L-81-484, Discusses re-exam of Stretch Power Application Re Sections 7.2.3 Loss of All Non-Emergency AC Power Event, & 7.3.4, Seized Rotor Event, Per Request

From kanterella
(Redirected from L-81-484)
Jump to navigation Jump to search
Discusses re-exam of Stretch Power Application Re Sections 7.2.3 Loss of All Non-Emergency AC Power Event, & 7.3.4, Seized Rotor Event, Per Request
ML17212B011
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 11/18/1981
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
L-81-484, NUDOCS 8111230363
Download: ML17212B011 (4)


Text

R" 6UL'AITORY I rORMAiTIOV"DISTRIBUTION SYSl 8i (RIDS)

DOCKEITI P.

05090335'OTES'::

ACCESSION( NBR':8111230363(

DOC ~ DAiTEi: 81/11/18 NOTARIZED': NO FACILi:50: 335 St ~ Lucie' Iant< Unit 1~. Florida>> Power 8 Ltigpti Cb;:-

AUTtHIe NAi41KI AUTHOR AFFILI'ATKON UHRI G., R, Et, Floriida>> Power L Lighit C'o ~

'ECIPe VA'>>IEI RECIIPZENT AFF ILiIAiTIONi KiISEVHUTipD'.G,:

Division of Licehsing

SUBJECT:

Discusses re}.exam of stretchI power i applhcation>> reI Sebtiions 7e2,3 "Loss of Al l Non>> Emei gjency ac Power EVentr,"'

7'3'4r "S'eized Rotor Event'r,"

pe'r reque'st".,

D~ISTRiIBUTZON CODEI:

A015S" COPIES RECEKVED! LiTR

'NCLr 'IZE!er " '

'iITLEI:.'hsi te EIriergency Powel>> Systems~

RECiiPZKNTII IOi CODE'/N A>>41KI ACTIION::

OR8I 43. BCI 01 INTERNALi:

AEGD IEI 0

6'RR'/DL'/DRA 8

1 2'RR'/DG I'/PSB>>

14 e

COPIES L>>T'TR ENC Lr 7

2; 1

1 RECIPiENT'D COOK/NAMEl ELD 17 MPA:

18 NR /ICSB 09

~ FI 04"

,COPZEB LiTiTRI ENCL(

1.

1 1-EX TERN ALi:

ACRS LPDR

,VS'I C 1S'3i Oia 16 1

1 1

INPO>>r Ji, ST'ARNES VRCI PDRi 02'TiI S"'.UV 44'I

'.i7 0

TOiTAL VUQBERI OF COPIES'EQUIRED:: LiTTR 37 ENCLI

V Ol u

P.o. BOX 529100 MIAMI,F L33152 Ji'ee~~4 FLORIDAPOWER 84 LIGHTCOMPANY November 18, 1981 L-81-484 Office of Nuclear Reactor Regulation Attention:

Mr. Darrell G. Eisenhut, Division of Licensing U.S.

Nuclear Regulatory Commission Washington, D.C.

20555

Dear Mr. Ei senhut:

Re:

St.

Lucie Unit I Docket No.

50-335 Stretch Power A

lication In the course of the review of our Stretch Power Application the NRC staff has requested that two previously analyzed events be reevaluated by Florida Power 8 Light to -include the assump-tion o'f the following additional failure mechanisms:

I)

  • 7.2.3 Loss of All Non-Emergency A-C Power Event; additional assumption required

- worst single active failure for this event.

2)

  • 7.3.4 Seized Rotor Event; additional assumptions r equi red - loss of offsi te power and worst single active failure for this event.

(* numbering system used in Stretch Power Application)

Based on a reexamination of the analyses already submitted for Stretch Power it is FPLs position that the results on an ana-

. lysis of these postulated events that assumes the additional failure mechanisms discussed above will continue to satisfy the acceptance criteria.

However, we will reevaluate the seized Rotor and Loss of All Non-Emergency A-C Power events with these additional assumptions to confirm this position and submit the results within 6 months of the NRC approval of the Stretch Power Application.

Very truly yours, Robert E. Uhrig Vice President Advanced Systems and Technology REU/DME/ah poiS It.

cc:

Mr. J.P.

O'Reilly, Region II Harold F. Reis, Esquire Siii230363 8iiiji8 PDR ADOCK OS00033Si P

PDRz PEOPLE... SERVING PEOPLE

~t(