L-82-353, Advises That NUREG-0737,Item II.D.1.B Satisfied by Power Operated Relief Valve Block Valve Info Package & Listed Info

From kanterella
(Redirected from L-82-353)
Jump to navigation Jump to search
Advises That NUREG-0737,Item II.D.1.B Satisfied by Power Operated Relief Valve Block Valve Info Package & Listed Info
ML17213A354
Person / Time
Site: Saint Lucie 
Issue date: 08/13/1982
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.D.1, TASK-TM L-82-353, NUDOCS 8208200194
Download: ML17213A354 (3)


Text

7!

REGULATORY ~ORMATION DISTRIBUTION SY~M (RIDS)

AOCESSION NBR ~ 8208200194 DOC ~ DATE 82/08/13 NOTARIZED NO FACIL:50-335 St ~ Lucie Plant< Unit i~ Florida Power 8 Light Co.

AllTH,NAME AUTHOR AFFILIATION UHRIGeReEe Florida Power 5 Light Co ~

RBC IP ~ NAME RECIPIENT AFFILIATION EISENHUTrD.G.

Division of Licensing DOCKET 05000335

SUBJECT:

Advises that NUREG"0737 Item II,DE 1,B satisfied by "Power Operated Relief Valve Block Valve Info Package~"

L described info.

DISTRIBUTION CODE:

A006S COPIES RECEIVED:LTR

~

ENCL.f SIZE:

TITLE: Response to NUREG -0737/NUREG-0660 TMI Action Plan Rgmts (OL s)

NOTES:

REC IP IFNT ID CODE/NAME ORB ¹3 BC 01 INTERNAL: ELD/HDS2 IE/DEP EPDS NRR/DE D IR 21 NRR/DE/ADMQE 23 NRR/DHFS/DEPY29 NRR/DL/ADL 16 NRR/DL/ADSA 17 NRR/DSI DIR 24 NRR/DS I/ADRP 26 NRR/DSI/AEB NRR/DSI/RAB NRR ST/ADGP 31 04 EXTERNAL:

ACRS 3g INPOgJ ~ STARNES NRC PDR 02 NT I' COPIES LTTR ENCL 7

7 1

0 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 10 10 1

1 1

1 1

1 RECIPIENT ID CODE/NAME IE/DEP DIR 33 IE/DEP/EPLB NRR/DE/ADCSE 22 NRR/DHFS D IR 28 NRR/DL D IR 14 NRR/DL/ADOR 15 NRR/DL/ORAB 18 NRR/DS I/ADDPS25 NRR/DS I/ADRS 27 NRR/DSI/ETSB NRR/DST D IR 30 NRR/DST/ADT 32 RGN2 FEMA REP DI V LPDR 03 NSIC 05 COPIES LTTR ENCL 1

1

'3 3

1 1

1 1

1 1

1 3

3 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 TOTAL NUMBER OF COPIES REUUIRED t LTTR 53 ENCL

'52

~(~

tp t

4 0

e

~

II'I OQ

~

'I I

P

'I

P~OX 14000, JUNO BEACH, FL33408

,J

~+1 f//i Office of Nuclear Reactor Regulation Attention:

Mr. Darrell G. Eisenhut, Director Division of Licensing U.S.

Nuclear Regulatory Commission Washington, D.C.

20555 FLORIDA POWER & LIGHT COMPANY August 13, 1982 L-82-353

Dear Mr. Eisenhut:

Re:

St. Luci e Unit 1

Docket Ho. 50-335 Post-TMI Requi rements HUREG-0737 Item I I.D.1 PWR Relief and Safety Valve Testing NUREG-0737, Item II.D.1.B contains the provision that PWR utilities demonstrate that PORV block valves function properly over the range of expected operating and accident condi tions.

During a meeting with NRC staff and utility representatives held on July 17, 1981, the above provision was discussed in detail and substantial agreement was reached regarding resolution of the requirement.

The details of the utility position is contained in a letter to Harold Denton, NRC by R.C.

Youngdahl, Consumers Power dated July 24, 1981.

Prototype testing of representative valve and operator configurations was performed under the EPRI program.

These test results were transmitted to Harold Denton, NRC by R.C. Youngdahl, Consumers Power on June 1,

1982 on behalf of the member utilities.

The block valves at St.

Luci e 1 are similar in design to the tested valves and the "PORV Block Valve Information Package" is applicable to St.

Luci e Unit 1.

The test results indicate satisfactory performance for tni s valve design.

In addition, the valve and operator manufacturers have verified by analysis that the valves and operators are properly sized to open and close against maximum design flow and differential pressure.

In conclusion, we believe that HUREG-0737; Item II.D.1.B. is satisfied by the "PORV Block Valve Information Package" and the above information.

Very truly yours, Robe

. Uhrig Vice President Advanced Systems and Technology oV4 REU/PKG/JDR/mbd cc:

Mr. James P. O'Reilly, Region II Harold F. Reis 8208200i94 8208i3 PDR

  • DOCK 05000335 P

PDR PEOPLE... SERVING PEOPLE