4 to Procedure No. EL-4.2, Operational Support Center Activation, to Palisades Nuclear Plant Emergency Implementing Procedure
ML003745269
Person / Time
Site: Palisades 
(DPR-020)
Issue date: 08/18/2000
From: Brott N, Watkins D
Consumers Energy
To: Mcknight J
Document Control Desk, Office of Nuclear Security and Incident Response
References
-RFPFR El-4.2, Revision 14
Download: ML003745269 (30)


Text

Date Entered: Aug 18, 2000 TO:

USNRC/WASHINGTON JMCKNIGHT Copy Number:

145 TRANSMITAL NUMBER:

161109 PROCEDURE NUMBER: EI-4.2 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION TRANSMITTAL: LISTED BELOW ARE NEW/REVISED PROCEDURES WHICH MUST BE IMMEDIATELY INSERTED INTO OR DISCARDED FROM YOUR PROCEDURE MANUAL.

Action Required Section or Description REMOVE AND DESTROY EI-4.2, R/14, ENTIRE PROCEDURE REPLACE WITH EI-4.2, R/14, ENTIRE PROCEDURE EDITORIAL SIGN, DATE, AND RETURN THE ACKNOWLEDGEMENT FORM WITHIN 10 DAYS TO THE PALISADES PLANT DOCUMENT CONTROL SIGNATURE OR INITIALS DATE

Procedure No EI-4.2 Revision 14 Issued Date 8/18/00 PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION Procedure Sponsor Date NKBrott

/ 4/2/98 Technical Reviewer Date DAWatkins t 4/6/98 User Reviewer Date

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page i TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION Table of Contents 1.0 PERSONNEL RESPONSIBILITY..............................

1 1.1 OPERATIONAL SUPPORT CENTER (OSC) DIRECTOR 1

2.0 PURPOSE.............................................

1

3.0 REFERENCES

1 3.1 SOURCE DOCUMENTS...........................

1 3.2 REFERENCE DOCUMENTS..........................

2 4.0 INITIAL CONDITIONS ANDIOR REQUIREMENTS................

2 5.0 PBRO EDUJRE..........................................

3 5.1 FACILITY DESCRIPTION 3

5.1.1 Facility Intent.......................

3 5.1.2 Physical Location 3

5.1.3 Organization............................

3 5.1.4 Equipment..............................

3 5.2 ACTIVATION..................................

4 5.2.1 Assembly and Accountability................

4 5.2.2 Physical Arrangement.....................

4

PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page ii TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION Table of Contents OSC PERSONNEL............................

Maintenance Supervisor...........

5.3.1 5.3.2 5.3.3 Health Physics Supervisor.............

5.3.4 Chemistry Supervisor.........

5.3.5 OSC/TSC Communicators (Maintenance and Health Physics).....................

5.3.6 Technical Information Facilitator (TIF......

5.3.7 5.3.8 5.3.9 5.3.10 5.3.11 5.3.12 5.3.13 Radio Communicator..........

Emergency Maintenance Teams.

Chemistry Technicians........

Health Physics Technicians.....

Dosimetry Support..........

Health Physics Support.......

Auxiliary Operator (AOl.......

.5 5

6 6

8 8

9 10 10 11 11 12 12 13 EVACUATION/RELOCATION 14 ATTACHMENTS AND RECORDS............

6.1 6.2 ATTACHMENTS.................

RECORDS.....................

14 14 15 ATTACHMENTS,,,,,,,,,

"Operational "Operational "Operational "Operational "Operational "Operational "Operational "Operational Support Support Support Support Support Support Support Support Center Activation List" Center Floor Plan" Center Organizational Chart" Center Dosimetry Log Sheet" Center Instrument Control Log Sheet" Center Request Form" Center Response Team Form" Center Response Team Checklist" "Sequence of Events Form" 0, "Operational Support Center Priority Form" 5.3 QI 5.4 6.0

PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page 1 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 1.0 PERSONNEL RESPONSIBILITY 1.1 OPERATIONAL SUPPORT CENTER (OSC) DIRECTOR The OSC Director is responsible for overall activation and direction of the OSC in support of the Technical Support Center (TSC), Engineering and Maintenance Support Group, Health Physics (HP) Support Group, and Operational Support Group Chemistry Team.

2.0 PURPOSE To provide guidance for efficient activation and operation of the OSC to adequately support the TSC in an emergency.

3.0 REFERENCES

3.1 SOURCE DOCUMENTS 3.1.1 NUREG 0654, Section H, "Emergency Facilities and Equipment" 3.1.2 Site Emergency Plan, Section 7, "Emergency Facilities and Equipment" USERALEBI INFORMATION USE PROCEDURE The activities covered by this procedure may be performed from memory.

I I

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 2 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION REFERENCE DOCUMENTS Palisades Administrative Procedure 5.01, "Processing Work Requests/Work Orders" El-12.1, "Personnel Accountability" EI-8, "Onsite Radiological Monitoring" El-14, "Medical Care/Treatment of EI-9, "Offsite Radiological EI-7.0, "Emergency Post Accident El-1 2.3, "Search and Rescue Team El-1 6.1, "Maintenance of Emergency EI-2.1, "Site Emergency Director" EI-3, "Communications and 3.2.11 Radiological Work Practice 316, "Electronic Dosimetry Operations with MIS Down" 4.0 INITIAL CONDITIONS AND/OR REQUIREMENTS The OSC shall be activated at the Alert or higher emergency classification. The OSC may be activated before this time at the option of the Site Emergency Director (SED).

3.2 I 3.2.1 3.2.2 Emergency Implementing Procedure 3.2.3 Emergency Implementing Procedure 3.2.4 Emergency Implementing Procedure Contaminated, Injured Personnel" 3.2.5 Emergency Implementing Procedure Monitoring" 3.2.6 Emergency Implementing Procedure Sampling Decision Process" 3.2.7 Emergency Implementing Procedure Responsibilities" 3.2.8 Emergency Implementing Procedure Equipment" 3.2.9 Emergency Implementing Procedure 3.2.10 Emergency Implementing Procedure Notifications"

PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page 3 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.0 PROCEDURE 5.1 FACILITY DESCRIPTION 5.1.1 Facility Intent The OSC provides a control point for onsite and initial offsite (prior to EOF activation) support involving Chemistry, HP, Maintenance and Operations.

Reference Emergency Implementing Procedure EI-3, "Communications and Notifications," Attachment 5, "Emergency Response Facilities Phone List," for the complete phone list.

5.1.2 Physical Location The OSC encompasses Assembly Area V (located in the Service Building Lunchroom) and Assembly Area VI (located in the Main Locker Room across from lunchroom). Attachment 2 provides a floor plan of the OSC.

5.1.3 Organization The OSC consists of personnel outlined in Section 5.3 of this procedure. provides a block diagram of OSC organization. Auxiliary Operators are not included on Attachment 3; see Section 5.3.13 for specifics.

5.1.4 Equipment OSC emergency equipment shall be as described in Emergency Implementing Procedure El-1 6.1, "Maintenance of Emergency Equipment." Additional equipment may be obtained as habitability of an area is ascertained.

USER ALERT INFORMATION USE PROCEDURE The activities covered by this procedure may be performed from memory.

I

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 4 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.2 ACTIVATION 5.2.1 Assembly and Accountability

a.

Upon sounding of the emergency siren, or at the direction of the SED, personnel assigned to Assembly Areas V and VI shall proceed to their assembly area and report to their Assembly Area Leader.

b.

Initial habitability of the OSC should be verified upon assembly.

If the area dose rate exceeds 100 mrem/hr or air concentration is 40 DACs, immediately notify the OSC Director.

c.

Personnel accountability shall be performed per Emergency Implementing Procedure E-112.1, "Personnel Accountability."

5.2.2 Physical Arrangement

a.

Establish personnel zones per the layout on Attachment 2 of this procedure, or as directed by the OSC Director.

b.

Obtain OSC emergency equipment from the Fan Room located north of the OSC. Distribute equipment and post status boards per the layout in Attachment 2 of this procedure.

c.

Establish a frisking station for equipment and personnel monitoring in a low background area, < 300 cpm, as close to the entrance of the OSC as possible.

d.

Establish a dosimetry control point near the entrance to the OSC.

An equipment staging area should be set up in the OSC facility.

e.

Establish a station for sample analysis in accordance with Emergency Implementing Procedure EI-8, "Onsite Radiological SI Monitoring," Step 5.2.4a, "OSC Activation."

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 5 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3 OSC PERSONNEL 5.3.1 OSC Director The OSC Director shall:

a.

Ensure accountability is completed within 30 minutes.

b.

Ensure adequate personnel are available for performance of OSC functions.

c.

Direct physical activation and layout of the OSC using Attachments 1 and 2 of this procedure as guidance.

d.

Apprise OSC personnel of Plant conditions and emergency classification throughout the emergency.

e.

Coordinate efficient and orderly function of the OSC.

f.

Coordinate priorities for HP coverage of maintenance activities with the Health Physics Supervisor(s).

g.

Ensure all mandatory actions and Plant priorities are communicated to the OSC staff.

h.

Assume responsibility for Auxiliary Operators (AOs) after the OSC is declared operational and the Shift Supervisor has released them to the OSC.

Shall ensure prejob briefings are conducted using Attachment 8, "Operational Support Center Response Team Checklist," for all teams leaving the OSC except HP teams that use Emergency Implementing Procedures El-8, "Onsite Radiological Monitoring,"

and El-9, "Offsite Radiological Monitoring."

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 6 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.2 Maintenance Supervisor The Maintenance staff may include an I&C Supervisor, Electrical Maintenance Supervisor, and a Mechanical Maintenance Supervisor.

Maintenance Supervisors should:

a.

Assist the OSC Director in accountability and activation of the OSC.

b.

Organize and direct the appropriate emergency maintenance teams as per the TSC and OSC Director.

c.

Ensure that all emergency maintenance teams report to the HP Supervisor for a prejob briefing.

d.

If needed, direct I&C Technicians to adjust master PA volume potentiometer in the telephone room (3rd floor Administration Building) with SED approval.

5.3.3 Health Physics Supervisor The HP Supervisor shall:

a.

Assist the OSC Director in accountability, activation, and subsequent functions of the OSC, as needed.

b.

Ensure HP prejob briefings and debriefing of returning work teams are conducted.

NOTE:

Quick dispatch of Search and Rescue Teams is vital in case missing persons need medical assistance.

c.

Organize and direct Search and Rescue teams in accordance with Emergency Implementing Procedure El-12.3, "Search and Rescue Team Responsibilities," as directed by the TSC.

d.

Organize and direct onsite monitoring teams in accordance with Emergency Implementing Procedure EI-8, "Onsite Radiological Monitoring," as directed by the TSC.

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 7 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION

e.

Organize and direct first aid teams in accordance with Emergency Implementing Procedure El-1 4, "Medical Care/Treatment of Contaminated, Injured Personnel." If offsite medical assistance is needed in an Alert or above, request through the TSC HP Support Group that the TSC Communicator make the appropriate calls.

f.

Organize and direct offsite monitoring teams, prior to EOF activation in accordance with Emergency Implementing Procedure EI-9, "Offsite Radiological Monitoring," as directed by the TSC. Upon EOF activation, establish EOF radio contact with the teams and ensure the following information is relayed to HP Support Group (as applicable):

1.

Number of teams.

2.

Team members, identified.

3.

Team(s) location.

4.

Pertinent surveys, results.

5.

Pertinent samples taken, results.

6.

Team(s) dose records.

7.

Meteorological data.

g.

Supervise dosimetry and equipment control.

h.

Perform Dose Limit Assessments (reference Emergency Implementing Procedure EI-2.1, "Site Emergency Director").

i.

Provide HP support for Chemistry/Maintenance/Operations teams.

j.

Ensure HP status boards are updated.

k.

Direct the Security teams on radiologically acceptable routes onsite.

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 8 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.4 Chemistry Supervisor The Chemistry Supervisor shall:

a.

Assist the OSC Director in accountability, activation, and subsequent functions of the OSC, as needed.

b.

Organize and direct the post accident sampling and analysis teams in accordance with Emergency Implementing Procedure EI-7, "Emergency Post Accident Sampling Decision Process," as directed by the TSC.

SI

c.

Organize and direct onsite analysis of samples, coordinating with the HP Supervisor in prioritizing sample counting.

5.3.5 OSC/TSC Communicators (Maintenance and Health Physics)

The Communicators shall:

a.

Setup and test communications using telephones/sound-powered phone contained in the OSC Emergency Kit.

b.

Establish communication with TSC counterpart.

c.

Document incoming requests on Attachment 6, "Operational Support Center Request Form," as appropriate.

d.

The OSC/TSC Maintenance Communicator should:

1.

Maintain the OSC status board which lists emergency priorities and equipment out of service.

2.

Periodically validate that the emergency priorities listed in the TSC and OSC are in agreement.

3.

Advise TSC Eng/Maintenance of available maintenance resources from the OSC Resources status board.

K)

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 9 of 16 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION

e.

The OSC/TSC Health Physics Communicator should:

1.

Obtain meteorological data from the TSC.

2.

Maintain offsite and onsite team information.

3.

Advise TSC HP of changes made in the OSC Response Team status board.

4.

Advise TSC HP of available OSC HP resources from the OSC Resources status board.

Technical Information Facilitator (TIF)

a.

Maintain the Sequence of Events board for the Operational Support Center (OSC), and use Attachment 9, "Sequence of Events Form,"

as needed.

b.

Remain on the dedicated group line until relieved by another qualified individual.

c.

Assist the OSC Director in maintaining communications with the TSC, Control Room, and EOF.

d.

Assist the OSC Director with dispatching AOs from the OSC.

e.

Discuss OSC priorities with the other facility TIFs and notify OSC leadership of impending conflicts.

f.

Notify OSC leadership of important and/or emergency developments.

5.3.6

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 10 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.7 Radio Communicator The Radio Communicator shall:

a.

Setup and test radio communications, using hand-held battery powered radios and mobile radios contained in the OSC Emergency Kit.

b.

Relay messages to and from the onsite and offsite monitoring teams via hand-held/mobile radio, or other available means. Upon EOF activation, assist the EOF Radio Communicator in turnover of the offsite monitoring teams to the EOF HP Support Team.

c.

Ensure efficient and timely information flow and documentation of messages by documenting incoming information from onsite/offsite teams for OSC HP Supervisor review and disposition.

d.

Ensure the 10-mile EPZ map is updated with radiological data from Offsite Monitoring Teams.

5.3.8 Emergency Maintenance Teams Emergency Maintenance Teams should:

a.

Attend prejob briefing(s) prior to performing emergency maintenance.

b.

Perform permanent or temporary emergency repairs as directed by the OSC Maintenance Supervisors, per Palisades Administrative Procedure 5.01, "Processing Work Request/Work Orders."

c.

Report back to HP Supervisor on return to OSC for debriefing.

d.

Follow guidelines of Attachment 8, "Operational Support Center Response Team Checklist," for implementation and task completion.

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 11 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.9 Chemistry Technicians Chemistry Technicians shall:

a.

Assist in initial physical arrangement of the OSC facility per Section 5.2.2 of this procedure.

b.

Perform post accident sampling and analysis in accordance with Emergency Implementing Procedure EI-7, "Emergency Post Accident Sampling Decision Process."

c.

Perform onsite analysis of samples.

5.3.10 Health Physics Technicians HP Technicians shall:

a.

Transport available survey instruments, air samplers, and other appropriate equipment to the OSC.

b.

Assist in physical activation and equipment setup of the OSC per.

c.

Perform onsite monitoring in accordance with Emergency Implementing Procedure El-8, "Onsite Radiological Monitoring."

d.

Perform offsite monitoring in accordance with Emergency Implementing Procedure EI-9, "Offsite Radiological Monitoring."

e.

Perform search and rescue, first aid in accordance with Emergency Implementing Procedures El-1 2.3, "Search and Rescue Team Responsibilities," and EI-14, "Medical Care/Treatment of Contaminated, Injured Personnel."

f.

Upon return to the OSC, ensure that status boards, OSC-4, "Monitoring Team Data," and OSC-6, "Onsite Monitoring Board (Habitability Areas)," are updated.

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 12 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.11 Dosimetry Support Dosimetry Support personnel shall:

a.

Set up and bring equipment designated in Sections 2c and g,, of this procedure. Controlled procedures and copies of appropriate attachments are located in the OSC Emergency Kit.

b.

Assist in initial physical arrangement of the OSC facility per Section 5.2.2 of this procedure.

c.

Maintain dosimetry and equipment control throughout the emergency, utilizing Attachments 4 and 5 as appropriate.

d.

Dose tracking will normally be completed by logging in and out on MIS during an emergency. Attachment 4 may be used to provide additional documentation, as determined appropriate by the Health Physics Supervisor.

e. shall be maintained for each person manually if MIS is down or not available at the assembly area. Electronic Dosimeters (ED) can be used when MIS is down by using Radiological Work Practice 316, "Electronic Dosimetry Operations With MIS Down," instructions on how to operate on ED reader without MIS.

5.3.12 Health Physics Suoport HP Support shall:

a.

Assist in initial physical arrangement of the OSC facility per Section 5.2.2 of this procedure.

b.

Keep the status boards updated as information becomes available.

PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 13 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.13 Auxiliary Operator (AO)

a.

Report to the Control Room for accountability when the emergency siren is sounded. If an AO is carrying out an assignment thought to be critical, the AO should contact the Control Room for permission to continue.

b.

AOs will be dispatched from the Control Room until the OSC is declared operational.

c.

AOs dispatched from the Control Room should:

1.

Proceed to Access Control and obtain an electronic dosimeter.

2.

Log onto the pre-existing emergency RWP which will be a 6 digit "Year #-9999," ie, 96-9999.

3.

Enter the RCA and obtain a dose rate meter.

4.

Perform assignment.

5.

Update the Control Room Supervisor (CRS) frequently.

6.

Notify CRS when assignment is completed.

7.

If the OSC is NOT operational, an AO can be given another assignment or told to report back to the Control Room.

8.

If the OSC has been declared operational, an AO should report to the OSC Director.

d.

AOs being dispatched from the OSC should:

1.

Ensure their name is placed on the OSC Resources status board.

2.

Sign on the emergency RWP if not already done.

K..-

3.

Obtain an electronic dosimeter if not already done.

PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page 14 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION EVACUATION/RELOCATION If the area dose rate exceeds 100 mrem/hr or air concentration is 40 DACs, the OSC shall relocate to the Mechanical Maintenance Shop or the SED shall designate an alternate location. Evacuation shall be performed with the concurrence of the SED unless the delay caused by waiting for concurrence would endanger OSC personnel. The evacuation should be announced over the public address system. If the Mechanical Maintenance Shop is not habitable, the SED shall designate an alternate OSC location.

Equipment relocated upon evacuation shall be designated by the SED (or alternate) per Attachments 1 through 4 of Emergency Implementing Procedure El-16.1, "Maintenance of Emergency Equipment" (as appropriate).

ATTACHMENTS AND RECORDS 6.1 ATTACHMENTS 6.1.1, "Operational Support Center Activation List" 6.1.2, "Operational Support Center Floor Plan" 6.1.3, "Operational Support Center Organizational Chart" 6.1.4, "Operational Support Center Dosimetry Log Sheet" 6.1.5 Attachment Sheet" 5, "Operational Support Center Instrument Control Log 6.1.6, "Operational Support Center Request Form" 6.1.7, "Operational Support Center Response Team Form" 6.1.8., "Operational Support Center Response Team Checklist" 5.4 6.0 K)ý

PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page 15 of 15 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 6.1.9, "Sequence of Events Form" 6.1.10 0, "Operational Support Center Priority Form" RECORDS Records generated by this procedure shall be filed in accordance with Palisades Administrative Procedure 10.46, "Plant Records." Refer to the record matrix attached to AP 10.46. for information needed to complete Record Indexing Form (Form 104).

6.2

Proc No EI-4.2 Revision 14 Page 1 of 1 OPERATIONAL SUPPORT CENTER ACTIVATION LIST SECTION 1:

ASSEMBLY AND ACCOUNTABILITY

a.

OSC habitable? Yes_

No_

Classification Time

b.

Accountability completed.

Time

c.

Announce Key Players/Positions to OSC personnel.

Time

d.

Emergency Classification sign posted.

e.

Command and Control sign posted.

SECTION 2:

PHYSICAL ARRANGEMENT

a.

Layout per Attachment 2.

b.

Frisking station established.

c.

Dosimetry/Equipment control point established, rad controlled area, dosimetry records (Attachments 4, 5, and 6).

d.

Status boards in place.

e.

Sample station established.

f.

Communications with TSC and associated phone lines completed.

g.

Emergency MIS Computer.

OPERATIONAL SUPPORT CENTER FLOOR PLAN Proc No EI-4.2 Revision 14 Page 1 of 1 Rain Lockuerom Ausembly Arna V1 Naintenane.

lPerannel OSC BOARDS OSC-l -

OSC Resources OSC Emergency Onsite Monitoring Map OSC Response Teams OSC Monitoring Team Data**

OSC-5 OSC Priorities Board OSC Onsite Monitoring Board (Habitability Areas) **

OSC 10-Mile EPZ Map**

OSC Sequence of Events Board OSC CMWENCY KIT C

c MIS COIMPTER CARTS --

G ARE STORED INSIDE CAGELA TAX ROom No Twe ia 04 uii

-ii b

U Lunch Room Assembly Area V 2

n

-J 0

0 2

a L-fi~i hs A-1X11.w

  • OCPoes

-X 2596 (Chem)

-X 2409 (HP)

-X 2410 (HP Communicator)

-X 2346 (General)

-Direct Line to TSC

-X 2109 OSC Director

-X 2110 TIP

-X 764-2?30 (TAX)

-K 2243 (Haint. Commumicator)

-OSC to Met Tower Line (HP Radio)

-764-8994 Phone Jack under wall phone X2346

    • These boards are stored in the cage in the Fan Room behind OSC.

W 06C 02

(

OPERATIONAL SUPPORT CENTER ORGANIZATIONAL CHART

-w/Offulte Teams Counting.

  • The OSC Director is responsible for maintaining accountability of AOs after the OSC is declared operational and the Shift Supervisor has released them to the OSC.

Proc No EI-4.2 Revision 14 Page 1 of I

Proc No EI-4.2 Revision 14 Page 1 of 1 OPERATIONAL SUPPORT CENTER DOSIMETRY LOG SHEET Name SSN Department Available Dose Data Entered into MIS

Proc No EI-4.2 Revision 14 Page 1 of 1 OPERATIONAL SUPPORT CENTER INSTRUMENT CONTROL LOG SHEET Date:

Proc No EI-4.2 Revision 14 Page 1 of 1 OPERATIONAL SUPPORT CENTER REQUEST FORM FROM:

TIME:

REQUEST:

FROM:

TIME:

REQUEST:

Proc No EI-4.2 Revision 14 Page 1 of 1 OPERATIONAL SUPPORT CENTER RESPONSE TEAM FORM Team Number:

Type: __-Maint

-HP

-Chem

-Other:

(Identify the number of each type assigned to team)

Mission:

-Ops Time Requested:

Dispatched:

-___ Returned:

Team Number:

Type: __-Maint

_____-HP

-Chemn

-Other:

(Identify the number of each type assigned to team)

Mission:

Ops Time Requested:

Dispatched:

____Returned:

Team Number:

Type: _

-Maint HP

-Chemn

___-Other:

(Identify the number of each type assigned to team)

Mission:

-Ops Time Requested:

Dispatched:

Returned:

Proc No EI-4.2 Revision 14 Page 1 of 2 OPERATIONAL SUPPORT CENTER RESPONSE TEAM CHECKLIST Task

Description:

Team No:

Person Holding Brief Date/Time PREJOB General Task/Procedure Summary Expected Results Detail Task Review Precautions and Limitations Industrial Safety Radiation Safety Plant Condition IMPLEMENTATION Check-out Through Dosimetry Assess Job (Time Est, Damage, etc)

Report to OSC Director (Ext 2109)

Perform Task (Report Back Every 30 Minutes)

TASK COMPLETION Report to OSC Director and HP Supervisor for Debriefing When Complete Summarize Task Performed (On the Back of This Form)

Proc No EI-4.2 Revision 14 Page 2 of 2 OPERATIONAL SUPPORT CENTER RESPONSE TEAM CHECKLIST TASK

SUMMARY

Proc No EI-4.2 Revision 14 SEQUENCE OF EVENTS FORM Page 1 of 1 SEQUENCE OF EVENTS Updated By:

Date Time message I

I L

I I

4 I

4-I I-I I-4-

4

+

I i-

_I_

I i

+

I I

I i

I I

OPERATIONAL SUPPORT CENTER PRIORITY FORM Proc No EI-4.2 0 Revision 14 Page 1 of 1 L

J I-I I-

  • 1 VtTAL. EOU"'VTr OUT OF SERVICE COMPONEN~T REPAIR UINITATED~

TO BE 4VOMPLETED PRIORITY NdO COMPONENT FAILUREREAK DATI TIME::

bTIE DAT T

UPDATED BY: OSC COMMUNICATOR 4

4 4

4 4

4 4-4-

S J.

1 4

1 4

4-4-

I I

S J

I

1.

4-4-

1 4

4 4

1-4 4-4 4

4 4

+

+

0SC-5