L-86-203, Advises That Response to IE Bulletin 85-003 Re motor- Operated Valve Common Mode Failures During Plant Transients Due to Improper Switch Settings Will Be Submitted by 860525
| ML17342A612 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 05/15/1986 |
| From: | Woody C FLORIDA POWER & LIGHT CO. |
| To: | Grace J NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| References | |
| IEB-85-003, IEB-85-3, L-86-203, NUDOCS 8607230393 | |
| Download: ML17342A612 (2) | |
Text
F LOR IOA PQ'I'VF.R 5 LIGHT COMPAhJ Y g~15NN p
L-86-203 Dr. 3. Nelson Grace Regional Administrator, Region II U. S. Nuclear Regulatory Commission 101 Marietta Street N.W., Suite 2900 Atlanta, Georgia 30323 Re: Turkey Point Units 3 and 0 Docket Nos. 50-250 and 50-251 IE Bulletin 85-03
Dear Dr. Grace:
We are currently reviewing IE Bulletin 85-03 (Motor-Operated Valve Common Mode Failures During Plant Transients Due to Improper Switch Settings) as it applies to Turkey Point Units 3 and 0.
As discussed with your staff, to allow for thorough FPL review of the response requested by the bulletin we are planning to submit it by May 25, 1986.
Should you or your staff have any questions on this information, please contact us.
Very truly yours, C. O. Woody
,Group Vice President Nuclear Energy COW/SAY:de Attachment cc:
Harold F. Reis, Esquire USNRC Document Control Desk PNS-LI-86-157 PDR g
3 86054 5 8607'g 8
R ADOCK 05000250 PDR
I