L-80-170, Forwards Results of Steam Generator Insps Showing Approx 22.4% Tube Plugging.Requests Permission to Resume Operation on 800612

From kanterella
(Redirected from L-80-170)
Jump to navigation Jump to search
Forwards Results of Steam Generator Insps Showing Approx 22.4% Tube Plugging.Requests Permission to Resume Operation on 800612
ML17339B082
Person / Time
Site: Turkey Point NextEra Energy icon.png
Issue date: 06/05/1980
From: Robert E. Uhrig
FLORIDA POWER & LIGHT CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
Shared Package
ML17339B083 List:
References
L-80-170, NUDOCS 8006090340
Download: ML17339B082 (5)


Text

~r

~ I REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:8006090340 DOC ~ DATEt 80/06/OS NOTARIZED'O DOCKET FACIL:50 251 Turkey Point Planti Unit Qg Florida Power and Light C

050002S1 AUTH BYNAME AUTHOR AFFILIATION UHRIGi R ~ E ~

Florida Power 8 Light Co, RECIP ~ NAME RECIPIENT AFFILIATION EISENHUTiD,G ~

Division of Licensing SUBJECT; Forwards results of steam generator insps showing approx 22 'X tube plugging, Requests permission to resume operation on 800612

~

DISTRIBUTION CODE:

A001S COPIES RECEI YED: LTR ENCL ~ SIZE: ',+5~

TITLE: General Distribution for after Issuance of Opeiating Lic PQ ~

NOTES.

ACTION:

iINTERNAL; EXTERNAL+

RECIPIENT ID CODE/NAME 05 BC 00+F5 01 12 18E 17 ENGR BR 19 PLANT SYS BR 21 EFLT TRT SYS OELD 03 LPDR 23 ACRS COPIES LTTR ENCL 7

7 1

1 2

2 1

1 1

1 1

1 0

1 1

16 16 RECIP IEN'T ID CODE/NAME 02 NRC PDR 15 CORE PERF BR 18 REAC SFTY BR 20 EEB EPB~DOR STS GROUP LEADR 04 NSIC COPIES LTTR ENCL 1

1 1

1 1

1 1

1 1

1 1

1 1

JUN 3, 0 158)

TOTAl NUMBER OF COPIES REQUIRED:

LTTR 38 ENCL 37

i 'fI'

'I ~

I I I

I' If

1 s

sl P.o. BOX 529 I00 MIAMI,F L 33152 Office of Nuclear Reactor Regulation Attention:

Nr. Darrell G. Eisenhut, Director Division of Licensing U.

S. Nuclear Regulatory Commission Washington, D.

C.

20555

Dear Nr. Eisenhut:

FLORIDA POWER & LIGHTCOMPANY June 5, 1980 L-80-170 Re:

Turkey Point Unit 4 Docket No. 50-251 Steam Generator Ins ections The results of the Turkey Point Unit 4 steam generator inspections conducted during the current outage are attached.

The inspections which were performed in accordance with Turkey Point Unit 4 operating license DPR-41 showed no new phenomena and verified that the general pattern of denting in Unit 4 is within predictable limits and consistent with previous inspections of the Turkey Point Units.

The general criteria applied for steam generator inspections and preventive plugging are the same as previously applied to Turkey Point Units 3 and 4

to provide in excess of'ix months of operation.

This approach provides reasonable assurance of steam generator tube integrity such that safe operation of the unit during normal full power operation and during hypo-thetical accident conditions is assured for an operating period in excess of six effective full power months.

Therefore, the implementation of this program with the resulting preventive plugging, enables continued safe full power operation of Turkey Point Unit 4 for a period in exces's of six months.

Total steam generator tube plugging at the conclusion of the current outage wi 11 be approximately 22.4/. This is conservatively bounded by the 25K tube plugging ECCS analysis.

The results of this inspection and the preventative tube plugging program have been reviewed by the Turkey Point Plant Nuclear Safety Committee and the Florida Power 8 Light Company Nuclear Review Board.

They have concluded that based on the inspection results, the implemented plugging pattern, and previously submitted analysis, that the return of Turkey Point Unit 4 to full power operation for at least six effective months does not involve an unreviewed safety question.

In accordance with condition Dl of operating license DPR-41, Florida Power Q 8 Light Company requests permission to return Unit 4 to power operation.

PEOPLE... SERVING PEOPLE

1 C

Mr. Darrell G. Eisen Office of Nuclear Reactor Regulation Page Two Based on our current schedule, we could be ready to resume power operation by June 12, 1980.

We will keep you advised of any significant changes.

Very truly yours, Robert E. Uhrig Vice President Advanced Systems 8 Technology REU/JNB/ah Attachment cc:

J.

P. O'Rei lly, Region II Harold F. Reis, Esquire