LR-N14-0030, Technical Specification 6.9.1.5.b, 2013 Annual Report of SRV Challenges

From kanterella
Jump to navigation Jump to search
Technical Specification 6.9.1.5.b, 2013 Annual Report of SRV Challenges
ML14042A225
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 02/11/2014
From: Carr E
Public Service Enterprise Group
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
LR-N14-0030
Download: ML14042A225 (2)


Text

PSEG Nuclear LLC P.O. Box 236, Hancocks Bridge, New Jersey 08038-0236 I>SEG NuclearLLC FEB 1 1 2014 Technical Specifications 6.9.1.5b LR-N14-0030 United States Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Subject:

Hope Creek Generating Station Renewed Facility Operating License No. NPF-57 NRC Docket No. 50-354 Technical Specification 6.9.1.5.b 2013 Annual Report of SRV Challenges This report is being submitted in accordance with Hope Creek Technical Specification 6.9.1.5b, which requires the documentation of all challenges to main steamline safety/relief valves (SRVs) be provided on an annual basis to the Administrator Region I, Nuclear Regulatory Commission.

During 2013, the SRVs were challenged one time during a turbine trip and associated reactor scram that occurred on December 1, 2013. Three SRVs (H, M, P) lifted on the initial transient. No other challenges occurred during the year.

There are no regulatory commitments contained in this letter.

Should you have any questions, please contact Mr. Philip Duca at 856-339-1640.

Sincerely,

~

-'~

~~

-_/

---.~~-",

Eric S. Carr Plant Manager - Hope Creek

LR-N14-0030 Page 2 of 2 cc:

Mr. W. Dean, Regional Administrator - Region 1 Nuclear Regulatory Commission 2100 Renaissance Blvd, Suite 100 King of Prussia, PA 19406-2713 U. S. Nuclear Regulatory Commission Mr. J. Hughey, Project Manager - Hope Creek Mail Stop 08B1A Washington, DC 20555-0001 USNRC Senior Resident Inspector - Hope Creek (X24)

Mr. P. Mulligan, Manager IV Bureau of Nuclear Engineering New Jersey Department of Environmental Protection PO Box 420 Trenton, New Jersey 08625 Hope Creek Commitment Coordinator (H02)

Corporate Commitment Coordinator (N21)