L-84-163, Forwards Documentation of Resolution of Deficiencies Noted in 820930 SER Re Environ Qualification of safety-related Electrical Equipment,As Discussed W/Nrc During 840508 Meeting.Requests Ssers Be Issued

From kanterella
(Redirected from L-84-163)
Jump to navigation Jump to search
Forwards Documentation of Resolution of Deficiencies Noted in 820930 SER Re Environ Qualification of safety-related Electrical Equipment,As Discussed W/Nrc During 840508 Meeting.Requests Ssers Be Issued
ML17346A427
Person / Time
Site: Turkey Point  
Issue date: 07/12/1984
From: Williams J
FLORIDA POWER & LIGHT CO.
To: Harold Denton, John Miller
Office of Nuclear Reactor Regulation
References
IEB-79-01B, IEB-79-1B, L-84-163, NUDOCS 8407170439
Download: ML17346A427 (86)


Text

RSSULATORY+lFORNATION DISTRISUTION S'+EI1 (RIDS)

ACCESSION NBR;8407170439 DOC DATE: 8A/07/12, NOTARI'ZED:

NO FACIL:50-250 Turkey Point Planti Unit 3i Florida Power and Light C

50 251 Turkey Point.Planti Uni:t 0i Flor,ida Power and Light C

AUTH BYNAME AUTHOR AFFILIATION l<ILLIAMSiJ ~ N ~

Fl oride,Power 8 Light Co ~

RECIPO NAME RECIPIENT AFFILIATION DENTONiH,R.

Office of Nuclear Reactor Regulationi Director MILLER'

~ R ~

Operating Reactors Branch 3

SIZE:

NOTES'L 07/19/72 OLs04/10/73

SUBJECT:

Forwards documentation of resolution of deficiencies noted in 820930 SER re. environ qualification of safety related e'lectrical equ,ipment<as discussed w/NRC.during 840508 meeting,Re ests b

ERs be issued, DISTRIBUTION CODE:

0 S

C ES RECEIVED:LTR ENCL I

L'ITLE:

OR/Licensi g Submittal:

Equipment Qualification DOCKET ¹ 05000250 05000251 05000250 05000251 RECIPIENT ID CODE/NAME NRR ORB1 BC 12 INTERNAL: ELD/HOSE 12 IE FILE 09 NRR/DE/EQB 07

=06 G

F IL 04 COPIES LTTR ENCL 0

1 1

1 1

2 2

1 1

1 RECIPIENT ID CODE/NAME McDONALDiD 01 GC 13 NRR KARSCHrR NRR/DL D IR 14 NRR/DSI/AEB RGN2 COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 EXTlERNAL:

ACRS'RC PDR NTES 15 02 31 8

8 1

1 1

1 LPDR NSIC 03 05 1

1 1

TOTAL NUMBER OF COPIES REQUIRED:,LTTR 25 ENCL 24

<<s e

e u

BOX 14000, JUNO BEACH, FL 3340B FLORIDAPOWER 8( LIGHT COMPANY Mr. H.R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Attention: Mr. J.R. Miller, Chief Operating Reactors Branch 3

L-84-163 July 12, 1984 Gentlemen:

Re: Turkey Point Units 3 & 4 Docket No. 50-250- and 50-251 Environmental Qualification of Safety-Related Electrical Equipment On May 8,

1984, Florida Power and Light met with NRC personnel to discuss

'the resolution of deficiencies documented in the Safety Evaluation Report (SER) dated September 30, 1982 regarding the Environmental Qualification of safety-related electrical equipment at Turkey Point (PTP)

Units 3

& 4.

The SER contained

'a Technical Evaluation Report (TER), written by Franklin Research Center under contract to the

NRC, which identified environmental qualification deficiencies for safety-related electrical equipment at Turkey Point.

The purpose of this letter is to provide documentation of the resolution of these deficiencies as discussed with the staff at the May meeting.

Discussions also took place at the meeting regarding Florida Power and Light's general methodology for compliance with 10 CFR 50.'49, "Environmental Qualification of Electric Equipment Important to Safety for Nuclear Power Plants," paragraph's (b)('1), (b)(2),

and (b)(3).

A synopsis of the methodology for developing the list of equipment within the scope of paragraph (b)(l) is as follows.

In developing the list of equipment within the scope of Paragraph (b)(l),

all design basis events which could result in a

potentially harsh environment, including flooding outside the containment, were considered in identifying safety-related electrical

'equipment which was to be environmentally qualified.

A systems approach was used to ensure that all equipment exposed to the accident environment was considered for evaluation, even if such equipment had not been previously identified as safety-related (Class IE) or defined as an engineered safety feature.

In addition, equipment required to function in support of emergency operating procedures (EOPs) was also considered for evaluation.

A review of worst case design basis accidents was made and a list of Class IE safety-related electric equipment within the scope of Paragraph (b)(1),

10 CFR 50.49 has been developed.

I ai07l.7O<S9 840712

'.PDR. ADOCK 05000250 P

.PDR PEOPLE... SERVING PEOPLE

i I

Electrical equipment within the scope of paragraph (b)(2) includes non safety-related electric equipment whose failure under postulated environmental conditions could prevent satisfactory accomplishment of safety functions.

The methodology that was used to identify such equipment is summarized below.

A list was generated of safety-related electric equipment, as defined in paragraph (b)(1')

of 10 CFR 50.49, which is required to remain functional during or following design-basis Loss of Coolant Accident (LOCA) or High Energy Line Break (HELB)

Accidents.

The LOCA/HELB accidents are the only design-basis accidents which result in significantly adverse environments to electrical

'equipment which is required for safe shutdown or accident mitigation.

The list was based on reviews of the Turkey Point Final Safety Analysis Report (FSAR),

Technical Specifications, Emergency Operating Procedures, Piping and Instrumentation Diagrams (P&IDs),

and electrical distribution diagrams.

The elementary wiring diagrams of the safety-related electrical equipment identified per paragraph (b)(1) were reviewed to identify any auxiliary devices electrically connected directly into the control or power circuitry of the safety-related equipment (e.g.,'utomatic trips) whose failure

,due to postulated environmental conditions could prevent the required operation of the safety-related equipment.

The operation of the safety-related systems and equipment were reviewed to identify any directly mechanically connected auxiliary systems with electri;cal components which are necessary for the required operation of the safety-related equipment (e.g.,

cooling water or lubricating systems).

This involved the review of P&ID's component technical

manuals, and/or systems descriptions in the FSAR.

Non safety-related electrical circuits indirectly associated with the electrical equipment identified per paragraph (b)(1) by.

common power supply or physical proximity were considered by a

,review of the original Turkey Point electrical design including the use of applicable industry standards (e.g.,

IEEE, NEMA, ANSI, UL, and NECO and the use of properly coordinated protective relays, circuit breakers,

.and fuses for electrical circuit fault protection.

FPL does not differentiate between equipment which is safety-related and non safety-related equipment whose failure could prevent the proper operation of safety;related equipment.

If failure of a device can effect the function of safety-related'quipment, that device is included in the 10 CFR 50.49(b)(l) scope.

In some cases non-class IE equipment may be powered from a class IE source,

however, that equipment is designed to become isolated from the Class IE source should failure occur.

As a result, there were no items identified falling into the 10 CFR 50.49 (b).(2) scope.

To identify electrical equipment within the scope of paragraph (b)(3),

FPL evaluated existing system arrangements and identified equipment for the five types of variables defined in R.G.

1.97, Rev.

3.

A report outlining the results of the

review, schedules for modifications where necessary, and justification of deviations not requiring modification has been submitted to the NRC for approval.

Since the report is still under review by the

NRC, some of the equipment identified in the report has not been added to the 10 CFR 50.49 scope.
However, some of the equipment items jointly within the scope of NUREG 0737 and R.G.

1.97 have been included in the 10 CFR 50.49 scope.

When the R.G.

1.97 report and equipment lists contained therein have been finalized and accepted by the NRC, appropriate equipment not already in the 10 CFR 50.49 scope will be added in accordance with the R.G.

1.97 implementation schedule.

0!

P

During the

meeting, there was a

discussion regarding maintenance and surveillance of qualified equipment.

FPL is pursuing a

program to ensure that safety-related electrical equipment is maintained in its qualified condition.

In conclusion, we believe that Attachment 1 "Resolution for Specific Equipment Qualification Deficiencies" documents resolution of the deficiencies in the Safety Evaluation Report (SER) dated September 30, 1982.

We also believe that Turkey Point Units 3

& 4 can continue to operate without undue risk to the, public health and safety based on the JCOs provided in Attachment 2 ~

Per your

request, the current "10 CFR 50.49 List" is included as.

As discussed in the May 8 meeting, it is requested that supplemental SERs be issued to indicate that Florida Power and Light's Equipment Qualification

Program, as described in this letter, meets the r'equirements of 10 CFR 50.49 and that the deficiencies noted in the SERs dated September 30, 1982 are considered resolved.

Please contact us if you have any questions.

Very trul'y yours, J.W. Williams, Jr.

Group Vice President Nuclear Energy DLDM/mp

I iO

g/

L-84-163 ATTACHMENT 1 RESOLUTION FOR SPECIFIC EQUIPMENT QUALIFICATION DEFICIENCIES TURKEY 'POINT UNIT NOS.

3

& 4

I

23-Jun-84 fuR);Ex Pt)INI uttlTS 3t4 RESOLUllON FOR SPECIFIC EQUIPtlENI QUALIFICAfIONDEFICIEttCIES SORf BY IER ITEtl No.

Paoe fER NRC ITEN CATE60RY I

Il.a IA6 d A) hOY-3-535 hOV-3-536 h0V-4-535 hOV-4-536

8) hOY-3-8668 hOV-4-8668 COttPONENI'ESCRIPTION AN)) FUNCTION Lxnxtorque notarized valve operator.

A) Pressurxzer relief isolation valve

8) Sl to RCS hotleg isolatxan valve NRC DEFICIENCY

-Evidence of Qualxfxcatxan

-Adeouate Sxaxlarxtv

-Aging ltearadation

-Qualified Life or Replaceoent

-Peak Ieaperature

-Peak Pressure

-Duratian

-Prafile Enveloped

-Spray RESOLUI ION Have been replaced uxtn fully aualifxea Liaitorque actuators, tloaels StlB-888 and SHB-88.

Linxtarque Report 688456 applxes.

STAfUS Qualxfxea 2

ll.c hOY-3-744A hOV-3-7448 ttOV-4-144A tiOV-4-7448 Lxaxtoraue notarized valve onerator.

RCS inlet isolation valve

-Aging Vegradatxan

-Qualified Life ar Reoiaceaent Arrhenxus hethoaolagy used to address aaing degradatxon.

A qualxfxed life af 48 years has been deaonstrated.

Qualified II.a hOV-3-758 tiOV-3-751 tlOV-4-758 hOY-4-75l Lxaxtorque notarized valve operator.

RCS to RHR inlet isolation valve

-Evidence of Qualification

-Adequate Sioilarity

-Aging Degradatian

-Qualified Life or Repiaceaent

-Peak Ienperature

-Peak'Pressure

-Duration

-Prafxle Enveloped

-Spray Have been replaced uith fully qualified Lioitorque actuators, hodels ShB-888 and StlB-88.

Linxtorque Report 688456 applies.

Qualified 4

Il.c hOV-3-358 tiOY-4-358 Linxtarque notarized valve operator.

Eoergency horatian valve.

-Aging Degradatxon

-Qualified Life or Replaceaent Arrhenxus hethodolagy usea to adaress aging degradation.

A qualified lxfe af 48 years has been denanstrated.

Qualified 5

Il.c A) hOY-3-869 hOV-4-869

8) ho'Y-8788 Lxnitorque notarized valve operator.

A) Loop A 6 8 hotleg Sl valve 8)

HHSI puap transfer valve.

-Aging Vegradatxon

-Qualified Life ar Replaceaent Arrhenius hethodalagy used to address aging degradation.

A qualified life of 48 years has been denonstrated.

Oualxfxea

23-Jun-84 TURKEY POlNT UNITS 3)4 RESOLUTlON FOR SPECIFIC EQUIPtlENT QUALIFICATION DEFlCIENCIES SORT BY TER ITEtl No.

Page 2

IER NRC ITEn CATEGORY TAB s CONPONENT DES CRIP TIDN AND FUNCTlON NRC DEFlCIENCY RESOLUTION SIAIUS 6

ll.c tlOV-3-1411 tlOV-3-1412 tlOV-4-1418 NOV-4-1411 tlOV-4-1412 Lioitorque ootorxzed valve orerator.

Steao generator blowdown valves

-Agxnn Dearaaatxan

-Qualified Life or Replaceoent Ihe Lxoxtorque valve actuators have been re-Quaiifxea placed with Ralph Hiller axr actuators usxng tully qualxfied ASCO NP Serxes solenoid valves (Test Report AQS 21678/TR, Rev.

A) and NAnCO EA 188 lxoit s~itches liest Report QIR 185, Rev.

3) 7 ll.c tlOV-3-888A,tlOV-4-888A Lioxtorque ootarized valve operator.

hOV-3-8888,tlOV-4-8888 Cantaxnoent spray puop aischarge isolation valve

-Agxng Dearadatxon

-Qualified Life or Replaceoent Arrhenius tlethodology used to address agxng aegradation.

A qualifxed life af 48 years has been deoanstrated Qualified 8

Il.c A) tlOV-4-1483 tlOV-4-1485

8) hOV-3-1418 Lioxtorque notarized valve operator.

A) Stean stop valve to AFN puop

8) Steao aenerator blow-dawn valve

-Agxng Degradatxon

-Qualified Life or Replaceoent Dualxfxea A) Replaced by fully qualifxed Lxoitorque DC actuator.

Lioxtarque Test Report 8-8889 applxes.

8)

The Lxoitarque valve actuators have been re-placed wxth Ralph Hiller air actuatars usxng fully qualxfxed ASCO NP Serxes solenoid valves ITest Report AQS 21678/TR, Rev.

A) and NANCO EA 188 lioit switches lTest Report QTR 185, Rev.

3)

II.c A) nOv-3-1483 tlOV-3-1485

8) hOV-3-1484 tlOV-4-1484 Lioitorque ootarized valve operator.

Stean stop valves to AFM puops

-Aging Degraaatxon

-Qualifiea Life or Replaceoent A) Replaced by fully qualifxed Lxoxtorque DC Qualified actuator.

Lioitarque lest Report 8-8889 applies.

8) Arrhenius tlethodology used to address agxng degradatxon.

A qualifxed lake of 48 years has been deoonstrated.

18 Il.c tlOV-3-863A hOV-3-8638 nOV-4-863A nov-4-8638 Lioitorque aotorxzed valve operator.

RHR heat exchanger outlet replaceoent

-Agxng Degradatxon

-Qualified Life or Replaceoent Arrhenxus tlethodolagy used to address agxng degradation.

A qualifiea life of 48 years has been aeoonstrated Qualxfxed 11 ll.c nOV-3-868A nOV-3-8688 nOV-4-868A nov-4-8688 Lxoxtorque ootorxzea valve operator.

Contaxnoent sunp xsolation valve

-Aging Degraaatxon

-Qualxfied Life or Replaceaent Arrhenxus tlethadolagy used to address agxng degradatxon.

A qualifxed lxfe of 48 years has been deoanstrated.

Qualified

25-Jun-84 IURrEY fOINT UNITS Da4 RESOLUIION FOR SPECIFIC EQUIPNENI QUALIFICATION DEFICIENCIES SORT By IER ITEII No.

Page TER NRC IIEll CAIEBORY IAB s CONPONENT OESCRIPTION ANO FUNCTION NRC OEF ICIENC'I RESOLUTION STAfUS 12 ll.a NOV-5-866A NOV-5-866B llOV"4-866A llOV-4-8668 Liaitorque notorized valve operator.

Sl to RCS hotlen isolation valve

-Evidence of Qualification

-Adequate Siailarity

-Aging Oegradation

-Peak Teaperature

-Peak Pressure

-Duration

-Profile Enveloped

-Spray Have been replaced with fully qualified Linitorque actuators, Nodels S118-888 and SllB-88.

Liaitorque Report 688456 applies.

Qualified 13 ll.a Replaceaent llnside CINT)

NAtlCO Liait switch.

Valve position indication and control

-Aging Degradation

-Qualified Life or Replaceaent

-Stean Exposure Never installed.

Deleted 14 I.b Position indication for CV-3-288A CV+288e CV-3-288C CV-5-2819 CV-4-288A CV-4-2888 CV-4-288C NANCO Liait switch.

Provide CVCS valve position indication and control

-Evidence of Qualification Linii s~itches have been replaced by fully qualified NAllCO Iinit switches, Ilodel EA-188.

Test Report QIR-I85, Rev.

3 applies.

fhese licit switches have been fitted with qualified 'Conax" connectors.

Qualified IS l.b Position indication for CV-5-AIBA CV-5-BIBB CV-4-318A CV-4-BIBB NAliCO Liait switch.

f'rovide CVCS valve position indication and control

-Evidence of Qualification Liait switches have been replaced by fully qualified NANCO Iiait switches, tlodel EA-188.

fest Report QIR-IB5, Rev.

3 applies.

fhese linit s~itches have been fitted with qualified 'Conax'onnectors.

Qualified

23-Jun-84 TURKEY POIHI UNITS 364 RESOLUTION FOR SPECIFIC EQUIPHEN'I QUALIFICATION DEFICIENCIES SORT BY TER ITEN No.

Page 4

TER NRC TA6 0 I IEN CAlEGORY CONPONENT OESCRIPTIOH AND FUNCTION NRC DEFICIENCY RESOLUTIOH STATUS 16 Il.a POV-3-2684 POv-3-2685 POv-3-2686 POV-4-2685 POV-4-2686 HANCO Linit switch for positxon xndicatxon for POV valves xn aaxn stean svstea

-Adenuate Sxnxlarity Lxnxt switches have been replaced bv fully qualified NANCO Iiait swxtches, Nodel EA-188 serxes.

Test Renort QlR-185, Rev.

3 applies.

These lxnit switches have been fitteo wxth qualxfied "Conax'onnectors.

Qualxfxed 17

)I. a HCV-3-121 HCV-4-121 NANCO Liait s~itch for letdown

'harqino valve posxtion xnoicatxon

-Adequate Siailarity Liait switches have. been replaced by fully qualified HAHCO Ixnit switches, Hodel EA-188 serxes.

Test Report QTR-185, Rev.

3 applies.

These lxait s~itches have been fitted with qualified 'Conax'onnectors.

Qualifxed 18 I.b PCV-3-455C PCV-3-456 PCv-4-455C PCV-4-456 NANCO Linit swxtch for pressurizer PORV posxtion xndxcation and control

-Evidence of Qualification Lioit switches have been replaced by fully qualified NANCD Iinit switches, Noael EA-188 series.

Test Report QTR-185, Rev.

3 applies.

These Iioit switches have been fitted with qualified

'Conax'onnectors.

Qualxfied 19 I.b-Position indicatxon for POV"3-2681 POV-3-2683 POV-4-2681 POv-4-2683 SV-4-2819 NANCO Lxnit swxtch.

Provxde CVCS valve posxtion-xndxcation and control

-Evidence of Qualification Li~it switches have been replaced by fully qualified HANCO linit s~itches, Nodel EA-188 series.

Test Report QlR-185, Rev.

3 applies.

Ihese linxt s~itches have been fitted with qualifxed

'Conax'onnectors.

Qualified

23-Jun-84 IURrEZ POINT UNITS 314 RESOLUTION FOR SPECIFIC EQUIPNENT QUALIFICATION DEFICIENCIES SORT By TER ITE)I No.

Page 5

TER hRC ITE)i CATE6ORV COhPONENT DESCRIPTION AND FUNCTION NRC DEFICIENCy RESOLUTION STATUS Il.a CV-3-28)X),CV-3-2812 NANCO Lixxit switch for eaergencv CV-3-2814 cooling bypass valve position CV"4-2818,CV-4-2812 xndicatxon CV-4-2814

-Adequate Sxnx Iaritv Linit s~itches have been replaced by fully qualified NANCO Iioxt switcnes, Nodel EA-188 series for Unit 4.

Replacenent with fully qualified NANCD Ixnit s~itches, Noael EA-188 series will be coapleted for Unit 3.

Qualified Note 1

lest Report QTR-195, Rev.

3 applies.

21 Il.a Associated wxth:

HCV-3-121 HCV-4-121 Fischer electrxcai/pneunatxc transducer provides pneuwatic control sxgnal for HCV-121 in cheaical volune control systen

-Evidence of Qualification These Ixnxt switches have been fxtted with qualified 'Conax connectors.

Located xn an area where the only harsh paraaeter is radiation.

Radiation resistance exceeding snecified requxrenents desonstrated by aaterxal analysis.

Qualifxed 22 Il.a 3P211A 3P2118 3P211C 4P211A 4l'2118 4P211C Mestinghouse coaponent coolxng puap aotor

-Aging Degradatxon

-Qualified Life or Replacenent

-Radiation Arrhenxus nethodo)ogy used to address agxng degradation.

A qualified life of 48 yeaCs has been deaonstrated.

Radiatxon resistance exceeding specified requxreaents dexxonstrated bv aaterxal analvsis.

Qualified 23 ll.a A) 3V38A, 3v388, 3V38C,4V38A 4V388,4V38C 8) 3V3A. 3V38 3V3C.

4V3A

4V38, 4V3C Joy Nfg. Co.

A) Eaergency Cftll coolino fan aotor

8) Eaergency contaxnaent filter fan notor

-Adequate Siexlarxty

-Agxng Degradatxon

-Qualxfied Life or Replacenent

-Spray

-Radiation New qualification report 1-6))4 obtained fron Jov Nfg. Co. establxshes sxailarxty, addresses aging by testing using Arrhenius aethodology to establish 48 year qualified life. Resistance to spray and radiation denonstrated.

Qualified

23-Jun-84 TURKEY POINT UNITS 3H RESDLUTION FOR SPECIFIC EOUIPNENT QUALIFICATION DEFICIENCIES.

SORT BY TER ITEN No.

Paqe 6

TAG 8 IER NRC II'EN CAtEGORY 24 Il. a T286 CONPONENT DESCRIPI'ION AND FUNCTION Oavton Borac acid batch aaxer aotor NRC DEFICIENCY

-Evidence of Qualification RESOLUTION Not in 18CFR 58.4'7 scope.

Equapaent located an aald envaronaent.

STATUS Ifeieted 25 ll.a 3-P283A 3-P283B 4-f'283A 4-P283B Chea Puop boric acid transfer puup aotor

-Evidence of Qualification Not in IBEFR58.49 scope.

Equapaent located in aald envaronaaent.

Deleted 26 Il. a

3P215A, 3P215B
4P215A, 4P215B Nestanghouse Safety anJectaon puap Rotor

-Aging De'gradation

-Qualified Late or Replacenent

-Radiataon Arrhenaus methodology used to address aging degradation.

A qualified life of 48 years has been deuonstrated.

Radiation resistance exceeding specified requareaents deaonstrated by Iateriai analysis Qualxfied 27 II.a

3P218A, 3P2188
4P218A, 4P2188 Mestinghouse RHR pump eotor

-Aging Oegradatxon

-Qualified Life or Repiacesent

-Radiation Arrhenaus aethodologV used to address aging deqradation.

A qualified life of 48 years has been deoonstrated.

Radiation resastance exceeding specified requareoents deaonstrated bv aateriai analvsis.

Qualxfaed 28 II.a

3P281A, 3P2818, 3P281C
4P281A, 4P281B 4P281C westinghouse charging puap uotor

-Aging Degradation

-Qualified Life or Replaceaent

-Radiation Arrhenaus oethodoloqy used to address agxng degradation.

A qualified life of 48 years bas been deaonstrated.

Radiation resastance exceeding specified requareaents demonstrated by aaterxal analysis.

Oualafaea 2V II a 3P214A) 3P2148y

4P214A, 4P2148 Nestanghouse contaanoent spray puap Iotor

-Agxng Degradataon

-Qualxfied Life or Replaceuent

-Radiatxon Arrbenaus Iethodology used to address agang deoradataon.

A qualifaed life of 48 years has been deaonstrated.

Radiation resistance exceeding specafaed requxreaents also deaonstrated by enganeerang analysis.

Qualifxea

23-Jun-84 TURlEY POINT UNITS M4 RESOLUTION FOR SPECIFIC EQUIPttENT QUALIFICAI'IDNDEFICIENCIES SORT BY IER IIEtt No.

Page 7

IER NRC ITEN CAIESORY IAB 5 CONPONENT DESCRIPIIOH AND FUNCTION NRC DEFICIENCY RESOLUI ION STATUS 38 Il.a FS-3-1422 thru -1427 FS-4-1422 thru-1427 Ball Engxneerxng flow swxtch axr flow aonxtor

-Evidence of oualifxcation

-Agxng degradation

-Qualified life

-Radxatxon Swxtches have been replaced with fullv qualified flow switches, Hodel FR 72-4 aanufactured by Fluid Coaponents, Inc.

for Unxt 4.

Qualxfxed Replaceaent with fully qualified flow

switches, hodel FR 72-4 aanufactured by Fluxd Coaponents, Inc. will be coapleted for Unit 3.

Hate 1

FCI Report 788583 applies.

31 Il.a RD-3-II, RD-3-12 Tracer Labs Radiatxon detector CIHT RD-4-11, RD-4-12 air particle aonitor

-Evidence of itualifxcation Located xn an area where the only harsh paraaeter xs radiation.

Radiation resistance exceeding specified requxreaents deaonstrated by engineering analysis.

Qualified 32 II.a TE-3-3448 throuoh IE-3-34b3 TE-4-3448 through IE-4-34h3 COHAX teaperature eleaent (I/Et.

Provxde teaperature indication for contaxnaent ventxlatxon charcoal filter

-Evidence of Qualification Have been replaced with fully qualified Pyco RTDs.

Hodel I?2-4819-IBI)-8-12-6S.

Qualifxcatxon Oocuaentation:

Pyco Qualification Report No.

77B831.

These RIDs are fitted with fully qualified 'Conax'onnectors Qualified 33 II.a TE-3-4128,TE-3-412D Roseaount resistance teaperature detector TE-3-42?B.TE-3-42?D (RTD).

Provide RCS hotleg over-TE-3-4328,TE-3-432D teaperature trip sxgnal TE-4-4128,TE-4-412D TE-4-4228,TE-4-422D TE-4-4328.IE-4-43?D

-Evidence of Qualification

-Aging Degradatxon

-Qualxfxed Life or Replaceaent

-Profxle Enveloped

-Spray

-Functional Testing

-lnstruaent Accuracy kestinghouse NCAP-9157 xs the qualxfxcation docuaent providing evidence ot qualification.

Aging degradatxon addressed usxng regression analysxs based on Arrhenxus aethodology, and a qualified life of 48 years deaonstrated.

lest profile including cheaxcal spray exceeds postulated accxdent requxreaent.

Functional testing and instruaent accuracy satisfactorily addressed in test report.

Qualified

23-Jun-84 TURKEY POINT'NITS 344 RESOLUTION FOR SPEClFIC EQUlPNEHI QUALlFICATlOH DEFIClEHClES SORT O'I TER ITEN Ho.

Page 8

IER NRC IIEtl CATEGORY CONPOHENT DESCRIPT'10H AHD FUHCTIOH NAC DEFIC1ENCY RESOLUI 1 OH SIAIUS 34 ll.a IE-3-418 IE-3"428 IE-3-438 TE-4-418 IE-4-428

[E-4-438 Roseoount resxstance teopeiature detector XRTO).

RCS cold leg teoperature to recorder

-Evidence of Qualifxcatxon

-Agxng Degradatxon

-Qualifxed Life or Replaceoent

-Profxle Enveloped

-Spray

-Functxonal Testing

-lnstruoent Accuracv

-Radiatxon Have been reolaced uith PYCO Nodel 122-4838-84 x4.4>B-GS.

PYCO Test Report 778B31 dated 8-31-77 applxes.

Nanufacturer has a neo qualxfxcation prograo to address agxng prooleos.

Qualifxed 35 Il.a TE-3-413A, TE-3-413B TE-3-423A.TE-3-4238 TE-3-433A,IE-3-4338 TE-4-413A, IE-4-4138 IE-4-423A,TE-4-4238 TE-4-433A,IE-4-4338 PYCO resistance teoperature detector (RID).

Reactor coolant subcooling oargxn oonitor

-Adequate Sioilaritv

-Agxng Degradatxon

-Test failures and anooalies Have been replaced uxth PYCO Nodel 122-4838-84 Qualxfxen X4. IIB.GS.

PYCO Test Report 778831 dated 8-31-77 applxes.

Nanufacturer has ner qualifxcatxon prograo to address agxng probleos.

36 II. b IB-3115, IB-4115 Hoffoan Nfg. Co. Junctxon box.

Provide reference Junctxon for theroocouple teaperature eleoents xn CVCS

-Evidence of Qualifxcation Junction boxes have been reooved because of systei redesxgn to replace I/Cs uxth RIDs.

Deleted 37 Il. a I lC-188 Foxboro Teoperature transoxtter.

Control

-Evidence of Qualifxcatxon for borxc acxd solenoxd SY-188 Not in IBCFR58.49 scope.

Equxpoent located xn ox ld envxronoent.

Deleted 38 Il.a Fl-3-613A,FI 3-6138 Fischer 8 Porter Fino transoitter.

FT-4-613A,FT-4-6138 Provxde signal for cooponent cooling Hater heat exchanoer outlet flaw indxcatxon

-Adequate Sxoxlarity

-Aging Degradation

-Qualified Life or Replaceoent Have been replaced by fully qualifxed Roseoount Nodel 1153 Series 8 transoxtter.

Roseoount qualifxcatxon report 0

188825 applies.

Dualxfxed

23-Jun-84 tURKEY fOINt UNITS 364 RESOLUTION FOR SPECIFIC EQUIPNENT QUALIFICAtlON DEFIClENCIES SORt BY TER ITEN No.

Page 9

TER hRC ITEN CATE60RY TAS a CONPONENf DESCRIPl ION AND FUNCTION NRC DEFICIENCY RESOLUTION Sl AIUS 39 Il.b 48 II.b Ft-3-932 FT-3-933 Ft-4-932 Ft-4-933 FT-3-474,-415.

FT-3-484,-485 Fl'-3-494)-495.

FT-4-474,-475, FT-4-484,-485.

FT-4-494.-495 Fischer 6 Porter Flow transaitter.

Provide signal for indication of safety xn]ection (Hi head) flow to hot leg Fischer 6 Porter Flow transaitter.

Provide signal for indication of steaa flow xn aain steaa line

-Adequate Siailarity

-Aging Degradation

-Qualxfied Lite or Replaceaent

-Aging Siaulation

-Profile Enveloped

-Spray

-Subaeroence

-fest Failures and Anoaalies

-lnstruaent Accuracy

-Duration Nargin

-Adequate Siailarity

-Aging Degradation

-Qualifxed Late or Replaceaent

-Agxng Siaulation

-Radiation

-fest Failures and Anoaalies

-lnstruaent Accuracy Have been replaced by fully Oualified Roseaount Nodel 1153 Serxes D transaitter.

Roseaount qualificatxon report 4

D8388848 applies.

Have been replaced by tully qualified Roseaount Nodel 1153 Serxes D cransaitter.

Roseaount qualificatxon report 0

08388848 applies.

Qualifiea Qualified Il If.a 42 Il.b Ft"3-122, FT-3-685.

FT-3-943, Ft-3-948)

Ft-4-122) FT-4-685, FT-4-943).FT-4-948 LT-3-474,LT-4-474 LT-3-475)LT-4-475 LT-3-476,LT-4-476 LT-3-484,LI-4-484 Lt-3-485,LT-4-485 LT-3-486,.LT-I-486 L1-3-I94, Lt-4-494 Ll-3-495.LT-4-495, Ll"3-496,Lf-4-496)

Fischer 6 Porter Flow transaitter.

Provide signal for flow indication of charging puap, RHR and safety injection puap discharge flow Fischer I) Porter Level transaitter.

Nonitor steaa oenerator water level

-Adequate Sxaxlarity

-Agxng Degradation

-Qualified Life or Replaceaent

-Adequate Siailarity

-Aging Degradation

-Qualified Life or Replaceaent

-Aging Siaulation

-Profile Enveloped

-Spray

-Subaerqence

-fest Failures and Anoaalxes

-Instruaent Accuracy Have been replaced by fully qualified Roeaount Nodel 1153 Series 8 and D

transaitters.

Roseaount qualification Reports D8388848 and 188825 applies.

Have been replaced by fully qualified Roseaount Nodel 1153 Series D

transaitters.

Roseaount qualification report D8388848 applies.

Qualified Qualified

23-Jun-84 TURKEY POINT UNITS 344

=

RESOLUTION FOR SPECIFIC EQUIPNENT QUALIFICATION DEFICIENCIES SORT BY TER IIEti No.

Page 18 IER NRC ITEtt CATEGORY TAS a CONPONENT DESCRIPT'ION AND FUNCTION NRC DEFIClENL'Y RESOLUTION STATUS 43 I.b LI'-3-459 Lf 3-468 LT-3-4bl Ll-4-459 LT-4-4bB LT-4-4II Barton Level transnitter.

Safety xnjection initiation, Clhf isolation

-Adequate Siox larity

-Aging Oegraaation

-Qualified Late

-Aoing Sinulation

-Spray Have been replaced with Rosenount Nodel 1153 Series D transaxtters.

Roseoount qualification report 08388848 applies Qualified I.b LS-3-1578 LS-3-1571 LS-4-1578 LS-4-1571 Naonetrol Level switch.

Provxde inaxcation of Cllll soap level

-Evidence of Qualxfication Have been replaced by tully qualifxed 6en Level Switches, Nndel 1854854.

Mvle Laboratorxes fest Rebort 45788-1 applies.

The level s~itches nave been fitted with fullv qualifxed 'Conax'onnectors.

Qualified Il.c I.C-181 Unitea Electric Controls Level controller.

Neasures level of hatching tank

-Aging Degradation

-Qualified Life or Replaceaent Not in 18CFR58.49 scope.

Equxpnent located in wild environaent Deletea 4f Il.b PT-3-455 PT-3-45b PT-3-457 Pl-4-455 Pf-4-456 Pl-4-457 Fxscher I Porter f'ressure transaitter.

Provide pressurizer pres'sure xndicatxon

-Adequate Sinxlarxty

-Aging Degradation

-Qualified Life or Replaceaent

-Aging Sxauiatxon

-Profile Enveloped

-Spray

-Subaergence

-Test Failures,and Anooaixes

-Instrunent Accuracy

-Duration l1argxn Have been replaced by fully qualified Roseaount Nodel 1153 Series D

transaxtters.

Roseaount Qualification Report No. D8388848 applxes Qualified

23-dun-84 TURKEY POINT UHITS 314 RESOLUTIOH FOR SPECIFIC EQUIPNENT QUALIFICAIIONDEFICIENCIES SORT BY TER ITEN No.

Page ll IER NRC ITEN CATEGORY CONPONEN I'ESCRIPTION AND FUNCTION NRC DEFICIENCY RESOLUTIOH STATUS Pl-3-483 Pl-4-483 48 ll.b PT-3-485 PT-4-485 Fischer I Porter Pressure transaitter.

Provide reactor coolant pressure indication Fischer 4 Porter Pressure transnitter.

Provide reactor coolant pressure indication

-Adequate Siailarity

-Aging Degradation

-Qualified Life or Repiaceaent

-Aging Siaulation

-Profile Enveloped

-Spray

-Subaergence

-fest Failures and Anoaalies

-lnstruaent Accuracy

-Duration Nargin

-Adequate Sinilarity

-Agino Degradation

-Qualified Life or Replaceaent Have iIeen replaced by fully qualified Roseaount Nodel 1153 Series D

transaitters.

Roseaount Qualification Report No. 08388848 applies Nave been replaced by fully qualified Roseaount Nodel 1153 Series 0

transaitters.

Roseaount Qualification Report Ho. 08388848 applies Qualified Qualified 49 Il.a 58 1 I.b PI-3-474, PT-3-476, PT 3-466)

PT-3-484, Pl-3-48n, PT-3-495)

PT-4-474, PT-4-476, PI-4-466, PT-4-484)

PT-4-486, PT"4-495, PI-3-484 PI-3-486 PT-4-484 Pl-4-486 PT-3-475, PT-3-464.

PT-3-468, PT-3-485'l-3-494, Pl-3-496, Pl-4-475, Pl-4-464, PT-4;468t PI-4-485, PT-4-494>

PT-4-496 Fischer 6 Porter Pressure transaitter.

Provide aain stean pressure indication Roseaount Pressure transnitter.

Provide signal for reactor coolant subcoolino aargin aonitor

-Adequate Siailarity

-Aging Degradation

-Qualified Life or Replaceaent

-Qualified Lite or Replaceaent

-Test Failures or Anoaaiies Nave been replaced by fully qualified Roseaount Nodel 1153 Series D

transaitters.

Roseaount Qualification Report No. 08388848 applies Have been replaced by tully qualified Roseaount Nodel 1153 Series 0

transaitters.

Roseaount Qualification Report No. 08388848 applies Qualified Qualified

25-Jun-B4 TURkEY POINT UNITS 364 RESOLUTION FOR SPECIFIC EQUIPNENT QUALIFICATION DEFICIENCIES SORI'Y TER ITEN No.

Page 12 IER NRC ITEN CATEBORY TAG d CONPONENT DESCRIPTION AND FUNCTION NRC DEFICIENCY RESOLUI'ION

'TATUS 51 Il.c PS-3-?BIA PS-5-281B PS-3-28IC PS-4-281A f'S-4-2818 PS-4-281C United Eectric Controls Pressure switch.

Provides interlock in the charning puap control

-Aging Denradation

-Qualified Life or Replaceaent Arrhenius aethodologv used to address aging degradation.

A qualified life of 48 years has been deaonstrated with periodic replaceaent of elastoaers Qualxfied S2 Ill.b PS-3-2887,PS+2888 PS-3-2889,PS-3-2858 PS-4-2887,PS-4-2888 PS-4-2889,PS-4-2856 PS-4-2857,PS-4-2858 Static 0 Ring Pressure switch.

'Pressure si xtch for containaent pressure None Not in 18CFR58.49 scope; Located in a ai ld environaent Deleted 55 Il.a PC-957A, PC-957B, PC-957C, f'C-9S7D Barton Pressure controller.

Interlock

-Evidence of Qualification for safety xn)ection puap control Located in an area where the only harsh paraaeter is radiation.

Radiation resistance exceeding specified requireaents deaonstratea by engineering analysis Qualified 54'l.c PC-3-611 PC-4-611 United Electrxc Controls f'ressure controller.

Provide interlock to coaponent coolxng water puap aotor

-Aging Degradation

-Qualified Life or Replaceaent Arrhenius aethodology used to address aging degradation.

A qualified life of 48 years has been deaonstrated with periodic replaceaent of elastoaers Qualified 55 Il.c PC-3-681 PC-4-688 United Electric Controls Pressure controller.

RHR puap discharge pressure indication and interlock

-Agxng Degradation

-Qualified Life or Replaceaent Arrhenius aethodology used'to address aging degradation.

A qualified life of 48 years has been deaonstrated with periodic replaceaent of elastoaers Qualified 56 Il.c PC+688 PC-4-681 United Electric Controls Pressure controller.

RHR puap discharge pressure indication and interlock

-Aging Degradation

-Qualified Life or Replaceaent Arrhenius aethodology used to address aging degradation.

A qualified life of 48 years has been deaonstrated with periodic replaceaent of elastoaers Qualified

23-Jun-BC TURKEY POINT UNITS 3H RESOLUTION FOR SPECIFIC EQUIPNENT QUALIFICAllONDEFICIENCIES SORT BY TER IIE)1 No.

Page 13 TER

.NRC ITEN CATESORY CONPONENT DESCRIPTION

'ND FUNCTION NRC DEFICIENCY

-RESOLUTION STATUS 57 Il.a Pl-3-948, PT-3"943, PT-4-948, Pl-4-943 Fischer fc Porter f'ressure transaitter.

)lonitor safetv injection pressure

-Adequate Sxuilaritv

-Agxng Degradation

-Qualiffed Life or Replaceaent Have been replaced by fully aualxfxed Roseaount

)lode) 1153 Series B

transaitters.

Roseaount Qualifxcatian Report 188825 applies Qualxfxed, 58 Il.a OPS-3-2988 DPS-3-2981 DPS-3-2982 OPS-4-2988 OPS-4-2981 OPS-4-2982 Barton Differential pressure s~itch.

Provide signal far differential pressure across feedwater control valve

-Evidence of Qualificatian Located xn an area where the only haish parameter xs ataaspherxc saturated steaa whxch xs excluded frau the switch xnternal by conduxt connections that extends beyond the area affected by steaa Qualified 59 Il.a Zl/ZS-3-6383A ZT/ZS 3-6383B Zl/ZS-3-6383C ZT/ZS-4-6383A ZT/ZS-4-63838 Zl/ZS-4-6383C Tech. for Energy Corp. Acoustic

. aonxtor.

Safety valve acoustic oonitorxng svstea

-Aging Degradation

-Peak

'TeIperature

-Test Faxlures and Anoaaixes Nxth the additxon of new cable asseablies and a transient shield to protect the charge aap)ifxers, test failures and anoualxes have been corrected, and operation at peak teuperature deianstrated Qualxfied 68 II. a 3N1418 3N1411 3N1412

'4N1412 REES Cantral station.

Local control for Iotar operated steaa generator blowdown valves

-Evidence of Qualifxcatxon

-Aging Degradation

-Qualified Life ar Replaceuent

-Steaa Exposure Not xn 18CFR58.49 scape.

This equxpaent has been deleted as a result of systea redesxgn Deleted 61 Il.c A) 3N215A 3N215B 4N215A 4N215B B] )lUV-CN)418

)IOt/-CNI4 II REES Lacal control statxon.

Provxde local control of safety xnJectlon puca

-Aging Degradatxon

-Qualifxed Life or Replaceaent A) Arrhenxus methodology used to address agxng degradatian.

A qualified life of 48 years has been deaonstrated wxth perxadxc replaceaent of elastoaers B) Not in 18CFR58.49 scope.

Thxs equxpaent has been deleted as a result of systeu redesxgn Qualxfxed Deleted

0

2Hun-84 tURKEY POINT UNITS 3h4 RESOLUI'IOH FOR SPECIFIC EQUIPNENT QUALIFICATIOR DEFICIENCIES'ORT BY TER ITEN No.

Page 14 TER NRC ITEN CATE60RY TA6 8 CONPOHENT DESCRIPTION ANO FUNCTIOH, HRC DEFICIENCY RESOLUTION SIATUS b2 II.c 3H218A 4N218A 4H2188 REES Local control statxon.

Provxde local control of RHR puaps

-Agxng Deoradatxon

-Qualifxed Life or Replaceaent Not.xn 18CFR58.49 scope.

Equxpaent located in ai ld envxronaent.

Deleted b3 II.c 3N211A 3N211B 3H211C 4H211A 4H211B 4H211C REES Local control station.

Provxde local control of coaponent cooling water puaps

-Agxng Degradation

-Qualified x.ife or Replaceaent Not in 18CFR58.49 scope.

Equxpaent located xn aild envxronaent.

Deleted 64 II.c N286 3H?83B 3N283A 4N283B 4N"83A REES Local control statxon.

Provide local control of boric acid transfer puap

-Agxng Degradation

-Qualxfied lite or Replaceaent Arrhenius aethodology used to address agxng degradatxon.

A qualifxed life of 48 years has been deaonstrated wxth perxodic replaceaent of elastoaers Qualitied 65 II.c 3N281A,3N2818.

3N281C 4N281A, 4H281B, 4N281C REES Local control station.

Provide local control of chargxng puaps

-Aging Degradation

-Qualified Life or Replaceaent Arrhenius aethodology used to address agxng degradation.

A qualifxed lite of 48 years has been deannstrated with perxodxc replacenent of elastoaers Qualified be Ill.b

TB3381, TB4372
TB4371, TB4368 Terainal hox xnsxde CTtlT Hone Hot in-18CFR58.49 scope.

Not requxred to per-Deleteo fora a safety functxon or ~itxgate the con-.

sequences of a desxgn basxs accxdent.

Bores are vented to prevent collapse durxng pressure transxents.

Fully qualxfied Raychea protected wxre splxces are aade inside the boxes to provide additxonal envxronnental protectxon

23-Jun-84 TURKEY POINT UNITS 3&4 RESOLUTION FOR SPECIFIC EQUIPNENI QUALIFICATION DEF ICIENCIES SORT BY IER IIEtl No.

Page 15 IER NRC I IEtl CAIEGOR'I TAB b COtlPONENT DESCRIPTIOH AND FUNCTION NRC DEFICIENCY RESDLUT IOH STATUS 67 Ill.b

183213, 183135
183158,

'183867 184158.

184135 184867 Terainal box inside CIhT spray puap rooa Hone Not in 18CFR58.49 scone.

Hot required to per-form a satety tunction or axtigate the con-sequences of a design basis accident.

Boxes are vented to prevent collapse during pressure transients.

Fully qualified Raycheu protected wire splices are aade inside the boxes to provide additional envxronaental protection Deleted 68 111. b

183145, 183143 184145'84143 Ieraxnal box inside CltlT Hone Hot in IBCFR58.49 scope.

Hot requxred to per-Deleted fora a safety function or eatigate the con-sequences of a design basas accaaent.

Boxes are vented to prevent collapse during pressure transients.

Fully qualified Raychea protected wire splices are aade xnsade the boxes to provide additional envaronaental protection 69 Ill.b 183144

184144, 184389 Terainal box inside CTtlT Hone Hot in IBCFR58.49 scope.

Hot requxred to per-Deleted fora a safety function or aitigate the con-sequences of a design basis accident.

Boxes are vented to prevent collapse during pressure transients.

Fully qualifxed Raychea protecteo wire splices are aade inside the boxes to provide additional envaronaental protectaon 78 Ill.b 183383

184379, 184367 184369 Terainal box ansade CItl1 None Not in IBCFR58.49 scope.

Not required to per-Deleted fora a safety function or uxtigate the con-sequences of a design basis accadent.

Boxes are vented to prevent collapse durxng pressure transaents.

Fully qualxfxed Raycheo protected ware splxces are wade inside the boxes to provxde additional envaronuental protectxon

23-Jun-84 TURKEY POINT UNITS 314 RESOLUTION FOR SPECIFIC EQUIPNENT QUALIFICATION DEFICIENCIES SORT BY TER ITEN Ho.

Page 16 TER NRC ITEN CATEBORY TAG b

CONPOHENT DESCRIPTIOH AHD FUNCTION NRC DEFICIENCY RESOLUTION STATUS 71 Ill.b

T83844, T83865
TB3134, TB3288
TB42118, 184134 T84844 Termxnal box xnsxde pxpe and valve room None Not in lBCFR58.49 scope.

Not requxred to per-Deleted form a safety tunctxon or aitiqate the con-sequences of a aesxgn basxs accident.

boxes.

are vented to prevent collapse durxno pressure transients.

Fully qualifxed Raychem protected wire splices are made xnsxde the boxes to provide additxonal envxronmental protectxon 72 Ill.b

TB3122, TB3123 T83124)'83125
T83126, TB3127
TB4122, TB4123-
TB4124, T84125
TB4126, T84127 Terminal box insxde CTlll None Hot in IBCFR5B.49 scope.

Not requxred to per-Deleted form a safety functxon or mxtiqate the con-sequences of a desxgn basxs'accxdent.

Boxes are vented to prevent collapse durxng pressure transients.

Fully qualifxed Raychem protected wxre splxces are made xnsxoe the boxes to provxde additxonal envxronaental protectxon 73 Il.a Varxous Termxnal box.

Provide local termxnatxon facxlity in varxous plant areas

-Evidence of Qualxficatxon Not in ISCFR58.49 scope.

Not required to per-Deleted form a safety functxon or mxtxgate the con-sequences of a design basxs accxdent.

Boxes are vented to prevent collapse durxng pressure transxents.

Fully qualxfxed Raychem protected wire splices are made inside the boxes to provxde additional envxronmental protectxon

23-Jun-84 TURKEY POINT UNlTS MI RESOLUTION FOR SPECIFIC EQUIPNENI QUALIF1CATlON DEFICIENCIES SORT DY TER llEN No.

Page 17 TER HRC IIE/I CAIEGORY TAG 8 CONPONENT DESCRIPTION AHD FUNCTION NRC DEFIClEHCY RESOLUTION STATUS 74 Il.a

T3P11, T3P12,
T3P22, I3PIls T3P42e T3P43.

13P51.

13P53, T3Cll,
13C12, T3C13, T3C21)
T3C22, T3C23, 13111,.

T3112.

13114, T3115,
T3121, 13122, 13123.

T3124 14f'12. TIP21,

14P22, IIP41, T4P42, T4P43.
14P51, 14f'52, 14Cll,
T4C12, 14C13, T4C21
TIC22, 14C23,
14112, 14114, TII15s 14121,
14122, 14123, 14124 Crouse-Hinds Containnent penetration asseably.

688 V power, control and instruaentation penetration

-Evidence of Docuaentation

-Adequate Siailarxty

-Aging Degradatxon

-Qualified Life or Replaceaent

-Teaperature/Pressure Criteria westinghouse report dated 8-11-72 provides docuaented evidence of qualification,

and, establxshes siailarity.

Arrhenius aethodology used to address agxng degradation and to establish a 48 year qualified lite.

Ieaperature/pressure test profile deaonstrated to be nore conservative than postulated accident paraaeters Dualifxed 75 ll.a SV-3-2818,SV-I-28]8 SV-3-2812, SV-4-2812 SV-3-2814,SV-4-2814 ASCO Solenoid valve.

Eaergency CTNT coolino bypass valve

-Evidence of Qualification

-Aging Degradatxon

-Qualified Lxfe

-Prograo for Aging Degradation

-Aging Siaulation Valves have been replaced with fully oualxfied ASCO NP series solenoid valves.

ASCO Test Report No.

AQS 21678/IR, Rev.

A applies Qualified 76 Il.a SV-3-2928 Ihru -2925 SV-4-2928 Ihru -2925 ASCO Solenoid valve.

Eaergency contaxnaent cooling water valves

-Evidence of Qualifxcation

-Aging Degradation

-Qualified Lake

-Prograa for Aging Degradation

-Agxng Siaulation Valves have been replaced with fully qualified ASCO NP series solenoid valves.

ASCO Test Report Ho.

ADS 21678/TR, Rev.

A 'applies Qualified 77 ll.c Various ASCO Solenoid valve ireplaceaent).

CVCS and CINT ventilation

-Qualified Life or Replaceaent Equipaent not used.

Deleted

0

23-Jun-84 TURKEY POINT UHITS 314 RESOLUTION FOR SPECIFIC EQUIPNENT'QUALIFICATION DEFICIENCIES SDRT BY TER ITE)l Ko.

Page 18 TER NRC ITEN CATEGORY TAB 0 CONPONENI OESCRIP IION AND FUNCTION NRC DEFICIENCY RESDLUTIOH S[ATUS 78 II.c SV-3-2911 Sv-3-2913 SV-4-2911 Sv-4-2912 SV"4-2913 ASCO Solenoid valve.

CTNT air aonxtorxng

-Agxng Degradation

-Qualified Life or Replaceaent

-Aging Degradatxon Prograa

-Aging Siaulatxon Agxng degradatxon, aging siaulation and qualified life, based on periodxc re-placeaent of elastoners established by an artificial (accelerated) aging progran based on Arrhenxus nethodology Qualifxed 79 II.a A) Sv"3-2684 Sv-3-2685-SV-3-268'9

, Sv-3-2618

  • SV-3-2615 SV-4-2684 SV-4-2685 SV-4-2689 SV-4-2618 SV-4-2614 SV-4-2615 ASCO Solenoid valve.

A) k1axn stean xsolation valve

-Evidence of Qualification

-Aging Degradation

-Qualified Life

-Agxng Pronran

-Aging Siaulatxon

, These valves have been replaced xxith fully qualified ASCO HP serxes valves.

ASCO Test Report Ho.

AQS 21678/IR, Rev.

A applies Qualified

8) SV-3-2988 SV-3-2982-SV-3-2984 SV-4-2988, SV-4-2982 SV-4-2984
8) Feedwater flou to stean generator, 88 Il.b SV-3-2681 Sv-3-2683 Sv-3-2884 SV-3-2))86 SV-4-2681.2683 SV-4-2884,2886 ASCO Solenoxd valve.

Contaxneent ventilatxon valves

-Evidence of Qualification Valves have been replaced by fully qualified ASCO soleno'id valves,

)lode)

NP series.

Qualification Report AQS 21678/TR, Rev.

A,. applxes Qualified

~ 23-Jun-84 TURKEY POIHI UNITS M(4 RESOLUTIOH FOR SPECIFIC EQUIPNEH'I QUALIFICATIOH DEFICIENCIES SORT BY TER lIEN Ho.

Page 19 TER NRC ITEN CATEGORY COIIPONEHT OESCRIPTIOH AND FUNCT ION HRC DEFICIENCY

  • RESOLUTIOH STATUS

.81 Il.a SV-3-2919 SV-4-2914 SV-4-2915 SV-4-2916 SV-4-2917 SV-4-291'7 ASCO Solenoid valve.

Auxiliary feeduater to steaa.

generator

-Evidence of Qualifxcatxon

-Aging Degraaatxon

-Qualified Life

-Aging Prograa

-Aging Sioulatxon These valves have been replaced uxth fully qualifxed ASCO NP series valves.

ASCO Test Report AQS 21678/IR, Rev.

A applies Qual xIx ed 82 ll.a SV-3-2986 Thru -2918 SV-4-2985 Ihru -2918 ASCO Solenoid valve.

Charcoal fxlter spray dousing valves

-Evidence of Qualification

-Aging Degradation

-Qualified Life

-Aging Prograu

-Aging Siauiatxon

-Spray These valves have been replaced with fully.qualifxed Target Rock Nodel 81AA-881 valves.

Target Rock Report 237SE applies.

Fully qualifxed COHAX seals have been xnstalled Qualified 83 Il.c SV-3-3789 SV-3-3713 SV-4-3789 SV-4"3713 ASCO Solenoid valve.

CTNT air eonxtorxng systea

-Aaing Degradation

-Qualified Life or Replaceaent

-Aging Degradation Prograo

-Aging Sxaulatxon Hot in IBCFR58.49 scope.

Equxpaent located in ai Id environaent Deleted

'4 Il.c Various ASCO Solenoid valve ireplaceaent).

CTNI purge air supply valves

-Qualified Life or Replacesent Hever xnstalled Deleted 85'l.c None 3NIElectro Products Electrxcal tape (outside containoentl.

Electrical insulation for conductor splices.

-Aging Degradation

-Qualified Lite or Replaceoent-Aging degradation addressed using regression analysis based on.

Arrhenxus aethodology.

A qualified life of 48 years nas been established Qualified 86 Il.a Hone ANPlNaychexx Electrxcal xnsulatxng sleeve.

-Documented Evidence Provide protection for field interface of cables at electrical penetratxon Hot in 18CFR58 F 49 scope.

Equipoent located in a axid environsent Deleted

23-Jun-84 TURKEY I'OINT UHll'S 3H RESOLUTIDN FOR SPECIFIC EQUIPNENT QUALIFICATION DEFICIENCIES SORl'Y TER ITEN No.

Page 28 TER NRC ITE)x CATEGORY TAB 0 CONPONENT DESCRIPTIOM AND FUNCTION HRC DEFICIENCY RESOLUTIOH STATUS 87 Il.c Hone Raychea RNF-188 Electrical insulating sleeve.

Provide insulation for in-line splices in penetration asseably

-Aging Degradatxon

-Qualxfied Life or Replaceaent Aging degradation addressed using re-gression analysis based on Arrhenius aethodology.

A qualified life of 48 vears has been established Qualified 88 ll.c None Ravchea NCSF-H Electrical insulating sleeve.

Provide protection for spliced conductors

-Aging Degradatxon

-Qualified Life or Replaceaent Aging degradatxon addressed using re-gression analysis based on Arrhenius aethodologv.

A qualified lite of 48 years has been established Qualified 89 ll.a Cable Codes:

N58 N52 HS3 N54 H55 N56 Okonite Electrical po~er cable.

Provide electrical power to various couponents

-Evxdence of Qualification A new qualification report, Okonxte Test Report H-I dated 7-3-78 addresses thereal aging, radxatxon exposure LOCA and Post LOCA exposure deaonstrating full qualifxcation Qualitied 98 Il.c 9l ll.c A) )XOV-3-867A NOV-3-8678 NOV-4-867A

))OV-4-8678

8) NOV-3-872 NOV-4-872 A) )10V-878A
8) NOV-3-843A NOV"3-8438

)XOV-4-843A NOV-4-8438 Lxaitoroue Notorized valve actuator.

A) Saran injection tank high head valve

8) Loop Ah8 hotleg safety in)ectxon stop valve Liuitorque Notorxzed valve actuator.

A) HNSI puaps transfer valve

8) Boron safety xn>ection systee

-Aging Degradatxon

-Qualified Life or Replaceuent

-Aqxng Degradation

-Qualifxed Life.or Repiaceaent Aging degradation addressed usxng regression analysis based on Arrhenius eethodoiogy.

A qualified life of 40 years has been establxsned Aging degradation addressed using regression analysis based on Arrhenxus uethodology.

A qualified lxfe of 48 years has been establxsned Qualified Qualified 92 ll.a Cable Codes:

)421,

N22, N23, N24, Okonite Electrxcal power cable.

Provide electrical power to various cooponents

-Agxng Degradation

-Qualified Life or Replaceaent A new qualification report Dkonxte Test Report N-I dated 7-3-78 addresses thereal aging, radxatxon exposure LOCA and Post LOCA Qualified

2S-Jun-84 TURkEY POINT UNITS Zh4 RESOLUTIOH FOR SPECIFIC EQUIPIIEHT QUALIFICATION DEFICIENCIES SORT BY IER ITEII Ho.

Page 21 IER NRC ITEN CATEGORy TAG a COIIPONENT OESCRIPI'ION AND FUNCTION NRC DEFICIEHCY RESOI.UT IOH STATUS H25.

N26 exposure aeaonstrating full qualifxcation

'0 Il.a Cable Codes:

Nxg H28 Okonxte Electrical power cable.

I'rovide electrxcal po~er to various coaponents

-Aqxng Degradation

-Qualified Life or Replaceaent A new qualification report Okonite Test Report N-I dated H-78 addresses theraal agxng, radiation exposure LOCA ano Post LOCA exposure deaonstrating full qualification Qualified 94 Il. a Cable Codes:

H7 Okonxte Electrical po~er cable.

Provide electrical po~er to various coaponents

-Aging Degradation

-Qualified Life or Replaceaent A new qualification report Okonite Test Report N-I dated 7-3-78 addresses theraal aging, radiation exposure LOCA and Post LOCA exposure deaonstrating full qualification Qualitied 95 Il.a Cable Code LIP Dekorad-Eaton Corp.

688 V instruaentation cable

-Adequate Siailarity

-Aging Degradation

-Qualified Life or Replaceaent Adequate sxailarity deaonstrated by certified test report and certificate of conforaance.

Aging degradation addressed using regression analysis based on Arrhenius aethodology to establish a

qualified life of 48 years Qualitied

'76 Il.a Cable Code:

N6 General Cable power cable.

Provxde electrical power to various coaponents

-Aging Degradation

-Qualified Life or Replaceaent Aging degradation addressed using re-gression analysis based on Arrhenius aethodologv.

A qualified life of 48 years has been established Qualified 97 Il.a Cable Code H77 Therao Electric Electrical theraocouple

-Evidence of Qualification cable.

Theraocouple extension cable.

Not in 18CFR58.49 scope.

These therao-couples have been replaced with RTOs and the cable has been deleted Deleted 98 Il. a Cable Code:

61 Contxnental Hire Co.

688 V instruaentation cable

-Evidence of Oualificatxon A new Contxnental report and suppleaent deaonstrate qualification by artificial aging using Arrhenius aethodology, xrradiation, LOCA and Post LOCA siaulation Qualitied

23-Jun-84 TURKEY POINT UNITS 3&4 RESOLUTION FOR SPECIFIC EQUIPBENT QUALIFICATION DEFICIENCIES SORT BY TER ITE)) Ho.

Page 22 TER HRC ITEN CATEGORY TAG I COHPOHENI DESCRIPT ION AHD FUNCTION NRC DEFICIENCY RESOLUIION STATUS 99 1 I.a Cable Codes:

bl b2 General Electric.

bee V instruaentatxon cable

-Adequate Sxailari tv Adequate sxailarxty denonstrateo by certified test report and certxfxcate of conforaance to supplenent type test Qual ified 188 ll.a Cable Codes:

LP1 Lll Anaconda Electrical b88 V

xnstruaentatxon cable

-Aging Degradation

-Qualified Life or Repiaceoent Aging degradation addressed using re-gression analysis based on Arrhenius aethodology.

A qualified life of 48 years has been established Qualified 181 ll.a Cable Code:

Lll Rockbestos bee V

xnstrunentatxon cable

-Adequate Siax larity Qualification testing perforaed by Sandia Labs. deaonstrate cable is qualified.

Sandia Report NUREG/CR-2952/I of 2 applies Qualified 182

l. a Cable Cone:

BRC Brand-Rex Coaxial cable

-None Fully Qualified Qualifxea 183 ll.a FI-3-118 Fl-4-118 184 l.b A) SV-3-2819

8) SV-4-,AIBA SV-4-3188 Foxboro Flou transx)xiter.

Provides flou signal for flou to charging punp ASCO Solenoid valve.

Auxiliary feedrater to stean generator

-Evidence of Qualification

-Evidence'of Qualification Hot in 18CFR58.49 scope.

Equipxxent located in nild envxronaent Valves have been replaced

)xith fully qualified ASCO'NP Series valves.

ASCO Test Report No.

AQS 21678/TR.

Rev.

A applies Deleted Qualified

)85 I.b A) sv-3-29)4 SV-J-29)b

8) Sy-4-2819 ASCO Solenoid valve.

Auxiliary feedwater to steaa generator

-Evxdence of Qualification Valves have been replaced uith fully qualxfied ASCO HP Series valves.

ASCO lest Report Ho.

AQS 21b78/TR, Rev.

A applies Qualxfxed

23-Jun-84 TURKEY POINT UNITS 3H RESOLUTION FOR SPECIFIC EQUIPNENT QUALIFICATION DEFICIENCIES SORT BY TER ITE)1 No.

Page 23 TER NRC ITE)x CATESORY TAG s CONPONEHT DESCRIPTIOH AHD FUNCTION NRC DEFICIENCY RESOLUTION STATUS 186 lob A) Sv-3-2985 B) SV-4-288A SV-4-288B SV-4-288C A) ASCO Solenoid valve.

Charcoal filter spray dousxng valves B)

ASCO Solenoid valve.

RCS Letdoun xsolatxon A) Agxnn Degradation, Qualified Life, Agxng Prograa.

Agxng Sxaulation

8) Evidence of Qualification A) Valves have been replaced Nxtn fully qualified Target Rock Nodel BIAA-881 valves.

Target Rock Report 237SE applies.

Fully qualxfied CONAX seals have been xnstalled

8) Valves have been replaced Nxth fully qualifxed ASCO NP Serxes valves.

ASCO Test Report No.

AQS 21678/TR, Rev.

A applies Qual xIx ed 187 A)II. a A) SV-3-318A B) I.b

8) POV-4-2684aLS A)

ASCO Solenoid valve B)

NANCO Liaxt suxtch Reactor coolxng systea chargxng lxne A) Evidence of Qualification B) Stean Exposure A) Valve has been replaced uxth fully qualified ASCO solenoid NP series valve.

ASCO Test Report No.

AQS 21678/TR, Rev.

A applxes B) Snitch has been replaced uith fully qualifxed EA188 Series Ixnit suitch.

HANCO Test Report QTR 185, Rev.

3 applies Quaiifxeo Qualxfxed 188 A) Il.b A) SV-3-288A B) I.a SV-3-2888 SV-3-288C

8) CV-4-28)2aLS A)

ASCO Solenoid valve B)

NA/)CO Lxait shxtch Reactor coolant systea letdown xsolation A) Evidence of Qualificatxon B) Hone A) Valves have been replaced xxith fully qualified ASCO NP series solenoxd valves.

ASCO Test Report Ho.

AQS 21678/TR, Rev.

A applxes B) Fully qualified Qualified Qualified

23-Jun-84 TURKEY POIHT uHITS M4 RESOLUIION fOR SPEClflC EQUIP))ENT QUALIFICAIIOHDEFICIENCIES SORT BY TER ITEN ho.

Page 24 TER NRC IIE)i EATE6ORY TA6 s CONPONENT DESCRIPTION AND FUNCTIOH NRC DEFICIENCY RESOLUI )OH SthluS

)89 A) Il.a A) SV-3-2912 SV-.3-291S SV-3-2917

8) Il.c B) 4H214A 4N2)4B A)

ASCO Solenoid valve 8)

REES Pushbutton switch Auxiliarv feedwater to stean qenerator A) Evidence of Qualification

8) Aging Degradation, Qualified Life A) Valves have been replaced with fully qualified ASCO NP series solenoid valves.

ASCO lest Report No.

AQS 21678/tR, Rev.

A aoplies

8) Arrhenius aethodology used to address aging degradation.

A qualified -life of 48 years has been established, based on periodic replaceaent of.

e)astoaers

'ualitied Qualified 118 I.b SV-3-2918 ASCO Solenoid valve.

Auxiliary feedwater to stean generator

-Aging Degradation

-Qualified Life

-Aging Prooran

-Aging Siaulation Valves have been replaced with fully qualified ASCO NP series solenoid valves.

ASCO lest Report Ho.

AQS 21678/IR, Rev.

A applies Qualifiea ill I.b SV-3-3188 ASCO Solenoid valve.

Reactor cooling systea charnlnn line

-Evidence of Qualification Valves have been replacet) with fully qualified ASCO NP series solenoid valves.

ASCO Nf'eries Report Hn.

AQS 21678/IR, Rev.

A applies Qualified NOTE l.

k)II be replaced ouring the next Unit 3 refueling outaae presently scheduled to begin in )larch bf 1985.

ATTACHMENT 2 JUSTIFICATION FOR CONTINUED OPERATION OF COMPONENTS TO BE QUALIFIED

CATEGORY II.A Item No.

2O Limit Switch Identification No:

Assoc. W/CV-3-2810 (2 sw'itches)

Assoc. W/CV-3-2812 (2 switches)

Assoc. W/CV-3-2814 (2 switches)

I Function:

Provide position indication for emergency containment bypass control valves.

A~nal sis:

1)

Loss of Coolant Accident These limit switches are located outside of the containment in a room where radiation from post-accident recirculation constitutes the only harsh environment.

The devices have been qualified on a component basis for the radiation levels they will be exposed to in the event of a LOCA.

During normal operation the valves associated with these limit switches provide cooling water flow through the emergency containment fan cooling.

units by bypassing the full flow valve on the discharge line from each cooling unit.

A thermal aging study was performed to determine qualified lifetimes and components replacement intervals for these devices.

Namco Controls April 21, 1980 letter to Florida Power and Light identifies the age susceptible components in the device.

Of the components fundamental to the operation of the device, only one material had a qualified life of less than 40 years.

Utilizing Arrhenius techniques, it was determined that the subject Buna 'N'-Rings and gaskets have a qualified life of 3.25 years.

The results of this thermal aging study have been entered in the plant maintenance schedule.

The components are listed as maintenance items and will be replaced before their "end of life".

In the event of a LOCA, a safety injection signal will automatically open the full flow valves.

The bypass valves may be closed remotely and fail in the closed position.

The bypass valves are only required for containment isolation.

Until the limit switches are replaced with fully qualified limit

switches, operators willbe informed to close the bypass valves in the event of a LOCA once open indication is received on the full flow valves.

0 If the limit switches were to fail post-LOCA, closed indication should be provided to the operators before the harsh environment could have an adverse effect on them.

Once valve position is verified closed, the bypass valve will remain closed.

Until these limit switches are replaced by fully qualified limit switches, operators will be trained not to rely on emergency containment cooler bypass control valve position indication after valve closure is observed in the event of a loss of coolant accident.

0

CATEGORY II.A Item No. 20 Page 2 of 2 No significant degradation of a safety function or misleading information to the operator as a result of failure of the limit switches under the accident environment resulting from a design basis event will occur.

2)

High Energy Line Break As the limit switches are located outside containment and are only required for emergency containment cooling for postulated high energy line breaks inside containment, they will not be exposed to an accident induced harsh environment, and their operation will not be affected.

==

Conclusions:==

Interim operation of Turkey Point Unit No.

3 with the existing limit switches is )ustified for the following reasons:

a)

The only harsh environment parameter the limit switches are exposed to is radiation and the devices are qualified for those radiation levels.

b)

The limit switches will provide indication of bypass valve closure before the harsh environment could have an adverse effect on them.

c)

The limit switches would not be exposed to a harsh environment for postulated high energy line break accidents they are re-quired to mitigate.

CATEGORY II.A Item No. 30 Flow Switch Identification No:

FS-3-1422 FS-3-1423 FS-3-1424 FS-3-1425 FS-3-1426 FS-3-1427 Function:

Monitor Air Flow through Emergency Filter Units A~nal sis:

1)

Loss of Coolant Accident The emergency containment filters operate post LOCA to filter airborne radioactive particulates (principally iodine) out of the containment atmosphere.

A water dousing system is provided in case air flow is lost to,the filter because of a concern that the decay heat of collected radio-active particles may ignite the charcoal.

Each emergency filter has two air flow switches located in the airstream.'uring post LOCA conditions, the air flow switches alarm a loss of air flow in the filter. If an emergency containment filter fan motor should fail, resulting in loss of air flow, an interlock with the flow switches would initiate dousing of the charcoal filters following a time delay.

The primary, means of initiating dousing are the emergency charcoal filter temperature elements.

Each filter contains eight temperature elements.

If 0

any one of these indicates a temperature rise to 325 F, the operator is instructed to manually initiate dousing.

Until these flow switches are replaced with fully qualified flow switches, operators will be informed to rely solely on temperature element indication to initiate dousing of the charcoal filters instead of utilizing air flow indication.

No significant degradation of a safety function or misleading information to the operator as a result of failure of the flow switches under the accident environment resulting from a design basis event will occur.

2)

High Energy Line Break The emergency containment filters and associated equipment are not required following a high energy line break.

==

Conclusions:==

Interim operation of Turkey Point Unit No.

3 with the existing air flow switches is )ustified for the following reasons:

a)

The charcoal filter temperature elements provide the primary means of alerting the operator to initiate dousing of the charcoal filters.

Operators will be informed to rely on temperature element indication instead of air flow indication.

b)

The flow switches are not required in the mitigation of high energy line break.

ATTACHMENT 3 CURRENT 10 CFR 50.49 LIST

23-Jun-84 TURKEY POTNT UNlTS 2(4 STATUS OF HASTER 18CFR 58'9 LlST Page

)

TAS 8 TER ITEN COHPONEN 1 OESCRTPTlON AND FUNCTION STATUS 3N281A,3N281B.

3N281C 4N281A,4N2818, 4N281C 65 REES Local control station.

Provade local control of charging pueps Qualified 3N214A Hone Rees Local Control Stat<on Qualified 3N215A 3N2158 4N215A 4N215B 61 REES Local control station.

Provide local control of safetv iniectton punp Qualified 3821B Hone Rees Local Control Station Qualified

3P281A, 3P2818, 3P281C 4P281A.

4P281B 4P281C 28 Nesttnghouse chargtng punp notor Qual>fied

3P218A, 3P218B
4P218A, 4P218B 27 Nesttnghouse RHR punp aotor Qualified 3P211R 3P211B 3P211C 4P211A 4P2118 4P211C 22 Nestinghouse coeponent cooling puap notor Qualified
3P214A, 3P214B,
4P214A, 4P214B 29, westinghouse contatnaent spray puep eotor Qualified

23-Jun-B4 TURKEY POINT UNITS 3&4 STATUS OF NASTER 18CFR 58.49 LIST Paqe 2

TA6 0

[ER ITE)l CONPONENT DESCRIPTION AND FUNCTION STATUS 3P2)5Ae 3P2158

4P215A, 4P215B 2b Mestinghouse Safety in)ect)on puan

~otor Qualified A) 3v38A. 3V388, 3V38C,4V38A 4V388,4V38C B) 3V3A, 3V38

3V3C, 4V3A
4V38, 4V3C Joy Nfq. Co.

A) Eaergencv CT))T coo)ann fan aotor B) Eaergency contaanaent filter fan aotor Qualsf)ed Cable Code:

61 9B Continental Mire Co.

688 V )nstruaentat)on cable Qualified Cable Codes:

61 62 6eneral Electrxc.

688 V snstruaentatson cable Quali fi ed Cable Code:

BRC Position indacataon for CV-3-288A CV-3-2888 CV-3-288C CV-3-2B19 CV"4-288A CV-4-288B CV-4-288C 182

/

14 Brand-Rex Coaxial cable NANCO Lioit snitch.

Prov)de CVCS valve position and)cation and control Qualified Qualified CV-3-2818. CV-3-2812 CV-3-2814 CV-4-2B18,CV-4-2812 CV-4-2814 28 NANCO Liait snitch for eaergency cool)ng bypass valve position-indicatxon Unit 4 Qualified Unit 3 See Note I

23-Jun-BI TURKEY POINT UNITS 3III STATUS OF NASTER 18CFR 58.49 LIST Page 3

IAB I IER llEN CONPONENT OESCRIPIlON AND FUNCllON STATUS Positron snaacataon far CV-3-314A CV-3-3188 CV-I-314A CV-I-314B 15 NANCO Licit switch.

Provide CVCS valve posit)on tndicataan and control Qualifaed OPS-3-2944 OPS-3-2941 OPS-3-2942 OPS-4-2988 OPS-4-2981 OPS-4-2982 Barton Differential pressure switch.

Provide sagnal for differential pressure across feedwater control valve Qualified FS-3-1422 thru -142l FS-4-1422 thru-1421 34 Flusd Coenonents, inc. flaw switch for <<r flow eonitor Ball Engineering flow switch for,air flow monitor Untt 4 Qual>fied Unit 3 See Note l fT-3-122>>

F 1-3-685>>

Fl-3-913, Fl-3-948, F 1-4-122>>

FI"I-h85>>

fl-4-943>> FT-4-948 fI 3-174.-475>>

FT-3-4BI.-IBS F T-3-194>>-495>>

FI-H)4>>-ITS>>

fl-4-481>>-485>>

FI-H94, "495 Roseaount flaw transa] tter.

Provide stgnal for flaw indication af charging puep, RHR and safety anlect1on puep discharge flaw Roseeount flow transeitter.

Provide signal far indication of stean flow cn wain stean line Qualified Qualified

23-Jun-84 TURkE'f f'OINT UNll'S M4 STATUS OF NASIER 1BCFR 58.49 LIST Page TAS e TER ITEN CONPONENT DESCRIPTION AND FUNCTION STATUS F1-3-613A,FI-3-6138 38 FI-4-613A,FI-4-6138 Roseaount Flaw transaitter.

Provide signal for coaponent cooling rater heat exchanger outlet flow indication Qualified Fl-3-932 Fi-3-933 FT-4-932 FI-4-933 Roseaount Flou transoitter.

Provide signal for indication of safety injection IHi head) floe to hot leg Qualified HCV-3-121 HCV-4-121 17 NANCO Liait switch for letdown charging valve position indication Qualified Associated with:

HCV-3-121 HCV-4-121 21 Fisher electricai/pneuaatic transducer provides pneueatzc control signal far HCV-121 in cheoical voluae control systea Qualified Cable Code L1P Oekorad-Eaton Carp.

688 V instruaentatian cable Qualified Cable Codes:

LPI LII Anaconda Electrical 688 V

instruaentation cable Qualified LS-3-1578 LS"3-1571 LS-4-1578 LS-4-1571 44 Sea Level suitch.

Provide indication of CTHT suip level Qualified

0

23-Jun-84 TURKEY POINT UNITS 354 STATUS OF tlASIER IBCFR 58.49 LIST Page 5

IAG 8

= [ER IIEtl COhPONENI DESCRIPTION AND FUNCTION Sl'ATUS Ll 3-459

" LT-3-468 LI-3-461 LI-4-459 LI-4-468 LI-4-461 Roseaount Level transaitter.

Safety infection initiation,

.Clhi isolation Qualified LT-3-474,LT-4-474 LI-3-475,LT-4-475 L1-3-476,LT-4-476 LT-3-484,LI'-4-484 LT-3-485,LT-4-485 LT-3-486,LT-4-486 L1-3-494,LI-4-494 LT-3-495,LT-4-495.

LI-3-496)LT-4-496, Cable Code:

LI1 42 181 Roseaount Level transaitter.

tlonitor stean generator water level Rockbestos 688 V

instruaentation cable Qualified Qualified A] tlOV-3-1483 tlOV-3-1485

8) tlOV-3-1484 tlOV-4-1484 Liaitoroue aotorized valve operator.

Stean stop valves to AFN pueps Qualified hOV-3-14II hOV-3-141?

tlOV-4-1418 tlOV-4-1411 hoV-4-1412 ASCO solenoid valve.

.Stean generator blowdown valves Qualitied hOV-3-358 hOV-4-358 Li~itorque aotorized valve operator.

Eeergency boration valve Qualified

23-Jun-84 TURKEY POINT UNITS'364 STATUS OF NASIER IBCFR 58.49 LIST Page 6

TAB I TER ITEN CONPONENT DESCR IPIION ANO FUNCTION STATUS Al tlOV-3-535 NOV-3-536 llOV-4-535 llOV-4-536 Bl llOV-3-8668 NOV-4-&668 Lxaxtorque notorxzed v'alve operator.

Al Pressurxzer relief xsolatxon valve

8) Sl to RCS hotleg isolation valve Qualxfxed NOV-3"744A llOV-3-7448 llOV-4-744A tlOV-4-7448 Lieitorque aotorxzed valve operator.

RCS xnlet xsolatxon valve Qualxfied llOV-3-758 NOV-3-751 llOV-4-758 NOV-4-75I Liaitorque notorxzed valve operator.

RCS to RHR xnlet xsolatxon valve Qualified llOV-3-868A NOV-3-868e tlOV-4-&681 llOV-4-8688 Lxaxtorque eotorxzed valve operator.

Containnent suap xsolatxon valve Qualified NOV-3-8631 Il&V-3-Bb38 NOV-4-8631 II&V-4"8638 Lxextorque aotorxzed valve operator.

RHR heat exchanoer outlet replaceoent Qualified llOV-3-866A llOV-3-&668 NOV-4-866A llOV-4-8668 l2 Lxaxtorque aotorized valve operator.

SI to RCS hotleg xsolatxon valve Qualified

23-Jun-84 TURKEy POINT UNITS 3hI STATUS OF )IASZER 18CFR 58.49 LIST Page 7

TA6 4 TER LiEN CQNPONENT DESCR IP TION AND FUNCTION STATUS A) NDV-3-867A NOV-3-81 78 NDV-4-867A NQV-4-8678

8) NOV-3-872 NOV-4-872 Lieitorque Notorized valve actuator.

Al Boron inJection tank high head valve

8) Loop A) 8 hotleg safety inJection stop valve Qualified A) NDV-3-869 NQV-4-869
8) NQY-8788 Linitorque notarized valve aperatar.

A) Loap A fc 8 hotleg Sl valve 8)

HHSI puep transfer valve.

Qualified NOY-3-888A,NOV-4-888A NDV-3-8888,NOV-4-8888 Lie)torque notarized valve operator, Cantainaent spray puap discharae isolatian valve Qualified A) NDV-4-1483 NDV-4-1485 Al Linitarque notarized valve operator.

Stean stop valve to AFN puap Qualified

8) NDV-3-14)8 8)

ASCO salenoid valve.

Stean generator blow-down valve Qualified A) llQV-878A

8) NOV-3-843A NOV-3-8438 NQV-I-843A l10V-4-8438 91 Liaitorque tlotorized valve actuator.

A) HHSI punps transfer valve

8) Boron safety injection systea Qualified Cable Codes:

H)9 N28 93 Dkonite Electrical power cable.

I'rovide electrical power to various coaponents Qualified

23-Jun-84 tURKEY POINT UNITS 3H STATUS OF BASTER IBCFR 58.49 LIST Paqe 8

TAG'0 IER ITEN CONPONENT DESCRIPTION AND FUNCTION STATUS H28b 3N283B 3H283A 4N283B 4N283A REES Local control statxon.

Provide local control. of borxc acxd transfer puop Qualifxed Cable Codes:

N2l H22 N23 H24 H25 N24 92

-Okonxte Electrical power cable.

Provide electrxcal power to varxous coaponents Qualified Cable Codes:

N58 N52 N53 H54 N55 H56 Okonxte Electrical power cable.

Provxde electrical power to varxous conponents Qualified Cable Code:

. Nb General Cable power cable.

I'rovide electrical po~er to varxous conponents Qualifxed Cable Codes:

N7 Okonite Electrxcal power cable.

Provxde electrxcal power to varxous coaoonents Qualifxed None 3H/Electro Products Electrxcal tape xoutsxde contaxnaentx.

Electrxcal xnsulation for conductor solices Qualxfxed

23-Jun-84 TURKEY POlNT UNll'S 3&4 STATUS OF BASTER 18CFR 58.49 LIST Page IAG B TER ITEN CONPONENI DESCRlPTIOH AND FUNCTION STATUS None Ravchea RNF-188 Electrxcal xnsulatxng sleeve.

Provxde xnsulatxon for in-line splxces xn penetratxon assenbly Qualifxed None Raychee NCSF-N Electrxcal xnsulatxng sleeve.

Provide protectxon for solxced conductors Qualxfied PC-3-688 IC-4-681 56 Unxted Electric Controls Pressure controller; RHR puap discharge pressure xndxcation and xnterlock Qualifxed PC-3-681 PC-4-688 Unxted Electrxc Controls Pressure controller.

RHR punp dxscharge pressure xndicatxon and xnterlock Qualified PC-3-611 PC-4-611 United Electric Controls Pressure controller.

Provide xnterlock to conponent cooling water puap eotor Oualifxed PC-957A, PC-957B, PC-957C, PC-957D Barton Pressure controller.

Interlock for safety xngection puap control Qualified PCV-3-455C PCV-3-456 PCV-4-455C PCV-4-456 18 NANCO Licit s~itch for pressurxzer PORV positxon xndxcatxon and control Qualxfied

23-Jun-84 TURKEY POlNT UNlTS 31t4 STATUS OF BASTER lBCFR 58.49 LlST Page 18 TAO I I'ER ITEN CONPONENT OESCRlPTlON AND FUNCTTON STATUS Positxon xndication for POV-3-2a81 POv-3-2683 POV-4-2681

-POV-4-2683 SV-4-2819 19 NAXXCO Liait suitch.

Provide CVCS valve posxtion xndicatxon and control Oualifxed POV-3-2684 POV-3-2685 POV-3-2686 POV-4-2685 POv-4-?aBa 16 NABCO Liaxt sxxitch for position indicatxon for POV valves in aain stean systea Qualified PS-3-281A PS-3-281B PS-3-281C PS-4-281A PS-4-281B PS-4-281C 51 Unxted Electric Controls Pressure swxtch.

Provides xnterlock xn the chargxnq puap control Qualifxed PT-3-483 PT-4-483 47 Roseaount pressure transnitter.

Provxde reactor coolant pressure xndication Qualified PT-3-484 PT-3-486 PT-4-484 PT-4-48a Roseaount Pressure transaitter.

Provide sxgnal for reactor coolant subcoolxng eargxn aonitor Oualifxed Pl-3-485 Pl-4-485 48 Roseoount pressure transaxtter.

f'rovxde reactor coolant pressure indicatxon Qualxfxed

23-Jun-84 TURKEY PDINT UNITS 3H STATUS OF NASTER lBCFR 58.49 L]SI Paqe ll IAB 0 TER 1IEN CONPONENT DESCRlPTION AND FUNCl'lON STATUS Pl-3-455 Pi 3-456 PI-3-4S7 PI-H55

. PI-H56 Pl-4-457 PI-3-474, P1-3-476, P1-3-466.

P1-3-484.

P1-3-486, I'1-3-495, PI-4-474, PT-4-476, PI-4-466, PI-H84, PI-4-486, PI-4-495, PT-3-475, Pl-3-464, P1-3-468.

Pl 3-485, PT-3-494)

'T-3-496, PT-4-475, Pl-4-464, P1-4-468, PI-4-485, PI-4-494)

Pl+496 46 Roseaount pressure transaitter.

Provide pressuriaer pressure indication Roseaount pressure transaitter.

f'rovide aain steaa pressure indication Qualified 1

Qualified Pl-3-948) P1-3-943, PT-4-948, Pl-4-943 RD-3-11, RD-3-12 RD+ll, RD-4-12 A) SV 3-288A Sv-3-2888 SV-3-288C

8) CV-4-2812aLS 57 lBB Roseaount oressure transaitter.

'onitor safety injection pressure Tracer Labs Radiation detector CTNI air particle eonitor A)

ASCO Solenoid valve 8)

NANCO Liait switch Reactor coolant systea letdown isolation Qualified Qualified Qualified

23-Jun-84 TURKEY POINT UNITS 3&4 STATUS Of NASTER 18CFR 58.49LISI'age 12 TAG 0 TER ITEII CONPONENT DESCRIPTION AND FUNCTION STATUS SV-3-2681 SV-3-2683 SV-3-2884 SV-3-2886 SV-4-2681 SV-4-2683 SV-4-2884 SV-4-2886 ASCO Solenoid valve.

Contaxnaent ventilatxon valves Qualifxed A) SV-3-2684 SV-3-2685 SV-3-2689 SV-3-2618 SV-3-2615 SV-4-2684 SV-4-2685 SV-4-2689 SV-4-2618 SV-4-2614 SV-4-2615 ASCO Solenoxd valve.

Al haxn steaa xsolatxon valve Qualified

8) SV-3-2988 SV-3-2982 SV-3-2984 SV-4-2988 SV-4-2982 SV-4-2984 B) Feedwater flaw to steaxx generator Qualifxed SV"3-2614 None ASCO Solenoid Valve for

~axn stean xsolatxon Qualified

i

23-dun-84 TURKET POINT UNITS 354 STATUS DF NASTER 18CFR 58.49 LIST Page 13

[ER ITEN CONPONENT DESCRIPTION AND FUNCTION STATUS SV-3-2818.SV-4-2818 SV-3-2812,SV-4-2812 SV-3-2814.SV-4-2814 ASCO Solenoxd valve.

Energencv CTNT cooling bypass valve Qualxfxed A) SV-3-2819

8) SV-4-318A SV-4-318B 184 A) ASCO Solenoid valve. Auxiliary feeduater to stean generator 8)

RCS Charning line.valve Qualxfxeo A) SV-3-2985

8) SV-4-288A SV-4-2888 SV-4-288C 18b A) Target Rock Solenoxd valve.

Charcoal filter spray dousxng valves 8)

ASCO Solenoid valve.

RCS Ietdoun isolation Qualified SV-3-298b lhru -2918 SV-4-2985 lhru -2918 SV-3-2911 SV-3-2913 SV-4-2911 SV-4-2912 SV-4-2913 82 78 Target Rock solenoxd valve.

Charcoal filter spray dousxng valves ASCO Solenoxd valve.

Cl)ll axr aonxtorxnq Qualified Qualified A) SV-3-.2912 SV-3-2915 SY-3-2917 8) 4N214A 4N2148 189 A)

ASCO Solenoid valve 8)

REES Pushbutton swxtch AuxxIiary feedwater to steaa generator Qualified A) SV-3-2914 SV-3-291b

8) SV-4-2819 185 ASCO Solenoxd valve.

Auxxiiary feedwater to stean generator Qualxfxed

23-Jun-84 TURKEy POINT UNITS 3H STATUS OF NASTER 18CFR 58.49 LIST Page 14 TAB e TER ITEN COiiPONENT DESCRIPTION AND FUNCTION STATUS SY-3-2918 SV-3-2919 SV-4-2914 SV-4-2915 SV-4-2916 SV-4-2917 SV-4-2919 118 81 ASCO Solenoid valve.

AuxxI harv feeduater to steaa generator ASCO Solenoid valve.

Auxiliary feeowater to stean generator Qualified Qual ifi eo SY-3-2928 Thru -2925 SV-4-2928 Thru -2925 76 ASCO Solenoid valve.

Eaeroency containaent cooling water valves Qualified A] SV-3-318A Sl POV-4-2684aLS 187 Al ASCO Solenoid valve 8)

NANCO Liait snitch Reactor cooling systea charging line Qualified SV-3-3188 ASCO Solenoid valve.

Reactor cooling systea charging line Qualified

23-Jun-84 TURKEY POINT UNITS 3h4 STATUS OF NASTER 18CFR 58.49 LIST Page 15 TAS 0 TER ITEN CONPONENT DESCRIPTION AND FUNCTION STAIUS SV-4-2918 T3Pll, T3PI2)

T3P22, T3P41,
T3P42, T3P43, T3P51)

T3P53) T3CII,

T3C12, T3C13)

T3C21)

T3822)

T3C23) T3III)

T3112)

T3114)

T3115, T3121)

T3122)

T3123)

T3124 T4P12)

T4P21, T4P22)

T4P41)

T4P42)

T4P43)

T4P51, T4P52, T4CII)
T4C12, T4C13, T4C21 T4C22)

T4C23 ~ T4112, T4114)

T4115)

T4121)

T4122, T4123, T4124 T4C22 None None ASCO Solenoid Valve an

. auxxliarv feedwater systea Crouse-Hands Contatnuent penetration asseabiy.

688 V power, control and anstruaentatton penetration Crouse-Hinds 688 V control cable penetration Qualified Qualafxed Qualified 14123 None Crouse-Hands 688 V

xnstruaentataon cable penetration Qualified 14124 None Grouse-Hinds 688 V

anstrunentataon cable penetration Qualified r4851 None Crouse-Hinds 688 V power cable penetration Qualified

23-Jun-84 TURKEY POINT UNITS MI STAI'US OF NASTER 18CFR SB.49 LIST Page lb TAS 0 IER ITEN CDNPONENT DESCRIPTION AND FUNCTION STATUS TIP52 None Crouse-Hinds bBB V pouer cable penetration Qualified TE-3-3448 throuqh TE-3-34b3 TE-4-3448 through TE-I-34b3 TE-3-418 TE-3-428 TE-3-438 TE-I-418 TE-4-428 TE-4-438 Pyco RTDs.

Provide teaperature indication for containnent ventilation charcoal filter Pyco resistance teaperature detector (RTD).

RCS cold leg teaperature to recorder Qualified Qualified TE-3-4128,1E-3-412D TE-3-4228,TE-3-422D TE-3-4328,TE-3-4320 TE-4-4128.1E-4-412D IE-4-4228,TE-4-422D TE-4-4328,1E-4-432D TE-3-413A, TE-3-4138 TE-3-423A,TE-3-4238 TE-3-433A,TE-3-4338 1E-4-413A,TE-4-4138 TE-4-423A,TE-I-4238 TE-I-433A)1E-4-4338 Roseaount resistance teaperature detector (RTD).

Provide RCS hotleg over-teaperature trip signal PYCO resistance teaperature detector (RTD).

Reactor coolant subcooling margin nonitor Qualified Qualified

23-Jun-84 TURKEy POINT UNITS 344 STATUS OF NASTER IBCFR 58.49 LIST Page 17 TAG 0 TER ITEN CONPONENT DESCRIPTION AND FUNCTION STATUS lT/lS-3-h383A LT/IS-3-h3838 lT/LS-H383C l1/IS-4-I 383A ZT/?S-4-63838 LT/IS-4-a383C Tech. for Energy Corp. Acoustic aonitor.

Safety valve acoustic aonitoring systea Qualified NOTE I. Ilill be replaced during the next Unit 3 refueling outage presently scheduled to begin in Narch of I98S.