TERMINATION AND RECOVERY PROCEDURE EPIP-16 BROWNS FERRY NUCLEAR PLANT J.
Attachment C (Page 1 of 1)
TVA RECOVERY ORGANIZATION Senior Vice President Nuclear Operations Manager of Nuclear Licensing and Regulatory Affairs Site Vice President Plant Manager CECC Information Manager Vice President Technical Support Administrative Support Groups
- Manager, Nuclear Fuels
- Manager, Emergency Preparedness
- Manager, Radiological Control
- Manager, Nuclear Security
- Manager, Nuclear Fire Protection FOR POSITION RESPONSIBILITIES REFER TO THE RADIOLOGICAL EMERGENCY PLAN SECTION 13.2 1
REVISION 4 I i
PAGE 8 OF 9
TERMINATION AND RECOVERY PROCEDURE EPIP-16 BROWNS FERRY NUCLEAR PLANT Attachment D (Page 1 of 1)
LOCAL RECOVERY CENTER 2nd Floor Plant Administrative Building Entrance Parking THE PURPOSE OF THE LOCAL RECOVERY CENTER (LRC) IS TO PROVIDE A FACILITY FOR TVA RECOVERY MANAGEMENT, NRC EMERGENCY RESPONSE PERSONNEL AND OTHER EMERGENCY AND/OR RECOVERY PERSONNEL.
THE LRC PROVIDES ADEQUATE SPACE FOR TVA AND OTHERS W'HO MAY LOCATE THERE TO SUPPORT THE SITE SHOULD ADDITIONAL OFFICE SPACE NEAR THE SITE BECOME NECESSARY DURING THE RECOVERY PHASE.
THE LRC FOR BROWNS FERRY WILL BE A PORTION OF THE SECOND FLOOR OF THE ADMINISTRATION BUILDING OUTSIDE THE PROTECTED AREA OF THE SITE.
THE LRC HAS VOICE COMMUNICATION CAPABILITIES TO ENABLE PERSONNEL TO COMMUNICATE WITH THE CECC AND THE BROWNS FERRY TSC. THE FOLLOWING VOICE COMMUNICATION IS AVAILABLE IN THE LRC AREA
- 1.
BELL TELEPHONE (LOCAL SERVICE)
- 2.
TVA MICROWAVE TELEPHONE SYSTEM
- 3.
LONG DISTANCE SERVICE METEOROLOGICAL INFORMATION AND DOSE RATE CALCULATIONS ARE ALSO AVAILABLE TO LRC PERSONNEL OTHER EQUIPMENT AVAILABLE FOR USE BY LRC PERSONNEL INCLUDE:
- 1.
FACSIMILE MACHINE
- 2.
COPY MACHINES
- 3.
HAND CALCULATORS
- 4.
PLANT-SPECIFIC DRAWINGS, MANUALS, AND PROCEDURES LAST PAGE REVISION 4 I PAGE 9 OF 9
TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE EPIP-17 Emergency Equipment and Supplies (Inventory and Operability Procedure)
REVISION 24 PREPARED BY: T. W. CORNELIUS RESPONSIBLE ORGANIZATION: EMERGENCY PREPAREDNESS APPROVED BY: T. W. CORNELIUS EFFECTIVE DATE: 04/23/2000 LEVEL OF USE: REFERENCE USE VALIDATION DATE: NOT REQUIRED PHONE: 2038 DATE: 04/21/2000 QUALITY-RELATED
REVISION LOG PROCEDURE NUMBER:
PAGES AFFECTED:
DESCRIPTION OF CHANGES:
NIC-27 EPIP-17 REVISION NUMBER: 24 24 Revised Attachment 15 to remove deleted procedure reference, Site Standard Practice (SSP) 1.52 titled "Emergency Preparedness Administration". The information supported by SSP-1.52 was incorporated into EPIP 8.
I I
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure) 1.0 PURPOSE The purpose of this procedure is to provide a listing of equipment and supplies, along with storage locations, available for emergency response during the activation of the Radiological Emergency Plan and Emergency Plan Implementing Procedures. This procedure will ensure the availability and readiness of emergency equipment at BFN through the performance of periodic inventories and operability checks.
2.0 SCOPE This procedure provides information pertaining to equipment and supplies available for use during emergencies at the Browns Ferry Nuclear Plant. This procedure additionally provides instructions to personnel performing checks of equipment and supplies in regards to frequencies, responsibilities, acceptance and record management.
3.0 INSTRUCTIONS 3.1 Responsibilities and Frequency 3.1.1 Inventories and operability checks shall be conducted in accordance with frequencies provided in Attachment 1. In addition with this frequency schedule, special inventories shall be required when items or equipment maintained by this procedure have been affected by a drill, exercise or training. This special inventory shall be performed at a reasonable time following the activity. This special inventory may also be used as the routine inventory.
3.1.2 Conduct of inventories and operability checks shall be the responsibility of the organization provided in Attachment 1 3.1.3 The Manager, Emergency Preparedness (EP), is responsible for ensuring the overall state of readiness of supplies and equipment identified in the procedure.
PAGE 1 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure) 3.1 Responsibilities and Frequency (Continued) 3.1.4 Individuals performing work within this procedure shall be familiar with all procedural guidance and testing requirements applicable to their assigned task. By initialing the item listing on the task form, the individual performing tasks within this procedure is responsible for ensuring the item is present, in the specified quantity and functional for its intended purpose.
3.1.5 Equipment inventories and operability of the site environmental monitoring vans shall be conducted in accordance with CECC-EPIP-9. Routine and special inventory/operability checks involving the site environmental monitoring vans are the responsibility of RADCON. Training personnel will be responsible for inventory and operability checks following training activities.
3.1.6 Personnel performing inventories and operability checks shall ensure that upon completion of task, seals or locking devices are in place to ensure the integrity of the equipment or supplies. Areas requiring these measures are listed on Attachment 2.
3.1.7 Personnel conducting inventories and operability checks in accordance with this instruction will ensure that the latest revision of this procedure is utilized.
3.1.8 Definition for annual and quarterly shall be as noted in the Radiological Emergency Plan. Terms such as once every calendar quarter or month invokes that the task should be conducted within the timeframe of a physical quarter or month.
3.2 Records Management 3.2.1 Personnel conducting tasks within this procedure will provide legible documentation of results on applicable forms.
3.2.2 Upon completion of applicable task(s), originals with signatures, shall be forwarded to the Manager, EP for review and concurrence. Originals should be forwarded as soon as possible, but no later than the end of the current quarter.
PAGE 2 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure)
/
3.1 Records Management(Continued) 3.2.3 The Manager, EP shall review all task forms and concur with results by signature.
3.2.4 EP shall maintain all procedure records for a minimum retention period of 1 year. These records are considered NON-QA.
3.3 Task Deficiencies Deficient items as discussed within this procedure do not relate to those described in SPP 3.1, "Corrective Action Program". Any deficient item identified within this procedure which does meet the requirements of SPP 3.1 shall be documented in accordance with SPP 3.1.
3.3.1 All task deficiencies shall be noted on the applicable task form.
3.3.2 All task deficiencies shall be corrected as soon as possible. If circumstances do not allow prompt correction the Manager, EP, shall be notified. When deficiencies have been corrected, the applicable task form shall be signed.
3.3.3 For failures of the NRC FTS-2000, Emergency Telecommunications System (ETS) deficiencies will be reported immediately in accordance with the instructions provided on the applicable task form.
PAGE 3 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEARPLANT Operability Procedure) 3.4 Specific Instructions for Inventories, Operability Checks, Administrative Checks and Reviews 3.4.1 SCBA's Self Contained Breathing Apparatus (SCBA) units are inventoried per this procedure for inventory purposes only. Inspections/equipment maintenance and operability checks are conducted in accordance with applicable Fire Protection Instructions.
3.4.2 Radiological Control Instrumentation 3.4.2.1 On-Site - Survey instrumentation, counting equipment, air samplers, dosimeters and other radiological control equipment listed on applicable forms are for inventory purposes only.
Instrument readiness is a process of the on-site radiological control organization. As a function of this inventory calibration due dates and instrumentation physical appearance will be observed to help ensure operability.
3.4.2.2 Off-Site - Survey instrumentation and dosimeters referenced as offsite by this procedure are considered those maintained by EP at the BFN - Agreement Hospitals. Survey instrumentation operability shall be maintained by the Western Area Radiological Laboratory, Instrumentation Section. Electronic dosimeters shall be exchanged according to response dates not to exceed calibration due dates. Electronic dosimetry should be observed for physical damage to help ensure operability.
3.4.3 Telecommunications 3.4.3.1 Nuclear Regulatory Commission - Emergency Notification System telephones. Lift the receiver and listen for a dial tone; after receiving a dial tone, dial the first number listed on the sticker located on the telephone instrument, using all 10 digits. If the first number is busy, proceed on with the second, etc. Confirm acceptable voice quality between parties conducting the test with all extensions off hook. Request a call-back be made to single phone and confirm acceptable voice quality.
PAGE 4 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventorv and EPIP-17 NUCLEAR PLANT Operability Procedure) 3.4 Specific Instructions for Inventories, Operability Checks, Administrative Checks and Reviews (Continued) 3.4.3 Telecommunications (Continued) 3.4.3.2 All other telecommunications tested by this procedure. Conduct the test by lifting receiver and listen for a dial tone; after receiving a dial tone, place a local call and request a call-back be made.
Confirm acceptable voice quality between telephones being tested.
3.4.4 TSC & OSC Intercom System Activate the intercom system in the TSC or OSC. Assign someone to monitor the test in the applicable locations. The TSC PA services the TSC, OSC and the Technical Assessment Team Area while the OSC PA services the OSC and OSC Staging Area.
3.4.5 EP Clocks Verify the correct operation of the TSC and the OSC clock by logging onto the clock program and making classification changes using the program. Return the system to the "No Classification" display.
Verify operability by faxing a test message to another telecopier. Fax a test message back to the telecopier being tested. Check telecopier paper and physical condition. Ensure legibility of test messages.
3.4.7 Telephone Headsets Configure headset as applicable. Make call and confirm acceptable voice quality using the microphone and ear piece.
3.4.8 Ring down Phones (CECC/TSC, TAT/Plt Assessment, ODS/Control Rooms 1/2 & 3)
Contact Corporate EP, have someone man the telephone in the CECC/ODS areas. Place a call to the CECC/ODS by lifting the receiver and receive a call form the CECC/ODS.
PAGE 5 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure) 3.4 Specific Instructions for Inventories, Operability Checks, Administrative Checks and Reviews (Continued) 3.4.9 Meteorological (MET) Data Terminal and Printer Log onto the MET terminal. Request information in printed format.
Verify that the printer has a supply of paper and that the print is legible.
Log off system.
3.4.10 OSC Computer & Printer (OSC)
Ensure the operability of the OSC computer by performing a task such as the activation of the word processing program. Check the response of the printer by requesting a print task via the computer, observe the action of the printer and print quality.
3.4.11 Copiers (TSC/OSC)
Verify operability by copying a test message through the copier. Make copies using the sorter and verify legibility of copies, check copy paper supply and physical condition of copier.
3.4.12 Batteries J
All batteries shall be observed for physical damage such as indentations, leaking or rust. Batteries shall be tested to determine effectiveness by battery tester. Batteries sealed by the manufacture with an affixed label indicating a "shelf life" can be exempted from the individual battery test and accepted as is, as long as the current date does not exceed the "shelf life" date. Sealed batteries which have a "shelf life" date that is exceeded by the current date can be utilized, but must pass a battery test utilizing the battery testor.
3.4.13 Zetron Radio Control Units (RCU)
Observe the unit to ensure that the time is displayed on the face plate.
Verify that a green indicator light appears by one of the radio frequency selector buttons. The RCU should be tested by contacting a normally manned station.
PAGE 6 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure)
I 3.4 Specific Instructions for Inventories, Operability Checks. Administrative Checks and Reviews (Continued) 3.4.14 Hand Held 2-Way Radios Observe the unit for physical damage, then assemble one of the battery packs to the radio. Make radio contact with another hand held unit and verify acceptable voice quality.
3.4.15 Control Room Conference Bridge (101/102)
Activate the "2-Way" bridge by dialing 101 on two plant telephones.
Verify acceptable voice quality. Then test the "Listen Only" bridge by having someone activate the "2-Way" bridge by dialing 101 and someone activate the "Listen Only" bridge by dialing 102. Verify that the 102 is a "listen Only" system.
3.4.16 ERO Logbooks Utilize EPIP-6 or 7, position attachments to identify what ERO logbooks are intended for use in the applicable centers. Review the logbooks to unsure that each contains:
(1)The latest revision of the applicable EPIP Attachment (2)An adequate supply of log sheets 3.4.17 Calculators, Flashlights, etc.
Verify functional by observing anticipated response.
3.4.18 Emergency Procedure Telephone Number Review and Update Certain EPIP's and site procedures contain telephone numbers utilized by response personnel. Once per calendar quarter these numbers will be reviewed to ensure accuracy and updates are made as applicable.
Changes will be conducted in accordance with site instructions.
PAGE 7 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EP IP-1 NUCLEAR PLANT Operability Procedure) 3.4 Specific Instructions for Inventories, Operability Checks, Administrative Checks and Reviews (Continued) 3.4.19 Review of Emergency Procedures In accordance with the Radiological Emergency Plan (REP) the REP, REP Appendices and the EPIPs shall be reviewed annually. Changes concerning the REP will be forwarded to the corporate EP staff for consideration and implementation as applicable. Changes noted concerning the EPIPs shall be considered and if applicable revisions conducted in accordance with site instructions.
3.4.20 Emergency Response List The Emergency Response List contains individuals which are allowed access to the protected area during an emergency at BFNP for the purposes of serving within the emergency response organization. This listing is updated quarterly and copies distributed to Nuclear Security.
The list will be issued on white paper and will not require PORC review.
3.4.21 Call-Out List This list contains active Emergency Responders by emergency positions.
This list is utilized as a tool for the call-out of emergency responders.
The list is updated quarterly and will be issued on white paper. The call out list will not be PORC reviewed.
3.4.22 Procedures and/or Drawings Controlled Procedures and/or drawings listed on applicable forms are for inventory purpose only. Procedure and Drawing inspection/maintenance process is conducted through applicable site instructions.
PAGE 8 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT 4.0 ATTACHMENTS 4.1 4.2 4.3 4.4 4.5 Attachment Attachment Attachment Attachment Attachment 1
2 3
4 5
4.6 Attachment 6 4.7 Attachment 7 4.8 Attachment 8 4.9 Attachment 9 4.10 Attachment 10 4.11 Attachment 11 4.12 Attachment 12 4.13 Attachment 13 4.14 Attachment 14 4.15 Attachment 15 4.16 Attachment 16 4.17 Attachment 17 4.18 Attachment 18 Inventory Matrix Table Locked/Sealed Cabinet Listing Radcon Emergency Equipment - Service Building 565' Radcon Emergency Equipment - Control Building 617" Staging Area C-Zone Dress-Out Clothing - Service Building 565' Emergency Use SCBA Inventory Maintenance Emergency Tool Box Inventory, Clean Tool Room - Service Building 565' Technical Support Center Inventory/Operability Check Operations Support Center Inventory/Operability Check OSC Staging Area Inventory/Operability Check Huntsville/Decatur General Hospital Inventory/Operability Checks ETS Communications Operability Checks Local Recovery Center Inventory/Operability Checks EP Quarterly Administrative Checks and Reviews EP Once per Calendar Quarter Administrative Checks and Reviews EP Annual Administrative Checks and Reviews Alternate Decontamination Facility Inventory-Operability Deficiency/Resolution Form PAGE 9 OF 35
"-*~
_./
REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT Inventory Matrix Table EPIP Attachment Number 3
4 5
6 7
8 9
10 11 12 13 14 15 16 17 Description Radcon Emergency Equipment - Service Building 565' Radcon Emergency Equipment - Control Building 617' Staging Area C-Zone Dress-Out Clothing Setr,ice Building 565' Emergency Use SCBA lnventoty AIfaintenance Emergency Tool Box Inventory, Clean Tool Room Service Building Technical Support Center Inventory/Operability Check Operations Support Center hIventory/AOperability Check OSC Staging Area hn'entoty/Operability Check Huntsville/Decatur General Hospital Inventory/Operability Checks ENS Alonthly Communications Operability Check Local Recover, Center Inventoty/Operability Check EP Quarterly Administrative Checks and Reviews EP Once per Calendar Quarter Administrative Checks and Reviews EP Annual Administrative Checks and Reviews Alternate Decontamination Facility Responsible Section Radcon Radcon Radcon Operations Maintenance EP EP EP EP EP EP EP EP EP EP PAGE 10 OF 35
- Frequenc, Once every calendar quarter Once every calendar quarter Once every calendar quarter Once every calendar quarter Once every calendar quarter Once every calendar quarter Once every calendar quarter Once every calendar quarter Once every calendar quarter Once monthly Once every calendar quarter Once quarterly Once every calendar quarter Once annually Once every calendar quarter Specii Instructions Provided Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT Locked/Sealed Cabinet Listing Cabinet Equipment and Supplies Cabinet Equipment and Supplies Cabinet Equipment and Supplies Cabinet Equipment and Supplies Cabinet Equipment and Supplies Cabinet (Radcon)
Equipment and Supplies Cabinet (Radcon)
Equipment and Supplies Cabinet (Hospital)
Equipment and Supplies Cabinet (Hospital)
Equipment and Supplies Cabinet (Alternate Decontamination Facility)
Location Technical Support Center Operations Support Center OSC Staging Area Local Recovery Center Service Building 565' Control Building 617' Decatur General "Emergency Room" Huntsville Hospital "Emergency Room" Power Service Shop # 4 TVA Muscle Shoals Reservation PAGE 11 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT Radcon Emergency Equipment - Service Building 565' Location: Service Building 565' Behind Radiological Control Lab Equipment Radiological Survey Instrumentation High Range Survey Meters Ion Chambers GM Survey Meters (Friskers)
Neutron Survey Meter Silver Zeolite Cartridges Alpha Survey Meter Mini-Scaler Hi-Volume Air Sampler Low-Volume Air Sampler Shielded Detector "Pig" (Located in Radcon Area, Service Building, 565)'
Dosimetry Dosimetry Chargers Whole Body TLD's Multi-Badge Sets Extremity TLD Badge Sets 0-200 mr Pocket Chambers 0-500 mr Pocket Chambers 0-1500 mr Pocket Chambers 0-5 R Pocket Chambers 0-20 R Pocket Chambers 0-100 R Pocket Chambers Miscellaneous Calculator (Hand Held)
Batteries (D-Cell)
Log Book Flashlights Box of Pens Particulate Air Filters (Box)
Disc Smears (Box)
KI Tablets Expiration Date (Radcon Supply Cage)( Tablets)
Signatures:
Supervisor, Radcon:
Date:
Manager, EP: ____
_Date:
Retention Period is 12 months - - Non-QA Record j
INV OPER INIT QTY 2
4 2
1 10 1
1 2
1 2
10 10 30 10 10 10 10 10 10 1
16 1
8 1
2 1
2000 Y
Y N
N Y
N I
PAGE 12 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT Radcon Emergency Equipment - Control Building 617' Location: Control Building 617' Mechanical Equipment Room Equipment QTY 1NV OPER INIT Radiological Survey Instrumentation High Range Survey Meters 2
Ion Chambers 4
GM Survey Meters (Friskers) 2 Neutron Survey Meter 1
Silver Zeolite Cartridges 10 Alpha Survey Meter 1
Mini-Scaler 1
Hi-Volume Air Sampler 2
Low-Volume Air Sampler 1
Shielded Detector "Pig" 1
Dosimetry Dosimetry Chargers 2
Whole Body TLD's 10 Multi-Badge Sets 10 Extremity TLD Badge Sets 30 0-200 mr Pocket Chambers 10 0-500 mr Pocket Chambers 10 0-1500 mr Pocket Chambers 10 0-5 R Pocket Chambers 10 0-20 R Pocket Chambers 10 0-100 R Pocket Chambers 10 Miscellaneous Calculator (Hand Held) 1 Y
N Batteries (D-Cell) 16 Y
N Log Book 1
Flashlights 8
Y N
Box of Pens 1
Particulate Air Filters (Box) 2 Disc Smears (Box) 1 Signatures:
Supervisor, Radcon:
Date:
Manager, EP:
"_Date:
Retention Period is 12 months - - Non-QA Record PAGE 13 OF 35 I
REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT Staging Area C-Zone Dress-Out Clothing - Service Building 565' Location: Service Building Column 6, G-line Hallway behind Mechanical Maintenance Offices Equipment Coveralls (Pairs)
Based upon size availability an alternate distribution may be acceptable at the discretion of the Radcon Supervisor and the EP Manager, noted by signature of completed form.
Size 46 Size 48 Size 50 Size 52 Size 54 Size 58 Hood covers Shoe Covers (Pairs)
Surgeon Caps Rubber Gloves (Pairs)
Booties (Pairs)
Cotton Glove Inserts (Pairs)
Masking Tape (Rolls)
QTY 40 10 10 5
5 5
5 25 25 25 25 25 25 8
INV INIT h ______________
A Si2natures:
Supervisor, Radcon:
Date:
Manager, EP: _____Date:
Retention Period is 12 months - - Non-QA Record I
PAGE 14 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT Emergency Use SCBA Inventory Description Self Contained Breathing Apparatus Self Contained Breathing Apparatus Self Contained Breathing Apparatus 45 cu. ft. Air Cylinder Self Contained Breathing Apparatus and 10 additional cylinders Self Contained Breathing Apparatus Self Contained Breathing Apparatus Self Contained Breathing Apparatus Self Contained Breathing Apparatus Self Contained Breathing Apparatus Self Contained Breathing Apparatus I
Location Unit 1 Control Room Unit 2 Control Room Unit 3 Control Room Service Building Elevation 565, Service Shop Hallway Fire Equipment Cabinet Turbine Building - 557' 4kV Shutdown Bd Rm "C" 3A Electrical Board Room Fire Equipment Cabinet Stairwell - RB 1&2 El. 565' Fire Equipment Cabinet Stairwell - RB 2&3 El. 565' Radcon Emergency Cart Fire Truck
(*) Required for by 10 CFR 50 Appendix R Support Signatures:
Supervisor, FIREPROTECTION:
Date:
Manager, EP:
___Date:
Retention Period is 12 months - - Non-QA Record PAGE 15 OF 35 INV INIT QTY 5
5 5
15 10
- 5 5
4 4
2 4
INV REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT (Page 1 of 4)
Maintenance Emergency Tool Box Inventory Electrical Tool Box Number of Boxes 2 -- Number of Boxes Inventoried Tool Description Pliers, Needle Nose, 6" Pliers Diagonal, 6" Tester, Circuit, 24.0" Rule, Folding, Carpenters, Outside Reading, 6' Pliers, Tongue & Groove, 10", #430 Channel Locks Screwdriver, STD Tip,.25" Tip, X 8.0" Long Screwdriver, STD Tip,.313" Tip, X 4.0" Long Screwdriver, STD Tip,. 125" Tip, X 6.0" Long Pliers, Lineman's, 9.0" Screwdriver, STD Tip,.25" Tip, X 6.0" Long Screwdriver, Phillips Tip, #2 Tip, 4" Blade Screwdriver, Holding,.25" X 6" (Klein)
Wrench, Adjustable, 10.0" I
PAGE 16 OF 35 QTY INV INIT 2
2 2
2 2
2 2
2 2
2 2
2 2
REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-1/
NUCLEAR PLANT Operability Procedure) (Page 2 of 4)
Maintenance Emergency Tool Box Inventory I&C Tool Box Number of Boxes 2 -- Number of Boxes Inventoried Tool Description QTY INV INIT Pliers, Tongue & Groove, 9, #42 Channel Locks 1
Screwdriver, STD Tip,.25" Tip, X 6.0" Long 1
Screwdriver, Jewelers, Set of Six,.25"-. 100" Mfg. Starrett 1
Screwdriver, Holding,.25" X 6" (Klein) 1 Cord, Extension, 110 V 100' 1
Wrench Set, Hex Key (Allen), Folding, 0.050"-0. 187" 1
Wrench, Ignition, Set 1
Wrench, Valve Wheel, Number 0, 8.0"X.50"X.656" 1
Socket, Set, 1/4" DR., SL/DW, 3/16" to 9/16" 1
Driver, Nut, Set, Fractional 1/4" to 1/2" 1
Wrench, Set, Hexkey,.028" to 5/8" 1
Cutter, Tube,.125" to.625" 1
Cutter, Tube,.125" to 1.125" 1
Pliers, Diagonals, 6" 1
Pliers, Lineman, 7" 1
Pliers, Needle Nose, 7" 1
Pliers, Tounge & Groove, #430 CL.
1 File, Half Round, 4" Smooth 1
File, Round, 6" Smooth 1
Puller, Fuse, Midget 1
Puller, Fuse, 100A-250V 1
Screwdriver, Philips, #1x3" 1
Screwdriver, Phillips, #2x4" 1
Screwdriver, Flat, 1/8x2.25" 1
Screwdriver, Flat, 1/4x6" 1
Screwdriver, Flat, 1/4x4" I
Screwdriver, Flat, 5/16x6" 1
Screwdriver, holding, SM/pocket Clip 1
Screwdriver, Holding, 3/16x6" 1
Screwdriver, holding, 1/4x8" 1
Wrench, Adjustable, 4" 1
Wrench, Adjustable, 6" 1
Wrench, Adjustable, 8" 1
PAGE 17 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEARPLANT Operability Procedure)
J (Page 3 of 4)
Maintenance Emergency Tool Box Inventory I&C Tool Box (CONTINUED)
Tool Description QTY INV NIT Wrench, Combo, 3/8" 1
Wrench, Combo, 7/16" 1
Wrench, Combo 1/2" 1
Wrench, Combo, 9/16" 1
Wrench, Combo,5/8" 1
Wrench, Combo, 11/16" 1
Wrench, Combo, 3/4" 1
Wrench, Flare Nut, 1/2"-9/16" 1
Wrench, Flare Nut, 5/8"-1 1/16" 1
Wrench, Flare Nut, 3/4"- 1" 1
Wrench, Flare Nut, 7/8"-1 1/8" 1
Snoop, Bottle, 8 oz 1
Note: The following items are supplied by the I&C Shop I
Tube Fitting, 1/4"M NPT to 3/8" tube comp 2
Tube Fitting, 1/4"F NPT to 1/4" tube comp 2
Tube Fitting, 3/8" comp to 3/8" comp 2
Tube Fitting, 1/4" comp to 1/4" comp 2
Tube Fitting, Tee, 1/4" comp 2
Tape, Electrical, Scotch 33 Black 1
Leads, Test, 4' 1
Jumpers, Banana, 2' orange w/clips 2
Tywraps, 3/16"x8" 1PK Tywraps, 1/8"x4" 1PK Valve Wrench, Custom Made, I&C Specs.
1
.I PAGE 18 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT (Page 4 of 4)
Maintenance Emergency Tool Box Inventory Mechanical Tool Box Number of Boxes 2 -- Number of Boxes Inventoried Tool Description QTY INV INIT Flux, Soldering 1
Chisel, Cold,.4375" Cut 1
Wrench Set, Combo, 0.250"-1.250" 1
Wrench Set, Hex Key (Allen), 0.187"-0.375" 1
Wrench Set, Hex Key (Allen), Folding, 0.050"-0. 187" 1
Socket Set,.375" 1
Hammer, Ball Pein, 12 oz 1
Punch, Pin,.188" 1
Punch, Pin,.125" 1
Pliers, Tongue & Groove, 9" #420 Channel Locks 1
Screwdriver, Phillips Tip, Round Shank, #2 Tip X 4.0" 1
Blade Screwdriver, Phillips Tip, Round Shank, #2 Tip X 1.50" 1
Blade Screwdriver, STD Tip,.25" Tip X 6.0" Long 1
Screwdriver, STD Tip,.25" Tip X 12.0" Long 1
Wrench, Pipe, 12" 1
Wrench, Adjustable, 12.0" 1
Pliers, Slip Joint, 10" 1
Pliers, Needle Nose, W/Side Cutter, 8" 1
Signatures:
Supervisor, Tool Room:
Date:
Manager, EP: __Date:
Retention Period is 12 months - - Non-QA Record PAGE 19 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEARPLANT Operability Procedure) (Page 1 of 4)
Technical Support Center Inventory/Operability Check Equipment QTY INV OPER INIT In the Technical Support Center Telecopier 2
Y N
Telecopier (TAT Area) 1 Y
N TSC Intercom System 1
Y N
TSC Zetron Radio System 1
Y N
Copier 1
Y N
EP Clock 1
Y N
Control Room Conference Bridge Headset 2
Y N
Met Data Terminal & Printer 1
Y N
ERO Logbooks Accountability Roster 1
N ICS Terminal (TAT Area) 1 Y
N In TSC Equipment & Supply Cabinet Calculators, (Scientific) 6 Y
N Flashlights 12 Y
N Batteries (D-Cells) 24 Y
N Batteries (AA) 24 Y
N Telephone Headsets (Spares) 3 Y
N Staplers 1
Pens (Black Ink) 24 Pencils 12 Tape Dispensers w/tape 1
"Post-it-notes" Pads 12 Message Pads 12 Note Pads (8.5"x 11")
12 Board Cleaner (Bottles) 1 Paper Towels (Rolls) 1 Grease Pencils 12 Dry Erase Markers 12 Copier Paper (Packs) 4 Spare Phones for NRC ETS 6
PAGE 20 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure) (Page 2 of 4)
Technical Support Center Inventory/Operability Check Procedures/Drawings QTY INV OPER INIT In the Technical Support Center
- R4EP 4
- BFN EPIP's 11
- CECC EPIP's 2
- Severe Accident Management Guidelines Flowcharts 1 Set
- Technical Support Guidelines 1 Set
- Emergency Operating Instruction (EOI)
Flowcharts 1 Set
- EOI Program Manual 1 Set
- Radiological Control Instructions 1 Set
- Abnormal Operating Instructions 1 Set
- REND 2
- AI Radiological Emergency Response Plan 1
- Multi-Jurisdictional Radiological Emergency Response Plan TEMA 1
- Alarm Response Procedures 1 Set
- Operating Instructions 1 Set
- Technical Specifications 1 Set
- Technical Requirements 1 Set
- Safe Shutdown Instructions 1 Set
- Fire Protection Report 1 Set
- Final Safety Analysis Report 1 Set
- User Manual Meteorological Data Display Program CECC 1
- User Manual Nuclear Power (NP) Sites Emergency Paging System (EPC) CECC 1
- FRED Forecast Radiological Emergency Dose 1
- User Manual Meteorological Data Print Program 1
- Plant Drawings 1 Set Radcon Survey Maps 1 Set EP 10-Mile Sample Point Map 2
EP 2-Mile Sample Point Map 1
EP 50 Mile Sample Point Map 1
EP 10 Mile Evacuation Sector Map 1
Operators Manual Zetron Radio Console 1
- Controlled Documents or Drawings PAGE 21 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure) (Page 3 of 4)
Technical Support Center Inventory/Operability Check Procedures/Drawings QTY INV OPER INIT In the Technical Assessment Team Area
- REP 1
- BFN EPIP's 2
- RIEND 1
- Operating Instructions 1 Set
- Technical Specifications 1 Set
- Technical Requirements 1 Set
- UMMI 1 Set
- UEMI 1 Set
- EMI 1 Set
- Unit 2 EOI Appendices 1
- Unit 3 EOI Appendices 1
- SAMG EOI Appendices 1
- SPCC Plan 1
- Plant Drawings 1 Set l
"I*t PAGE 22 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT (Page 4 of 4)
Technical Support Center Inventory/Operability Check Technical Support Center Telephones Telephone Number 3777 3730 3771 3770 3732 3764 3761 3765 3767 3766 3768 3763 3779 3782 (Node 2 Jack Only) 3784 (Node 2 Jack Only)
Operable Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Initials Telephone Number 2305 3734 3733 3736 3735 3744 3756 3745 3738 3740 3762 w/Headset 3769 w/Headset 3737 w/Headset CECC Ringdown 101/102 Bridge 103 Radcon Bridge p
p Operable Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Y
N Control Rooms Telephone Number Operable Initials Telephone Number Operable Initials ODS Unit 1/2 Ringdown Y
N ODS Unit 3 Ringdown Y
N Unit 1/2 Bridge Headset Y
N Unit 3 Bridge Headset Y
N Unit 1/2 Fixed Satellite Unit 3 Fixed Satellite Telephone Y
N Telephone Y
N Manager, EP:
Date:
Retention Period is 12 months - - Non-QA Record PAGE 23 OF 35 Initials REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure) (Page lof 2)
Operations Support Center Inventory/Operability Check Equipment QTY INV OPER INIT In the Operational Support Center Telecopier 1
Y N
OSC Intercom System 1
Y N
Copier 1
Y N
EP Clock 1
Y N
Computer Terminal 1
Y N
Printer for Computer 1
Y N
Accountability Roster 1
OSC Zetron Radio System 1
Y N
RADCON Zetron Radio System 1
Y N
ICS Terminals 2
Y N
In OSC Equipment & Supply Cabinet Calculators, (Scientific) 6 Y N Flashlights 12 Y
N Batteries (D-Cells) 24 Y
N Batteries (AA) 24 Y
N Telephone Headsets (Spares) 2 Y
N Staplers 3
Pens (Black Ink) 24 Pencils 12 Tape Dispensers w/tape 1
"Post-it-notes" Pads 12 Message Pads 12 Note Pads (8.5 "x 11")
12 Board Cleaner (Bottles) 1 Paper Towels (Rolls) 1 Grease Pencils 12 Dry Erase Markers 12 Copier Paper (Packs) 4 Hand Held 2-Way Radios 10 ERO Logbooks
PAGE 24 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT (Page 2of 2)
Operations Support Center Inventory/Operability Check Operations Support Center Telephones Telephone Number 3276 3233 2964 2599 2558 2026 3184 3780 3172 3750 (Node 1Jack Only) 3752 (Node 1 Jack Only)
Operable V
V V
V V
V V
V V
V V
N N
N N
N N
N N
N N
N Initials Telephone Number I Operable 3639 3274 2942 3225 2598 3660 2904 3093 3001 w/Headset 2089 w/Headset V
Y Y
Y Y
V Y
Y Y
Y N
N N
N N
N N
N N
N Initials L
A J
.1.
PAGE 25 OF 35 Manager, EP:
Date:_
Retention Period is 12 months - - Non-QA Record REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT 0 OSC Staging Area Inventory/Operability Check Equipment In the OSC Staging Area Equipment & Supply Cabinet Calculators, (Scientific)
Flashlights Batteries (D-Cells)
Staplers Pens (Black Ink)
Pencils Tape Dispensers "Post-it-notes" Pads Message Pads Note Pads (8.5 "x 11 ")
Accountability Roster ERO Logbooks In the OSC Staging Area Ice Vests Ice Packs for vests QTY 1
12 24 1
24 12 1
12 12 12 1
12 72 INV OPER V
V V
N N
N INIT Operations Support Center Sta~in2 Area Telephones Telephone Number Operable Initials Telephone Number Operable Initials 2244 Y
N 2115 Y
N 2309 Y
N 2215 Y
N 2303 Y
N
- Utilize EPIP-7, position attachments to identify what ERO logbooks are intended for use in the OSC Staging Area.
Manager, EP:
Retention Period is 12 months - - Non-QA Record Date:
PAGE 26 OF 35 j
I REVISION 24
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure) 1 (Page 1 of 2)
Huntsville/Decatur General Hospital Inventory/Operability Check (Circle One)
Hospital Equipment & Supply Cabinet QTY INV OPER INIT Personnel Dress-Out Clothin2 "Booties" (Pairs) 10 Dress Out Packages 10 Surgical Gloves (Pairs) 50 Surgical Gowns 3
Surgical tape for dressout (Rolls) 4 Rad Monitoring Instruments & Dosimetry Bicron Surveyor 50 (GM) or equivalent 2
Y N
Bicron RSO 5 (Ion Chamber) or equivalent 1
Y N
TLD's 10 Electronic Dosimeters 10 Wound Probe w/Cable 1
Zone. Survey & Contamination Control Supplies Floor Covering (Set) 1 Duct Tape (Rolls) 2 Rad Posting Signs 8
Contamination Smears 100 Step-Off-Pads 2
Rad Ribbon or rope (Rolls) 1 Massilin Mop 1
Massilin Cloths 20 Rad Emblem Tape (Rolls) 1 Flexible Funnel w/ drain hose 1
Fluid Collection Bottle (2 Gallon rinm.)
1 3ft. Wide Paper (Feet) 20 Cotton Swabs 12 Radioactive Material Tags 12 Traffic Cones (set) 1
.1 L
J PAGE 27 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT I 1 (Page 2 of 2)
Huntsville/Decatur General Hospital Inventory/Operability Check I
Manager, EP:
Date:
Retention Period is 12 months - - Non-QA Record I
PAGE 28 OF 35 Zone, Survey & Contamination Control QTY INV OPER INIT Supplies (Continued)
Scissors 1
Plastic Bags (Large) 10 Plastic Bags (Medium) 10 "Zip Lock" Plastic Bags 24 Skin Decon Media (Container) 1 Sample Bag Labels 12 Hospital Response Booklet (Hospital Specific) 1 Wall Poster ("Care of Contamination Patients")
1 NCRP Report # 65 (Issued Date - April 15, 1980) 1 Decontamination Table, bottle and Backboard 1
REVISION 24
EMERGE(
EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-I /
BROWNS FERRY NUCLEAR PLANT 2 ETS Communications Operability Check Description Reactor Safety Counterpart Link (RSCL)
Protective Measures Counterpart Link (PAICL)
Management Counterpart Link (MCL)
Local Area Network (LAN) Access (Check this line by use of a telephone instrument)
- Emergency Notification System (ENS)
- Emergency Notification System (ENS)
- Emergency Notification System (ENS)
- Emergency Notification System (ENS)
-,J.
Location TSC (NRC Area)
TSC (NRC Area)
TSC (NRC Area)
TSC (NRC Area)
TSC (NRC Area)
TSC (TUA Area)
TSC (NRC Area)
TSC (TJA Area)
Unit 1/2 Control Room Unit 3 Control Room Teleohone Number (700) 221-7996 (700) 221-7997 (700) 221-7995 (700) 221-7994 (700) 221-7992 (700) 221-7992 (700) 221-7991 (700) 221-7991 (700) 221-7991 (700) 221-7991 r
I OPER Y
N Y
N Y
N Y
N Y
V V
V V
V N
N N
N N
N IINI
- Notify the Shift Manager prior to beginning the ENS telephone checks Note: IMMEDIATELY, Report Failures to (1) the Shift Manager, and (2) the NRCOC at 9-1-301-951-0550 from a TVA telephone. (The NRC may request that Browns Ferry conduct repairs.)
Note: Upon Completion of repairs, perform a test of the affected telephones. If test is satisfactory, inform the SOS and the NRCOC.
Manager, EP:
Date:
Retention Period is 12 months - - Non-QA Record PAGE 29 OF 35 REVISION 24 M
1 t
EMERGENCY EQUIPMENT AND BROWNS FERRY SUPPLIES (Inventory and EPIP-17 NUCLEAR PLANT Operability Procedure) 3 (Page 1 of 2)
Local Recovery Center Inventory/Operability Check Equipment QTY INV OPER INIT In the LRC Area Met Data Terminal 1
Y N
Printer for Met Data Terminal 1
Y N
ICS Terminal 1
Y N
In LRC Equipment & Supply Cabinet Calculators, (Scientific) 4 Y
N Flashlights 12 Y
N Batteries (D-Cells) 24 Y
N Staplers 1
Pens (Black Ink) 24 Pencils 12 Tape Dispensers 1
/!
"Post-it-notes" Pads 12
-_1_
Message Pads 12 Note Pads (8.5"x 11")
12 Board Cleaner (Bottles) 2 Paper Towels (Rolls) 1 Dry Erase Markers 12 PAGE 30 OF 35 REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT 3 (Page 2 of 2)
Local Recovery Center Inventory/Operability Check PAGE 31 OF 35 Telephone Number Operable Initials Telephone Number Operable Initials 2038 Y
N 2692 Y
N 3666 Y
N 2460 Y
N 3636 Y
N 2064 Y
N 3656 Y
N 3647 Y
N 3645 Y
N Portable Satellite Telephone Y
N Manager, EP:
Date:_
Retention Period is 12 months - - Non-QA Record REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT 4 EP Quarterly Administrative Checks and Reviews Emergency Response List Update
- Nuclear Security Shift Supervisor's Office (5-Copies)
Call-Out List
- Shift Manager L
.1.
L PAGE 32 OF 35 I
INV DATE INIT QTY 5
1 Manager, EP:
Date:_
Retention Period is 12 months - - Non-QA Record REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT 5 EP Once per Calendar Quarter Administrative Checks and Reviews PAGE 33 OF 35 QTY INV DATE INIT Emergency Procedure Telephone Number Review and Update
- BFNP Emergency Preparedness ALL Implementing Procedures Manager, EP:
Date:_
Retention Period is 12 months - - Non-QA Record I
REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT 6 EP Annual Administrative Checks and Reviews Review Emergency Procedures
"* Radiological Emergency Plan
"* Browns Ferry, Emergency Plan Implementing Procedures QTY NA NA PAGE 34 OF 35 I
INV DATE INIT Manager, EP:
Date:
Retention Period is 12 months - - Non-QA Record REVISION 24
EMERGENCY EQUIPMENT AND SUPPLIES (Inventory and Operability Procedure)
EPIP-17 BROWNS FERRY NUCLEAR PLANT 7 Alternate Decontamination Facility Power Service Shop # 4 - TVA, Muscle Shoals Reservation Si2natures:
Inventoried/Inspected by Date:
Manager, EP:
Date:
Retention Period is 12 months - -Non-QA Record LAST PAGE PAGE 35 OF 35 Equipment QTY INV INIT Supply Cabinet Cotton Tipped Swabs 2 PKG Square Gauze 1 Box Detergent 1 Box Surgical Brush 12 Waterless Hand Cleaner 2 Cans Shampoo 2 BTL Paper Bath Towels 100 Small Coveralls 12 Medium Coveralls 12 Large Coveralls 12 Small Tennis Shoes 12 Large Tennis Shoes 12 L
J a
REVISION 24
TENNESSEE VALLEY AUTHORITY BROWNS FERRY NUCLEAR PLANT EMERGENCY PLAN IMPLEMENTING PROCEDURE EPIP-21 FIRE EMERGENCY PROCEDURE REVISION 3 PREPARED BY: T. W. CORNELIUS RESPONSIBLE ORGANIZATION: EMERGENCY PREPAREDNESS APPROVED BY: GILBERT LITTLE EFFECTIVE DATE: 05/15/2000 LEVEL OF USE: REFERENCE USE VALIDATION DATE: NOT REQUIRED PHONE: 2038 DATE: 05/15/2000 QUALITY-RELATED
REVISION LOG Procedure Number: EPIP-21 Revision Number: 3 Pages Affected: All Pagination Pages: NONE Description of Change:
IC This is a general revision to EPIP-2 1. The revision is being conducted to re-format the procedure, apply the document control storage filter, and at step 3.3.1 (page 1) add direction for the Shift Manager to refer to SSI-001 as applicable based upon the severity of the fire.
t
FIRE EMERGENCY PROCEDURE 1BROWNS FERRY EPIP-21NUCEAR 1.0 PURPOSE To provide timely response to fire emergencies at Browns Ferry and a mechanism to notify additionally emergency personnel or resources as needed.
2.0 SCOPE This procedure applies to all fire emergencies at Browns Ferry.
3.0 INSTRUCTIONS 3.1 General 3.1.1 All members of the fire response team will proceed to the scene upon hearing the announcement.
3.2 Initial Notification by Unit Operator 3.2.1 Upon receiving a fire emergency call, the Unit 1 Control Room Unit Operator will:
"* Obtain name of caller.
"* Obtain location of fire.
"* Obtain nature of fire.
"* Obtain telephone number from caller.
3.2.2 Initiate the "Fire Alarm Bell".
3.2.3 Announce fire location over the plant public address (PA) system, repeating at regular intervals until instructed otherwise by Shift Manager or Unit Supervisor.
3.2.4 Notify the Fire Protection Personnel using the Operations/Fire Protection Radio.
3.2.5 Notify the Shift Manager of the fire.
3.3 Shift Mananer Responsibilities 3.3.1 The Shift Manager will:
"* Dispatch Unit Supervisor or designee to the scene to act as Incident Commander.
"* Establish and maintain communications with the Incident Commander.
"* Refer to SSI-001 for applicability based on the severity of the fire.
3.3.2 When requested by the Incident Commander notify the off-duty BFN fire protection personnel. Notify the off-duty BFN fire protection personnel from list in the Shift Manager office. This list will be maintained by the Fire Protection Organization.
PAGE 1 OF 2 REVISION 3
FIRE EMERGENCY PROCEDURE EPIP-21 BROWNS FERRY NUCLEAR PLANT 3.3 Shift Manager Responsibilities (Continued) 3.3.3 When requested by the Incident Commander notify of the Clements Volunteer Fire Department. Notify the Clements Volunteer Fire Department by calling the Limestone County Sheriffs Dispatcher (233-3473).
3.3.4 Following an "Appendix R Fire" - direct the Operations Support Center (OSC) to provide ventilation of Shutdown Board Rooms by MSI-0-000-PROO05, Electrical Equipment Room Emergency Ventilation.
3.4 Incident Commander Responsibilities 3.4.1 The Incident Commander will:
"* Establish radio communication with the Shift Manager.
"* Keep Shift Manager advised of situation.
"* Request Shift Manager to call in off-site support as needed.
3.5 RADCON Representative Responsibilities 3.5.1 The RADCON Representative will:
"* Advise the Incident Commander of radiological hazards.
"* Ensure the Incident Commander is aware of areas of significant radiation exposure and airborne radioactivity that may affect stay time for team members.
"* Notify the Incident Commander of any team members limitations in regards to stay time.
4.0 ATTACHMENTS None L
LAST PAGE I
PAGE 2 OF 2 REVISION 3