L-86-266, Special Rept:On 860405,while Performing Refueling Outage, Evidence of Tip Damage on Newer anti-reverse Rotation Device Pins Revealed.Caused by Misalignment of Access Plugs W/Ramp Surface.Pins Replaced W/Pins of Improved Design

From kanterella
(Redirected from L-86-266)
Jump to navigation Jump to search
Special Rept:On 860405,while Performing Refueling Outage, Evidence of Tip Damage on Newer anti-reverse Rotation Device Pins Revealed.Caused by Misalignment of Access Plugs W/Ramp Surface.Pins Replaced W/Pins of Improved Design
ML20210B168
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 07/08/1986
From: Woody C
FLORIDA POWER & LIGHT CO.
To: Grace J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
L-86-266, NUDOCS 8702090090
Download: ML20210B168 (3)


Text

...

p)

(

.. s

\\

v f

g, FLORIDA POWER 8. LIGHT COMPANY

' ' -

  • q I7 a. [} 5 JUL 818sa L-86-266 Dr. 3. Nelson Grace Regional Administrator, Region 11 U. S. Nuclear Regulatory Commission 101 Marietta Street, N.W. Suite 2900 Atlanta, Georgia 30323

Dear Dr. Grace:

(

RE: St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 Special Report on Reactor Coolant Pump Anti-Reverse Rotation Device Pins

\\

Inspector follow-up Item 335, 389/85-31-01 g As requested by NRC, attached please find, part 2 of the subject Special Report.

Very truly yours, C. O. Woo Group V' President Nuclear Energy COW /SAV/eh attachment cc:

Document Control Desk, USNRC, Washington, D.C.

Harold F. Reis, Esquire 8702090090 860708 gDR ADOCK 0500038$

PDR L

$'% ggoI PSI:1 PEOPLE.. SERVING PEOPLE

A s.

/

)

+

.,q

~. /

NRC SPECIAL REPORT EVENT SEQUENCE On 5 April 1986, St. Lucie Unit 2 shut down for a scheduled refueling An inspection of the ARRD pins in the RCP's revealed that there outage.

were no stuck pins. However, there was evidence of tip damage on some of the newer pins. Further investigation showed that the access plugs were misaligned with the ramp surface. With the access plugs not flush with the ramp, there will be sharp edges exposed.

The ARRD pins were replaced with pins of an improved design.

The new pins have an increased tensile strength and incorporate the chamfering of the pin tips. The access plugs were checked for proper alignment Lock tabs and bolts by Quality Assurance personnel during reassembly.

were installed to assure continued alignment.

Unit 2 returned to service on 5 June 1986.

DISCUSSION The ARRD consists of 36 pins housed in blind holes in the lower balance ring attached to the motor rotor. These pins are free to drop by gravity onto a stationary ratchet. Each pin has a molybdenum-disulfide impreg-nated tip (FERLONR) to minimize wear to the ratchet during startup and coastdown of the RCP.

When the motor starts, the ramps of the ratchet impact with and push the pins up into the rotating disk.

Between 75 to 100 RPM, the centrifu-gal force holds the pins in position and they no longer impact with the ramps. As the motor slows below 100 RPM, the pins drop and again impact with the ramps. When the motor stops, the pins engage to stop reverse rotation.

The pins are accessed by way of a removable access plug in the stationary The top of the plug is machined so as to be flush with the surface rotor.

of the stationary ratchet. The misalignment of the access plugs is believed to be the cause of the premature pin wear. With the access R

As the FERLON l

plug misaligned, there will be sharp edges exposed.

tip traverses the access plug, it will be damaged. Eventually, the l

FERLON tip damage is sufficient enough to allow metal contact between

[

The resulting tip mushrooming causes the pin l

the pin and the ratchet.

to stick in it's retaining ring.

The modifications to the pins and the access plug locking device should l

Both Unit 1 and Unit 2 ARRD pins will l

stop the premature pin wear.

Based on the results be checked during their next refueling outages.

l of those observations, a new pin surveillance interval will be evaluated.

i i

l l

N

)

p

.. v.

v v

SPECIAL REPORT TO NRC l

BACKGROUND During a St. Lucie Unit 2 outage on 31 August 1985, it was observed that the 2A2 Reactor Coolant Pump (RCP) had many of the anti-reverse rotation device (ARRD) pins stuck in their retaining ring. Further investigation revealed that the other RCP's also had stuck pins.

Observations of the stuck pins showed that the molybdenum-disulphide impregnated synthetic tips (FERLON R) were worn to the point that metal to metal contact between the pins and the backctop ratchet had occurred.

This metal to metal contact resulted in the pins mushrooming and eventually wedging in their retaining ring.

The ARRD pins were replaced and the Unit was returned to service on 7 September 1985. On 10 September 1985 the Unit was again in an outage due to a manual reactor trip. The ARRD pins were inspected during this outage, and again, a significant number were stuck. After a discussion with the RCP motor vendor, Siemen-Allis Engineering, a two part approach to solve the problem was agreed upon. New replacement pins were alter-nately exchanged with the existing ARRD pins. In addition, half of all the pins were modified. The bottom outer edge of the pins was cham-fered.

It was felt that this taper would reduce the mushrooming of the pins. Unit 2 was returned to service on 21 September 1985.

Lucie Unit 1 RCP's were inspected and observed to have similar ARRD St.

1985. The pins pin problems during the refueling outage in October, were reinstalled with chamfered tips.

For further information, see part one of this report submitted in January, 1986.

-~

-