or F9-785-17001 Ringdown Line or 15-751-1700 1 or 5-71-249 AND FAX ODS NOUE Follow-up Form (Page 7). 15- 51-8620 FAX I OR-

[c] TERMINATE emergency, when situation no longer exists, by informing ODS and Duty Plant Manager AND COMPLETE NOUE Follow-up Form (Page 7) with Time and Date Event Terminated and FAX to ODS. LI END OF SECTION I FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

NOTIFICATION OF UNUSUAL EVENT NOTIFICATION FORM

1. 0] THIS IS A REAL EMERGENCY EVENT. THIS IS A REAL EMERGENCY EVENT.

OR El THIS IS A DRILL. THIS IS A DRILL.

2. This is at Sequoyah Nuclear Plant.

(Your Name)

3. There has been a NOTIFICATION OF UNUSUAL EVENT declared at Sequoyah Nuclear Plant.

Affecting LI Unit 1 OR El Unit 2 OR El Both Units 1 & 2

4. EAL Designator:
5. Brief Description of Event
6. Plant conditions are: LI Stable 17 Deteriorating
7. Radiological Conditions are:

[] No Abnormal Release Off-site

[] Airborne Release Off-site LI Liquid Release Off-site F1 Release Information Not Known

8. Event Declared: Time: Date:
9. Event Terminated: Time: Date:
10. Protective Action Recommendation: L7 None at This Time.
11. "Please Repeat the Information You Have Received to Ensure Accuracy." 13 FAX TO THE ODS AT 751-8620 AFTER COMPLETING THE NOTIFICATION FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

NOTIFICATION OF UNUSAL EVENT FOLLOW-UP FORM

1. 0] THIS IS A REAL EMERGENCY EVENT. THIS IS A REAL EMERGENCY EVENT.

OR El THIS IS A DRILL. THIS IS A DRILL.

2. This is at Sequoyah Nuclear Plant.

(Your Name)

3. This is Follow-up Information Regarding the NOTIFICATION OF UNUSUAL EVENT declared at Sequoyah Nuclear Plant.

Affecting El Unit 1 OR El Unit 2 OR 1l Both Units 1 & 2

4. Reactor Unit I El Shutdown El At Power Unit 2 El Shutdown El At Power
5. Plant conditions are: 13 Stable E3 Deteriorating
6. Additional EAL Designator (s):
7. The Following Significant Changes in Plant Conditions Have Occurred:
8. The Following Significant Changes in Radiological Conditions Have Occurred:
9. Protective Action Recommendation: El None at This Time
10. Event Terminated: Time: Date:
11. "Please Repeat the Information You Have Received to Ensure Accuracy." LI
12. Name Date Time (Preparer's Name)
13. FAX TO THE ODS AT 751-8620 AFTER COMPLETING THE NOTIFICATION .ll FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

TENNESSEE VALLEY AUTHORITY SEQUOYAH NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE EPIP-3 ALERT Revision 19 QUALITY RELATED PREPARED/PROOFREAD BY: W. P. Brooks RESPONSIBLE ORGANIZATION: Emergqency Preparedness APPROVED BY: John H. Casey EFFECTIVE DATE: 8/31/2000 Level of Use: Reference REVISION DESCRIPTION: Intent Change, Editorial changes, Added steps for standardization with WBN, BFN, and Corp., Format change for ease of use. Revisions not shown due to extent of format changes.

Date 1.0 PURPOSE 1.1 To provide a method for timely notifications of appropriate individuals when the Shift Manager (SM)/Site Emergency Director (SED) has determined by EPIP-1 that events have occurred that are classified as a ALERT.

1.2 To provide the Site Emergency Director (SED) a method for periodic reanalysis of current conditions to determine whether the ALERT should be terminated, continued, or upgraded to a more serious classification.

2.0 REFERENCES

2.1 Interface Documents A. SPP-3.5, "Regulatory Reporting Requirements" B. EPIP-4, "Site Area Emergency" C. EPIP-5, "General Emergency" D. EPIP-6, "Activation and Operation Of The Technical Support Center" E. EPIP-7 "Activation and Operation of the Operations Support Center (OSC)"

F. EPIP-8, "Personnel Accountability And Evacuation" G. EPIP-10, "Medical Emergency Response" H. EPIP-14, "Radiological Control Response" I. EPIP-16, "Termination And Recovery" J. CECC EPIP-9, "Emergency Environmental Radiological Monitoring Procedures" K. PHYSI-32, "Security Instructions For Members Of The Security Force".

3.0 INSTRUCTION

[1] IF TSC is NOT STAFFED, THEN GO TO Section 3.1. (Page 3) 0

[2] IF TSC is OPERATIONAL, (SED transferred to TSC), THEN GO TO Section 3.2. (Page 7). El FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SON

Date 3.1 ACTIVATION OF THE REP BY SM Upon classifying events as an ALERT in accordance with EPIP-1, "Emergency Plan Classification Matrix," the SM shall:

[1] ANNOUNCE to Operating Crew:

"An ALERT has been declared based on (Describethe Conditions).

I will be the Site Emergency Director." El

[2] ACTIVATE Emergency Paging System (EPS), THEN El (SM may delegate these tasks to Operations Clerk if available.

MSS also may be used if necessary.)

[a] CONFIRM response by reviewing 20 minute printed report available in the TSC. El

[b] CALL personnel to staff unanswered positions (Use REP Duty Roster and Call List). El

[3] IF EPS fails, THEN

[a] CALL Operation Duty Specialist (ODS) AT:

Ringdown Line or 5-71700- or r5-751- orl 9-785-1700 AND DIRECT ODS to activate EPS. El

[b] IF EPS still will not activate, THEN (SM may delegate these tasks to Operations Clerk ifavailable.

MSS also may be used if necessary.)

CALL personnel to staff TSC/OSC positions (Use REP Duty Roster and Call List). D

[4] ANNOUNCE to plant personnel:

"ATTENTION PLANT PERSONNEL. ATTENTION PLANT PERSONNEL. AN ALERT HAS BEEN DECLARED BASED ON (Describethe condition), AFFECTING UNIT(s)

ALL TSC AND OSC PERSONNEL REPORT TO THE EMERGENCY FACILITIES IMMEDIATELY." El REPEAT Announcement.

OPS 41-SQN FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS,

Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

NOTE If plant conditions do not warrant personnel accountability at this time, continue to assess the situation and re-evaluate the need for accountability.

[5] MONITOR plant conditions, WHEN plant conditions warrant, THEN

[a] NOTIFY Security Shift Supervisor to implement EPIP-8, "Personnel Accountability and Evacuation."

Wor 1 6568 El

[b] ACTIVATE emergency sirens for personnel assembly. Initial Time NOTE ODS should be notified within 5 minutes after declaration of the event.

[6] COMPLETE ALERT Notification Form (Page 10). II

[7] NOTIFY ODS.

[a] CALL ODS.

Ringdown Line], or 5j-751-1700 or 15-751-249:5 or j 9-785-17001 Initial Time

[b] READ completed Form (Page 10) to ODS. i]

[c] FAX ODS ALERT Notification Form (Page 10). []

I 5-751-8620 FAX]

[8] IF ODS CANNOT be contacted within 10 minutes of the declaration, THEN

[a] NOTIFY Tennessee Emergency Management Agency (TEMA).

8 or 19-1615-741-0001 or 888-616-8091 (satellite)

Initial Time

[b] READ completed Form (Page 10) to TEMA. il

[c] FAX TEMA ALERT Notification Form (Page 10). El I 9-1-615-242-9635 FAX I OPS 41-SQN FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS,

Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

[9] NOTIFY RADCON Shift Supervisor,

[a] STATE "AN ALERT HAS BEEN DECLARED, BASED UPON (Describe the conditions), AFFECTING UNIT(s) 3l"

[b] DIRECT to implement EPIP-1 4, "Radiological Control Response." El

[c] IF radiation monitors indicate unplanned radiological release, THEN DIRECT to EVALUATE implementation of CECC EPIP-9, "Emergency Radiological Monitoring Procedures." []

[10] NOTIFY Chemistry Shift Supervisor,

[a] STATE: "AN ALERT HAS BEEN DECLARED, BASED UPON (Describethe conditions), AFFECTING UNIT(s) - ."290 7285 La~b or 3 Lab or [Pager 350-40732

[b] DIRECT to implement EPIP-14. El

[11] MONITOR radiation monitors.

WHEN indication of an unplanned radiological release, THEN PERFORM Dose Assessment.

[a] NOTIFY Chemistry Shift Supervisor to perform a dose assessment using EPIP-14. El r7285 or 6348ab or [Pager 350-40 7 32

[b] REFER to EPIP-1, Radiological Effluents Section, AND EVALUATE need for additional classifications. El

[12] IF there are personnel injuries, THEN IMPLEMENT EPIP-10, "Medical Emergency Response." El

[13] IF there is a security threat, THEN NOTIFY Security Shift Supervisor to implement PHYSI-32, "Security Instructions For Members Of The Security Force" 164 or 16 FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

[14] NOTIFY Plant Management in accordance with SPP-3.5 AND PROVIDE ALERT Notification Information. El NOTE 1 NRC notification should be made as soon as practicable, but within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of "ALERT" declaration. Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center.

NOTE 2 Do not dial "1" prior to the number when using ENS phones.

[15] NOTIFY NRC of plan activation via ENS in accordance with SPP-3.5.

(301) 816-510 ainI (301) 951-0550 (Backup) 9-1-(301) 816-5151 (Fax)i Initial Time

[16] MONITOR plant conditions AND EVALUATE using EPIP-1 until TSC is staffed, AND

[a] IF plant conditions warrant, THEN UPGRADE to a higher classification AND INITIATE EPIP-4 or EPIP-5. El

[b] IF additional conditions satisfy criteria of other ALERT's OR Conditions warrant a need for follow-up information, THEN COMPLETE ALERT Follow-up Form (Page 11), AND REPORT to ODS for State notification at:

[Ringdown Line or F5-751-17001 or P-751-24951 or 9-785-17001 AND FAX ODS ALERT Follow-up Form (Page 11). 15-751-8620 FAX I END OF SECTON FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

Date 3.2 ACTIVATION OF THE REP BY TSC Upon classifying events as a ALERT in accordance with EPIP-1, "Emergency Plan Classification Matrix," the SED shall:

NOTE If plant conditions do not warrant personnel accountability at this time, continue to assess the situation and re-evaluate the need for accountability.

[1] MONITOR plant conditions, IF plant conditions warrant, THEN

[a] DIRECT TSC Security Manager or Security Shift Supervisor to implement EPIP-8, "Personnel Accountability and Evacuation." El

~3~flor

[b] DIRECT SM to ACTIVATE emergency sirens for personnel assembly.

Initial Time

[2] IF ALERT Classification has been declared by SM, THEN GO TO Step [6] OR appropriate Step based on SM turnover. El NOTE ODS should be notified within 5 minutes after declaration of the event.

[3] COMPLETE ALERT Notification Form (Page 10). LI

[4] NOTIFY ODS.

[a] CALL ODS.

5 I or 575-2 or -1700 Initial Time

[b] READ completed Form (Page 10) to ODS. LI

[c] FAX ODS ALERT Notification Form (Page 10). LI 5-751-8620 FAX I 41-SON FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS

Date 3.2 ACTIVATION OF THE REP BY TSC (Continued)

[5] IF ODS CANNOT be contacted within 10 minutes of the declaration, THEN

[a] NOTIFY Tennessee Emergency Management Agency (TEMA).

or 19-1-615-741-0001 1 or 888-616-8091 (satellite)I

[j9-1-800-262-330 Initial Time

[b] READ completed Form (Page 10) to TEMA.

[c] FAX TEMA ALERT Notification Form (Page 10). II 1 9-1-615-242-9635 FAX I NOTE The Dose Assessment function is transferred to the CECC once they are staffed.

[6] MONITOR radiation monitors.

WHEN indication of an unplanned radiological release, THEN PERFORM Dose Assessment.

[a] DIRECT TSC Chemistry Manager or Chemistry Shift Supervisor to perform a dose assessment using EPIP-14, "Radiological Control Response". El 7285 Lab] or F6348 Lab or I Pager 350-40732

[b] DIRECT TSC RADCON Manager to evaluate need to implement CECC EPIP-9 "Emergency Radiological Monitoring Procedures." El

[c] REFER to EPIP-1, Radiological Effluents Section, AND EVALUATE need for additional classifications. El

[7] IF there are personnel injuries, THEN IMPLEMENT EPIP-10, "Medical Emergency Response." El

[8] IF there is a security threat, THEN DIRECT TSC Security Manager or Security Shift Supervisor to implement PHYSI-32,"Security Instructions For Members Of The Security Force." El or 6568 FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

Date 3.2 ACTIVATION OF THE REP BY TSC (Continued) within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of NOTE 1 NRC notification should be made as soon as practicable, but "ALERT" declaration. Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center.

NOTE 2 Do not dial "1" prior to the number when using ENS phones.

[9] ENSURE NRC has been notified of plan activation via ENS in accordance with SPP-3.5.

(301) 816-5100 (Main)I (301) 951-0550 (Backup) 9-301)86-51(ax~I Initial Time

[10] MONITOR plant conditions AND EVALUATE using EPIP-1, AND

[a] IF plant conditions warrant, THEN UPGRADE to a higher classification, AND INITIATE EPIP-4 or EPIP-5. El

[b] IF additional conditions satisfy criteria of other ALERT's OR Conditions warrant a need for follow-up information, THEN COMPLETE ALERT Follow-up Form (Page 11), AND REPORT to CECC Director for State notification at:

RingdownLine or 5-751-1614 or 5-751"1680 AND FAX CECC ALERT Follow-up Form (Page 11) 5-751-1682 FAXI OR

[c] IF situation no longer exists, THEN TERMINATE emergency per EPIP-16, "Termination and Recovery," AND 0 COMPLETE ALERT Follow-up Form (Page 11) including Time and Date Event Terminated and FAX to CECC. []

1 END OF SECTION FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

ALERT NOTIFICATION FORM

1. 03 THIS IS A REAL EMERGENCY EVENT. THIS IS A REAL EMERGENCY EVENT.

OR 13 THIS IS A DRILL. THIS IS A DRILL.

2. This is at Sequoyah Nuclear Plant.

(Your Name)

3. There has been a ALERT declared at Sequoyah Nuclear Plant.

Affecting 17 Unit 1 OR E3 Unit 2 OR E3 Both Units 1 & 2

4. EAL Designator:
5. Brief Description of Event
6. Plant conditions are: E3 Stable E3 Deteriorating
7. Radiological Conditions are:

1] No Abnormal Release Off-site

-1Airborne Release Off-site El Liquid Release Off-site

-1Release Information Not Known

8. Event Declared: Time: Date:
9. Event Terminated: Time: Date:
10. Protective Action Recommendation: 17 None at This Time.
11. "Please Repeat the Information You Have Received to Ensure Accuracy." E3 FAX TO THE ODS AT 751-8620 AFTER COMPLETING THE NOTIFICATION FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SON

EPIP-3 SQN ALERT Rev. 19 Page 11 of 11 ALERT FOLLOW-UP FORM

1. 0 THIS IS A REAL EMERGENCY EVENT. THIS IS A REAL EMERGENCY EVENT.

OR El THIS IS A DRILL. THIS IS A DRILL.

2. This is at Sequoyah Nuclear Plant.

(Your Name)

3. This is Follow-Up Information Regarding the ALERT declared at Sequoyah Nuclear Plant Affecting 0I Unit 1 OR LI Unit 2 OR El Both Units 1 & 2
4. Reactor Unit 1 El Shutdown EL At Power Unit 2 El Shutdown El At Power
5. Plant conditions are: El Stable LI Deteriorating
6. Additional EAL Designator (s):
7. Site Assembly and Accountability is on going. El YES El NO OR EL COMPLETED
8. The Following Significant Changes in Plant Conditions Have Occurred:
9. The Following Significant Changes in Radiological Conditions Have Occurred:
10. Protective Action Recommendation: LI None at This Time
11. Event Terminated: Time: Date:
12. "Please Repeat the Information You Have Received to Ensure Accuracy." EL
13. Name Date Time (Preparer's Name)
14. FAX TO THE ODS AT 751-8620 OR CECC at 751-1682 AFTER COMPLETING THE NOTIFICATION El FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

TENNESSEE VALLEY AUTHORITY SEQUOYAH NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE EPIP-4 SITE AREA EMERGENCY Revision 19 QUALITY RELATED PREPARED/PROOFREAD BY: W. P. Brooks RESPONSIBLE ORGANIZATION: Emercqency Preparedness APPROVED BY: John H. Casey EFFECTIVE DATE: 08/31/2000 Level of Use: Reference REVISION DESCRIPTION: Intent Change, Editorial changes, Added steps for standardization with WBN, BFN, and Corp., Format change for ease of use.

Revisions not shown due to extent of format changes.

EPIP-4 SON SITE AREA EMERGENCY Rev. 19 Page 2 of 11 Date 1.0 PURPOSE 1.1 To provide a method for timely notifications of appropriate individuals when the Shift Manager (SM)/Site Emergency Director (SED) has determined by EPIP-1 and the REP Appendix B that events have occurred that are classified as a SITE AREA EMERGENCY.

1.2 To provide the SED a method for periodic reanalysis of current conditions to determine whether the SITE AREA EMERGENCY should be terminated, continued, or upgraded to a more serious classification.

2.0 REFERENCES

2.1 Interface Documents A. SPP-3.5 "Regulatory Reportinp Requirements" B. EPIP-5, "General Emergency C. EPIP-6, "Activation And Operation Of The Technical Support Center D. EPIP-7, "Activation And Operation Of The Operations Support Center" E. EPIP-8, "Personnel Accountability And evacuation" F. EPIP-10, "Medical Emergency Response" G. EPIP-14, "Radiological Control Response" H. EPIP-16, "Termination And Recovery" I. CECC EPIP-9 "Emergency Environmental Radiological Monitoring Procedures" J. PHYSI-32, "Security Instructions For Members Of The Security Force" 3.0 INSTRUCTION

[1] IF TSC IS NOT STAFFED, THEN GO TO Step 3.1 [1]. (Page 3) El

[2] IF TSC IS OPERATIONAL, (SED transferred to TSC), THEN GO TO Step 3.2 [1]. (Page 7) El FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-4 SQN SITE AREA EMERGENCY Rev. 19 Page 3 of 11 Date 3.1 ACTIVATION OF THE REP BY SM Upon classifying events as a SITE AREA EMERGENCY in accordance with EPIP-1, "Emergency Plan Classification Matrix," the SM shall:

[1] ANNOUNCE to Operating Crew:

"A SITE AREA EMERGENCY has been declared based on (Describethe Conditions).

I will be the Site Emergency Director." ED

[2] IF Emergency Paging System (EPS) has not been previously initiated, THEN ACTIVATE EPS AND LI (SM may delegate these tasks to Operations Clerk if available.

MSS also may be used ifnecessary.)

[a] CONFIRM response by reviewing 20 minute printed report available in the TSC. El

[b] CALL personnel to staff unanswered positions.

(Use REP Duty Roster and Call List) LI

[3] IF EPS fails, THEN

[a] CALL Operation Duty Specialist (ODS) AT RingdownLine I or [71700 or 951 or 9-785-1700 AND DIRECT ODS to activate EPS. LI

[b] IF EPS still will not activate, THEN (SM may delegate these tasks to Operations Clerk if available.

MSS also may be used if necessary.)

CALL personnel to staff TSC/OSC positions.

(Use REP Duty Roster and Call List) El

[4] ANNOUNCE to plant personnel:

"ATTENTION PLANT PERSONNEL. ATTENTION PLANT PERSONNEL. A SITE AREA EMERGENCY HAS BEEN DECLARED BASED ON (Describethe Conditions), AFFECTING UNIT(s) __ ALL TSC AND OSC PERSONNEL REPORT TO THE EMERGENCY FACILITIES IIMMEDIATELY." LI REPEAT Announcement. MI FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SON

EPIP-4 SQN SITE AREA EMERGENCY Rev. 19 Page 4 of 11 Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

[5] IF personnel accountability has not been previously initiated, THEN

[a] NOTIFY Security Shift Supervisor to implement EPIP-8 "Personnel Accountability and Evacuation."

6144 or E8

[b] ACTIVATE emergency sirens for personnel assembly.

Initial Time NOTE ODS should be notified within 5 minutes after declaration of the event.

[6] COMPLETE SAE Notification Form (Page 10). El

[7] NOTIFY ODS.

[a] CALL ODS.

Ringdown Line I or 15-751-1700 or 15-751-24951 or 19-785-1700 Initial Time

[b] READ completed Form (Page 10) to ODS. D

[c] FAX ODS SAE Notification Form (Page 10). []

1 5-751-8620 FAX 1

[8] IF ODS CANNOT be contacted within 10 minutes of the declaration, THEN

[a] NOTIFY Tennessee Emergency Management Agency (TEMA) 9-1"800"262-3300 1 °rl 9-1-615-741-00011 or 888-616-8091 (satellite)

Initial Time

[b] READ completed Form (page 10) to TEMA 0i

[c] FAX TEMA SAE Notification Form (Page 10) El I

1 9-1-615-242-9635 FAX FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SON

EPIP-4 SQN SITE AREA EMERGENCY Rev. 19 Page 5 of 11 Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

[9] NOTIFY RADCON Shift Supervisor,

[a] STATE "A SITE AREA EMERGENCY HAS BEEN DECLARED, BASED UPON (Describethe conditions), AFFECTING UNIT(s) _ ." E

[b] DIRECT to implement EPIP-14, "Radiological Control Response." ED

[c] DIRECT to implement CECC EPIP-9, "Emergency Radiological Monitoring Procedures." ED

[10] NOTIFY Chemistry Shift Supervisor,

[a] STATE: "A SITE AREA EMERGENCY HAS BEEN DECLARED, BASED UPON (Describethe Conditions),

AFFECTING UNIT(s) _ " I 7285 Laa or F6348 Lab I or IPager 350-40732

[b] DIRECT to implement EPIP-14. D

[11] MONITOR radiation monitors.

WHEN indication of an unplanned radiological release, THEN PERFORM Dose Assessment.

[a] NOTIFY Chemistry Shift Supervisor to perform a dose assessment using EPIP-14. El S7285 La or r6348 Lab or iPager 350-40732I

[b] REFER TO EPIP-1, Radiological Effluents Section, AND EVALUATE need for additional classifications. []

[12] IF there are personnel injuries, THEN IMPLEMENT EPIP-10, "Medical Emergency Response." El

[13] IF there is a security threat, THEN NOTIFY Security Shift Supervisor to implement PHYSI-32, "Security Instructions For Members Of The Security Force."

J or ET FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-4 SQN SITE AREA EMERGENCY Rev. 19 Page 6 of 11 Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

[14] NOTIFY Plant Management in accordance with SPP-3.5 AND PROVIDE SAE Notification Information. El NOTE 1 NRC notification should be made as soon as practicable, but within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of "SITE AREA EMERGENCY" declaration. Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center.

NOTE 2 Do not dial "1" prior to the number when using ENS phones.

[15] NOTIFY NRC of plan activation via ENS in accordance with SPP-3.5.

(301) 816-5100 (Mai F 951-0550 (Backup) ]

-(301) 9-1-(301) 816-5151 (Fax)

Initial Time

[16] MONITOR plant conditions AND EVALUATE using EPIP-1 until TSC is staffed, AND

[a] IF plant conditions warrant, THEN UPGRADE to a higher classification AND INITIATE EPIP-5. El

[b] IF additional conditions satisfy criteria of other SITE AREA EMERGENCIES OR Conditions warrant a need for follow-up information, THEN COMPLETE SAE Follow-up Form (Page 11), AND REPORT to ODS for State notification at:

Ringdown Line or 5-751-1700 or 5-751-2495 1 or9 5"1700 AND FAX ODS SAE Follow-up Form (Page 11) 15-751-860FA I END OF SECTION :

FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-4 SQN SITE AREA EMERGENCY Rev. 19 Page 7 of 11 Date 3.2 ACTIVATION OF THE REP BY TSC Upon classifying events as a SITE AREA EMERGENCY in accordance with EPIP-1, "Emergency Plan Classification Matrix," the SED shall:

[1] IF personnel accountability has not been previously initiated, THEN

[a] DIRECT TSC Security Manager or Security Shift Supervisor to implement EPIP-8 "Personnel Accountability and Evacuation." El or6

[b] DIRECT SM to ACTIVATE emergency sirens for personnel assembly.

Initial Time

[2] IF Site Area Emergency classification has been declared by SM, THEN GO TO Step [6] OR appropriate Step based on SM turnover. 0]

NOTE CECC Director should be notified within 5 minutes after declaration of the event.

[3] COMPLETE SAE Notification Form (Page 10). El

[4] NOTIFY CECC Director.

[a] CALL CECC Director.

RingdownLi or 5-751-1 i or 1 5-751-1680 Initial Time

[b] READ completed Form (Page 10) to CECC Director. El

[c] FAX CECC SAE Notification Form (Page 10). El 15-751-1682 FAx FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-4 SQN SITE AREA EMERGENCY Rev. 19 Page 8 of 11 Date 3.2 ACTIVATION OF THE REP BY TSC (Continued)

[5] IF CECC Director CANNOT be contacted within 10 minutes of the declaration, THEN

[a] NOTIFY Tennessee Emergency Management Agency (TEMA).

9180262-33 or 19-1-65-741-0001 1 or 1888-616-8091 (satellite)

Initial Time

[b] READ completed Form (Page 10) to TEMA. El

[c] FAX TEMA SAE Notification Form (Page 10). D I 9-1-615-242-9635 FAX 1

[6] DIRECT TSC RADCON Manager to implement CECC EPIP-9 "Emergency Radiological Monitoring Procedures." El NOTE The Dose Assessment function is transferred to the CECC once they are staffed.

[7] MONITOR radiation monitors.

WHEN indication of an unplanned radiological release, THEN PERFORM Dose Assessment

[a] DIRECT TSC Chemistry Manager or Chemistry Shift Supervisor to perform a dose assessment using EPIP-14, "Radiological Control Response." El 7285 L or I6348 Lab or FIager 350-40732

[b] REFER TO EPIP-1, Radiological Effluents Section, AND EVALUATE need for additional classifications. El

[8] IF there are personnel injuries, THEN IMPLEMENT EPIP-10, "Medical Emergency Response." El

[9] IF there is a security threat, THEN DIRECT TSC Security Manager or Security Shift Supervisor to implement PHYSI-32, "Security Instructions For Members Of The Security Force." El 6144or 6 FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-4 SQN SITE AREA EMERGENCY Rev. 19 Page 9 of 11 Date 3.2 ACTIVATION OF THE REP BY TSC (Continued)

NOTE 1 NRC notification should be made as soon as practicable, but within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of "SITE AREA EMERGENCY" declaration. Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center.

NOTE 2 Do not dial "1" prior to the number when using ENS phones.

[10] ENSURE NRC has been notified of plan activation via ENS in accordance with SPP-3.5.

(301) 816-5100 (Main) (301) 951-0550 (Bac 9-1-(301) 816-5151 (Fax)

Initial Time

[11] MONITOR plant conditions AND EVALUATE using EPIP-1, AND

[a] IF plant conditions warrant, THEN UPGRADE to a higher classification, AND INITIATE EPIP-5 El

[b] IF additional conditions satisfy criteria of other SITE AREA EMERGENCY's OR Conditions warrant a need for follow-up information, THEN COMPLETE SAE Follow-up Form (Page 11), AND REPORT to CECC Director for State notification at:

Ringdown Line or 1 16 or 5-751-1680I AND FAX CECC SAE Follow-up Form (Page 11) 5-751-1682 FAXI OR

[c] IF situation no longer exists, THEN TERMINATE emergency per EPIP-16, "Termination and Recovery," AND El COMPLETE SAE Follow-up Form (Page 11) including El Time and Date Event Terminated and FAX to CECC.

I END OF SECTION I FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-4 SON SITE AREA EMERGENCY Rev. 19 Page 10 of 11 SITE AREA EMERGENCY NOTIFICATION FORM

1. El THIS IS A REAL EMERGENCY EVENT. THIS IS A REAL EMERGENCY EVENT.

OR 0] THIS IS A DRILL. THIS IS A DRILL.

2. This is at Sequoyah Nuclear Plant.

(Your Name)

3. There has been a SITE AREA EMERGENCY declared at Sequoyah Nuclear Plant.

Affecting El Unit 1 OR El Unit 2 OR El Both Units 1 & 2

4. EAL Designator:
5. Brief Description of Event
6. Plant conditions are: El Stable El Deteriorating
7. Radiological Conditions are:

El No Abnormal Release Off-site El Airborne Release Off-site El Liquid Release Off-site El Release Information Not Known

8. Event Declared: Time: Date:
9. Event Terminated: Time: Date:
10. The Meteorological Conditions Are: (Use MET Tower elevation 46, alternate elevation 90.)

Wind Speed mph Wind Direction From

11. Protective Action Recommendation: [] None at This Time.
12. "Please Repeat the Information You Have Received to Ensure Accuracy." El FAX TO THE ODS AT 751-8620 AFTER COMPLETING THE NOTIFICATION.

FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-4 SQN SITE AREA EMERGENCY Rev. 19 Page 11 of 11 SITE AREA EMERGENCY FOLLOW-UP FORM

1. El THIS IS A REAL EMERGENCY EVENT. THIS IS A REAL EMERGENCY EVENT.

OR El THIS IS A DRILL. THIS IS A DRILL.

2. This is at Sequoyah Nuclear Plant.

(Your Name)

3. This is Follow-Up Information Regarding the SITE AREA EMERGENCY declared at Sequoyah Nuclear Plant Affecting El Unit 1 OR El Unit 2 OR El Both Units 1 & 2
4. Reactor Unit 1 ED Shutdown El At Power Unit 2 ED Shutdown El At Power
5. Plant conditions are: ED Stable 0] Deteriorating
6. Additional EAL Designator (s):
7. Site Assembly and Accountability is on going. El YES D NO OR D COMPLETED
8. The Following Significant Changes in Plant Conditions Have Occurred:
9. The Following Significant Changes in Radiological Conditions Have Occurred:
10. The Meteorological Conditions Are: (Use MET Tower elevation 46, alternate elevation 90.)

Wind Speed mph Wind Direction From

11. Protective Action Recommendation: 171 None at This Time
12. Event Terminated:Time: Date:
13. "Please Repeat the Information You Have Received to Ensure Accuracy." 0Z
14. Name Date Time (Preparer's Name)
15. FAX TO THE ODS AT 751-8620 OR CECC AT 751-1682 AFTER COMPLETING THE NOTIFICATION ED FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

TENNESSEE VALLEY AUTHORITY SEQUOYAH NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE EPIP-5 GENERAL EMERGENCY Revision 25 QUALITY RELATED PREPARED/PROOFREAD BY: W. P. Brooks RESPONSIBLE ORGANIZATION: Emergiency Preparedness APPROVED BY: John H. Casey EFFECTIVE DATE: 8-31-2000 Level of Use: Reference REVISION DESCRIPTION: Intent Change, Editorial changes, Added steps for standardization with WBN, BFN, and Corp., Format change for ease of use.

Revisions not shown due to extent of format changes.

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 2 of 14 Date 1.0 PURPOSE 1.1 To provide a method for timely notifications of appropriate individuals when the Shift Manager (SM)/Site Emergency Director (SED) has determined by EPIP-1 that events have occurred that are classified as a GENERAL EMERGENCY 1.2 To provide the SED/SM a method for periodic reanalysis of current conditions to determine whether the GENERAL EMERGENCY should be terminated or continued.

2.0 REFERENCES

2.1 Interface Documents A. SPP-3.5 "Regulatory Reporting Requirements" B. EPIP-6, "Activation and Operation of the Technical Support Center" C. EPIP-7, "Activation and Operation of the Operations Support Center" D. EPIP-8, "Personnel Accountability and Evacuation" E. EPIP-10, "Medical Emergency Response" F. EPIP-14, "Radiological Control Response" G. EPIP-16, "Termination and Recovery" H. CECC EPIP-9, "Emergency Environmental Radiological Monitoring Procedures" I. PHYSI-32, "Security Instructions For Members Of The Security Force" 3.0 INSTRUCTION

[1] IF TSC is NOT STAFFED, THEN GO TO Section 3.1. (Page 3) El

[2] IF TSC is OPERATIONAL, (SED transferred to TSC), THEN GO TO Section 3.2. (Page 8) El FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 3 of 14 Date 3.1 ACTIVATION OF THE REP BY SM Upon classifying events as a GENERAL EMERGENCY in accordance with EPIP-1, "Emergency Plan Classification Matrix," the SM shall:

[1] ANNOUNCE to Operating Crew:

"A GENERAL EMERGENCY has been declared based on (Describe the Conditions).

I will be the Site Emergency Director." 0

[2] IF Emergency Paging System (EPS) has not been previously initiated, THEN ACTIVATE EPS AND El (SM may delegate these tasks to Operations Clerk if available.

MSS also may be used if necessary.)

[a] CONFIRM response by reviewing 20 minute printed report available in the TSC. 13

[b] CALL personnel to staff unanswered positions D]

(Use REP Duty Roster and Call List).

[3] IF EPS fails, THEN

[a] CALL Operation Duty Specialist (ODS), AT IRingdown Lne or 15-751-1700] or 17 2495] or F9-785-1700 I AND DIRECT ODS to activate EPS.

[b] IF EPS still will not activate, THEN (SM may delegate these tasks to Operations Clerk if available.

MSS also may be used if necessary.)

CALL personnel to staff TSC/OSC positions (Use REP Duty Roster and Call List). F-FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 4 of 14 Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

[4] ANNOUNCE to plant personnel:

"ATTENTION PLANT PERSONNEL. ATTENTION PLANT PERSONNEL. A GENERAL EMERGENCY HAS BEEN DECLARED BASED ON (Describethe condition), AFFECTING UNIT(s)

ALL TSC AND OSC PERSONNEL REPORT TO THE EMERGENCY FACILITIES IMMEDIATELY."

REPEAT Announcement. El

[5] IF personnel accountability has not been previously initiated, THEN

[a] NOTIFY Security Shift Supervisor to implement EPIP-8, "Personnel Accountability and Evacuation."

6144 or 6568 El

[b] ACTIVATE emergency sirens for personnel assembly.

Initial Time NOTE ODS should be notified within 5 minutes after declaration of the event.

[6] COMPLETE GE Notification Form (Page 13). El

[7] NOTIFY ODS.

[a] CALL ODS.

SRingdown or or 51-1700 or i _751-24951 or 19-785-1:7:00]

Initial Time

[b] READ completed Form (Page 13) to ODS. El D

[c] FAX ODS GE Notification Form (Page 13).

1 5-751-8620 FAXI FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 5 of 14 Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

[8] IF ODS CANNOT be contacted within 10 minutes of the declaration, THEN

[a] NOTIFY Tennessee Emergency Management Agency (TEMA).

I1 00-262-33001 or 1-1-615-741-00 or 888-616-8091 (satellite)

Initial Time

[1] READ completed Form (Page 13) to TEMA. ED

[2] FAX TEMA GE Notification Form (Page 13). []

I 9-1-615-242-9635 FAX

[b] NOTIFY Hamilton County Emergency Management Agency (EMA) AND 9-69 or 2-7777 1or1 20022 Initial Time READ completed Form (Page 13) to Hamilton County EMA AND LI

[c] NOTIFY Bradley County EMA.

19-476-060 or 1 9-476-75111 Initial Time READ completed Form (Page 13) to Bradley County EMA. El

[9] NOTIFY RADCON Shift Supervisor,

[a] STATE "A GENERAL EMERGENCY HAS BEEN DECLARED, BASED UPON (Describethe conditions),

AFFECTING UNIT(s) ." I)I

[b] DIRECT to implement EPIP-14, "Radiological Control Response." LI

[c] DIRECT to implement CECC EPIP-9, "Emergency Radiological Monitoring Procedures". El FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 6 of 14 Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

[10] NOTIFY Chemistry Shift Supervisor,

[a] STATE: "A GENERAL EMERGENCY HAS BEEN DECLARED, BASED UPON (Describethe conditions). AFFECTING UNIT(s) ." ED 7285 Lab] or L6348 Lab I or [Pager 350-40732

[b] DIRECT to implement EPIP-14. El

[11] MONITOR radiation monitors.

WHEN indication of an unplanned radiological release, THEN PERFORM Dose Assessment.

[a] NOTIFY Chemistry Shift Supervisor to perform a dose assessment using EPIP-14 0 or 6 ab or Pager 350-40732]

[b] REFER to Protective Action Recommendation Logic Diagram (Page 12) AND IF change in PAR required, THEN 0 COMPLETE GE Follow-up Form (Page 14) AND REPORT to ODS for State notification at:

IRingdowoTe Ior 15-751-17o01 or 1-751-249I or 19-785-17001 AND FAX ODS GE Follow-up Form (Page 14) iFA I5-751-86i20

[12] IF there are personnel injuries, THEN IMPLEMENT EPIP-10, "Medical Emergency Response." El

[13] IF there is a security threat, THEN NOTIFY Security Shift Supervisor to implement PHYSI-32, "Security Instructions For Members Of The Security Force" El 6144 or 58 FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 7 of 14 Date 3.1 ACTIVATION OF THE REP BY SM (Continued)

[14] NOTIFY Plant Management in accordance with SPP-3.5 AND PROVIDE GE Notification Information. D NOTE 1 NRC notification should be made as soon as practicable, but within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of "GENERAL EMERGENCY" declaration. Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center.

NOTE 2 Do not dial "1" prior to the number when using ENS phones.

[15] NOTIFY NRC of plan activation via ENS in accordance with SPP-3.5.

(301) 816-5100 (Main) (301) 951-0550 (Backup 9-1-(301) 816-5151 (Fax)

Initial Time

[16] MONITOR plant conditions AND EVALUATE using EPIP-1 until TSC is staffed, AND

[a] IF additional conditions satisfy criteria of other GENERAL EMERGENCYs OR

[b] IF changes to Protective Action Recommendations OR

[c] IF conditions warrant a need for follow-up information, THEN COMPLETE GE Follow-up Form (Page 14), AND REPORT to ODS for State notification at:

IRingdownL or 15-751-17ol0 or 15-751-2495 or E9-785-17600 AND FAX ODS GE Follow-up Form (Page 14) i5-751-8620 FAXI END OF SECTION FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 8 of 14 Date 3.2 ACTIVATION OF THE REP BY TSC Upon classifying events as a GENERAL EMERGENCY in accordance with EPIP-1, "Emergency Plan Classification Matrix," the SED shall:

[1] IF personnel accountability has not been previously initiated, THEN

[a] DIRECT TSC Security Manager or Security Shift Supervisor to implement EPIP-8, "Personnel Accountability and Evacuation." El 6144 6or

[b] DIRECT SM to ACTIVATE emergency sirens for personnel assembly.

Initial Time

[2] IF GENERAL EMERGENCY Classification has been declared by SM, THEN GO TO Step [6] OR appropriate Step based on SM turnover. El NOTE CECC Director should be notified within 5 minutes after declaration of the event

[3] COMPLETE GE Notification Form (Page 13). El

[4] NOTIFY CECC Director.

[a] CALL CECC Director.

or 1 5-751 -1 4 or 5-751-16181 I RingdownLe Initial Time

[b] READ completed Form (Page 13) to CECC Director.

[c] FAX CECC GE Notification Form (Page 13). El 15-751-16827Fx FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 9 of 14 Date 3.2 ACTIVATION OF THE REP BY TSC (Continued)

[5] IF CECC Director CANNOT be contacted within 10 minutes of the declaration, THEN

[a] NOTIFY Tennessee Emergency Management Agency (TEMA).

9-1-800-262-3300 1 or F9--615-741-0001 I or F888-616-8091 (satellite)

Initial Time

[1] READ completed Form (Page 13) to TEMA. Dl

[2] FAX TEMA GE Notification Form (Page 13). El 1 9-1-615-242-9635 FAX I

[b] NOTIFY Hamilton County Emergency Management Agency (EMA) AND 19-209-69o o 1 9-622-77771 or 19-622-0022 1 Initial Time READ completed Form (Page 13) to Hamilton County EMA. El

[c] NOTIFY Bradley County EMA AND 9-476-06 or 9-476-75¶11 Initial Time READ completed Form (Page 13) to Bradley County EMA. El

[6] IF CECC EPIP-9 "Emergency Radiological Monitoring Procedures."

has not been previously initiated, THEN DIRECT TSC RADCON Manager to implement CECC EPIP-9 El FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 10 of 14 Date 3.2 ACTIVATION OF THE REP BY TSC (Continued)

NOTE The Dose Assessment function is transferred to the CECC once they are staffed.

[7] MONITOR radiation monitors.

WHEN indication of an unplanned radiological release, THEN PERFORM Dose Assessment.

[a] DIRECT TSC Chemistry Manager or Chemistry Shift Supervisor to perform a dose assessment using EPIP-14, "Radiological Control Response." El 7285 Lab or [ 6348 Lab or Pager 350-40732

[b] REFER to Protective Action Recommendation Logic Diagram (Page 12) AND IF change in PAR required, THEN Rl COMPLETE GE Follow-up Form (Page 14) AND REPORT to CECC Director for State notification at:

Ringdo ine or 15-751-16147 or 15-751-16801 AND FAX CECC GE Follow-up Form (Page 14) 5-751-1682

[8] IF there are personnel injuries, THEN IMPLEMENT EPIP-10, "Medical Emergency Response." El

[9] IF there is a security threat, THEN DIRECT TSC Security Manager or Security Shift Supervisor to implement El PHYSI-32,"Security Instructions For Members Of The Security Force".

or 1 6i FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 11 of 14 Date 3.2 ACTIVATION OF THE REP BY TSC (Continued)

NOTE I NRC notification should be made as soon as practicable, but within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> of "GENERAL EMERGENCY" declaration. Whenever NRC requests, a qualified person must provide a continuous update to NRC Operations Center.

NOTE 2 Do not dial "1" prior to the number when using ENS phones.

[10] ENSURE NRC has been notified of plan activation via ENS in accordance with SPP-3.5.

(301) 816-5100 (Main) (301) 951-0550 (Backup) 1 9-1-(301) 816-5151 (Fax)I Initial Time NOTE Protective Action Recommendation are the responsibility of the CECC Director after assuming that responsibility from the SED.

[11] MONITOR plant conditions AND EVALUATE using EPIP-1, AND

[a] IF additional conditions satisfy criteria of other GENERAL EMERGENCYs OR

[b] IF change to Protective Action Recommendations OR

[c] IF conditions warrant a need for follow-up information, THEN COMPLETE GE Follow-up Form (page 14), AND REPORT to CECC Director for State notification at:

I Ringdown Linel or 15-751-1614 or 5-751-1680J AND FAX CECC GE Follow-up Form (Page 14) 15-751-1682FA OR

[d] IF situation no longer exists, THEN TERMINATE emergency per EPIP-16, "Termination and Recovery," AND El COMPLETE GE Follow-up Form (Page 14) including ri 11 Time and Date Event Terminated and FAX to CECC. 5F751-1682 FAXI END OF SECTION I FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 12 of 14 PROTECTIVE ACTION RECOMMENDATION LOGIC DIAGRAM SGENERAL EMERGENCY DECLARED SEQUOYAH NUCLEAR PLANT C At NOTES ,.,-or beyond 5 MILES Projected or aYlf conditions are not known Measured Dose Then Answer NO. S> the Table 1 /...... R A*l*il RE.CUMMINUA I IOIN 1 ICONTINUE ASSESSMENT. I VP%..'LJI Miles Radius Modify protective actions and 10 Mile*s downwind NO based on available plant and and SHELTEFSremainder o1 field monitoring information. 10 Mil

  • EPZ Locate and evacuate additional localized hotspots Indiction of SvereCor 0

TABLE 1 Daag> hevaue RADIOACTIVITY RELEASE DOSE TYPE LIMIT 3.9E-6 microCI/cc of Iodine 131 Measured I/*sthere Loss of Physica*

1 REM/hr External Dose I REM TEDE Projected N ( RECOMME,NDATION 2 5 REM Thyroid CDE YES EVACUATE 2 Miles Radius and 5 Mile s downwind

- . orbeyond nd TABLE 2 2MILESProjected or SHELTER re mainder of 10 Measured Dose Mile EPZ SEVERE CORE DAMAGE INDICATIONS > al h

1. Containment Radiation NO

© Monitor Reading on RM-90-271 or 272 is DATION 3

> 28 REM/hr. EVACUATE 2 Miles Radiu:

SRECOMMENI or or beyond the anc I

2. Containment Radiation SITE BOUNDARY SHELTER rE.mainder of Monitor Reading on Projected or Measured 10 Mile EPZ RM-90-273or 274 is

> 29 REM/hr. Li or

3. Reactor coolant Activity of NO%

> 300 microCI/gm Dose Equivalent 1-131. RECOMMENDATION 4 or SHELTER 2 Miles Radius

4. Inadequate core cooling as and indicated by "red" or SHELTER 5 Miles "orange" path from core Downwind cooling status tree.

G FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 13 of 14 GENERAL EMERGENCY NOTIFICATION FORM

1. 0 THIS IS A REAL EMERGENCY EVENT. THIS IS A REAL EMERGENCY EVENT.

OR El THIS IS A DRILL. THIS IS A DRILL.

2. This is at Sequoyah Nuclear Plant.

(Your Name)

3. There has been a GENERAL EMERGENCY declared at Sequoyah Nuclear Plant.

Affecting El Unit 1 OR El Unit 2 OR El Both Units 1 & 2

4. EAL Designator:
5. Brief Description of Event
6. Plant conditions are: El Stable E- Deteriorating
7. Radiological Conditions are:

El No Abnormal Release Off-site El Airborne Release Off-site El Liquid Release Off-site El Release Information Not Known

8. Event Declared: Time: Date:
9. Event Terminated: Time: Date:
10. The Meteorological Conditions Are: (Use MET Tower elevation 46, alternate elevation 90.)

Wind Speed mph Wind Direction From

11. Protective Action Recommendation: (For Determination See PAR Logic Diagram Page 12)

El RECOMMENDATION 1 [a] EVACUATE 2 mile radius and 10 miles downwind AND

[b] SHELTER remainder 10 mile EPZ El RECOMMENDATION 2 [a] EVACUATE 2 mile radius and 5 miles downwind AND

[b] SHELTER remainder 10 mile EPZ El RECOMMENDATION 3 [a] EVACUATE to 2 mile radius AND

[b] SHELTER remainder 10 mile EPZ

[El RECOMMENDATION 4 [a] SHELTER to 2 mile radius AND

[b] SHELTER 5 miles downwind

12. "Please Repeat the Information You Have Received to Ensure Accuracy." E FAX TO THE ODS AT 751-8620 AFTER COMPLETING THE NOTIFICATION FORWARD COMPLETED PROCEDURE TO EMERGENCY PREPAREDNESS, OPS 41-SQN

EPIP-5 SQN GENERAL EMERGENCY Rev. 25 Page 14 of 14 GENERAL EMERGENCY FOLLOW-UP FORM

1. 13 THIS IS A REAL EMERGENCY EVENT. THIS IS A REAL EMERGENCY EVENT.

OR 0l THIS IS A DRILL. THIS IS A DRILL.

2. This is at Sequoyah Nuclear Plant.

(Your Name)

3. This is Follow-up Information Regarding the GENERAL EMERGENCY declared at Sequoyah Nuclear Plant Affecting D3 Unit 1 OR 13 Unit 2 OR El Both Units 1 & 2
4. Reactor Unit I R3 Shutdown E3 At Power Unit 2 13 Shutdown 13 At Power
5. Plant conditions are: E3 Stable El Deteriorating
6. Additional EAL Designator (s):
7. The Following Significant Changes in Plant Conditions Have Occurred:
8. Evacuation of nonessential site personnel is on going:

E3 YES 13 NO OR E3 COMPLETED

9. The Following Significant Changes in Radiological Conditions Have Occurred:
10. The Following Changes To Protective Action Recommendations Have Occurred:
11. The Meteorological Conditions Are: (Use MET Tower elevation 46, alternate elevation 90.)

Wind Speed mph Wind Direction From

12. Event Terminated:Time: Date:
13. "Please Repeat the Information You Have Received to Ensure Accuracy." 13
14. Name Date Time

"(Preparer'sName)

15. FAX TO THE ODS AT 751-8620 OR CECC AT 751-1682 AFTER COMPLETING THE NOTIFICATION. 13

..... .. S..

..... ... = .i .. *=,sl 'l'*l 'l II ~ b IJ A u i'il*J b ,* i iV s b* ,liA P 1'UKWAKU LU1VWLIILU rKULLDUILL IU L1iIL1iAyL1.. I rIrtIxr-"1t,, ii

TENNESSEE VALLEY AUTHORITY SEQUOYAH NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE EPIP-7 ACTIVATION AND OPERATION OF THE OPERATIONS SUPPORT CENTER (OSC)

Revision 18 QUALITY RELATED PREPARED/PROOFREAD BY: W. P. Brooks RESPONSIBLE ORGANIZATION: Emergency Preparedness APPROVED BY: John Casey EFFECTIVE DATE: 9-1-2000 LEVEL OF USE: REFERENCE REVISION DESCRIPTION: Intent Change: Revision changed the reporting requirement for the OSC; modified responsibilities of the MSS; added support from DCRM and Material Coordinator; updated terminology from REX to HIS-20; changed Operations Advisor reporting from TSC Ops Manager to TSC Operations Communicator; revised position titles; and revised checklist items to several checklists.

SNI SQN ACTIVATION AND OPERATION OF THE OPERATIONS SUPPORT CENTER EPIP-7 Rev. 18 1 1 Page 2 of 36 TABLE OF CONTENTS Section Title Page T able of C ontents ........................................................................................ 2 1.0 P UR P O SE .................................................................................................. 3 2.0 R E FE R E NC E S ............................................................................................. 3 3.0 INSTRUCTIONS ....................................................................................... 3 3.1 An Alert or Higher Classification ................................................................. 3 3.2 A ctivation of O SC ....................................................................................... 3 3.2.1 Shift Manager Actions ................................................................................. 3 3 .2 .2 C all List .................................................................................................... ..4 3.2 .3 R esponse .................................................................................................. 4 3.2.4 Maintenance Shift Supervisor (MSS) ......................................................... 5 3.2.5 O S C O peration ............................................................................................ 5 3.2.6 OSC Manager ........................................................................................... 6 3.2.7 Assistant OSC Manager ............................................................................. 7 3.2.8 OSC RADCON Supervisor ......................................................................... 7 3.2.9 OSC RADCON Briefer ............................................................................... 7 3.2.10 OSC Operations Advisor ............................................................................. 7 3.2.11 Personnel Pool Manager ............................................................................. 7 3.2.12 Fire Operations Advisor ............................................................................... 8 3.2.13 Chemistry Shift Supervisor ......................................................................... 8 3.2.14 OSC Log Keeper ....................................................................................... 8 3 .2 .15 OS C C lerk .................................................................................................. 8 3.2.16 OSC Site Security Advisor ........................................................................... 8 3.2 .17 OS C Briefers .............................................................................................. 8 3.2.18 OSC Industrial Safety Advisor ..................................................................... 8 3.2.19 DCRM Coordinator ...................................................................................... 9 3.2.20 OSC Nuclear Stores Coordinator ................................................................ 9 3.3 Deactivation ............................................................................................... 9 4.0 RE C O R D S .................................................................................................. 9 4 .1 QA R ecords ............................................................................................... 9 4.2 Non-Q A R ecords ........................................................................................ 9 APPENDICES Appendix A, OSC Manager Checklist ......................................................... 10 Appendix B, Emergency Conditions Data Sheet ......................................... 12 Appendix C, Assistant OSC Manager Checklist ........................................... 14 Appendix D, OSC Team Tracking/Briefing/Debriefing Forms ..................... 16 Appendix E, OSC RADCON Supervisor Checklist ...................................... 18 Appendix F, OSC RADCON Briefer Checklist ............................................. 20 Appendix G, OSC Operations Advisor Checklist ........................................ 21 Appendix H, Fire Operations Advisor Checklist .......................................... 22 Appendix I, OSC Log Keeper Checklist ..................................................... 23 Appendix J, OSC Clerical Staff Checklist ................................................... 24 Appendix K, OSC Site Security Advisor ..................................................... 25 Appendix L, OSC Briefer Checklist .............................................................. 26 Appendix M, OSC Industrial Safety Checklist ............................................ 28 Appendix N, OSC Personnel Pool Manager Checklist ................................ 29 Appendix 0, DCRM Coordinator Checklist ................................................. 30 Appendix P, OSC Material Coordinator Checklist ...................................... 31 Appendix Q, Operations Support Center Telephone Listing ....................... 32 Appendix R, Personnel Pool Mgr. Log ....................................................... 33 Appendix S, ERO Roster and Call-In Form ................................................. 34 SOURCE NOTES ....................................................................................... 36

ACTIVATION AND OPERATION OF THE EPIP SQN OPERATIONS SUPPORT CENTER Rev.18 Page 3 of 36 1.0 PURPOSE The purpose of this procedure is to describe the activation of the Operations Support Center (OSC), describe the OSC organization, and provide for OSC operation once it has been staffed. The OSC is activated during an "Alert,"

"Site Area Emergency," or "General Emergency."

2.0 REFERENCES

Developmental Documents A. EPIP-6, "Activation and Operation of the Technical Support Center" B. EPIP-8, "Personnel Accountability and Evacuation" C. EPIP-14, "Radiological Control Response" D. EPIP-16, "Termination and Recovery" 3.0 INSTRUCTIONS 3.1 An Alert or higher Emergency Classification At an Alert or higher Emergency Classification, the OSC Manager will report directly to the OSC and shall be responsible for implementing this procedure and coordinating OSC personnel and activities.

3.2 Activation of OSC 3.2.1 Shift Manager (SM) Actions The SM will activate the OSC by announcing the emergency condition by one or more of the following methods:

A. Plant Public Address (PA) announcement.

B. The Shift Manager or operations clerk will normally activate the Emergency Paging System (EPS) or contact the persons designated on the REP Duty Roster and/or Call List. If the EPS cannot be activated from the site, the SM will contact the Operations Duty Specialist (ODS) and have the EPS activated from the CECC.

C. The SM may activate the onsite emergency sirens at an "Alert" and shall activate the sirens at a "Site Area Emergency" or "General Emergency".

I ACTIVATION AND OPERATION OF THE EPIP-7 Rev.o18 SQN OPERATIONS SUPPORT CENTER Page 4 of 36 N ON 3.2.2 Call List The Emergency Preparedness Manager (EPM) shall maintain a REP Duty Roster and Call List book listing key OSC personnel by name, plant and home telephone numbers. The REP Call List and Duty Roster book will be updated at least quarterly by the EPM or designee with input by the appropriate section/group supervisors. This book will be provided to the SM and will also be maintained in the TSC and OSC.

3.2.3 Response The following personnel should report to the OSC or the assigned OSC support location upon announcement of an "ALERT" or higher emergency classification, or at the direction of the SED:

A. OSC Manager B. Assistant OSC Manager C. Maintenance Shift Supervisor D. OSC RADCON Supervisor E. Fire Operations Advisor F. OSC Operations Advisor G. Two Instrument Maintenance Briefers H. Two Mechanical Maintenance Briefers I. Two Electrical Maintenance Briefers J. RADCON Briefer K. Chemistry Shift Supervisor L. OSC Personnel Pool Manager M. Two Duty Damage Control Teams(0)

N. RADCON Lab Supervisor

0. Other plant staff the OSC Manager determines to be necessary to support OSC functions will be called:
1. OSC Clerks
2. OSC Log Keeper
3. HIS-20 Operator
4. Maintenance Personnel needed for support
5. Operations Personnel needed for support
6. Transmission and Customer Service
7. Technical Support Personnel needed for support
8. DCRM support
9. Materials support
10. Industrial Safety support
11. Security Advisor (1) A team will dress-out and standby for assignment.

ACTIVATION AND OPERATION OF THE IEPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 36 Page 5 of 3.2.4 Maintenance Shift Supervisor (MSS)

The Maintenance Shift Supervisor (MSS) shall ensure that the OSC and Tool Room are unlocked and open for access when required. The MSS maintains responsibility as single point maintenance contact for the Shift Manager until the OSC Manager is in place. The MSS initiates OSC setup and may sign designated actions on the Assistant OSC Manager's Checklist.

The MSS may assist in the activation of the Emergency Response Organization to ensure adequate personnel are available. The MSS will provide a briefing to the OSC Manager when he arrives and then becomes the second Assistant OSC Manager.

3.2.5 OSC Operation The OSC shall operate to ensure the following actions are taken:

A. All personnel or teams previously tasked by the Control Room or Site Emergency Director prior to OSC staffing and activation shall be located and assigned a Team Tracking Letter designation for tracking and debriefing purposes.

B. All teams shall be briefed and/or coordinated with the OSC prior to dispatch and debriefed by the OSC upon task completion. The exceptions are:

"* AUO teams responding to procedure driven missions or are otherwise under the direction of the SM. These teams shall be tracked on the OSC Ops tracking board via communication between the Control Room Communicator and the OSC Operations Advisor.

"" The Fire Brigade or Medical Emergency Response Team may be briefed in route by radio when response time is critical. These teams will be tracked by the OSC.

"* If an Emergency Response Team is responding or near the task area prior to OSC staffing the team may be briefed by radio or telephone and shall be tracked by the OSC.

"* RADCON Survey Teams and Chemistry Teams may be dispatched directly from their respective labs provided they are coordinated through the OSC RADCON Supervisor and tracked on the RADCON/CHEM board C. Each potential damage control and repair team member shall have qualifications verified and dosimetry issued prior to assignment to a response team.

D. RADCON and Operations should be members of each response team.

E. Each team should have a radio for communications with the OSC. The Operations or RADCON member of each team should be the radio talker. Muted radios are available for use in radio-sensitive areas of the plant.

F. RADCON shall maintain sufficient respiratory protection equipment available for issue in a manner that will not delay teams response.

AND OPERATION OF THE I EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 Page 6 of 36 3.2.5 OSC Operation (Continued)

G. Teams should respond with damage control tool kits to the assigned task.

H. If a person/team is unable to complete a mission or is reassigned a task after briefing, the OSC shall be immediately notified by the team leader.

1. At least one Emergency Response Team is on standby at all times.

3.2.6 OSC Manager The OSC Manager is responsible for directing repairs and corrective actions; performing damage assessment; coordinating repair activities with the TSC; coordinating maintenance teams and ensuring proper briefings and accompaniment by RADCON; activating the Fire Brigade, Search and Rescue, and Medical Emergency Response Teams as necessary; relocation of the OSC in accordance with 3.2.6.A; deactivating the OSC. Appendix A, OSC Manager Checklist, shall be used to ensure required actions are completed.

A. Relocate OSC personnel and equipment to an alternate OSC location when conditions require:

1. Direct OSC RADCON Supervisor to make habitability survey for the OSC if a release has occurred. Surveys are to include direct radiation readings, area swipes, and air activity monitoring.
2. Inform the SED if conditions exceed habitability criteria.
3. Relocate the OSC (upon direction from the SED) to the backup OSC in the O&PS building if it meets habitability requirements.
4. If the backup OSC does not meet habitability criteria, than an alternate location must be selected based on the following criteria:
a. Location has adequate access to the plant (preferably is within the Protected Area), has a current radiological survey, is upwind from plant, and has adequate ventilation control.
b. Location has adequate communications capabilities (including three telephone circuits).
c. Physical size: space for at least 25 persons.
d. Provides access to appropriate reference materials, tools, safety equipment, etc.

3.2.7 Assistant OSC Manager The Assistant OSC Manager maintains continuous communication with the Maintenance Manager in the TSC, ensuring that OSC tasks are entered on the team tracking board/system; initiates an OSC Team Briefing/Debriefing Form, (Appendix D) for each task; assigns tasks to briefing teams; coordinates and directs damage control and repair activities as directed by the OSC Manager; ensures RADCON support for each team; ensures all teams (except as indicated in 3.2.5.B) are briefed before dispatch in accordance with Appendix D; ensures all teams are debriefed upon return to the OSC in accordance with Appendix D. When available, a qualified individual may assume communications and/or boardwriting responsibilities as delegated by the Assistant OSC Manager. Appendix C, Assistant OSC Manager Checklist, shall be used to ensure required actions are completed.

3.2.8 OSC RADCON Supervisor The OSC RADCON Supervisor provides and coordinates RADCON resources; assigns a HIS-20 Operator and calls in additional support as needed; directs the RADCON Lab through the Lab Supervisor; informs the TSC RADCON Manager, OSC Manager and OSC RADCON briefer of current radiological conditions; enters data on the Radcon/Chem tracking board; provides RADCON support for emergency response teams as warranted.

Appendix E, OSC RADCON Supervisor Checklist, shall be used to ensure required actions are completed.

3.2.9 OSC RADCON Briefer The OSC RADCON briefer remains informed of the site radiological conditions; provides technical assistance for radiological concerns; assist in technical briefings of OSC teams; ensures each team has a RADCON member present during briefing or may be dispatched with the team; completes applicable portions of Appendix D. Appendix F, OSC RADCON Briefer Checklist, shall be used to ensure required actions are completed.

3.2.10 OSC Operations Advisor The OSC Operations Advisor provides operational advice, plant status, and important system parameters to support the operation; provides Operations personnel as part of OSC response teams as warranted; maintains the Operations tracking board in the OSC. Provide Operations personnel, advice, and plant status to support the entire OSC including briefing emergency response teams as needed. Keeps the TSC Operations Communicator and Control Room Communicator informed of OSC team activities. May provide briefing/debriefing to AUOs as requested by the Control Room Crew and/or SED. Appendix G, OSC Operations Advisor Checklist, shall be used to ensure required actions are completed.

3.2.11 Personnel Pool Manager The OSC Personnel Pool Manager provides and coordinates a pool of qualified maintenance personnel to staff damage control and repair teams.

He also tracks individual team members and assesses their future availability for other assignments. Appendix N, Personnel Pool Manager Checklist, shall be used to ensure required actions are complete. The Personnel Pool Manager Log (Appendix R) should be used to manage information regarding individual qualifications and OSC assignments.

ACTIVATION AND OPERATION OF THE EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 1 1 Page 8 of 36 3.2.12 Fire Operations Advisor The Fire Operations Advisor initiates fire response, medical emergency response, hazardous material containment; provides personnel to support Nuclear Security in searches of hazardous areas. Provides evaluations of the plant environment and recommendations to OSC management on safety aspects of the response team tasks. Contacts the site and/or corporate Safety Specialist as necessary. Maintain status of Fire Ops personnel.

Appendix H, Fire Operations Advisor Checklist, shall be used to ensure required actions are completed.

3.2.13 Chemistry Shift Supervisor The Chemistry Shift Supervisor in the CHEM lab provides first-line direction of Chemistry support personnel; calls in additional support as required; briefs Chemistry personnel on emergency events and status; initiates onsite/off-site dose assessment, per EPIP-14, as directed by the TSC or the Ops. SM; provides Chemistry support to the OSC as needed.

3.2.14 OSC Log Keeper The OSC Log Keeper ensures status boards are continuously updated to reflect current plant conditions and collects/maintain all original copies of generated documents. Appendix I, OSC Log Keeper, shall be used to ensure required actions are completed.

3.2.15 OSC Clerk The OSC Clerk provides logistics support to the OSC. Appendix J, OSC Clerical Staff, shall be used to ensure required actions are completed.

3.2.16 OSC Site Security Advisor The OSC Site Security Advisor coordinates Nuclear Security activities from the OSC when requested by the TSC Security Mgr or OSC Mgr; supports response to fire, medical emergencies, or other security responses; conducts search and rescue operations. Appendix K, OSC Nuclear Security Advisor, shall be used to ensure required actions are completed.

3.2.17 OSC Briefer The OSC Briefer provide and coordinate resources to support the OSC Manager; provide damage and repair assessments; remain informed of the site conditions; assist in technical briefings of OSC emergency response teams; and complete applicable portions of Appendix D. Appendix L, OSC Briefer Checklist, shall be used to ensure required actions are completed.

3.2.18 OSC Industrial Safety Advisor Industrial Safety issues are normally handled by the team briefer and/or assistance from Fire Ops when needed. If necessary, Fire Ops will contact site/corp Safety Specialist. When requested, Appendix M, Industrial Safety Advisor Checklist shall be used to ensure required actions are completed.

I ACTIVATION AND OPERATION OF THE EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.o18 1 1 Page 9 of 36 3.2.19 DCRM Coordinator The DCRM Coordinator provides support to OSC personnel by providing drawings, documents, vendor manuals and provides other support as requested. When requested, Appendix 0, DCRM Coordinator Checklist, shall be used to ensure required actions are completed.

3.2.20 OSC Materials Coordinator The Materials Coordinator provides support to the OSC by determining materials availability, coordinating between Power Stores and the OSC and by expediting materials needed. When requested, Appendix P, OSC Materials Coordinator Checklist shall be used to ensure required actions are completed 3.3 Deactivation The OSC will be deactivated when directed by the SED. Appendix A, OSC Manager Checklist, may be used to ensure required actions are completed.

4.0 RECORDS 4.1 QA Records The following records generated during real emergency events are considered QA Records. These shall be forwarded to the EP Manager who shall submit QA Records and any other records deemed necessary to corporate Emergency Preparedness for maintenance.

A. Appendix B, Emergency Conditions Data Sheets B. Appendix D, OSC Team Briefing/Debriefing Forms C. Appendices for OSC Position Checklists D. OSC Log Sheets 4.2 Non-QA Records The appendices and checklists to this procedure necessary to demonstrate key actions during NRC evaluated exercises, drills, or used to establish/support NRC Performance Indicators will be retained by the SQN EP Manager for at least 2 years.

ACTIVATION AND OPERATION OF THE IEPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 IPagle 10 of 36 Date:

APPENDIX A Page 1 of 2 OSC MANAGER CHECKLIST INITIAL ACTIVATION OF THE OPERATIONS SUPPORT CENTER Time/

Initials

1. Swipe Accountability Reader.
2. Ensure OSC set-up using materials in OSC Storage closet.
3. Establish a log of activities and communications.
4. Ensure OSC Briefing Area set-up using materials in OSC storage closet.
5. Obtain briefing from the MSS.
6. Establish communications with the TSC and obtain an update of the emergency conditions. Appendix B should be used as a guideline.
7. Determine location and function of persons/teams currently and previously tasked by the TSC or Control Room and ensure assignment of Team Tracking Letter designation.

_8. Ensure Activation of OSC.

a. Ensure minimum staffing in OSC. (See note below)
b. Ensure OSC set-up complete.
c. Ensure OSC habitability OR relocate OSC in accordance with 3.2.6.A.
d. Ensure OSC support personnel are notified of activation, if needed.
9. Brief OSC Personnel on Plant Conditions, unless SED has provided briefing.
10. Announce to the OSC and notify the SED the time that OSC is operational and activated.
11. Establish necessary emergency teams.

NOTE: Minimum staffing requirements are one representative from Mechanical Maintenance, Electrical Maintenance and Instrument Maintenance.

Continued Next Page

AICTIVATION AND OPERATION OF THE EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 I Page 11 of 36 Date:

APPENDIX A Page 2 of 2 OSC MANAGER CHECKLIST OPERATIONAL RESPONSIBILITIES

"* Demonstrate command and control of the OSC throughout the emergency.

"* Direct Asst. OSC Manager to form teams for accident assessment and repair and Announce the intent to form OSC teams.

"* Approve and Announce the dispatching of teams from the OSC.

"* Provide supplemental staffing for the OSC if needed.

"* Periodically direct key OSC positions to provide status summary to OSC staff or perform briefing yourself.

"* Update the SED and TSC Maintenance Manager as needed.

"* Ensure that team activities are prioritized and synchronized with the TSC.

"* Announce results of OSC teams following debriefing.

"* If event duration expected to exceed 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, then establish relief rotations using Appendix S.

"* Request habitability survey by RADCON if a release has occurred.

"* Relocate the OSC as habitability conditions dictate.

"* Maintain a log of communications and activities.

"* Informs TSC of as-found plant conditions and status of emergency conditions.

  • Ensure the Emergency Response Teams Tracking Boards/System, Radiological Status Boards and other visual displays are kept current.

DEACTIVATION RESPONSIBILITIES

  • Ensure all assigned tasks and assignments are completed.
  • Ensure all emergency response teams have been debriefed.
  • Ensure all emergency equipment and supplies have been returned to their specified storage locations.

IAI AND OPERATION OF THE OPERATIONS SUPPORT CENTER EPIP-7 Rev.18 SQN Page 12 of 36 Date:

APPENDIX B Page 1 of 2 OSC MANAGER BRIEFING OUTLINE Emergency Classification: (check one)

[1 UNUSUAL EVENT [-] ALERT [ SITE AREA EMERGENCY [-] GENERAL EMERGENCY Affected Unit: [-1 UNIT I [-- UNIT 2 [I BOTH UNITS 1 & 2 Event

Description:

UNIT STATUS: [- UNIT I

[1 UNIT 2 Time Emergency Classified:

Primary Plant Condition: UNIT 1 Mode: 1II, "-2, 1-113, 1-14, [-15, or [-16 UNIT 2 Mode: [11, 12, [-13, [:14, [1]5, or [-16 Electrical Lineup:

DESCRIPTION OF ANY ABNORMAL LINEUP Diesel Generators: DG I Operating [-1 Yes / [1 No DG 2 Operating [E Yes / R[ No Offsite Power Avail able: 1 Yes/ RI No Major Mechanical P roblems:

Major Electrical Problems:

Continued Next Page

SQ I ACTIVATION AND OPERATION OF THE EPIP-7 Rev. 18 SQN OPERATIONS SUPPORT CENTER 1Pagle 13 of 36 Date:

APPENDIX B Page 2 of 2 OSC MANAGER BRIEFING OUTLINE Major Instrument and Control Problems:

Environmental Problems High Rad Levels:

Toxic Gas:

High Press. Steam Releases:

Other:

Recorded by:

Time: _ _ _ _ _

Date:

I ACTIVATION AND OPERATION OF THE I EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 Page 14 of 36 Date:

APPENDIX C Page 1 of 2 ASSISTANT OSC MANAGER CHECKLIST INITIAL ACTIVATION OF THE OSC Time/

Initials

1. Swipe Accountability Reader- Assistant OSC Manager.

Swipe Accountability Reader - Maintenance Shift Supervisor.

2. Obtain keys at Work Coordination Center and open cafeteria (if locked), the OSC, and OSC storage room. (May be signed off by MSS)
3. Ensure the minimum maintenance personnelare staffed or have been called in as necessary, (May be signed off by MSS)

J[Mechanical Craft (Electrical Craft Instrumentation Craft ONSITE Hi 1 on shift Li 1 on shift CALL-IN Hi 1 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Li 1 onsite within 30 minutes Li 1 onsite within 30 minutes CALL-IN __ 1 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Li 1 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> TOTAL TOTAL: 2 Available onsite within 30 TOTAL 2 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> minutes and 2 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> TOTAL 3 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

4. Open the Tool Room if it is not staffed. (May be signed off by MSS)
5. Establish a log of activities and communications.
6. Establish contact with Maintenance Manager in the TSC (Bridge x104 or 6478).
7. Obtain initial briefing and status of Operations and Maintenance tasks related to the emergencies that are underway from MSS, OSC Manager, or SM.
8. Ensure all emergency response teams previously tasked are assigned team tracking letter designation and entered on the Emergency Response Team Tracking Board/System.
9. Assign a team briefer to any teams previously dispatched.
10. Ensure that two emergency response teams are pre-staged in the OSC staging area of the cafeteria.
11. Notify Power Stores (X 7155) and the Tool Room (X 7755) (if staffed), advise them to remain staffed during the emergency unless released by the Site Emergency Director.

Continued Next Page

I ACTIVATION AND OPERATION OF THE EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 Page 15 of 36 Date:

APPENDIX C Page 2 of 2 ASSISTANT OSC MANAGER INITIAL ACTIVATION OF THE OSC Continued

12. Verify the priorities of teams dispatched from the OSC, or being formed, with the TSC.
13. Review the OSC Team Tracking Board/System and reconcile any discrepancies with information obtained from briefing sources.

OPERATIONAL RESPONSIBILITIES

"* Assist the OSC Manager in providing direction and control to the OSC areas.

"* Open OSC, and OSC storage room.

"* Receive direction from SM/SED until OSC Manager arrives.

"* Oversee the operations of the OSC Teams and coordinate the supporting activities using Appendix D, "OSC Team Briefing/Debriefing Form".

"* Maintains continuous communication with Maintenance Manager in the TSC.

"* Receives TSC-assigned tasks, enters them on the Team Tracking Board/System, informs the OSC Manager, and assigns the task to a specific OSC Team Briefer.

"* Keeps the OSC Manager informed of important communications from the TSC.

"* Coordinate with OSC RADCON Supervisor and Operations Advisor as needed regarding OSC Team activities (determines if teams need RADCON and/or Operations support).

"* Maintain log of communications and activities.

DEACTIVATION RESPONSIBILITIES

"* Ensure all assigned tasks and assignments are completed.

"* Ensure all emergency response teams have been accounted for and debriefed.

"* Ensure all emergency equipment and supplies have been returned to their specified storage locations.

"* Ensure all log and team briefing forms are completed and signed.

I TIVATION AND OPERATION OF THE EPIP-7 Rev.18 SQN OPERATIONS SUPPORT CENTER Page 16 of 36 PPENDIX D Page 1 of 2 OSC TEAM BRIEFING/DEBRIEFING FORM TEAM ASST. MGR. TEAM TASK: LU Inspection U I rouble Snooung U e.pai

/

Init/Ti me TASK LOCATION: (Bldg, EL., Rm. Name, etc)

Date El ASSIGN Team next Letter designator (A, B, C etc.):

D3 ENTER on Team Tracking Board.

13 INFORM OSC Mgr. of task and make PA Announcement in OSC.

13 ASSIGN task to Lead Briefer Name:

Heads-up to Briefer: [] Ops E] R/C 13 Safety 13 Other RAD SUPV. RADCON REQUIREMENTS: RWP: LI Yes RWP # LjNo E] SCBA E] Respirator [] Dressout E] Other I Emergency Exposure Approved by SED: []Yes (REM Init/Time (Ref: EPIP-15) I-No KI ISSUE Approved by TSC Radcon Mgr.: []Yes LINo (Ref: EPIP-14)

BRIEFER Team Members Names Discipline (MM, EM, IM, etc.)

Team Leader Name:.

Init/Time AUO (Use Page 2 to conduct RADCON Tech briefing)

Briefing conducted by:

Communication Method: E] Phone# E] Pager#

[] Messenger [_] OSC Hotline (x6406)_

13 Radio Ch# Radio Sensitive Area (0-TI-OPS-000-063.0) I Yes 13 No EL Contact OSC Briefer Every Minutes OSC MGR. FINAL APPROVAL TO RELEASE TEAM

/ Team Necessary? E] Yes E] No Init/Time Radiological Condition Change Since Briefing? [] Yes [] No E] ANNOUNCE, on the OSC P/A, Intention to Dispatch the Team.

TEAM LEADER DEBRIEFING (Use Page 2 to conduct debriefing) or BRIEFER/ Debriefing conducted by:

Init/Time LI PROVIDE Summary to the OSC Manager.

M_UPDATE the OSC Team Tracking Board.

")SC MGR. F1 ANNOUNCE Team results over the OSC P/A system.

I 13 ENSURE TSC is informed of Team results.

Init/Tim e . .. ... . .

Continued Next Page

I I ACTIVATION AND OPERATION OF THE I EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 1 1 Pagje 17 of 36 Date:

APPENDIX D Page 2 of 2 EMERGENCY RESPONSE TEAM BRIEFING/DEBRIEFING CHECKLIST BRIEFING E-1 Description of problems -Team Priority I- Plant system status r- Plant radiological status F-E Route to/from work area

-- Hazards between OSC and work location r- Radiation Work Permit (RWP)

-- RADCON support

-- OPS support F-1 Procedures to be used El Tools needed (See tool pouch description in O-PI-REM-000-001 .Q, "Quarterly Tool Kit Inventory".)

El Equipment needed

-- Clearance required/Hold Order#

E-l Safety evaluation of job El Communication with OSC E-l Copy of Briefing Form (Appendix D) given to team with phone number(s).

E] Key(s) needed for task.

DEBRIEFING El Was assignment completed? El Observations from the Field El Equipment r- Hazards El Radiological conditions ['1 Unusual sounds, etc.

0ol

-I Other information El Team directed to Personnel Pc Manager NOTES: (Observations/Damage Assessment/Recommendations, etc.)

I ACTIVATION AND OPERATION OF THE EPIP-7 Rev.18 SQN OPERATIONS SUPPORT CENTER Page 18 of 36 Date:

APPENDIX E Page 1 of 2 OSC RADCON SUPERVISOR CHECKLIST INITIAL ACTIVATION OF THE OSC Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing Chart and obtain OSC badge.
3. Establish a log of activities and communications.
4. Ensure a) HIS-20 printout is brought from the RADCON Lab to the OSC; b) a HIS-20 Computer Operator is assigned to provide computer access or use the printout for RADCON qualification checks of Emergency Response Team members; c) any Emergency Response Team members already assigned tasks in the field have acceptable RAD and qualifications (Contact MSS to for names and assigned task of individuals);

d) the Personnel Pool Manager is notified when the HIS-20 operator is assigned and given the name of the HIS-20 operator.

5. Establish communications with the TSC RADCON Manager and the RADCON Lab Supervisor. (Bridge 103, mute telephone when not speaking. or X 6472/6463 TSC and X 6417 Lab).
6. Ensure adequate RADCON staffing available for OSC support. (Dosimetry support, boardwriters, RWP support, HIS-20 operators)
7. Locate all RADCON/CHEM personnel/teams currently and previously tasked and ensure that teams are identified on RADCON/CHEM Team Tracking Board for tracking and debriefing.
8. Control eating and drinking in the OSC until habitability has been established.
9. Ensure habitability surveys have been initiated for the of OSC, TSC, and Control Room.
10. Verify the minimum number of ANSI qualified RADCON personnel currently onsite and ensure that at least a total of eight (8) are available onsite within approximately 30 and at least 14 are available onsite within one hour of the SITE AREA EMERGENCY declaration [six (6) additional ANSI qualified RADCON personnel within the second 30 minutes]. The RADCON Lab Supervisor is counted as a 60 minute responder.

OPERATIONAL RESPONSIBILITIES

  • Brief Emergency response Teams.
  • Provide and coordinate RADCON resources as necessary.

Continued Next Page

SI ACTIVATION AND OPERATION OF THE I EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 IPage 19 of 36 Date:

APPENDIX E Page 2 of 2 OSC RADCON SUPERVISOR CHECKLIST OPERATIONAL RESPONSIBILITIES Continued

"* Direct RADCON personnel in the RADCON Lab.

"* Ensure all RADCON Teams are coordinated and tracked through the OSC.

"* Ensure all Chemistry Teams are tracked through the OSC.

"* Ensure Emergency Response Teams have adequate RADCON/dosimetry coverage present during briefings and field support.

"* Brief the OSC Manager regularly on radiological conditions status (especially when radiological conditions are changing rapidly).

"* Brief the TSC RADCON Manager on radiological conditions status.

"* Provide assistance to the OSC Manager as needed.

"* Periodically verify habitability of TSC, OSC, and Control Room (especially during changing radiological conditions and at each emergency classification upgrade).

"* Recheck tracking board after accountability, after major changes in plant conditions and at emergency classification upgrades.

"* Log on to the Intergated Computer System (ICS).

"* Periodically brief the RADCON and CHEM Lab personnel on plant status.

"* Administer KI to emergency response teams according to EPIP-14 and inform the OSC manager. (Forward EPIP-14 KI Issue Report to the TSC RADCON Manager.)

"* Ensure outlying teams/groups (i. e., line crews, warehouse) have dosimetry and are being protected throughout the emergency.

"* Ensure emergency responders' exposures are maintained As Low As Reasonably Achievable (ALARA).

DEACTIVATION RESPONSIBILITY

"* Ensure all teams are accounted for and properly debriefed.

"* Ensure all logs and team briefing forms are completed and signed.

ACTIVATION AND OPERATION OF THE EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 Page 20 of 36 Date:

APPENDIX F Page 1 of 1 OSC RADCON BRIEFER CHECKLIST INITIAL ACTIVATION OF THE OSC Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing Chart and obtain OSC badge.
3. Notify the OSC RADCON Supervisor of arrival.
4. Establish a log of activities and communications.
5. Locate all RADCON persons/teams currently and previously tasked and ensure assignment of Team Tracking Letter designator (AA, BB, etc.) for tracking and debriefing.
6. Establish communications on the RADCON Bridge (x103). Mute telephone when not speaking.

OPERATIONAL RESPONSIBILITIES

"* Provide radiological technical assistance to the Briefing Teams.

"* Provide radiological conditions for inclusion in the analysis of the job performed by the OSC Briefing Team.

"* Assist with portions of the OSC Team briefings and debriefings including a debriefing from the team RADCON member.

"* Ensure each OSC team has a RADCON member present during briefings and field support as needed. (Dispatch with team if necessary)

"* Complete applicable portions of Appendix D.

"* Inform the OSC RADCON Supervisor of any unexpected radiological conditions encountered.

"* Write on the RADCON status boards, RADCON Team Tracking Board and ensure wind direction arrow is kept current.

"* Post radiological status information in the OSC Teams Staging Area.

"* Ensure emergency responders exposures are maintained ALARA.

I CTIVATION AND OPERATION OF THE EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 IPaNe 21 of 36 O

Date:

APPENDIX G Page 1 of 1 OSC OPERATIONS ADVISOR CHECKLIST INITIAL ACTIVATION OF THE OSC Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing Chart and obtain OSC badge.
3. Establish a log of activities and communications.
4. Establish communications with the TSC Operations Communicator and the Control Room Communicator for updates and to obtain Operations support (Dial 101 on telephone).
5. Locate all Operations personnel/teams currently and previously tasked and ensure each is tracked on the Operations tracking board.
6. Activate the ICS terminal to the affected unit.
7. Announce on the portable radio OPS channel "OSC AUOs Report to the OSC" (Repeat).
8. Ensure AUOs Swipe Accountability Reader at cafeteria entrance.

OPERATIONAL RESPONSIBILITIES

" Provide Operations personnel, advice, and plant status to support the entire OSC including briefing emergency response teams as needed (additional Operations personnel including AUOs can be used to assist).

"* Operate the ICS and provide plant operations advice to support the OSC.

"* Provide personnel for any operations actions that may be required while in the field.

"* Provide Operations personnel for damage control and repair teams.

"* Call-in additional AUOs/Operations personnel from offshift to support OSC activities, if requested.

"* Keep the TSC Operations Communicator and the Control Room Communicator appraised of the OSC Team priorities, assignments and activities while in the field.

"* Provide assistance to the OSC Manager as needed.

"* Maintain the OSC Operations Tracking Board.

"* Direct AUOs to maintain a log, and listen to the Operations Bridge (X102) to maintain a current awareness on plant status as needed.

"* Ensure OSC AUOs maintain accountability by swiping reader at cafeteria entrance.

SQN I ACTIVATION OPERATIONSAND OPERATION SUPPORT OF THE CENTERI EPIP-7 Rev. 18 I Page 22 of 36 Date:

APPENDIX H Page 1 of 1 OSC FIRE OPERATIONS ADVISOR CHECKLIST INITIAL ACTIVATION OF THE OSC Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing Chart and obtain OSC badge.
3. Establish a log of activities and communications.
4. Establish communications with the Fire Operations Unit or the Fire Station.
5. Verify that Fire Operations, if not responding to a fire or medical emergency, has reported to the designated assembly area. (see Note below)
6. Ensure that Fire Operations if responding to a fire or medical emergency is assigned a Team Tracking Letter designator for tracking and debriefing and team has been entered on tracking board.
7. Ensure sufficient SCBA equipment and air bottles for response teams are available at established entry points.

Note: If Fire Operations is not involved in the emergency response, dispatch a Fire Operator to the MCR to operate panel 0-M-29. This operator will be tracked on a tracking board and will be recalled at the discretion of the Fire Brigade Leader.

OPERATIONAL RESPONSIBILITIES

"* Monitor plant status and initiate fire response.

"* Initiate medical emergency response as needed.

"* Initiate and provide first response for Hazardous Material Containment.

"* Support Nuclear Security in searches of hazardous areas.

"* Provide assistance to the OSC Manager as needed.

"* Periodically brief Fire Operations Unit personnel of plant status.

"* Brief the team in the field by telephone/radio (if necessary) in order to decrease response time.

"* Request the SM to sound the fire alarm when needed to form the fire brigade or MERT.

"* Provide evaluations of the plant environment, recommendations to OSC Management on safety aspects of response team task.

"* Contact or call in the site/corporate Safety Specialist as necessary (see REND Section G).

I ACTIVATION AND OPERATION OF THE OPERATIONS SUPPORT CENTER I EPIP-7 Rev.18 SQN 1Page 23 of 36 Date:

APPENDIX I Page 1 of 1 OSC LOG KEEPER CHECKLIST Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing Chart and obtain OSC badge.
3. Notify the OSC Manager of arrival.
4. Establish a log of OSC activities and communications.
5. Notify Boardwriter to report to the OSC if requested.
6. Notify OSC Clerks to report to the OSC if requested.
7. Notify other staff as determined by the OSC Manager if requested.

OPERATIONAL RESPONSIBILITIES

"* Ensure the OSC Status Boards are continuously updated to reflect current plant conditions.

"* Ensure a log is maintained of all important OSC activities.

"* Collect and maintain all original copies of generated documents.

"* Following OSC deactivation forward all records to the Emergency Preparedness Manager.

"* Retain completed original of OSC team briefing/debriefing form, Appendix D.

I CTIVATION AND OPERATION OF THE EPIP-7 Rev.18 SQN OPERATIONS SUPPORT CENTER Page 24 of 36 Date:

APPENDIX J Page 1 of 1 OSC CLERICAL STAFF CHECKLIST Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing Chart and obtain OSC badge.
3. Notify the OSC Manager of arrival.
4. Establish a log of activities and communications.
5. Ensure FAX is operable.

OPERATIONAL RESPONSIBILITIES

"* Uses call list to obtain staff for unfilled positions or replacement staff for shift turnovers as directed by the OSC Manager.

"* Assist in set-up and activation of the OSC.

"* Answer telephones.

"* Distribute forms.

"* Ensure OSC responders have signed the OSC Roster, Appendix S when requested.

"* Establish OSC Shift change (Use Appendix S page 2 of 2 and ask appropriate Fitness For Duty Questions).

"* Operates FAX machine.

"* FAX Emergency Response Teams summary to Main Control Room (FAX# 6208) and TSC (FAX# 6461) as necessary.

DEACTIVATION OF THE OSC

"* Transfers all log notes and other materials to the OSC Log Keeper.

"* Deactivate the OSC by returning all equipment, materials, and supplies to designated storage areas.

I I ACTIVATION AND OPERATION OF THE EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 IPage 25 of 36 SI Date:

APPENDIX K Page 1 of 1 OSC SITE SECURITY ADVISOR CHECKLIST Time/

Initials Swipe Accountability Reader.

2. Fill out the Organizational/Staffing Chart and obtain OSC badge.
3. Notify the OSC Manager of arrival.
4. Establish communications with Site Security Manager in the TSC (X 6469).
5. Establish a log of activities and communications.
6. Establish contact with the CAS.
7. Check status of emergency actions already in effect such as Accountability or Site Evacuation.

OPERATIONAL RESPONSIBILITIES

"* Coordinate activities of Site Security personnel in support of OSC activities.

"* Provide personnel to support Fire Operations in response to fire, medical emergency, or hazardous material containment.

"* Forms, briefs and dispatches search and rescue teams with Fire Operations support.

"* Provide assistance to the OSC (including briefing teams) as needed.

"* Ensure the OSC Manager/OSC Staff are aware of security hazards that could affect emergency response activities.

"* Ensure onsite Security personnel are apprised of radiological and plant conditions and associated hazards.

"* Ensure OSC Manager is aware of Security personnel locations and activities.

ACTIVATION AND OPERATION OF THE IEPIP-7 Rev.18 SQN OPERATIONS SUPPORT CENTER Page 26 of 36 Date:

APPENDIX L Page 1 of 2 OSC BRIEFER CHECKLIST INITIAL ACTIVATION OF THE OSC Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing Chart and obtain OSC badge.
3. Establish the "OSC Team Hotline" on position speaker phone by dialing X6406.
4. Establish a log of OSC activities and communications.
5. Establish contact with emergency team leaders.
6. Establish contact with Personnel Pool Manager.
7. If assigned a team that is already working in the field, establish contact with the team leader and ensure that they are fully briefed on their task and obtain status (report results to the OSC Manager).
8. Verify and/or ensure the minimum (for the briefer's discipline) maintenance personnel have been called in as necessary,

[Mechanical Craft Electrical Craft Instrumentation Craft ONSITE HI 1 on shift R] 1 on shift CALL-IN LI 1 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> [1]1 onsite within 30 minutes [] 1 onsite within 30 minutes CALL-IN __ 1 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> LI 1 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> TOTAL TOTAL: 2 Available onsite within 30 TOTAL 2 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> minutes and 2 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> TOTAL 3 onsite within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />

9. Verify that Maintenance Call List is available. As necessary call in additional maintenance personnel for your discipline.

OPERATIONAL RESPONSIBILITIES

"* Provide Mechanical, Electrical, and Instrument technical expertise.

" Evaluate job conditions (including RADCON, Fire Operations, and Operational aspects of the task) and analyze the necessary precautions and methods best suited to safe performance of the task.

" When possible combine Damage Assessment and Repair Teams.

Continued Next Page

ACTIVATION AND OPERATION OF THE IEPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 Page 27 of 36 Date:

APPENDIX L Page 2 of 2 OSC BRIEFER CHECKLIST OPERATIONAL RESPONSIBILITIES Continued

"* Brief the OSC Teams based on the analysis of the job.

"* Track the OSC Teams while in the field.

"* Debrief the OSC Teams after completion of the Task.

"* Complete applicable portions of the OSC Team Briefing/Tracking and Debriefing Forms (Appendix D) and forward to OSC Manager.

I TIVATION AND OPERATION OF THE IEPIP-7 Rev.18 SQN OPERATIONS SUPPORT CENTER Page 28 of 36 Date:

APPENDIX M Page 1 of 1 OSC INDUSTRIAL SAFETY ADVISOR CHECKLIST Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing chart and obtain OSC badge.
3. Notify the OSC Manager of arrival.
4. Establish a log of activities and communications.
5. Notify the Assistant OSC Manager of arrival.
6. Notify Fire Ops Advisor of arrival.

OPERATIONAL RESPONSIBILITIES 9 Provide and coordinate Industrial Safety personnel needed to support the OSC.

0 Evaluate plant environment.

  • Provide recommendations to OSC management concerning the safety aspects of Emergency Response team tasks.

SQ ACTIVATION AND OPERATION OF THE EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev. 1829 of 36 1Page 1 1 Date:

APPENDIX N Page 1 of 1 PERSONNEL POOL MANAGER CHECKLIST INITIAL ACTIVATION OF THE OSC Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the organization/Staffing Chart and obtain OSC badge.
3. Establish a log of communications and activities.
4. Establish communications with the Assistant OSC Manager and/or Briefer.
5. Locate all teams previously tasked and ensure assignment of Team Tracking Letter designation for tracking and debriefing.
6. Ensure at least two teams are fully staged outside OSC in the cafeteria.

OPERATIONAL RESPONSIBILITIES

"* Form teams as requested by the OSC.

"* Manage personnel in the OSC Staging Area by:

1. Directing personnel to enter keycards into the Accountability Card Reader (at cafeteria entrance).
2. Directing responders (potential OSC teams) to check-in with the HIS-20 Operator.
3. Requiring potential/actual OSC Team members to dress out.
4. Maintain command and control (quiet/orderly) in OSC Staging Area.

"* Recover personnel for future members.

"* Ensure at least one team on standby at all times.

"* Validate qualifications of team members by completing the information on Appendix R, including remaining allowable dose (RAD)

I ACTIVATION AND OPERATION OF THE EPIP-7 Rev.18 SQN OPERATIONS SUPPORT CENTER DaPage 30 of 36 Date:

APPENDIX 0 Page 1 of 1 DCRM Coordinator Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing chart and obtain OSC badge.
3. Notify the OSC Manager of arrival.
4. Establish a log of activities.
5. Log in on computer.
6. Notify the Assistant OSC Manager and/or Briefing Teams DCRM information is available on request.

OPERATIONAL RESPONSIBILITIES

"* Provide DCRM expertise as needed.

"* Provide drawings, documents, vendor manuals as requested.

"* Assist in OSC logistics as requested.

IACTIVATION AND OPERATION OF THE I EPIP-7 Rev.18 SQN OPERATIONS SUPPORT CENTER Page 33 of 36 Date:

APPENDIX R Page 1 of 1 PERSONNEL POOL MGR. LOG CRAFTSMAN SECTION NAME SSN CRAFT HIS-20 OPERATOR SECTION HIS-20 OPERATOR:

TLD# RAD SCBA RESP REP mRem QUAL QUAL TRAINED w YES w1 YES w1 YES

[I NO [I NO El NO PERSONNEL POOL MGR SECTION CRAFT:

RAD ASSIGNED TO BRIEFER COMMENTS mRem* TEAM #

(Same as above)

I i - z I I +

______ j. 4- 4

______ .1. 4

.1. 4 I I i aepenaing on asslgneu I rn WK. r¶.PLJ Will I IU mRem can change can LU LJ RAD

  • verified RAD mi em completion change t epenAing Team on ametaskibeforeassignm. enU to ao=tU another teU after of Assigned task before assignment Wto U team.

IACTIVATION SON OPERATIONSAND OPERATION SUPPORT CENTEROF THE EPIP-7 Rev. 18 I Page 31 of 36 Date:

APPENDIX P Page 1 of 1 OSC Materials Coordinator Time/

Initials

1. Swipe Accountability Reader.
2. Fill out the Organizational/Staffing chart and obtain OSC badge.
3. Notify the OSC Manager of arrival.
4. Establish a log of activities.
5. Log in on computer.
6. Establish contact Power Stores Personnel at X-7155.
7. Notify the Assistant OSC Manager or Briefing Teams material expediting information is available on request.

OPERATIONAL RESPONSIBILITIES

"* Provide coordination between Power Stores and OSC.

"* Provide materials as expeditiously as possible for emergency response.

"* Operate computer to determine materials availability.

"* Coordinate safety of warehouse personnel with the OSC Manager and RADCON Supervisor.

I ACTIVATION AND OPERATION OF THE IEPIP-7 Rev.18 SQN OPERATIONS SUPPORT CENTER Page 32 of 36 Date:

APPENDIX Q Page 1 of 1 Telephone Lists can be found in the REND TELEPHONE LIST REND LOCATION FAX Machine Numbers Section A Item # 8 CECC Numbers Section B Item # 1 TSC Numbers Section B Item # 9 OSC Numbers Section B Item # 10 Tennessee State Numbers Section E Item # 2 Communications Support Section I Medical Support Numbers Section K Meteorological Support Section L Numbers

(

I I ACTIVATION AND OPERATION OF THE EPIP-7 SQN OPERATIONS SUPPORT CENTER Rev.18 Page 34 of 36 Date:

Appendix S Page 1 of 2 ERO ROSTER NAME (Print) SIGNATURE SSN PS EROONAMEREPLACEMENT'S NOTIFIED AND FFD POSITION _ ____YES NO I I t 1 I 1= I t 1-I

1. I I t I I f I I t 1 I

_______________________________ I *I* I *t I

_______________________________ 1 4 I I I

_ _ _ _ 1 I__ 4 a i I I I i i i I I 11 L-Date of OSC Activation: EP Records Coordinator:

I CTIVATION AND OPERATION OF THE IEPIP-7 Rev.18 SQN OPERATIONS SUPPORT CENTER Page 35 of 36 Appendix S Page 2 of 2 EMERGENCY RESPONDER NOTIFICATION FORM Fitness for Duty Person Calling Date NaeTime Time Have Consumed you Are you Name Called Needed Alcohol 5 Hrs. Fit for Comments to Prior to Duty?

Report Report Time?

YES NO YES NO 4 4 + I t1

___________________________ I 1- 4 + I 4.

i 1 t-t i i i i -i  ! t

4. + + I t I I
4. i i i - i 1

+ 4 + 1 1 I 4 F I + I I 4 1 I + I I I I1 i i il i il i i _____________________________

ACTIVATION AND OPERATION OF THE EPIP'7 SQN OPERATIONS SUPPORT CENTER Rev.18 CPaEe 36 of 36 S

SOURCE NOTES REQUIREMENTS IMPLEMENTING STATEMENT SOURCE DOCUMENT STATEMENT NP Radiological Emergency Plan (NP-REP)

TENNESSEE VALLEY AUTHORITY SEQUOYAH NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE EPIP-14 RADIOLOGICAL CONTROL RESPONSE Revision 15 QUALITY RELATED PREPARED: W. P. Brooks RESPONSIBLE ORGANIZATION: Emergency Preparedness APPROVED BY: John Casey EFFECTIVE DATE: 9-1-2000 LEVEL OF USE: REFERENCE REVISION DESCRIPTION: Intent Change: Revision added Chemistry responsibility to ensure minimum staffing level and need for additional call-in staff. Revised to reflect KI package change. Remove the RCSS role as TSC RADCON Manager. Added further directions for Chemistry on determining release and dose rates.

TABLE OF CONTENTS Section Title Page Table of Contents ............................................................................. 2 1.0 P URP O S E .............................................................................................. 3

2.0 REFERENCES

.................................................................................. 3 3.0 INSTRUCTIONS ............................................................................... 3 3.1 Initiation of an Alert ........................................................................... 3 3.2 TSC Radcon Manager Responsibilities ............................................ 4 3.3 Activation of the Operations Support Center ...................................... 5 3.3.1 OSC RADCON Supervisor ................................................................ 5 3.4 Radcon Lab Responsibilities .............................................................. 6 3.4.1 Designated RCSS ............................................................................. 6 3.5 Chemistry Response ......................................................................... 7 3.5.1 Designated Chemistry Personnel ...................................................... 7 3.6 General Response ............................................................................. 7 3.6.1 All RADCON Personnel ..................................................................... 7 3.7 Issuance of Potassium Iodide (KI) ...................................................... 9 3.8 Use of Silver Zeolite Cartridges ....................................................... 10 3.9 Personnel Decontamination and Facilities ...................................... 10 APPENDIXES Appendix A, Inplant Radiation Monitors ........................................... 11 Appendix B, Potassium Iodide Issue Report .................................... 12 Appendix C, Occupational Thyroid Dose From Inhalation of Iodine-1 31 ................................................................ 13 Appendix D, Methodology for Projecting TEDE ................................ 14 Appendix E, Fitness For Duty Program Admin Call-In Sheet ....... 24 SOURCE NOTES .............................................................................. 25

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 3 of 25 1.0 PURPOSE To describe the actions and responsibilities of Sequoyah's Radiological Control (RADCON) and Chemistry Sections in the event of a radiological emergency.

2.0 REFERENCES

2.1 Interface Documents A. EPIP-7, "Activation and Operation of the Operations Support Center (OSC)"

B. EPIP-8, "Personnel Accountability and Evacuation" C. CECC-EPIP-9, "Emergency Environmental Radiological Monitoring Procedures" D. RCI-20, "Radioiodine Monitoring During Accident Conditions" E. 0-TI-CEM-030-030.0, "Manual Calculation of Plant Gas, Iodine, and Particulate Release Rates for Offsite Dose Calculation Manual (ODCM)

Compliance" 2.2 Developmental Documents A. EPIP-6, "Activation and Operation of the Technical Support Center" B. EPIP-10, "Medical Emergency Response" 3.0 INSTRUCTIONS 3.1 Initiation of an Alert Upon initiation of an Alert, Site Area Emergency, or General Emergency, the RADCON and Chemistry Sections will assemble a specific number of personnel as described below.

A. During normal and off-shifts a Radiological Emergency Plan (REP) activation will be announced over the public address system or the emergency sirens may be activated and the Emergency Paging System (EPS) will be activated. The RADCON Lab will be contacted by the Shift Manager or.designee. The RADCON Shift Supervisor (RCSS) will determine the number of ANSI qualified RADCON personnel currently onsite and shall ensure that at least a total of eight (8) (not counting him/herself) are available onsite within approximately 30 minutes and at least fourteen (14) (counting him/herself if qualified) are available onsite within one hour [six (6) additional ANSI qualified RADCON personnel within the second 30 minutes]. Call ins shall be in accordance with Appendix E ensuring that Fitness For Duty questions are asked and response documented. Additional RADCON support personnel may need to be called in using Appendix E.

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 4 of 25 3.1 Initiation of an Alert (Continued)

B. The Chemistry Lab will be contacted by the Shift manager or designee.

The Chemistry Shift Supervisor (CSS) will determine the number of chemistry technicians currently onsite and shall ensure that at least a total of two (2) chemistry technicians (counting the CSS if qualified) are available onsite within approximately 30 minutes and at least a total of three (3) are available onsite within one hour if the Offsite Dose Assessment function has not been assumed by other staff. Call ins shall be in accordance with Appendix E ensuring that Fitness For Duty questions are asked and response documented. Additional (above the minimum required staffing) Chemistry support personnel may need to be called in, use Appendix E to document.

C. Chemistry Shift Supervisor (CSS) shall perform Dose Assessment in accordance with Appendix D when notified by the Shift Manager or Site Emergency Director.

D. When the OSC is staffed by the OSC Radcon Supervisor (OSC RCS), the RCSS shall assemble two survey teams and dispatch them to the OSC for briefings and dressout.

E. The TSC and OSC are activated during an Alert, Site Area Emergency or General Emergency.

F. All response teams, except as listed in EPIP-7, will be dispatched from the OSC and should have a RADCON representative as a member. If the Fire Brigade, Medical Emergency Response Team or Damage Control Team is already responding they are not required to return to the OSC to be dispatched, but shall be tracked and briefed by the OSC in accordance with EPIP-7, Section 3.2.5. RADCON survey teams may be dispatched from the lab but shall be tracked by the OSC.

G. All response teams shall be debriefed by the OSC after completing their team assignment.

3.2 TSC RADCON Manager (RCM) Responsibilities The responsibilities and duties of the TSC RADCON representative are detailed in EPIP-6. A summary of the details associated with these responsibilities are provided below.

A. The primary responsibilities of the RCM are to direct onsite radiological surveillance activities, assess inplant and onsite radiological conditions and to make this information available to the Site Emergency Director (SED), the Central Emergency Control Center (CECC) and other TSC personnel as necessary, to support and coordinate protective actions.

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 5 of 25 3.2 TSC RCM Responsibilities (Continued)

B. To facilitate the evaluation of in-plant radiological conditions and to establish trends. Appendix A lists the radiation monitors [i.e., Area Radiation Monitors (ARMs) and Continuous Air Monitors (CAMs)] that may be used.

C. The RCM, together with other TSC personnel, evaluates plant conditions to anticipate future developments and formulates corrective action plans to address actual or postulated conditions. The RCM renders recommendations and advises the SED on radiological issues.

D. The TSC RCM communicates with the CECC Plant Radiological Communicator, providing pertinent in-plant radiological data so that appropriate offsite protective actions can be implemented in a timely manner.

E. The TSC RCM maintains communications with the OSC RADCON Supervisor (RCS), constantly evaluating inplant radiological conditions, recommending and identifying the need for radiological surveys.

F. When directed by the Site Emergency Director, establishes a contamination checkpoint for personnel and vehicles leaving the site.

G. Issues Potassium Iodide in accordance with 3.7 of this procedure.

3.3 Activation of the Operations Support Center 3.3.1 OSC RADCON Supervisor (RCS)

The OSC RCS is a trained and qualified individual designated by the RADCON Manager. The approved alternates are listed in the Call List.

The responsibilities and duties of the OSC RCS are detailed in EPIP-7. A summary of the details associated with these responsibilities are provided below:

A. The primary responsibilities of the OSC RCS are to ensure that, when required, a RADCON tech accompanies each team; detailed radiological briefings are provided to OSC team members; and the OSC Director and OSC Staff are knowledgeable of in-plant radiological conditions. He also serves as the interface between the TSC and the RADCON Lab.

B. Maintains awareness of in-plant radiological conditions and related parameters and reports those conditions to the TSC RCM.

C. Communicates directly with the TSC to coordinate inplant response activities. Assists in the development of briefing notes, and radiological condition updates.

D. In conjunction with the TSC, identifies the need, location, and extent of radiological surveillance activities required to assess or mitigate the consequences of the accident.

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 6 of 25 3.3 Activation of the Operations Support Center (Continued)

E. All teams are dispatched from the OSC except as described in paragraph 3.1..F. The OSC RCS is responsible for ensuring that personnel making entries into the plant, including survey teams, are aware of any special precautions, plant conditions, or requirements and are assigned team tracking numbers.

F. Ensure that OSC Team members are instructed to note their Remaining Allowable Dose (RAD) upon exiting the RCA and to provide their current RAD to the Personnel Pool Manager when they return to the OSC. The Personnel Pool Manager will update their RAD in his log.

Repetitive exposures of workers should be restricted by substituting other qualified personnel for team members, on reentry, to distribute exposures. As a minimum, OSC Team members' RAD shall be verified prior to entry into plant areas under a Site Area Emergency or General Emergency.

G. Report all survey results as soon as possible to the TSC so they can make recommendations to the proper agencies to initiate any required protective actions.

3.4 RADCON Lab Responsibilities 3.4.1 Designated RCSS The designated RCSS is responsible for managing the activities of the RADCON lab.

A. In the event of an Alert, Site Area Emergency, or General Emergency the OSC may become the staging area for entries into affected plant areas.

B. A RADCON Representative should accompany all emergency response teams when initial entries are made into affected plant areas.

C. The RCSS is responsible for ensuring that adequate numbers of RADCON representatives are available, in accordance with paragraph 3.1 .A, to support emergency activities and that two (2) survey teams are dressed out and ready for briefing.

D. The RCSS is responsible for preparing and designating an onsite RADCON environmental monitoring team. Team members will prepare and operate the monitoring van in accordance with CECC-EPIP-9.

Record all survey results. If results indicate offsite contamination, the survey areas may need to be expanded. Obtain further instructions and perform required surveillance.

E. The RCSS will dispatch survey teams to assembly areas, the OSC and TSC to evaluate radiological conditions, monitor radiation levels as conditions dictate and ensure updated habitability surveys are performed. These survey teams will continuously monitor contamination levels as needed both on personnel and floor/equipment areas and implement corrective actions (e.g., decontamination or zoning) as necessary.

3.4 RADCON Lab Responsibilities (Continued)

F. The RCSS will monitor the lab for habitability and will coordinate evacuation activities to the alternate lab location if warranted.

G. The RCSS will ensure all survey teams are tracked by the OSC.

H. The RCSS will ensure DAC-hour exposure when available and RAD calculations are completed and reported to the OSC RCS.

I. The RCSS will ensure respiratory protection is issued as needed.

J. Ensure that HIS-20 entries are properly made and that all dosimetery is properly issued, collected and identified for each worker. Make arrangements to have TLD badges read, as soon as possible.

3.5 Chemistry Response 3.5.1 Designated Chemistry Personnel The designated Chemistry personnel are responsible for managing the activities of the Chem Lab.

A. The CSS is responsible for ensuring that adequate numbers of chemistry personnel are available in accordance with paragraph 3.1 .B.

B. In the event of an alert, site area emergency or a general emergency, due to a radiological release, a plant total gas release rate (source term) may need to be determined in accordance with Appendix D of this procedure.

C. Upon request of the Shift Manager (SM), Chemistry personnel will determine the plant source term that shall be reported to the SM for classification purposes and protective action recommendations to the state.

D. The source term shall be reported to the CECC dose assessment staff, when the CECC is manned, for input into a preliminary dose assessment.

E. Projected dose at the site boundary, 2 miles and 5 miles may be determined in accordance with Appendix D.

3.6 General Response 3.6.1 All RADCON Personnel All RADCON personnel should comply with the following:

A. The following precautions should be considered during emergency incidents.

Anticipated Conditions Protective Considerations

1. Noble gas concentrations If fuel damage has occurred

> 1 x 10- pci/cc or is suspected, respirators should be worn (ensuring TEDE is ALARA).

2. Iodine concentrations SCBA

> 10 DAC

3. Particulate concentrations Particulate mask or SCBA

> 10 DAC (SCBA recommended if > 50 DAC).

4. Standing water> 1" Rain suits, rubber boots, Extremity dosimetry.

B. If it is necessary to evacuate the RADCON lab, then the personnel stationed in the lab will secure the equipment listed in EPIP-17, Appendix C. This equipment will be brought to the alternate lab by RADCON. This list is a minimum and if time permits and manpower allows, then efforts should be made to transport additional equipment and supplies to the alternate lab. The SED shall be informed when it becomes necessary to evacuate the 690' RADCON lab. If this situation develops, a RADCON Lab will be established adjacent to the TSC.

This alternate lab should be set-up in the switchgear room, El 732' or other suitable area, as emergency conditions allow (the TSC RCM is responsible for making this determination). This lab will be equipped with necessary supplies and instrumentation needed to perform minimum radiological surveys and analysis required during an emergency.

C. If severe radiological conditions are suspected, the "Buddy System" shall be utilized.

D. If time is available, an RWP should be issued to cover entry teams; if not, suitable protective measures should be taken in accordance with established procedures.

E. When accountability is initiated RADCON personnel shall secure work in a safe manner and proceed to the 690' RADCON Lab and/or other designated assembly areas. An accountability will be made in accordance with EPIP-8. RADCON representatives may be sent to the assembly areas to determine if any workers were in the affected plant areas at the time of the event. These people shall be separated from other plant workers and personnel contamination surveys should be initiated for all personnel.

F. Radiation monitor readings may be obtained from Control Room personnel or an individual may be sent to the Control Room to record the necessary values. Readings are obtained from panels 0-M-12 and 1/2-M-30 and recorded on Appendix A. As radiation monitor readings are updated, the OSC RCS ensures labs will be contacted to ensure that their status boards are made current.

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 9 of 25 3.6 General Response (Continued)

G. As reports become available regarding the details of the emergency, RADCON personnel shall prepare all necessary equipment needed during recovery and report to the OSC as needed to ready survey or damage control team(s) for entry into the affected area(s).

Upon notification from the RCS in the OSC, the survey team(s) may proceed to the specified area. It should be noted that depending on the type of accident, this initial survey may not be performed until hours or perhaps even days after the event. In this case, procedures may be developed describing the reentry steps to be followed. Other essential personnel may be required to assist in reentry activities.

3.7 Issuance of Potassium Iodide (KI)

A. If a person's projected cumulative dose to the thyroid from inhalation of radioactive iodine might exceed 10 rem, the exposed person should be started immediately on a dose regimen of KI. Authorization to issue KI is the responsibility of the TSC RCM. He shall inform the SED prior to issuance. Anyone authorized to administer KI shall be familiar with the Food and Drug Administrations approved package insert and ensure that each proposed recipient is similarly informed. The initial dose of KI should not be delayed and those who begin therapy should continue the 10-day course of KI unless their thyroid dose is determined not to have exceeded 10 rem. An adequate supply of KI is stored onsite. It is supplied in blister packs which contain a full 10-day dose regime.

Follow dosage schedules as outlined on the package.

B. Projected cumulative doses to the thyroid from inhalation of radioactive iodine can be estimated using Appendix C "Occupational Thyroid Dose from Inhalation of 1-131."

C. Potassium iodide is stored in the OSC. KI has an approved shelf-life with the expiration date listed. To ensure that the KI supply is valid, these dates will be inspected and the KI replaced as necessary.

D. A copy of the Food and Drug Administration approved instructions shall accompany issue of KI. Dosage schedules and other pertinent information are outlined on the package insert and should be followed closely.

E. The issuing agent shall complete the Potassium Iodide Issue Report (Appendix B) for KI issued. A copy of this report will be routed to the TSC RCM in a timely manner.

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 10 of 25 3.8 Use of Silver Zeolite Cartridges A. During accident conditions noble gas concentrations may be present in significant quantities both inplant and offsite. The collection of these noble gases on charcoal cartridges during iodine sampling will interfere with subsequent iodine analysis.

B. Silver zeolite cartridges are provided for use during periods of high noble gas concentrations. RCI-20 describes the utilization of and lists hazards associated with Silver Zeolite cartridge use.

3.9 Personnel Decontamination and Facilities A. RADCON will use established procedures for personnel decontamination. Decontamination facilities are available for use by Sequoyah personnel.

B. Contaminated personnel are normally decontaminated at the 690' elevation decon facility. This facility is equipped with a wash sink, shower, and all necessary supplies. These supplies include various decontamination agents and soaps, towels, clean clothing, and other miscellaneous supplies.

Contaminated personnel requiring offsite medical attention are treated at the agreement hospital(s). The hospital has a complete staff that has been trained in the handling and care of contaminated patients.

Emergency Preparedness maintains a supply cabinet at the hospital's Emergency Room which contains posting materials and various other supplies. EPIP-10 contains guidelines for RADCON assistance during a medical emergency or hospital treatment.

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 11 of 25 APPENDIX A Page 1 of 1 IN PLANT RADIATION NIONITORS Affected Unit DESCRIPTION IDENTIFIER INITIAL UPDATED READINGS READING DATE TIME READING PANEL 0-M-12 SPENT FUEL PIT AREA RADMON 1/2-RM-90-1 mRlhr SFP AREA RADMON O-RM-90-5 mR/hr CCS HXS AREA RADMON 1/2-RM-90-6 mR/hr HOT SAMPLE ROOM AREA RADMON 1/2-RM-90-7 mR/hr AFW PUMPS AREA RADMON 1/2-RM-90-8 mR/hr CNDS WASTE TKS AREA RADMON O-RM-90-9 mR/hr CVCS BD AREA RADMON 1/2-RM-90-1 0 mR/hr CNTMT SPRAY AND RHR PUMPS O-RM-90-11 mR/hr RADMON CNTMT UPPER COMPT RADMON- 1/2-RM-90 TOTAL GAS 112B CPM CNTMT LOWER COMPT RADMON TOTAL GAS 112-RM-90 106B CPM PANEL 112-M-30 1/2-RI-90-400 Low Range 1iCI/cc SHIELD BLDG VENT MON RAD Mid Range j.CI/cc INDICATOR High Range ýiCI/cc Effluent _.CI/sec SAMPLE ROOM POST ACCIDENT 1/2-RM-90-280 AREA MONITOR mR/hr RHR POST ACCIDENT AREA MONITOR

-LO RNGE 1/2-RM-90-290 mR/hr

-HI RNGE 1/2-RM-90-291 mR/hr

-LO RNGE 1/2-RM-90-292 mR/hr

-HI RNGE 1/2-RM-90-293 mR/hr Route to EP Manager Data Taker Signature Time Date

/ SQN RADIOLOGICAL CONTROL RESPONSE EPIP-1 4 Rev. 15 Page 12 of 25 I I APPENDIX B Page 1 of 1 POTASSIUM IODIDE ISSUE REPORT TIME OF I NUMBER INFORMATION ISSUED BY DATE NAME SS NUMBER EXPOSURE PERIOD INITIAL KI OF DOSES INSTRUCTIONS ISSUED DOSE ISSUED ISSUED

____________ 1. I I I t I

i. i Ii i 1 I I I t t I i i i I i i i 4 i i t i T

____________ 1 1. 1 + I I I I I t I I

____________ I I I + I I I '1 1 t

_ _ _ _ I__ I i i i Iii I- I *1 I t I

____________ 1. I I I I 1 I. I + I I

____________ 4 1 1 I I I V 4 1 1 I t I I

____________ 4 4 4 1 1 1 t i i 1 i t -i I

____________ I I I I I I I 1 1 1 moute to r-mergency -repaey u ,e..au

(sjnoq) ew!lj ainsodx3l 001- 0M. L. L0 30-300"*

....................... ...... gO-00" I.

I ......................... .....................................


LO-00" I

......... ........................ ............. ................................................. 00


.... ............... ......... . .. . CD

........ ............... .......................90-300 L=

............. .................... .............. ..... ... ...... I................. ...............

wei Oý-+ .............................

  • ,.*....................... . .....3
...... 0 Wei' 09 0--- ....................... ........................................................ .................. .......................... ...

..... ................................................. I............................... ............. ........ ........ .......... ...................... 170-300*

........... I........................................... ................................. .................... ..... .. ........ ..... ...................

Ir.. ..............................


............... ................. SO-3O0" cVIo

o uoeieqetui wotjl esoo ploiAqj. IeuO!edflOOo I, .o s Oed o XIaN3ddV 9Z Cl
-10 Nd t'L-dId3 HSNOdSHU iQUINQO 1VOID1OIGVUa NOS

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 14 of 25 APPENDIX D Page 1 of 10 METHODOLOGY FOR PROJECTING TEDE A. TO DETERMINE THE PROJECTED OFF-SITE TEDE AND THYROID CDE.

1. If there is a release to the environment from a ruptured Steam Generator (via atmospheric relief, safety valve, or un-isolated line break outside of containment) then go to Step 4 below.
2. From the effected unit ICS Main Menu click on "GROUP DISP MENU" then click on "DOSE ASSESSMENT" (Fig. 2) and read the TEDE and THYROID CDE dose rate in REM at the SITE BOUNDARY (EAB), 2 MILES, and 5 MILES (Fig. 3).

PROVIDE THESE VALUES TO THE SM/SED TO DETERMINE EVENT CLASSIFICATION AND PROTECTIVE ACTION RECOMMENDATIONS.

NOTE: Ifthe "DOSE ASSESSMENT" feature is not working then projected TEDE and THYROID CDE must be manually calculated. The following parameters will be required to determine TEDE and THYROID CDE at the desired distance: Plant Total Gaseous Rad Release Rate (Source Term), Wind Speed and, Atmospheric Stability Class. Revisions to the factors or any referenced software in this appendix requires revalidation of the calculations by Chemistry.

3. The "PLANT TOTAL GASEOUS RAD RELEASE" may be determined as follows: From the effected unit ICS Main Menu type "SHOW RAD025. Enter the value in the blank in (page
16) C.1.c.

PROVIDE THIS VALUE TO THE SM/SED TO DETERMINE EVENT CLASSIFICATION AND PROCEED WITH SECTION B.

OR

4. Notify the Chemistry Shift Supervisor to complete Appendix A (if RAD025 is not available) or Appendix G (if RAD025 is available) of 0-TI-CEM-030-030.0. Enter the release rate pCi/sec value in the blank in (page 16) C.1 .c.

PROVIDE THIS VALUE TO THE SM/SED TO DETERMINE EVENT CLASSIFICATION AND PROCEED WITH SECTION B.

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 15 of 25 APPENDIX D Page 2 of 10 B. DETERMINE THE WIND SPEED AND ATMOSPHERIC STABILITY CLASS.

1. On the affected Unit ICS Main Menu click on "SECONDARY MIMICS" button.
a. On the Secondary Mimics page click on "MET DATA" button. (Figure 4)
b. From the "MET-TOWER LINK" page (Figure 5) or the "FRED MET DATA" page (Figure 6) record the 46 Meter Ave. Wind Speed (15 Min) = _ mph, Enter in blank in C.1 .a.

for NOTE: If not available, call the National Weather Service in Morristown, TN, (423) 586-8400 wind speed. Enter in blank in C.l.a.

c. From the "FRED MET DATA" page record the Stability Class 46-10 Mtr 15 Min Avg. =

(e.g., A, B, C, etc.). This is the atmospheric stability class. Enter in blank in C.l.b.

2. If the Atmospheric Stability Class is not displayed then determine it as follows:
a. Return to the "MET-TOWER LINK" page (Figure 5) and click on the "STABILITY DELTA-T's" button.
b. From the "STABILITY DELTA-T's" page (Figure 7) record the "VERTICAL AIR TEMP DELTA T 46-10 METERS (INSTANTANEOUS)"_= DEG F and refer to the table below.

OR

["46 METER AIR TEMP (INSTANTANEOUS)"_= DEG F] minus ["10 METER AIR TEMP (INSTANTANEOUS)" = DEG F]= DEG F and refer to the table below.

c. Using the Atmospheric Stability Class Table below with the DEG F value from 2.b. above, determine the stability class. Atmospheric Stability Class = . Enter in blank in C.1.b.

ATMOSPHERIC STABILITY CLASS TABLE DEG F CLASS

< minus 1.3 uF A 0 B

> minus 1.3 < minus 1.2 F 0 C

> minus 1.2 < minus 1.0 F 0 D

> minus 1.0 < minus 0.4 F

> minus 0.4 < 0.9°F E 0 F

> 0.9 < 2.6 F

> 2.6 OF G

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 16 of 25 APPENDIX D Page 3 of 10 C. DETERMINE THE PROJECTED TOTAL DOSE EQUIVALENT (TEDE) AT THE SITE BOUNDARY, 2, OR 5 MILES.

1. Obtain the appropriate meteorological and release rate data and enter below:
a. Wind Speed =_ mmi/hr from B.1.b.
b. Stability Class = from B.1.c or B.2.c.
c. Plant Total Noble Gas Release Rate = ItCi/SEC from A.2 or A.3.
2. From the TEDE FACTOR TABLES, (Figure 1), find the appropriate table for the stability class. Then, find the desired distance range in miles on the vertical scale and the wind speed on the horizontal scale. Record the corresponding TEDE FACTOR in 3 below. For wind speeds that fall between the values in the table, default to the lower wind speed.

This is the more conservative value.

3. 0.62-1.99 miles TEDE FACTOR = rem/hour per p.Ci/sec.

2.00-4.99 miles TEDE FACTOR = rem/hour per pCi/sec.

5.00-10.0 miles TEDE FACTOR = rem/hour per pCi/sec.

4. Obtain an estimate of the release duration (t)= hour(s).
5. TEDE = [TEDE FACTOR(@ desired distance)]x(Plant Total Noble Gas Release Rate)x(t)=

REM @ 0.62-1.99 miles. (Site Boundary)

REM @ 2.00-4.99 miles. (2 Miles)

REM @ 5.00-10.0 miles. (5 Miles)

6. If Type II release due to fuel overheat or melt, Then multiply the calculated dose in step 5 by 3.2.

Step 5 x 3.2 = REM @ 0.62-1.99 miles. (Site Boundary)

Step 5 x 3.2 = REM @ 2.00-4.99 miles. (2 Miles)

Step 5 x 3.2 = REM @ 5.00-10.0 miles. (5 Miles)

7. Compute the Thyroid CDE at each distance by multiplying the TEDE values by a factor of ten. (CDE = TEDE x 10)

REM @ 0.62-1.99 miles. (Site Boundary)

REM @ 2.00-4.99 miles. (2 Miles)

REM @ 5.00-10.0 miles. (5 Miles)

8. PROVIDE STEP 5 OR 6 AND STEP 7 VALUES TO THE SM/SED TO DETERMINE EVENT CLASSIFICATION AND PROTECTIVE ACTION RECOMMENDATIONS.

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 17 of 25 APPENDIX D Page 4 of 10 FIGURE 1 TEDE FACTOR TABLES TEDE FACTOR (rem/hr per gCi/s) FROM A GROUND-LEVEL RELEASE Stability Class A Wind Speed (mi/h) 6.7 mi/h 8.9 mi/h 11.2 rni/h 13.4 mi/hJ15.7 mi/h 17.9 mi/h 20.1 mi/h 22.4 mi/h miles 2.2 mi/h 4.5 mi/h 0.62-1.99 5.1E-10 2.5E-10I 2.OE-10 1.5E-10 1.OE-10 9.1E-11 8.1E-11 7.1E-11 6.1E-11 5.1E-11 2.00-4.99 1.7E-10 8.7E-11 7.OE-11 5.2E-11 3.5E-11 3.1E-11 2.8E-11 2.4E-11 2.1E-11 1.7E-11 6.3E-11 3.4E-11 2.8E-11 2.2E-11 1.6E-11 1.4E-11 1.3E-11 1.1E-11 9.5E-12 7.9E-12 5.0-10.0 Stability Class B Wind Speed (mi/h) 4.5 mi/h 6.7 mi/h 8.9 mi/h 11.2 mi/h 13.4 mi/h 15.7mi/h 17.9 mi/h 20.1 mi/h 22.4 mi/h miles 2.2 mi/h 0.62-1.99 2.3E-09 1.2E-09 9.4E-10 7.1 E-1 0 4.7E-10 4.3E-10 3.8E-10 3.3E-10 2.8E-10 2.3E-10 2.00-4.99 2.3E-10 1.2E-10 9.2E-11 6.8E-11 4.5E-11 4.1E-11 3.6E-11 3.2E-11 2.7E-11 -2.3E-11 8.2E-11 4.6E-11 3.7E-11 2.9E-11 2.1E-11 1.9E-11 1.7E-11 1.5E-11 1.2E-11 1.0E-11 5.0-10.0 Stability Class C Wind Speed (mi/h) 6.7 mi/h 8.9 mi/h 11.2 mi/h 13.4 mi/h 15.7 mi/h 17.9 mi/h 20.1 mi/h 22.4 mi/h miles 2.2 mi/h 4.5 mi/h 0.62-1.99 6.8E-09 3.5E-09 2.8E-09 2.1E-09 1.4E-09 1.2E-09 1.1E-09 9.6E-10 8.2E-10 6.8E-10 2.00-4.99 9.3E-10 4.5E-1 0 3.7E-10 2.8E-10 1.9E-10l 1.7E-10 1.5E-10 1.3E-10 1.1E-10 9.3E-11 1.6E-10 9.1E-11 7.5E-11 5.8E-11 4.2E-11 3.7E-11 3.3E-11 2.9E-11 2.5E-11 2.1E-11 5.0-10.0 Stability Class D Wind Speed (mi/h) 4.5 mi/h 6.7 mi/h 8.9 mi/h 11.2 mi/h 13.4 mi/h 15.7 mi/h 17.9 mi/h 20.1 mi/h 22.4 mi/h miles 2.2 mi/h 0.62-1.99 2.0E-08 1.OE-08 8.OE-09 6.OE-09 4.1E-09 3.6E-09 3.2E-09 2.8E-09 2.4E-09 2.OE-09 2.00-4.99 3.3E-09 1.7E-09 1.4E-09 1.OE-09 6.8E-10 6.2E-10 5.5E-10 4.8E-10 4.1E-10 3.5E-10 6.9E-10 3.9E-10 3.2E-10 2.5E-10 1.8E-10 1.6E-10 1.4E-10 1.2E-10 1.OE-10 8.7E-11 5.0-10.0 Stability Class E Wind Speed (mi/h) 4.5 mi/h 6.7 mi/h 8.9 mi/h 11.2 mi/h 13.4 mi/h 15.7 mi/h 17.9 mi/h 20.1 mi/h 22.4 mi/h miles 2.2 mi/h 0.62-1.99 3.5E-08 1.7E-08 1.4E-08 1.OE-08 7.OE-09 6.3E-09 5.6E-09 4.9E-09 4.2E-09 3.5E-09 2.00-4.99 6.6E-09 3.3E-09 2.7E-09 2.OE-09 1.3E-09 1.2E-09 1.1E-09 9.3E-10 7.9E-10 6.6E-10 1.5E-09 8.2E-10 6.7E-10 5.3E-10 3.8E-10 3.4E-10 3.1E-10 2.7E-10 2.3E-10 1.9E-10 5.0-10.0 Stability Class F Wind Speed (mi/h) 4.5 mi/h 6.7 mi/h 8.9 mi/h 11.2 mi/h 13.4 mi/h 15.7 mi/h 17.9 mi/h 20.1 mi/h 22.4 mi/h miles 2.2 mi/h 0.62-1.99 6.6E-08 3.3E-08 2.7E-08 2.OE-08 1.3E-08 1.2E-08 1.1E-08 9.3E-09 8.0E-09 6.6E-09 2.00-4.99 1.5E-08 7.6E-09 6.1 E-09 4.6E-09 3.1E-09 2.8E-09 2.5E-09 2.2E-09 1.8E-09 1.5E-09 5.0-10.0 3.8E-09 2.1E-09 1.7E-09 1.3E-09 9.6E-10 8.6E-10 7.7E-10 6.7E-10 5.7E-10 4.7E-10 Stability Class G Wind Speed (mi/h) 6.7 mi/h 8.9 mi/h 11.2 mi/h 13.4 mi/h 15.7 mi/h 17.9 mi/h 20.1 mi/h 22.4 mi/h miles 2.2 mi/h 4.5 mi/h 0.62-1.99 1.5E-07 7.2E-08 5.7E-08 4.3E-08 2.8E-08 2.5E-08 2.3E-08 2.OE-08 1.7E-08 1.4E-08 2.00-4-99 3.7E-08 1.6E-08 1.3E-08 9.5E-09 6.3E-09 5.6E-09 5.OE-09 4.4E-09 3.8E-09 3.2E-09 9.4E-09 5.OE-09 4.1E-09 3.2E-09 2.3E-09 2.OE-09 1.8E-09 1.5E-09 1.3E-09 1.1E-09 5.0-10.0

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 18 of 25 APPENDIX D Page 5 of 10 FIGURE 2 GROUP DISPLAY MENU

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 19 of 25 APPENDIX D Page 6 of 10 FIGURE 3 DOSE ASSESSMENT K.

-.. l 1. Ld SELECT FUINC. KEY OR TUR*h-*.0 C1E 1 i)OOSL ._

SQN - DOSE ASSESSMLN1 It, t DATE: 5 LL "

Q RECALCULATE TIME: I0 h) U VALUE UNITS QUALITY 1NPUITS:

16 MI/HR GOOD OY2307A EDS METDATA 45M 15MIN AVG WIND SPEED

  • .7i DEG OY2301A EDS METDATA 45M 15MIN AVG WIND DIRECTION (FROM) u 0 OY2319A EDS 15MIN STABILITY CLASS

- uCi/s 00 RAD025 ICS RECALCULATE TOTAL NOBLE GAS RELEASE RATE 2.95e.-01 uCils voori IODINE .001

  • TOTAL NOBLE GAS RELEASE RATE OUTPUT: HOURLY DOSE TEDE (Rem) THYROID CDE (Rem)

,,T-,- If,, fv 77 -7 06 7.47 0?

3MI DUUMMAI

'. 0.OOel-J

0. loc, ýU0 2 MILE:

5 MILE:

UE U I

.. O5... L... _ _2/,n~i,.

_

  • _~~~~- SIC Lt.L-L15 ,

RQIM/&,'CK .--

. CPU .,.A

.-..------ . ... 1 .

. .rWnDE w

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 20 of 25 APPENDIX D Page 7 of 10 FIGURE 4 SECONDARY MIMICS PAGE

EPIP-14 SQN RADIOLOGICAL CONT ROL RESPONSE Rev. 15 Page 21 of 25 APPENDIX D Page 8 of 10 FIGURE 5 MET-TOWER LINK PAGE m- METEl*[9. 4* 9, D-TA "1=1 Ma rGphs reds p10-SEP-1996 13:35:24 SELECT FUNC. KEY OR TURN-ON CODE METUATA > --. - Q MET-TOWER LINK INSTANTANEOUS 15 MIH AVG AIR TEMPERATURE: 73.27 DEGF 73.01 WINDSPEED: 4.0 MPH 4.0 WINDDIRECTION FROMt 31.4 DEGREES 26 Em RAINFALL LAST HOUR:0.0 INCHES LAST 15 MIN:0.0 INCHES AIR TEMPERATURE: 74.04 DEGF 73.73 10 METER DEWPOINT 5.0 MPH 4.0 (HOURLY AVG):73.32 DEGF WIND SPEED:

WINDDIRECTION FROM: 20.4 DEGREES 22 SOLOR RADIATION (HOURLY AVG): 0.0 LANGLEYS

/MIN AIR TEMPERATURE:74.97 DEGF 74.61 4.1 MPH 2.6 WIND SPEED:

12 WINDDIRECTION FROM: 43.5 DEGREES EMNOWI iTT026 R WK( 012Iwi n=1SEC LVL= PR MSAC CPU A MOI

.F6E

I SQN RADIOLOGICAL CONTROL RESPONSE APPENDIX D Page 9 of 10 EPIP-14 Rev. 15 Page 22 of 25 FIGURE 6 MET DATA FOR FRED CALC PAGE 1997 15:01:36 Page 1 of GROUP DISPLAY F -UK C rFR seconds A FOR FRED CALC Update rate 1.0 MET DAli QUAL VALUE UNITS DESCRIPTION PID CD00 ~3. DEGREES 46 METER VECTOR WIND DIR (15 MIN) oY2301A MPH 46 METER AVG W[ND SPEED (15 MIN)

OY2307A

  • ,00: INCHES RAINFALL IN THE LAST 15 MINUTES OY2312A STABILITY CLASS 10-46 MTR 15 MIN AVG OY2319A AM =-=- . . . . . . . . . . . . .

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 23 of 25 APPENDIX D Page 10 of 10 FIGURE 7 STABILITY/DELTA-T PAGE ain* Irends armGrphks 2s Zo ye's I~L~nt 1112 lo-SEP-1996 13:33:40

- 0 SELECT FUNC. KEY OR TURN-ON CODE MTDATA6 1 STABI LITY/DELTA-T 74.61 DEG F VERTICAL AIR TEMP DELTA-T 0.88 DEG F 10 METER AIR TEMP (15 MIN): 46-10 METERS (INSTANTANEOUS):

73.73 DEG F 1.69 DEG F 46 METER AIR TEMP (15 MIN): VERTICAL AIR TEMP DELTA-T 91-10 METERS (INSTANTANEOUS):

73.01 DEG F 91 METER AIR TEMP (15 MIN):

10 METER AIR TEMP STABILITY AIR TEMP 74.94 DEG F (INSTANTANEOUS) 46-10 MTR: D (INSTANTANEOUS):

STABILITY AIR TEMP 46 METER AIR TEMP (INSTANTANEOUS) 91-10 MTR: E 74.06 DEG F (INSTANTANEOUS):

STABILITY AIR TEMP 91 METER AIR TEMP (INSTANTANEOUS) 91-46 MTR: D 73.25 DEG F (INSTANTANEOUS):

STABILITY AIR TEMP D 46-10 MTR 15 MINUTE:

R TI N I WK=012/win=lSEC LVL=5 PRIM/BACKCPU A MODE 1

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 24 of 25 APPENDIX E Page 1 of 1 FITNESS FOR DUTY PROGRAM ADMINISTRATION CALL-IN SHEET Person Calling Date Give this message: "This is (caller's name) at Sequoyah Nuclear Plant. An emergency has been declared, or a REP drill is being conducted (as appropriate). Have you consumed any alcohol within the last five hours? Are you fit for duty? If you are fit for duty, please report to the RadCon Lab or Chemistry Lab and the duty RADCON or Chemistry Shift Supervisor immediately."

NAME TIME TIME ALCOHOL 5 ARE DUTY OFFICIAL CALLED NEEDED HRS. PRIOR YOU FIT COMMENTS TO TO REPORT? FOR REPORT (Y/N) DUTY?

+i i i 4 4 + I I I 4 i i 4 1 -t I I I I t I I I I t I I I I t I I I -t

SQN RADIOLOGICAL CONTROL RESPONSE EPIP-14 Rev. 15 Page 25 of 25 SOURCE NOTES REQUIREMENTS IMPLEMENTING SOURCE DOCUMENT STATEMENT STATEMENT NP Radiological Emergency Plan (NP-REP)

Paragraph 3.1.A SQ963213PER Revise EPIP-14 to indicate fitness for duty questions are required for call-ins.

Appendix D note SQ972164PER Require validation SQ972260PER after software or multiplication factor change.

Appendix D C.8 99-002929-000 Added manual calculation for Thyroid CDE to match ICS.

TENNESSEE VALLEY AUTHORITY SEQUOYAH NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE EPIP-17 Emergency Equipment and Supplies Revision 20 QUALITY RELATED PREPARED/PROOFREAD BY: W. P. Brooks RESPONSIBLE ORGANIZATION: Emergency Preparedness APPROVED BY John Casey EFFECTIVE DATE: 09-07-2000 Level Of Use: Reference REVISION DESCRIPTION: Intent Change. Added additional supplies to Appendix E to address issues from PER 00-005294-000; Clarify instructions to ensure TSC/OSC position books are scanned quarterly for uncontrolled or outdated material (not just out dated forms) Appendix H and I to address issue from PER 00-006599-000; improvements in hardware; and self assessment recommendations.

EPIP-17 EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 SQN Page 2 of 19 TABLE OF CONTENTS Section Title Page Table of C ontents .............................................................................. 2 1.0 P URP O S E .............................................................................................. 3 2.0 R EFERENC ES .................................................................................. 3 3.0 INSTR UCTIO NS ................................................................................ 3 3.1 G eneral Instructions ......................................................................... 3 3.2 D etailed Instructions .......................................................................... 3 3.3 Completion of Appendices ................................................................ 4 4.0 R EC O R D S ......................................................................................... 5 4.1 Q A R ecords ...................................................................................... 5 4.2 N on Q A Records ................................................................................ 5 APPENDICES Appendix A Emergency Equipment - Main Control Room (MCR) ....... 6 Appendix B Emergency Equipment - Communication Room ................. 7 Appendix C Emergency Equipment - RADCON Lab .............................. 8 Appendix D Site Medical Emergency Supplies ...................................... 9 Appendix E Self-Contained Breathing Apparatus ................................ 10 Appendix F Emergency Equipment - RADCON Vans ........................... 11 Appendix G Hospital Cabinet Inventory ............................................... 12 Appendix H Technical Support Center (TSC) ...................................... 13 Appendix I Operations Support Center (OSC) ................................... 14 Appendix J OSC Response Team Equipment ..................................... 15 Appendix K Emergency Equipment-480V Reactor MOV Board Room..... 16 Appendix L Decon Facility - Service Building ...................................... 17 Appendix M Responsibilities-Inventory and Maintenance .................... 18 SO URC E NOTES ...................................................................................... 19

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 3 of 19 1.0 PURPOSE This instruction is used to comply with the requirements of the Radiological Emergency Plan for periodic inspection and maintenance of equipment and supplies.

2.0 REFERENCES

A. CECC EPIP-9, Attachment J.

3.0 INSTRUCTIONS 3.1 General Instructions 3.1.1 The responsibility and frequency of inventories are specified in Appendix M.

For the purposes of these inventories, monthly is defined as once per calendar month, quarterly is defined as once per calendar quarter, and annual is defined as once per calendar year.

3.1.2 The individuals performing the inspection shall complete the appendices and the Emergency Preparedness Manager shall review the results as indicated and make arrangements to correct deficiencies.

3.1.3 List any deviations and the disposition on the appropriate Appendix Data Sheet. Deficient, outdated or missing items shall be replaced.

3.1.4 Special checks of certain material in the cabinets shall be performed. The following checks shall be made where applicable:

A. The protective clothing shall be checked for deterioration.

B. The smoke tubes and aspirator bulbs shall be checked for deterioration and that the tubes have not been broken or used.

C. Replace all flashlight batteries at the end of shelf-life with fresh batteries.

(Do not discard batteries. Return them to the tool room.)

D. Check to determine that flashlights are operable.

E. Rezero all emergency dosimeters to assure proper operation.

3.2 Detailed Instructions 3.2.1 The emergency equipment, listed in Appendices A and B, are stored in cabinets provided with a lock or plastic seal. This provides a means of controlling access or determining that the cabinet has not been opened. An inventory list of the equipment may be posted on the outside of the cabinet.

The two cabinets are located in the Main Control Room corridor, and Communications Room.

3.2.2 Each cabinet and storage location, including the medical treatment area, shall be inventoried and required equipment inspected and checked for operation and/or condition. Equipment in certain cabinets is separated into Table A and Table B. Table A is a list of all non-perishable items stored in a small metal box equipped with a security seal within the cabinet itself. These items will be inventoried annually (preferably in January) and whenever a security seal has been found to be violated. Those items listed in Table B of these attachments are inventoried on a quarterly basis.

3.2.3 The radiation monitoring instruments, which are in normal plant use, are located in the RADCON laboratory as listed in Appendix C.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 4 of 19 3.2.4 The Site Medical Emergency Supplies listed in Appendix D are located in the site ambulance or the site medical station.

3.2.5 All self-contained breathing units in service on Appendix E shall be inventoried and inspected monthly by Fire Protection.

3.2.6 The emergency equipment, referenced in Appendix F is located in the environmental monitoring emergency vans. In the event of a radiological emergency that requires the emergency vans to be used, a RADCON technician will obtain the additional equipment listed in CECC-EPIP-9, Attachment J. This equipment will be transported to the vans.

3.2.7 The emergency room supplies furnished by TVA for use of the agreement hospital(s) in case of injury to personnel involving radioactive materials are listed in Appendix G.

3.2.8 References and supplies listed in Appendix H are stored in the Technical Support Center for use during an emergency and Appendix I for the Operations Support Center. TSC/OSC position notebooks shall be scanned during the quarterly inventory for uncontrolled or outdated materials; not just outdated forms. Additionally, position seating/working areas should be scanned for uncontrolled or outdated materials.

3.2.9 Protective clothing for use by the OSC response teams is located in the Operations Support Center storage room and is listed in Appendix J.

3.2.10 Protective clothing for use in contamination controls from affected plant areas in the Control Building are listed in Appendix K and is located in the 480 V Reactor MOV Board Room, Elevation 734.

3.2.11 Supplies for decontamination of personnel are stored in the EI.690' Decon.

Room near the RadCon lab and are listed in Appendix L.

3.3 Completion of Appendices 3.3.1 If the particular items are present and in sufficient quantities and, when applicable, in good working condition, then check the "Yes" column.

3.3.2 If a deficiency is noted, then check the "No" column and replace deficient items. All deficiencies must be corrected as soon as possible. If circumstances do not allow deficiencies to be corrected, then the appropriate supervisor shall be notified.

3.3.3 Under the "Remarks" column, explain the corrective actions taken.

3.3.4 All comments in the "Remarks" column should be detailed enough to leave no doubt as to the actions taken. Comments to the effect - "batteries missing" will not suffice. A simple check in the "No" column will represent that a deficiency exists. Such comments do not allow a person to determine what, if any, action has been taken. Comments should read for example: "Batteries missing., replaced on March 5, 2000".

EPIP-1 7 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 5 of 19 4.0 RECORDS 4.1 QA Records None 4.2 Non-QA Records The Appendices/Checklists in this Instruction are NON-QA documents and will be retained by the SQN Emergency Planning (EP) Manager for at least two years.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 6 of 19 APPENDIX A MAIN CONTROL ROOM CORRIDOR CABINET - CONTROL BUILDING TABLE A Quantity Description Yes No Remarks Security seal intact: ................................................ .......

NOTE: Table A will be inventoried annually (preferably in January) and whenever a security seal has been found to be violated.

12 pr. Rubber overshoes - Various sizes ...................... -

6 pr. Canvas gloves ...................................................- __

12 pr. Rubber gloves- Various sizes .............................. _

6 Ho o d s .....................................................................

2 P e n cils ....................................................................

2 Clipboards with paper .............................................

2 Boxes sm oke tubes ................................................

2 A spirator bulbs ........................................................

1 Lo g B oo k ................................................................

4 rolls Duct tape and/or masking tape ...............................

Security seal replaced ......................................................... ...

TABLE B Quantity Description Yes No Remarks 12 Pairs of paper overalls - Various sizes ........

2 Ha rd hats .................................................................

2 F la sh lig hts ..............................................................

12 Spare flashlight batteries Expires: _ _ ...........

2 Spare flashlight bulbs ............................................. -_

1 F irst-a id kit ..............................................................- _

12 Face G oggles .........................................................

1 Radiation Survey Meter ..........................................

Cabinet Relocked or Resealed ............................................ . . _

Inspection performed by:

RADCON Representative Date Review and Approval:

Emergency Preparedness Manager Date EP Mana-qershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 7 of 19 APPENDIX B COMMUNICATIONS ROOM - CONTROL BUILDING TABLE A Quantity Description Yes No Remarks Security seal intact: ...................................................................... w NOTE: Table A will be inventoried annually (preferably in January) and whenever a security seal has been found to be violated.

6 Pairs of rubber overshoes ......................................

6 Pairs canvas gloves ........................................... _

6 Pairs rubber gloves ............................................. -_.

6 Hoods .....................................................................

2 Pencils ....................................................................

2 Clipboards with paper .............................................

2 Boxes sm oke tubes ................................................

2 Aspirator bulbs ..................................................... -.

1 Log Book ........................................................... ....

Security seal replaced ................................................................

TABLE B Quantity Description Yes No Remarks 6 Pairs of coveralls - various sizes .............................

2 Hardhats .................................................................

2 Flashlights ..............................................................

12 Spare flashlight batteries Expires: ...........

2 Spare flashlight bulbs .............................................

1 First-aid kit ..............................................................

Cabinet Relocked or Resealed ............................................

Inspection performed by:

RADCON Representative Date Review and Approval:

Emergency Preparedness Manager Date EP Mana-gershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 8 of 19 APPENDIX C RADIOLOGICAL CONTROL LABORATORY - SERVICE BUILDING Quantity Description Yes No Remarks 1 Alpha Survey Meter (500,000 cpm) .............................

1 Neutron dose rate survey meter

(.025 eV - 10 MeV/5,000 mR/hr) .................................

2 High Range Survey Instrument (1,000 R/hr with extendible probe) ..............................

6 ION Chamber Survey Meter (50 R/h) ..........................

1 ION Chamber Survey Meter (20,000 R/h) .........

5 High volume Air Samplers (and support equipment)..._

10 Frisker Type Survey Meters (0-50,000 cpm) ............... _

5 Low-volume air samplers (and support equipment) ..... _

1 Portable Mini-S caler ....................................................

5 C a lcu lato rs ..................................................................

2 Cal/Response Ck Sources ..........................................

5 Noble Gas Sampling Syringes .....................................

10 Silver Zeolite Cartridges ..............................................

5 Marinelli B eakers .........................................................

1 Shielded Detector Pig ..................................................

Inspection performed by:

RADCON Representative Date __

Review and Approval:

Emergency Preparedness Manager Date EP Mana-qershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 9 of 19 APPENDIX D Page 1 of 1 SITE MEDICAL EMERGENCY SUPPLIES Check applicable column either Ambulance or Medical Station (only one needs to be checked, not both.)

EQUIPMENT AMBULANCE MEDICAL YES NO REMARKS STATION Blood Pressure Apparatuses I- Li Li __

Marion Ventilators with Oxygen 0 0 0 - __

Oxygen - Large Tanks Li [] Li __

I.V. Setup

- fluids El El Ml El

-tubing El E] l El __

- needles El [E El El Suctions - Portable 0 [] E fL __ _

Anaphylaxis Kits 0 0 *] 0_

Immobilizing Equipment AMBULANCE MEDICAL YES NO STATION

- Stokes Baskets Li [] _ ____

- Scoop Stretchers El El El El 3ack Boards El El El __

-Hare Splints El Fl El E __

-Air Splints El El El E __

- Splints - arm, finger, and leg Dl El El 0_

- Extrication Collars El E] El El Trauma Kits Containing Note: Trauma kits are located Li __

Burn Sheets, TriangularBandages,Air in Auxiliary Building on Splints, Bite Sticks, Dressings,Pocket elevation 690 & 734 near Masks, Gloves, Scissors, Adhesive elevator Tape, IrrigatingSolution, Cold Packs, Flashlight Sand Bags Li Disposable Gowns EQ E1 E_

Blankets El E1 0 _

Stretcher Straps E-n L 0 __

Mast Trousers Ei E] El E_

Cleaning Solution AMBULANCE MEDICAL YES NO STATION

- Betadine Solution [ [ E J _ _

- Hydrogen Peroxide l El El El _

- Brushes El El El El--

Inspection Performed By: Date Review and Approval:

Emergency Preparedness Manager Date EP Manacjershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 10 of 19 APPENDIX E Page 1 of 1 SELF-CONTAINED BREATHING APPARATUS Quantity Description Yes No Remarks RELAY ROOM OUTSIDE TECHNICAL SUPPORT CENTER (EL 732) 12 Self-contained breathing apparatus ....................................

12 Additional air cylinders ........................................................

2 Sm all MSA face pieces .............................................

2 Large M SA face pieces ......................................................

SERVICE BUILDING EL 690 (PASF Units) 8 4

Dual Purpose self-contained breathing apparatus ..............

Dual Purpose Airline Hoses ................................................

I 3 Small MSA face pieces .......................................................

3 Large MSA face pieces ......................................................

SERVICE BUILDING EL 690 (RADCON AND RADCHEM LABS) 16 Self-contained breathing apparatus .................................... I SERVICE BUILDING (EL. 706) FIRE EQUIPMENT CAGE 6 Self-contained breathing apparatus ....................................

12 A dditional cylinders .............................................................

Inspection performed by: I Fire Protection Representative Date Review and Approval:

Emergency Preparedness Manager Date EP Managershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-17 EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 SQN Page 11 of 19 APPENDIX F EMERGENCY EQUIPMENT ENVIROMENTAL MONITORING EMERGENCY VANS (SEE CECC-EPIP-9, ATTACHMENT J).

EP Mana-gershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 12 of 19 APPENDIX G HOSPITAL CABINET INVENTORY EII North Park I-IErlanger

[SATI Quantity I Description Remarks Protective Clothin g1 10 pair Shoe covers 10 pkg Dress out packages (coveralls, booties, gloves) 3 Surgical gowns 2 boxes Surgical gloves 4 rolls I Surgical tape fordressout - 2 inch Facility Preparation ______________

Iset Floor coverings (hospital specific) 1 roll Heavy duty paper (3 foot wide) 2 rolls 2 inch duct tape 1 roll Radiation Warning symbol tape (2 inch) 2 Step off pads 8 Radiological barrier posting signs 1 Spool Radiological barrier rope or ribbon 5 Traffic cones 10 Large rad waste plastic bags (trash can size) 10 Medium rad waste plastic bags (x-ray cassette size) 2 copies Hospital specific booklet (1 at desk, 1 in cabinet) Last Update:

1 Radioactive material label tape Decontamination Supplies 1 Decontamination table, backboard and bottles (min. total capacity of 10 gallons) 1 Flexible funnel with drain hose - optional 1 Decontamination media /soap product 1 NCRP # 65 Reference Handbook 12 Cotton swabs 20 Zip lock bags for sample collection 10 Labels for sample bags 2 Scissors 1 Wall poster with decontamination steps Health Physics Supplies (Serial # and cal due) 1 Bicron ISM (RSO-5 or 50) 2 Bicron Surveyor 50 1 Wound probe with cable 10 TLDs 10 Electronic dosimeters and tray 200 Smears 12 Radioactive Material tags 1 Masslin mop and 20 cloths Inspection Performed By: Date Review and Approval:

Emergency Preparedness Manager ____________

Date EP Mana-gershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-1 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 13 of 19 APPENDIX H TECHNICAL SUPPORT CENTER Description Yes No Remarks Qtv AssortEed Dryboard Supplies (Erasers, markers, etc.) ................................-..

Assort ad Desktop Supplies (Stapler, Tape, Logbooks) .............................. _

Assort( ed Office Supplies (Pen, Pencils, Staples, Etc.) ............................... __

1 each TSC Position Notebooks ..................................................................... seating areas.)

(Scan/Check for uncontrolled/out-of-date materials in Position notebooks &

1 Spare Roll of thermal Paper for Tracking Board ............................

2 A SM E Steam Tables .....................................................................

4 Communications Head Sets .................................................... -

4 Sequoyah Phone Directories (latest edition) ............................... .

3 Chattanooga Phone Directories (latest edition) .................

2 TVA Phone Directories (latest edition) ........................................ .

5 Electronic Display Projectors .........................................................

Verify wall maps are latest revision (see CECC EPIP-9) 2 Mile Map ................... Latest Rev. .....................................

10 Mile Evac Map ........ Latest Rev. .....................................

50 Mile Sample Map .... Latest Rev. - (2 copies) ....................

50 Mile Map ................. Latest Rev. (1 0 copy) .......................

Verify presence only (DCU controls contents)

REP (Radiological Emergency Plan) (4 copies) .............................. .

REND (Radiological Emergency Notification Directory) (2 copies) ....

Central Emergency Control Center EPIP (CECC EPIP) (2 Copies) ...

S Q N E P IP (4 copies) .........................................................................

Severe Accident Management Guidance (SAMG) (4 copies) ............

Updated SQN FSAR ......................................... ..........-.

Unit 1 Technical Specifications (2 sets) .............................................

Unit 2 Technical Specifications (2 sets) .............................................

Site Health and Safety Manual ....................................................... .

State of Tennessee Multijurisdictional REP Response Plan ..............

INPO Emergency Resources Manual .................................................

System Operating Manual/System Operating Instructions (SO/SOl).

Annunciator Response Manuals (AR) ................................................

P eriodic Instructions (P I)....................................................................

Abnormal Operating Procedures (AOP) (2 Sets) ...............................

Technical Instructions (TI) .........................................

General Operating Instructions (GO) .................................................

SQN Offsite Dose Calculation Manual (ODCM) ................-..

SQN Process Control Program (PCP) ............................................ .

Radiological Control Instructions (RCI) ...............................................

Radwaste Handling/Shipping Index (RHSI) ........................................

Functional Restoration Guidelines (2 sets) ........................................

Emergency Instructions (2 sets) .........................................................

Emergency Abnormal Procedures (EAPs) (2 sets) ............................

Emergency Contingency Actions (2 sets) ..........................................

Users Manual - Meteorological Data Print Program (2 copies) ...........

Users Manual - FRED (2 copies) ........................................................

Users Manual - Meteorological Data Display ..... ............

Users Manual - CECC Information System ........................................

Users Manual - ICS ............................................................................

Inspection Performed By: Date Review and Approval:

Emergency Preparedness Manager Date EP Managiershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 14 of 19 APPENDIX I OPERATIONS SUPPORT CENTER (OSC)

Quantity Description Yes No Remarks Assorted Desktop Supplies (stapler, tape, logbook) ............

Assorted Office Supplies (pens, pencils) .............................................

Assorted Dryboard Supplies (eraser, markers, etc.) .............

2 Spare Roll of thermal Paper for Tracking Board ...................

1 S Q N E P IP s ..........................................................................

1 each OSC Position Notebooks ......................................................

(Scan/Check for uncontrolled/out-of-date materials in Position Notebooks & seating areas.)

2 SQN Telephone Book (latest edition) ................

2 TVA Telephone Book (latest edition) ....................................

1 User Manual - IC S ................................................................

4 Communication Headsets ....................................................

1 Polaroid Camera W/Film Expires_ ............................

2 Team Tracking Status Boards ..............................................

1 Ops Tracking Status Boards .................................................

1 RadCon/Chem Tracking Status Boards ................................

12 Spare flashlight batteries Expires. ............................

6 Spare Pager Batteries Expires ................................

2 Electronic Display Projectors ................................................

Plant Drawings (verify existence only DCU controls listing) .............. _ _

Verify wall maps are latest revision (see CECC EPIP-9 for latest map revision levels) 2 Mile Map Latest Rev. ...............

10 Mile Evac Sector Map Latest Rev.

10 Mile Sampling Point Map Latest Rev. ...............

Tool Room Tool Kits: ...............................................

Note: Tool Room tool kits are inventoried in accordance with 0-PI-REM-000.001Q Mechanical tool kit #1 Mechanical tool kit #2 Electrical tool kit #3 Mechanical tool kit #4 Mechanical tool kit #5 Mechanical tool kit #6 Electrical tool kit #7 Note: Additional Communications Equipment is checked under 0-PI-REM-244-001.0 I Inspection Performed By: Date Review and Approval:

Emergency Preparedness Manager Date EP Manacqershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-1 7 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 15 of 19 APPENDIX J OSC RESPONSE TEAM EQUIPMENT CAFETERIA OSC EQUIPMENT STORAGE ROOM Quantity Description Yes No Remarks 40 pr. Cotton liners ...............................................................

40 pr. Rubber gloves - Various sizes ...............................................

40 pr. P lastic booties ........................................................................

40 pr. Rubber overshoes - Various sizes .........................................

30 pr. Coveralls - Various sizes .......................

30 Surgeon caps ...........................................................

30 Hoods...................................

4 rolls Duct Tape and/or Masking Tape ............................................

2 Ha rd hats ................................................................................

6 pr. C anvas gloves .......................................................................

2 S pare flashlight bulbs ............................................................

2000 doses KI (Expires j (#Pkgs * #Tablets/pkg = #doses) ...... I Door Relocked ....................................................................... .

Inspection performed by:

RADCON Representative Date Review and Approval:

Emergency Preparedness Manager Date EP Mana er shall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-1 7 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 16 of 19 APPENDIX K 480V REACTOR BOARD ROOM AUXILIARY BUILDING (EL. 734)

Quantity Description ................................................................. Yes No Rem arks 40 pr. C otton liners ...............................................................-

40 pr. Rubber gloves - Various sizes .................. . _

40 pr. Plastic booties ............................................................-

40 pr. Rubber overshoes - Various sizes ................. .. _ _

30 pr. Paper coveralls ...................................................... _

30 S urgeon caps .............................................................

1 Box of vinyl gloves ................................................ ...-

4 rolls Duct Tape and/or Masking Tape ...........................- ...

6 pr. C anvas gloves ...........................................................

2 Fla shlig hts ..................................................................

2 Spare flashlight bulbs ................................................

12 Spare flashlight batteries Expires_ .................

Cabinet Relocked or Resealed ............................................

Inspection performed by:

RADCON Representative Date Review and Approval:

Emergency Preparedness Manager Date EP Managershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 17 of 19 APPENDIX L EL. 690' DECONTAMINATION ROOM MIN SUGGESTED QUANITY ITEM QUANITY QUANITY ON HAND REMARKS Disposable Gloves 1 box 2 boxes Gauze Pads 1 box 2 boxes Cotton Swabs 1 pkg 1 pkg Saline Solution 1 bottle 2 bottles Surgical Brushes 1 each 12 each Shampoo 1 bottle 2 bottles Soap 2 bars 5 bars Laundry detergent none I box Soap (liquid abrasive) none 1 bottle Mechanic's Hand Cleaner none 2 can Shaving Cream 1 can 1can Razors 2 each 5 each Paper Bath Towels none 1 box Towels 5 each 25 each Scissors 1 pair 1 pair Petri Dishes 3 each 5 each Duct Tape none 2 rolls Paper Coveralls 5 pair 10 pair Tennis Shoes (Sizes 7- none one pair half sizes are OK

12) each Inspection Performed By:

RADCON Representative: Date:

Reviewed By:

RADCON Shift Supervisor: Date:

EP Manager: Date:

EP Managershall retain the completed form as a Non-QA Record for at least 2 years.

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 18 of 19 APPENDIX M INVENTORY AND MAINTENANCE RESPONSIBILITIES Appendix Frequency Responsible RADCON A. Main Control Room - Corridor Cabinet Table A Annually Table B Quarterly B. Communications Room RADCON Control Building Annually Table A Table B Quarterly C. Radiological Control Lab Monthly RADCON Quarterly Fire Protection/Medical D. Medical Emergency Supplies E. Self-contained Respiratory Fire Protection Equipment Monthly Quarterly RADCON F. Emergency Vans Corporate EP G. Hospital Emergency Room Cabinet Quarterly H. Technical Support Center Cabinets, EP Manager References & Supplies Quarterly I. Operations Support Center Storage, EP Manager References & Supplies Quarterly J. OSC Response Team Storage, RADCON Service Bldg. EL. 706' Quarterly K. 480V RX MOV Board Room RADCON EL. 734' Quarterly L. Decon. Facility, Service Building EL. 690' Monthly RADCON

EPIP-17 SQN EMERGENCY EQUIPMENT AND SUPPLIES Revision 20 Page 19 of 19 SOURCE NOTES REQUIREMENTS IMPLEMENTING SOURCE DOCUMENT STATEMENT STATEMENT H-10 NUREG 0654 "Emergency Equipment Inspections" Appendix E, Section E 10 CFR 50 Section 8.0 NP REP "Emergency Response Facilities, Equipment, and Supplies" NUREG 0696 "Functional Criteria For Emergency Response Facilities"