ACCESSION NBR:9505220139 DOC.DATE: 95/04/30 NOTARIZED: NO FACIL:50-335 St. Lucie Plant, Unit 1, Florida Power
& Light Co.
50-389 St. Lucie Plant, Unit 2, Florida Power
& Light. Co.
AUTH.NAME AUTHOR AFFILIATION ROGERS,J.A.
Florida Power
& Light Co.
SAGER,D.A. 'lorida Power
& Light Co.
RECIP.NAME RECIPIENT AFFILIATION DOCKET 05000335 05000389
SUBJECT:
Monthly operating repts for Apr 1995 for St Lucie.W/950515 ltr.
DISTRIBUTION CODE:
IE24D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: Monthly Operating Report (per Tech Specs)
NOTES:
RECIPIENT ID CODE/NAME PD2-1 PD E
'HRR7 EXTERNAL: LITCO BRYCE,J H
NRC PDR i
COPIES LTTR ENCL 1
1 10 10 1
1 1
1 1
1 1
1 RECIPIENT ID CODE/NAME NORRIS,J AEOD/SPD/RRAB NRR/DISP/PIPB RGN2 NOAC COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 NOTE TO ALL"RIDS" RECIPIENTS:
PLEASE HELP US TO REDUCE iVASTE! CONTACfTIIE DOCUMENTCONTROL DESK. ROOM Pl-37 (EXT. 504-2083 ) TO ELliiIINATE YOUR NAME PROD!
DISTRIBUTIONLISTS FOR DOCUMENTS YOU DON"I'EED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 20 ENCL 20
P.O. Box 128, Ft. Pierce, FL 34954-0128 May 15, 1995 L-95-146 10 CER 50.36 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:
St. Lucie Units 1 and 2
Docket Nos.
50-335 and 50-389 Monthl 0 eratin Re ort Pursuant to Technical Specification 6.9.1.6, attached are the April, 1995, Operating Status and Summary of Operating Experience Reports for St. Lucie Units 1 and 2.
Should there be any questions on this information, please contact us.
Very truly yours, D. A.
ger Vice r sident St.
c e Plant DAS/PTQ cc:
Stewart D. Ebneter, Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, St. Lucie Plant Attachments 2208K'003 9505220i39 950430 an FPL GrouP company pDR ADpgK p5ppp335 R
t t
- p. $ "
I I
SUMMARY
OP OPERATING EXPERIENCE DOCKET NO UNIT:
DATE:
COMPLETED BY:
TELEPHONE'0-335 St. Lucie g1 May 15, 1995 Z.A. Rogers (407) 468-4157 Unit 1 operated at essentially full power for the entire month.
In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the PORVs or safety valves during the report period.
OPERATING STATUS OPERATING DATA REPORT DOCKET NO 50 - 335 DATE 5/ 8/95 FPL LICENSXNG GROUP - JUNO TELEPHONE 407/694/4432 1.
UNIT NAME:
ST.
LUCZE UNIT 1 2.
REPORTING PERIOD:
APRIL 1995 3.
LICENSED THERMAL POWER (MWT):
2700 4.
NAMEPLATE RATING (GROSS MWE):
850 5.
DESIGN ELECTRICAL RATING (NET 830 6.
MAXIMUMDEPENDABLE CAPACITY (GROSS MHL~
872 7.
MAXIMUMDEPENDABLE CAPACITY (NET MWE):
839
- 8. IF CHANGES OCCUR IN CAPACITY RATXNGS (ITEFI~MBER 3 THROUGH 7)
SINCE LAST REPORT, GZVE REASONS:
9.
I 10.
REASONS FOR RESTRICTIONS, ZF ANY:
MONTHLY
-YTD-CUMULATIVE
'1.
HOURS IN REPORT PERXOD:
12.
NUMBER OF HOURS REACTOR 13.
REACTOR RESERVE SHUTDOWN HOURS 14.
HOURS GENERATOR ON-LINE 15.
UNIT RESERVE SHUTDOWN HO 16.
GROSS THERMAL ENERGY GENERA 17.
GROSS ELECTRICAL ENERGY GENERATED (bSGg 18.
NET ELECTRICAL ENERGY GENERATED (MWH) 19.
UNZT SERVICE FACTOR 20.
UNIT AVAILABILITYFA 21.
CAPACITY FACTOR (USING MD 22.
CAPACITY FACTOR (USING DER NET 23.
UNIT FORCED OUTAGE RATE 24.
SHUTDOWNS SCHEDULED OVER 719 719.0 0.0 719.0 0.0 1944432 643620 611582 100.0 100.0 101.4 102.5 0.0 2879 2659.6 0.0 2652.2 0.0 7117169 2363530 2241282
- 92. 1 92.1 92.8 93.8 0.0 160919.0 125983.4 205.3 124609.0 0.0 322850910 106513540 100678185 77.4 77.5 76.8 76.2 3.9 25.
XF SHUT DOWN AT END OF REPORT PERIODS ESTIMATED DATE OF STARTUP:
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO ~
UNIT0 DATE COMPLETED BY:
TELEPHONE:
50-335 St. Lucie g1 May 15, 1995 J'+Ac ROGERS (407) 468-4157 DAY 4/01/95 4/02/95 4/03/95 4/04/95 4/05/95 4/06/95 4/07/95 4/08/95 4/09/95 4/10/95 4/11/95 4/12/95 4/13/95 4/14/95 4/15/95 4/16/95 4/17/95 4/18/95 4/19/95 4/20/95 4/21/95 4/22/95 4/23/95 4/24/95 4/25/95 4/26/95 4/27/95 4/28/95 4/29/95 4/30/95 AVERAGE DAILY POWER LEVEL (MWe-Net) 850 849 851 850
, 851 851 851 850 851 848 849 849 849 849 848 849 849 849 849 851 851 850 854 857 856 853 852 852 851 850
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.:
50-335 UNIT NAME:
ST LUCIE UNIT 1 DATE:
May 15, 1995 COMPLETED BY: J.A.ROGERS TELEPHONE:
(407) 468-.4157 RRPORT MONTH ~A No.
Date Type Duration (Hours)
Reasons Method of Shutting Down Reactor Licensee Event Report
¹ System Code Component Codes Cause &Corrective Action to Prevent Recurrence Unit 1 operated at fullpower for the entire month.
F Forced S Scheduled Reason A - Equipment failure (explain)
B - Maintenance or Test C - Refueling D - Regulatory restriction E - Operator Training 8c License Examination F - Administrative G - Operational Error (Explain)
H - Other (Explain)
Method 1 - Manual 2 - Manual Scram 3 - Automatic Scram 4 - Continued 5 - Load Reduction 9 - Other (Explain)
Exhibit G - Instructions for Preparation of Data Entry Sheets Licensee Event Report (LER) File (NUREG4161)
Exhibit I - Same Source
SUMMARY
OF OPERATING EXPERIENCE DOCKET NO ~ :
UNIT:
DATE COMPLETED BY:
TELEPHONE0 50-389 St. Lucie g2 May 15, 1995 J.A. Rogers (407) 468-4157 Unit 2 operated at greater than 80 percent power until April 24 when the unit downpowered to approximately 90% for turbine valve testing.
On April 25 unit shutdown to replace the DEH power supply, with reactor remaining critical; the unit returned to full power by end of day.
In accordance with the requirements of Technical Specification 6.9.1.6, there were no challenges to the PORVs or safety valves during the report period.
OPERATZNG STATUS OPERATING DATA REPORT DOCKET NO 50 - 389 DATE 5/ 8/95 FPL LICENSING GROUP -
JUNO TELEPHONE 407/694/4432
- 1. UNIT NAME:
ST.
LUCZE UNIT 2 2.
REPORTING PERIOD:
APRIL 1995 3.
LICENSED THERMAL POWER (MWT):
2700 4.
NAMEPLATE RATZNG (GROSS MWE):
850 5.
DESIGN ELECTRICAL RATING (NET 830 6.
MAXIMUMDEPENDABLE CAPACITY (GROSS MHE):
882 7.
MAXIMUMDEPENDABLE CAPACITY (NET MWE):
839
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITE~MBER 3 THROUGH 7)
SINCE LAST REPORT, GIVE REASONS:
9.
10.
REASONS FOR RESTRICTIONS, IF ANY:
MONTHLY "YTD-CUMULATIVE 11.
HOURS ZN REPORT PERIOD:
12.
NUMBER OF HOURS REACTOR 13.
REACTOR RESERVE SHUTDOWN HOURS 14.
HOURS GENERATOR ON-LINE 15.
UNIT RESERVE SHUTDOWN HO 17.
GROSS ELECTRICAL ENERGY GENERATED (MWH) 18.
NET ELECTRICAL ENERGY GENERATED (MWH) 19.
UNIT SERVICE FACTOR 20.
UNIT AVAILABILITYFA 21.
CAPACITY FACTOR (USING MD 22.
CAPACITY FACTOR (USING DER NET 23.
UNIT FORCED OUTAGE RATE 24.
SHUTDOWNS SCHEDULED OVER Refueling October 2, 1995 719 719. 0 0.0 711.8 0.0 1901570 619900 586793 99.0 99.0 97.3 98.3 1.0 2879 2804.4 0.0 2793.1 0.0 7465004 2463070 2331767 97.0 97.0 96.5 97.6 3.0 102816.0 87072. 1 0.0 85660.1 0.0 222662545 73916780 69837647 83.3 83.3 81.9 82.3 6.8 25 IF SHUT DOWN AT END OF REPORT PERIOD g ESTIMATED DATE OF STARTUP
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.:
UNIT:
DATE'OMPLETED BY:
TELEPHONE0 50-389 St. Lucie g2 May 15, 1995 Z.A ROGERS (407) 468-4157 DAY 4/01/95 4/02/95 4/03/95 4/04/95 4/05/95 4/06/95 4/07/95 4/08/95 4/09/95 4/10/95 4/11/95 4/12/95 4/13/95 4/14/95 4/15/95 4/16/95 4/17/95 4/18/95 4/19/95 4/20/95 4/21/95 4/22/95 4/23/95 4/24/95 4/25/95 4/26/95 4/27/95 4/28/95 4/29/95 4/30/95 AVERAGE DAILY POWER LEVEL (MWe-Net) 841 838 840 840 842 839 839 839 838 834 833 831 830 830 828 828 829 828 830 830 831 829 837 824 265 845 844 842 841 840
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO.:
UNIT NAME:
DATE:
50-389 ST LUCIE UNIT 2 May 15, 1995 COMPLETED BY: J.A. ROGERS TELEPHONE:
(407) 468-4157 REPORT MONTH A ril 1
No.
Date Type Duration (Hours)
Reasons Method of Shutting Down Reactor'icensee Event Report System Code'omponent Codes Cause & Corrective Action to Prevent Recurrence 950425 7.2 B
N/A HA INSTRU Unit 2 offline for DEH power supply replacement.
F Forced S Schcdulcd Reason A-Equipmcnt failure (explain)
B - Maintcnancc or Test C - Refueling D - Regulatory restriction E - Operator Training ds License Examination F - Administrative G - Operational Error (Explain)
H - Other (Explain)
Method 1 - Manual 2 - Manual Scram 3 - Automatic Scram 4 - Continued 5 - Load Reduction 9 - Other (Explain)
Exhibit G - Instructions for Preparation of Data Entry Sheets Licensee Event Report (LER) File (NUREG4)161)
Exhibit 1 - Same Source