L-81-289, Responds to IE Bulletin 81-02, Failure of Gate Type Valves to Close Against Differential Pressure. No Subj Valves Installed Where Differential Pressure Required to Close. Vendor Reviewing Gate Valves Per 810622 Deficiency Rept

From kanterella
(Redirected from L-81-289)
Jump to navigation Jump to search
Responds to IE Bulletin 81-02, Failure of Gate Type Valves to Close Against Differential Pressure. No Subj Valves Installed Where Differential Pressure Required to Close. Vendor Reviewing Gate Valves Per 810622 Deficiency Rept
ML20009G474
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 07/14/1981
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, IEB-81-02, IEB-81-2, L-81-289, NUDOCS 8108040301
Download: ML20009G474 (2)


Text

1 P O. HOX 529100 MI AMI,FL 33152 r,

- pm,,,

I F LOHID A POWE H & LIGHT COMPANY pj g

July 14, 1981 L-81-289 s

$ (I !Dif%

Mr. James P. O'Reilly, Director, Region II Office of Inspection & Enforcement N g

^

U. S. Nuclear Regulatory Commission

["ff g i

101 Marietta Street, Suite 3100 U " g319- __

-o L

Atlanta, Georgia 30303 O

n W \\ 9,s. T' lS $ o O

\\kJs

Dear Mr. O'Reilly:

\\

y V

W 89 IE Bulletin 81-02 Florida Power & Light Company (FPL) has reviewed IE Bulletin 81-02, " Failure of Gate Type Valves to Close Against Differential Pressure", with respect to St. Lucie Unit 2, and has determined that the subject valves manufactured by Westinghouse Electro-Mechanical Division (W-EWD), or Borg Warner Nuclear Valve Division (BW-NVD), are not or will not be installed or maintained as spares for installation where they are required to close with a differential pressure across them in any Ebasco safety related system or as PORV block valves supplied by Ebasco.

On June 22, 1981, FPL informed your office of a potential deficie;ry, in accordance with 10 CFR Part 50.55(e), regarding certain motor operated gate valves, procurred from Westinghouse under Combustion Engineering (C-E) purchase order 9401086.

C-E has requested that Westinghouse review each of the valves included in the purchase order and to advise them of the applicability of the closure problem to each model, and to provide them with a schedule for any valve part replacements. FPL will provide the remaining information required by this bulletin as part of the final report closing out this 10 CFR Part 50.55(e) item.

Very

yours, Q.Il S

Robert E. Uhrig Vice President jj Advanced Systems & Technology REU/TCG/ah cc: Harold F. Reis, Esquire 8108040301 810714 PDR ADOCK 05000389 G

PDR PEOPLE.. CE RVING PEOPLE

I

/

STATE OF FLORIDA

)

)

SS COUNTY OF DADE

)

Robert E. Uhrig, being first duly sworn, deposes and says:

That he is a Vice President of Florida Power & Light Company, the Applicant herein:

That he has executed the foregoing document; the the statements made in this said document are true and correct-to the best cif his knowledge, information and belief, and that he is authorized to execute the document on behalf of said Applicant.

(

J

~

Robert E. Uhrig

[

Subscribed and sworn to before me this

/Y day of 9d 19f/

0{

2. de NOTitRY PUBLIC, in ghd for the County of Dade, State of Florida

(<ct a. f PLClic. State Cf ho'id3 Et L3!93 My ce.anasion Eg,res Octcter 30, 1953 My commission expires:

eveea nuu mayr aid Bonding Agencg