REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR!7908100458 DOC ~ DATE; 79/08/07 NOTARIZEDI YES FACILt50 250 Turkey Point Planti Unit 3i Flor ida Power and Light 50 251 Turkey Point Planti Unit 0i Florida Power and Light C

AUTH INANE AUTHOR 'AFF ILIAT'ION UHRIG<R ~ E ~

F1 or.ida Power.

L Light Co ~

RECIP ~ NAME RECIPIENT AFFILIATION SCHNENCERiA ~

Operating Reactors Branch 1

DO T

000 050

SUBJECT:

Requests amend to Licenses DPR 31 L

DPR l1 to allow 10 effective months of facility operation prior to performance of next steam generator

insp,

'DISTRIBUTION CODE:

A001S COPIES RECEIVED:LTR Q ENCL g SIZE:

T'ITL'E e GENERAL DISTRIBUTION FOR AFTER ISSUANCE OF OPERATING. L'IC C'ft&ic 8 /

gaQ.~'OT-S

+ w~w~

mee~~eeea~ea~eseweteeosarr4~aaeeeem~~~wrey~~w~~wweas~esw~~eemrewwepeywsaewqeaaw-aaaee+ae-a~~ye RECIP IENT ID CODE/NAME'CTION:

05 BC SPY

(

INTERNAL: 12'EE 15 CORE PERF

'BR 17 ENGR BR 19 PLANT SYS BR

?1 EFLT TRT SYS GELD EXTERNAL: 03 LPDR 23 ACRS COPIES LTTR ENCL 1

16 RECIPIENT ID 'CODE/NAME 02 NRC PDR 14 TA/EDO 16 AD SYS/PROJ 18 REAC SFTY BR 20 EEB 22 BRINKMAN 04 NSIC COPIES LTTR ENCL 0

TOTAL NUMBER OF COPIES REQUIRED t

= LTTR 39 ENCL'.

6$

P. 0.

Box 529100 Miami, Florida 33152

>y9 Ag~

Office of Nuclear Reactor Regulation Attention:

Mr. A. Schwencer, Chief Operating Reactors Branch Pl Division of Operating Reactors U.ST Nuclear Regulatory Commission Washington, D.C.

20555 FLORIDA POWER 8, LIGHTCOMPANY August 7, 1979 L-79-215

Dear Mr. Schwencer:

4p~,.

RE:

Turkey Point Uni-ts 3 and 4

Q' Docket Nos.

50-250 and 50-251 Steam Generator Ins ection On March 6, 1979 and May 18, 1979 Florida Power 5 Light Company submitted the results of the most recent steam generator inspections for Turkey Point Units 3 and 4 respectively.

As indicated in these submittals, steam generator tube plugging was performed using previously acceptable methodologies so as to allow at least 10 effective months of operation.

Your 1'etters of 'March 30, 1979 and June 15, 1979 in response to our letters of March 6 and May 18, allowed 6 ef-fective months of operation, and stated that you preferred not to make a

judgment concerning 10 effective months of operation.

Florida Power 8I Light Company requests an amendment to Operating Licenses EP R-31 and P R-41 to allow 10 effective months of operation prior to perform-ing another steam generator inspection.

(Turkey Point Unit 3 is scheduled to shutdown November 15, 1979 for a refueling outage at which time the steam generator inspection will'e performed.)

The continued excell'ent operating experience of Turkey Point Units 3 and 4 without detectable steam generator tube leaks, and our submittals of March 30, 1979, and June 15, 1979 provide adequate justification for this request.

Further.,

the license conditions (El, E2, and E3 for PR 31 and l2, D3 and D4 for tP R 41) for steam generator operations provide adequate assurance of continued protection of the health and safety of the.public.

Considerations of man-rem exposure incurred during an outage, additional cost to our customers for the fuel used to generate replacement power during, the

outage, and the increased use of foreign oil to generate the replacement power make i.t imperative to reduce the frequency of steam generator inspec-tions to the minimum required to maintain adequate assurance of public health and safety.

It is our position that the requested 10 month operating period provides a proper balance of all these considerations and should therefore be granted.

The Turkey Point Plant Nuclear Safety Committee and the Florida Power 5 Light Company Nuclear Review Board have reviewed this request and have concluded that it does not involve an unreviewed safety question.

PEOPLE, SERV

Office of Nuclear ftactor Regulation, Page Two In order to allow for proper outage planning, we request that you reply to this request by August 24, 1979 for Turkey Point Unit 3 and September 1,

1979 for Turkey Point 'Unit 4.

If you should have any questions, please do not hesitate to contact me.

We have determined that since this request involves a single safety issue and a duplicate amendment, the request should be classified as a Class I and a

Class III amendment pursuant to 10CFR 170.

Accordingly, a check for $4,400 is attached.

Very truly yours, obert E. Uhrig Vice President Advanced Systems 8 Technology REU/GDW/dlh cc:

J.

P. O'Reilly, Region II Robert Lowenstein, Esquire

STATE OF FLORIDA

)

)

COUNTY OF DADE

)

ss A. D. Schmidt being first duly sworn, deposes and says:

That he is Vice President Light Company, the herein; of Florida Power That he has executed the foregoing document; that the state-ments made in this said

document, are true and correct to the best of his knowledge, information, and belief, and that he is authorized to execute the document on behalf of said A. D. Schmidt Subscribed and sworn to before me this day of NOTARY PUBLIC, in and for the County of Dade, State of Florida AOTARY PuSUC STATE OF FI.ORIOA ll lARGE OOMMISSION EI(FIRES AIIQIIST +

fgff TffflV PAYSNQ gQffffgg gggggy My commission expires: