L-2014-373, Environmental Protection Plan Report Minor Permit Revision for Storm Water Management Iww Permit No. FL0002208
ML14349A323 | |
Person / Time | |
---|---|
Site: | Saint Lucie ![]() |
Issue date: | 12/10/2014 |
From: | Katzman E Florida Power & Light Co |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
EPP 3.2.3, L-2014-373 | |
Download: ML14349A323 (24) | |
Text
0FPL.
December 10, 2014 L-2014-373 10 CFR 50.4 EPP 3.2.3 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re: St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 Environmental Protection Plan Report Minor Permit Revision for Storm Water Management IWW Permit No. FL0002208 Pursuant to section 3.2.3 of the St. Lucie Environmental Protection Plan, Florida Power & Light Company (FPL) is hereby forwarding the enclosed copy of the revision to the Industrial Wastewater Facility Permit (Permit Number FL0002208) as issued by the State of Florida Department of Environmental Protection on November 18, 2014.
Please contact Vince Munn6 (772) 263-2847 should you have any questions on this matter.
Sincerely, Eric S. Katzman Licensing Manager St. Lucie Plant ESK/tlt Enclosure ci:
Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957
L-2014-373 Enclosure Enclosure Minor Permit Revision for Permanent Storm Water Management IWW Permit No. FL0002208 (22 pages)
FLORIDA DEPARTMENT OF I (:R
.%10 RK(..'K S(..'{ IT VRF*
FL " *1 ENVIRONMENTAL PROTECTION A..R,.()S 1J - :lN:]..\
BOB MARTINEZ CENTER I I. 'it)\'l[RN I1 2600 BLAIRSTONE ROAD TALLAHASSEE. FLORIDA 32399-2400 1H-RS.II. I. VI N Y..\1h.I1 R.
SI: R[IýA RY November 18, 2014 SENT BY EMAIL TO:
(.loseph.Jenseni'@fpl.corn)
Joseph Jensen Site Vice President Florida Power & Light (FPL) 6501 S. Ocean Drive Jensen Beach, Florida 34957 Re: Florida Power & Light St. Lucie Power Plant NPDES Permit No. FL0002208 Minor Permit Revision for Storm Water Management
Dear Mr. Jensen:
On May 30, 2014, the Department of Environmental Protection (Department) received a minor revision application for the above referenced facility. FPL requested the use of portable pumps to evacuate excess storm water at the Units I and 2 cooling condenser water pits to maintain maximum personnel safety. After review, the Department hereby approves the request pursuant to Rules62-620.200(24),62-620.200(25), and 62-620.325(2), Florida Administrative Code. All other conditions of the permit shall remain the same except as specifically revised. Please attach this letter and the accompanying revised permit pages to NPDES Permit No. FL0002208.
If you object to this permit revision you may petition for an administrative hearing in accordance with the enclosed Notice of Rights. If a petition is filed, then this permit revision does not become effective. If you have any questions regarding this permit revision, please contact Mr. Marc Harris, P.E., in the Industrial Wastewater Section at (850) 245-8589.
Sincerely, Elsa A. Potts, P.E.
Program Administrator Industrial Wastewater Program Division of Water Resource Management EAP/mh/bn Attachment cc: Vince Munne, FPL (Vince.Murnne(i) fpl.com)
John Jones, FPL (John.jones(ý,Nfl.con)
Hambor Michael., DEP West Palm Beach (Michael. Hambor(i.dep.state. fl. Lus)
NOTICE OF RIGHTS A person whose substantial interests are affected by this permit revision may petition for an administrative proceeding (hearing) in accordance with Section 120.57, Florida Statutes. The petition must contain the information set forth below and must be filed (received) in the Office of General Counsel of the Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-3000, within 14 days of receipt of this Permit. A petitioner, other than the applicant, shall mail a copy of the petition to the applicant at the address indicated in the attached letter at the time of filing. Failure to file a petition within this time period shall constitute a waiver of any right such person may have to request an administrative determination (hearing) under Section 120.57, Florida Statutes.
The Petition shall contain the following information:
(a) The name, address, and telephone number of each petitioner; the name, address, and telephone number of the petitioner's representative, if any; the Department case identification number and the county in which the subject matter or activity is located; (b) A statement of how and when each petitioner received notice of the Department action; (c) A statement of how each petitioner's substantial interests are affected by the Department action; (d) A statement of all disputed issues of material fact. If there are none, the petition must so indicate; (e) A statement of facts that the petitioner contends warrant reversal or modification of the Department action; (f) A concise statement of the ultimate facts alleged, as well as the rules and statutes which entitle the petitioner to relief; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wants the Department to take.
If a petition is filed, the administrative hearing process is designed to formulate agency action.
Accordingly, the Department's final action may be different from the position taken by it in this intent.
Persons whose substantial interests will be affected by any decision of the Department with regard to the application have the right to petition to become a party to the proceeding. The petition must conform to the requirements specified above and be filed (received) within 14 days of receipt of this intent in the Office of General Counsel at the above address of the Department. Failure to petition within the allowed time frame constitutes a waiver of any right such person has to request a hearing under Section 120.57, F.S., and to participate as a party to this proceeding. Any subsequent intervention will only be at the approval of the presiding officer upon motion filed pursuant to Rule 28-5.207, F.A.C.
FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION 2600 BLAIR STONE ROAD TALLAHASSEE, FLORIDA 32399-2400 STATEMENT OF BASIS FOR MINOR PERMIT REVISION Permit Number: FL0002208 Application Date: May 30, 2014 Permit Writer: Bala Nori Additional Information: August 25, 2014, September 5, 2014 DEP File No.: FL0002208-16-IWB & October 14, 2014
- i. SYNOPSIS OF APPLICATION A. Name and Address of Applicant Joseph Jensen Site Vice President Florida Power & Light 6501, S. Ocean Drive Jensen Beach, Florida 34957 For:
Florida Power & Light St. Lucie Plant Units I and 2 Hutchinson Island St. Lucie County Florida B. Description of Proposed Activity:
On May 30, 2014, the Florida Department of Environmental Protection (Department) received a minor revision application from Florida Power & Light (FPL) for the above referenced facility. FPL is requesting authorization to discharge storm water from the Units I and 2 condenser cooling water pits during extreme storm events. These events occur on a very rare basis; the last two events occurred on August 20, 2008 (Tropical Storm Fay) and January 9, 2014.
During extreme storm events at the St. Lucie Plant, storm water can accumulate in the Units I and 2 condensate pits and component cooling water pits. The sump pumps in these pits can become overwhelmed, which can result in a rapid rise of the water levels within these pits, ultimately inundating the electrical equipment and causing a potential shock hazard. To manage the stormwater accumulation in the pits, FPL will deploy portable pumps to evacuate the excess storm water in those areas.
The pumped storm water will be discharged at four locations to the intake and discharge canals, and as the event unfolds, plant staff will sample the storm water prior to discharge. The sampling will include the same type of requirements as other stormwater outfalls included in the permit.
Changes to the permit (1) Page 2. The new internal outfall was included in the list of outfalls to represent the pumped discharges to the intake and discharge canal during the storm events.
(2) Page II. A new internal outfall for the emergency stormwater discharge was included, along with the appropriate monitoring requirements.
This constitutes Revision C (Rev. C) to the permit. All changes to the permit are noted in Rev. B by underline with a margin bar indicating lines where changes have been made for this revision.
2
STATE OF FLORIDA INDUSTRIAL WASTEWATER FACILITY PERMIT PERMITTEE: PERMIT NUMBER: FL0002208 (Major) Rev. C Florida Power & Light (FPL) FILE NUMBER: FL0002208-01 I-IWIS ISSUANCE DATE: September 29, 2011 REVISION DATE: November 18, 2014 RESPONSIBLE OFFICIAL: EXPIRATION DATE: September 28, 2016 Richard L. Anderson Vice President 6501 S. Ocean Drive Jensen Beach, Florida 34957 FACILITY:
St. Lucie Power Plant Units I and 2 Hutchinson Island St. Lucie County, Florida Latitude: See Note Below Longitude: See Note Below Note: Latitude and longitude are not shown at the permittee's request, for purposes of Homeland Security pursuant to federal regulations found at 18 CFR 388.113(c)(i) and (ii) and by Presidential Directive dated December 17, 2003.
This permit is issued under the provisions of Chapter 403, Florida Statutes (F.S.), and applicable rules of the Florida Administrative Code (F.A.C.) and constitutes authorization to discharge to waters of the state under the National Pollutant Discharge Elimination System. This permit does not constitute authorization to discharge wastewater other than as expressly stated in this permit. This permit is accompanied by an Administrative Order, pursuant to paragraphs 403.088(2)(e) and (f),
Florida Statutes. Compliance with Administrative Order, A0022TL is a specific requirement of this permit. The above named permittee is hereby authorized to operate the facilities in accordance with the documents attached hereto and specifically described as follows:
FACILITY DESCRIPTION:
The facility is an electric generating plant with a total nameplate rating of 1908 megawatts. The facility consists of two nuclear powered steam electric generating units (Unit I and Unit 2).
Units I and 2 use water from the Atlantic Ocean, a Class III marine water body, to remove heat from the main condensers via the once-through cooling water (OTCW) and auxiliary equipment cooling water (AECW) systems. Cooling water gravity flows from the Atlantic Ocean through three offshore intake structures into the intake canal. The water is then pumped through the main condensers for each unit. Heated cooling water is released to the discharge canal and back to the Atlantic Ocean through existing offshore Y and multi-port diffusers.
Units I and 2 are also regulated under the Florida Electrical Power Plant Siting Act (License No. PA74-02).
The radioactive component of the discharge is regulated by the U.S. Nuclear Regulatory Commission under the Atomic Energy Act, and not by the Department or the U.S. Environmental Protection Agency under the Clean Water Act.
WASTEWATER TREATMENT:
Facility discharge and treatment include the following. Once-through non-contact condenser cooling water (OTCW) and auxiliary equipment cooling water (AECW) are chlorinated. Low volume waste (LVW) (consisting of water treatment system wastewater, steam generator/boiler blowdown, and equipment area floor drainage), non-radioactive wastes/liquid radiation waste, and stormwater associated with industrial activity are treated by chemical/physical processes including neutralization, settling, ion exchange and micro filtration. Non-industrial stormwater and intake screen wash water are discharged without treatment.
PERMITTEE: Florida Power & Light (FPL) PERMIT NUMBER: FL0002208 (Major) (Rev. C)
FACILITY: St. Lucie Power Plant EXPIRATION DATE: September 28, 2016 REUSE OR DISPOSAL:
Surface Water Discharge D-001: An existing 1,487 MGD daily maximum flow, 1,362 annual average daily flow permitted discharge to the onsite discharge canal, thence to the Atlantic Ocean, Class Ill Marine Waters, (WBID 8103).
Internal Outfall 1-003: An existing permitted discharge to the discharge canal.
Internal Outfall 1-005: An existing permitted discharge to the discharge canal.
Internal Outfall 1-007: An existing permitted discharge to the discharge canal.
Internal Outfall 1-008: An existing permitted discharge to the intake canal.
Storm Water Outfall 1-009: A new' permitted emergency storm water discharge to the intake and dischargecanals via portablepumps.
Storm Water Outfall 1-06B: An existing intermittent permitted storm water discharge to the intake canal via an outlet control structure.
Storm Water Outfall 1-06C: An existing intermittent permitted storm water discharge to the intake canal via an outlet control structure.
Storm Water Outfall 1-06D: An existing intermittent permitted storm water discharge to the intake canal via an outlet control structure.
IN ACCORDANCE WITH: The limitations, monitoring requirements and other conditions set forth in this Cover Sheet and Part I through Part IX on pages 1 through 25 of this permit.
2
PERMITTEE: Florida Power & Light (FPL) PERMIT NUMBER: FL0002208 (Major) (Rev. C)
FACILITY: St. Lucie Power Plant EXPIRATION DATE: September 28, 2016 Monitoring Site Number Description of Monitoring Site OUI-5 Storm water discharge prior to entering the intake canal.
- 10. During the period beginning on the issuance date and lasting through the expiration date of this permit, the permittee is authorized to discharge stormwater associated with industrial activity from the Former Oil Storage Area from Internal Outfall 1-06B to the intake canal. Such discharge shall be limited and monitored by the permittee as specified below and reported in accordance with Permit Condition I.C.3.:
Effluent Limitations Monitorin2 Reauirements Max/ Frequency of Sample Monitoring Parameter Units Min Limit Statistical Basis Analysis Type Site Number Notes Flow MGD Max Report Daily Maximum Annually Calculated OUI-3 Max Report Monthly Average AnnuallyCalculatedOUI-3 Solids, Total Suspended mg/L Max Report Daily Maximum Annually Grab OUI-3 Oil and Grease mg/L Max Report Daily Maximum Annually Grab OUI-3 II. Effluent samples shall be taken at the monitoring site locations listed in Permit Condition I.B.10. and as described below:
Monitoring Site Number Description of Monitoring Site OUI-3 Discharge from the former oil storage area prior to entering the intake canal.
- 12. During the period beginning on the issuance date and lasting through the expiration date of this permit, the permittee is authorized to discharge storm water not associated with industrial activity from Internal Outfall 1-06C to the mangrove impoundment. Such discharge shall be limited and monitored by the permittee as specified below and reported in accordance with Permit Condition I.C.3.:
Effluent Limitations Monitoring Requirements Max/ Frequency Sample Monitoring Parameter Units Min Limit Statistical Basis of Analysis Type Site Number Notes Flow MGD Max Report Daily Maximum Max ReFlowlMAnnually Calculated OUI-4 Oil and Grease mg/L Max Report Daily Maximum Annually Grab OUI-4
- 13. Effluent samples shall be taken at the monitoring site locations listed in Permit Condition I.B. 12. and as described below:
Monitorin Site Number Description of Monitoring Site OUI-4 Stormwater discharge prior to entering the mangrove impoundment area.
- 14. During the period beginning on the issuance date and lasting through the expiration date of this permit, the permittee is authorized emergency discharge during extreme storm events consisting of stormwater associated with condensate pits and component cooling water firom InternalOutfall 1-009 to the intake and discharge canals. Such discharge shall be limited and monitored by the permnittee as specified beloiv and reportedin accordance with Permit Condition 1.C.3..
10
PERMITTEE: Florida Power & Light (FPL) PERMIT NUMBER: FL0002208 (Major) (Rev. C)
FACILITY: St. Lucie Power Plant EXPIRATION DATE: September 28, 2016 FfI7?jnt I imitrjtinnn
[ ,tnnitnrino,Rgnuirpngnt.iv 1Monitorin[
MALL" Frequenci,of Sapl Sit._e Parameter Units Min Linmit Statistical Basis Analsis _Tye Number Notes Flow MGD Max R Daily, Maximum Per Discharze Calculated OUI-6 FwMax Alonthll,Average Oil and Grease MelL Max 15.0 Monthl, Average Per Discharge Grab OUI-6 Max 20.0 Daily Maximum Solids, Total Suspended mL Max 30.0 Montthlv Average Per Discharge Grab OUI-6 Max /00.0 Daily Maximum Max 9..0 Daily,
_ _ _s. u A4in 6.0 Daily Maximum Minimum _
Per Discharge Grab OUI-6
- 15. Effluent samples shall be taken at the monitoringsite locations listed in Permit Condition I.B. 14. and as described below:
A/on i.toringSite Number Descript ion afMon ilorin Site OUI-6 Siormwater discharge nrior to enteringthe intake or dischargecanal.
- 16. Discharge of intake screen wash water from Internal Outfall 1-007 is permitted without limitation or monitoring requirements.
- 17. Discharge of storm water and wash-down water consisting of potable water with no chemical additives discharge from Spent Nuclear Fuel Dry Storage Area to the intake canal through Internal Outfall 1-06D is permitted without limitations or monitoring requirements.
C. Other Limitations and Monitoring and Reporting Requirements I. The sample collection, analytical test methods, and method detection limits (MDLs) applicable to this permit shall be conducted using a sufficiently sensitive method to ensure compliance with applicable water quality standards and effluent limitations and shall be in accordance with Rule 62-4.246, Chapters62-160 and 62-601, F.A.C., and 40 CFR 136, as appropriate. The list of Department established analytical methods, and corresponding MDLs (method detection limits) and PQLs (practical quantitation limits), which is titled "FAC 62-4 MDL/PQL Table (April 26, 2006)" is available at http://www.dep.state.fl.us/labs/library/index.htm. The MDLs and PQLs as described in this list shall constitute the minimum acceptable MDL/PQL values and the Department shall not accept results for which the laboratory's MDLs or PQLs are greater than those described above unless alternate MDLs and/or PQLs have been specifically approved by the Department for this permit.
Any method included in the list may be used for reporting as long as it meets the following requirements:
- a. The laboratory's reported MDL and PQL values for the particular method must be equal or less than the corresponding method values specified in the Department's approved MDL and PQL list;
- b. The laboratory reported MDL for the specific parameter is less than or equal to the permit limit or the applicable water quality criteria, if any, stated in Chapter 62-302, F.A.C. Parameters that are listed as "report only" in the permit shall use methods that provide an MDL, which is equal to or less than the applicable water quality criteria stated in 62-302, F.A.C.; and
- c. If the MDLs for all methods available in the approved list are above the stated permit limit or applicable water quality criteria for that parameter, then the method with the lowest stated MDL shall be used.
When the analytical results are below method detection or practical quantitation limits, the permittee shall report the actual laboratory MDL and/or PQL values for the analyses that were performed following the instructions on the applicable discharge monitoring report.
Where necessary, the permittee may request approval of alternate methods or for alternative MDLs or PQLs for any approved analytical method. Approval of alternate laboratory MDLs or PQLs are not necessary if the laboratory reported MDLs and PQLs are less than or equal to the permit limit or the applicable water quality 11
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A W~hen Completed mail this report to: Department of Environmental Protection, Wastewater Compliance Evaluation Section, MS 3551, 2600 Blair Stone Road, Tallahassee, FL 32399-2400 PERMITTEE NAME Florida Power & Light (FPL) PERMIT NUMBER. L0002208-016IýWB MAILING ADDRESS. 6501 S. Ocean Drive Jensen Beach, Florida 34957 LIMIT: Final REPORT FREQ UENCY: Monthly CLASS SIZE NIA PROGRAM Industrial FACILITY St Lucie Plant Units I and 2 MONITORING GROUP NUMBER: D-001 LOCATION Hutchinson Island. FL MONITORING GROUP DESCRIPTION: Condenser once-through cooling water and auxili:ary equipment cooling water from Units I and 2 to the discharge canal thence the At ]antic Ocean.
RE-SUBMITTED DMR: El NO DISCHARGE FROM SITE F1 COUNTY St Lucie MONITORING PERIOD From: To:
OFFICE: Southeast District Parameter Quantity or Loading Units Quality or Concentration Units No. Frequency of Sample Type Ex. Analysis Flow Sample Measurement PARM Code 50050 I Permit Report MGD Hourly Pump Logs Mon. Site No. FLW-I Requirement (Dav.Max.)
Temperature IF), Water Sample (During Normal Operation) Measurement PARM Code 00011 I Permit Report DegF Hourly Recorder Mon. Site No EFF-2 Requirement (Day.Max.)
Temperature (F), Water Sample (During Maintenance Activities) Measurement PARM Code 0001I Q Permit 117 DegF Hourly Recorder Mon. Site No EFF-2 Requirement IDay.Max.)
Temp Dtff. between Intake and Sample Discharge (During Normal Operation) Measurement PARMCode6I576 I Permit 30 DegP Hourly Calculated Mon. Site No. EFF.2 Requirement _Da_'.Max.)
Temp Diff. between Intake and Sample Discharge Measurement (During Maintenance Activities)
PARM Code 61576 Q Permit 32 DegF Hourly Calculated Mon Site No. EFF-2 Requirement (Day.Max.)
Oxidants, Total Residual Sample Measurement PARM Code 34044 I Permit 0.1 0.1 ing/L Continuous Recorder Mon. Site No. EFF-2 Requirement I (Mo Avg) (Day.Max.)
Chlorination Duration Sample (Unit I) Measurement PARM Code 78739 1 Permit 120 ain Daily, 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Logs Mon. Site No. EFF-I Requirement (DayMas) _ _ _ _
certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted Based on my inquiry of the person or persons who manage the sysiem, or those persons directly responsible for gathering the information, the information submitted is. to the best of my knowledge and belief. true, accurate, and complete l am aware that there are significant penalties for submining false information, including the possihility of fine and imprisonment for knowing violations EXP IPOMENTIA ALAEXECUTIVE OFFICEROORTAUTHORIZEDfAGENT SIGNATUREOF PRINCIPALEXECUTIVEOFFICERORAUTHORIZEDAGENT TELEPHONEhNO DATE(mnsdd/vy COMMENT AND EXPLANATION OF ANY VIOLATIODNS (Reference all attachmentshere):
ISSUANCEIREISSUANCE DATE: November 2014 D-001 Final Monthly Page I of 2 DEP Form 62-620.910(10), Eff'ective Nov. 29. 1994
DISCHARGE MONITORING REPORT - PART A (Continued)
FACILITY. St Lucie Power Plant Units I and 2 MONITORING GROUP D-(01 PERMIT NUMBER FL0002208-016-1%WIB NUMBER MONITORING PERIOD From: To:
Parameter Quantity or Loading Units Qualty or Concentration Units No Frequency of Sample Type Ex Analysis Chlorination Duration Sample (Unit 2) Measurement PARM Code 78739 P Permit 120 min Daily; 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Logs Mon. Site No. EFF-I Requirement (Day Max.)
7-DAY CHRONIC STATRE Sample Mysidopsis bahia (Routine) Measurement PARMCodeTRP3E P Permit 100 percent Semiannually 24-hr TPC Mon. Site No. EFF-2 Requirement (Min.)
7-DAY CHRONIC STATRE Sample Mysidopsis bahia (Additional) Measurement PARMCodeTRP3E Q Permit 100 percent As needed As required by Mon. Site No. EFF-2 Requirement (Min.) the permit 7-DAY CHRONIC STATRE Sample Mysidopsis bahin (Additional) Measurement PARMICode TRP3E R Permit 100 percent As needed As required by Mon. Site No. EFF-2 Requirement (Min.) the permit 7-DAY CHRONIC STATRE Sample Memtdia beryllina (Routine) Measurement PARM Code TRP6B P Permit 100 percent Semiannually 24-hr TPC Mon. Site No. EFF-2 Requirement (Min) 7-DAY CHRONIC STATRE Sample Mentdta beryllina (Addttional) Measurement PARM CodeTRP6B Q Permit 100 percent As needed As required by Mon. Site No EFF-2 Requirement (Min the permit 7-DAY CHRONIC STATRE Sample Menidia beryllhna (Additional) Measurement PARM Code TRP6B R Permit 100 percent As needed As required by Mon. Site No. EFF-2 Requirement (Mm.) the permit ISSUANCE/REISSUANCE DATE. November2014 D-0O01 Final Monthly Page 2 of 2 DEP Form 62-620.910(I 0), Effective Nov. 29, 1994
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Department of Environmental Protection, Wastewater Compliance Evaluation Section, MS 3551, 2600 Blair Stone Road. Tallahassee. FL 32399-2400 PERN*flTTEE NAME: Florida Power & Light (FPLI PERMIT NUMBER: FL0002208-016-INWB MAILING ADDRESS 6501 S. Ocean Drive Jensen Beach, Florida 34957 LIMIT Final REPORT FREQUENCY Quarterly CLASS SIZE MA PROGRAM Industrial FACILITY St. Lucte Plant Units I and 2 MONITORING GROUP NUMBER. D-001 LOCATION: Hutchinson Island. FL MONITORING GROUP DESCRIPTION: Condenser ance-through cooling water and auxiliary equipment cooling water from Units I and 2 to the discharge canal thence the Atlantic Ocean.
RE-SUBMITTED DMR 0 NO DISCHARGE FROM SITE: 0 COUNTY: St. Lucte MONITORING PERIOD From To OFFICE: Southeast District Paratreter Quantity or Loading Units Qualty or Concentration Units No. Frequency of Sample Type Es. Analysis Nitrogen. Ammonia. Total (as N) Sample Measurement PARM Code 00610 I Permit Report mg/L Quarterly Grab Mon. Site No EFF-2 Requirement (Max.)
Nitrogen, Ammonia, Total (as N) Sample Measurement FARM Code 00610 7 Permit Report mg/L Quarterly Grab Mon Site No INT-I Requirement (Max.)
Nitrogen, Kjeldahl. Total (as N) Sample Measurement PARM Code 00625 I Permit Report mg/L Quarterly Grab Mon. Site No. EFF-2 Reurent (Max.)
Nitrogen. Kjeldahl, Total (as N) Sample Measurement PARM Code 00625 7 Permtt Report mg/L Quarterly Grab Mon. Site No. INT-I Requirement (Max.)
Nitrite plus Nitrate. Total I del. (as N) Sample Measurement PARM Code 00630 I Permit Report mg/L Quarterly Grab Mon. Site No. EFF-2 (Max (eMairement Nitrite plus Nitrate. Total I det. (asN) Sample Measurement PARMA Code 00630 7 Permit Report mg/L Quarterly Grab Mon. Site No. INT-I Requirement (Max.)
Nitrogen, Total Sample Measurement PARM Code 00600 I Permit Report mg/L Quarterly Grab Mon. Site No. EFF-2 Requirement .)
(Max I certify under penalty of law that this document and all attachments were prepared under my direction or superviston in accordance wtth a system designed to assure that qualified personnel properly gather and evaluate the tnformation submitted Based on my inquiry of the person or persons who manage the system, or those persons dtrectly responsible for gathering the tnformation, the tnformation submitted is. to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are signtficant penalties for submitting false information. including the possibility of fine and imprtsonment for knowing violations.
NAME/TITLE OF PRINCIPAL EXECUTIVE OFFICEROR AUTHORIZED AGENT I SIGNATUREOF PRINCIPALEXECUTIVEOFFICEROR AUTHORIZEDAGENT TELEPHONE NO DATEimr/csdd/yv,.'
COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here):
ISSUANCE/REISSUANCE DATE Novembei-2014 D-001 Final Quarterly Page I of 2 DEP Form 62-620.910110), Effective Nov. 29, 1994
DISCHARGE MONITORING REPORT - PART A (Continued)
FACILITY. St. Lucie Power Plant Units I and 2 MONITORING GROUP D-001 PERMIT NUMBER: FLOO02208-016-1WB NUMBER:
MONITORING PERIOD From: To:
Parameter Quantity or Loading Units Quality or Concentration Units No. Frequency of Sample Type Ex. Analysis Nitrogen. Total Sample Measurement PARM Code 00600 7 Permit Report mg/L Quarterly Grab Mon. Site No INT-I Requirement (Max.)
Phosphorus, Total (as P) Sample Measurement PARM Code 00665 I Perntit Report mgfL Quarterly Grab Mon. Stte No. EFF-2 Requirement (Max.)
Phosphorus, Total (as P) Sample Measurement PARM Code 00665 7 Permit Report mg/L Quarterly Grab Mon. Site No. INT-I Requirement (Max..)
Phosphate. Ortho (as P04) Sample Measurement PARM Code 00660 I Permit Report mg/L Quarterly Grab Mon. Site No. EFF-2 Requirement (Max.)
Phosphate, Ortho (as P04) Sample Measurement PARM Code 00660 7 Permit Report mg/I. Quarterly Grab Mon. Site No INT-I Requirement (Max.)
ISSUANCEfREISSUANCE DATE November 2014 D-O01 Final Quarterly Page 2 of 2 DEP Form 62-620 9)0(10). Effective Nov. 29, 1994
DEPARTMENT OF ENVrIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Department of Environmental Protection, Wastewater Compliance Evaluation Section, MS 3551, 2600 Blair Stone Road, Tallahassee. FL 32399-2400 PERMITTEE NAME: Florida Power & Light (FPL) PERMIT NUMBER: FL0002208-016-IWB MAILING ADDRESS: 6501 S. Ocean Drive Jensen Beach. Florida 34957 LIMIT Final REPORT FREQUENCY: Monthly CLASS SIZE MA PROGRAM Industrial FACILITY. St. Lucie Plant Units I and 2 MONITORING GROUP NUMBER: 1-003 LOCATION. Hutchinson Island, FL MONITORING GROUP DESCRIPTION: Liquid radiation waste discharge to the discharge canal to the Atlantic Ocean RE-SUBMITTED DMR: 0 NO DISCHARGE FROM SITE: 0 COUNTY St Lucie MONITORING PERIOD From: To OFFICE. Southeast District Parameter Quantity or Loading Units Quality or Concentration Units No. Frequency of Sample Type Es. Analysis Flow Sample Measurement PARM Code 50050 P Permit Report Report MGD Per hatch of Calculated Mon. Site No OUI-I Requirement (Mo.Avg.) (Day.MM ) process Solids, Total Suspended Sample Measurement PARM Code 00530 P Permit 30.0 100.0 mg/L Per batch of Grab Mon. Site No. OUI-I Requirement (Mo.Avg.) (Day.Max.)) process I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the informuation, the information submitted is. io the best of my knowledge and belief, true, accurate, and complete I am avwarethat there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations ONAME/TITLE OFPRINCIPAL EXECUTIVE OFFICER ORAUTHORIZED VTELEPHONE AGENT Rmrrhdd/yyyyh SIGNATRE OP PRtNCIPAL EXECUTIVE OFFICER ORAUTHO RIZEDAGENT NO DATE COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference all attachmentshere)
ISSUA NCE/REISSUANCE DATE: November 2014 1-003 Final Monthly Page I of I DEP Form 62-620.9 10(I0), Effective Nov 29, 1994
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Department of Environmental Protection, Wastewater Compliance Evaluation Section. MS 3551. 2600 Blair Stone Road, Tallahassee, FL 32399-2400 PERMIITEE NAME. Florida Power & Light (FPL) PERMIT NUMBER: FL0002208-01 t-IWB MAILING ADDRESS: 6501 S. Ocean Drive Jensen Beach, Florida 34957 LIMIT: Final REPORT FREQUENCY Annually CLASS SIZE: MA PROGRAM: Industrial FACILITY: St. Lucie Plant Units I and 2 MONITORING GROUP NUMBER: 1-003 LOCATION: Hutchinson Island. FL MONITORING GROUP DESCRIPTION Liquid radiation waste discharge to the discharge to the discharge canal to the Atlantic Ocean RE-SUBMITTED DMR: 0 NO DISCHARGE FROM SITE:
COUNTY: St. Lucie MONITORING PERIOD From: To:
OFFICE. Southeast District Parameter Quantity or Loading Units Quality or Concentration Units No. Frequency of Sample Type Ex Analysis Oil and Grease Sample Measurement PARM Code 00556 P Permit 150 200 mg/L Annually Grab Mon. Site No OUI-I Requirement (Mo Avg.) (Day.Mnax I I certify under penalty of law that this document and all attachments were prepared under my direction or supervasion in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is. to the best of my knowledge and belief, true, accurate, and complete. l am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations iMMENTLEXP ANTIPALOEXECUTIVEO FFICER ORAUTHORIZEDAGENT SIGNATUREOF PRINCIPALEXECUTIVEOFFICERORAUTHORIZEDAGENT TELEPHONErNO DATEmnsmdd/yvyv COMMENT AND EXPLANATION OF ANY VIOLATIONS (Referenceall attachments here):
ISSUANCE/REISSUANCE DATE November2014 1-003 Final Annually Page I of I DEP Form 62-620 9 10(10), Effective Nov 29. 1994
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Department of Environmental Protection, Wastewater Compliance Evaluation Section, MS 3551. 2600 Blair Stone Road, Tallahassee. FL 32399-2400 PERMITTEE NAME: Florida Power & Light (FPL) PERMIT NUMBER: FL0002208-01 6-IWB MAILING ADDRESS 6501 S. Ocean Drive Jensen Beach. Florida 34957 LIMIT Final REPORT FRE( 'UENCY Monthly CLASS SIZE MA PROGRAM. Industrial FACILITY: St Lucie Plant Units I and 2 MONITORING GROUP NUMBER: 1-005 LOCATION Hutchinson Island, FL MONITORING GROUP DESCRIPTION Steam generator blowdown to the discharge canal to the Atlantic Ocean.
RE-SUBMITTED DMR: El NO DISCHARGE FROM SITE: [C COUNTY St Lucie MONITORING PERIOD From To:
OFFICE. Southeast District Parameter Quantity or Loading Units Quality or Concentration Units No. Frequency of Sample Type Ex Analysis Flow Sample Measurement PARM Code 50050 P Permit Report Report MOD Weekly, when Calculated Mon Site No OUI-2 Requirement lMo.Avg.) (Day.Max.) discharging Oil and Grease Sample Measurement PARMuICode0O556 P Permit 15.0 20.0 mg/L Weekly, when Grab Mon. Site No. OUI-2 Requirement (Mo.AvR.) (Day.Max.) discharging Solids, Total Suspended Sample Measurement PARM Code 00530 P Permit 300 100.0 mg/L Weekly, when Grab Mon. Site No. OUI-2 Requirement (Mo.Avg.) (Day.Max.) discha*ging Hydrauine Sample Measurement PARM Code 81313 I Permit 0 .3 0 t mg/Il Weekly, when Grab Mon. Site No. EFF-2 Requirement (Day.Ma.) discharging Carbohydraztde Sample Measurement PARM Code 61916 I Permit Report' mg/L Weekly, when Grab Mon. Site No. EFF-2 Requirement (Day.Max.) discharging I certify under penalty of law that this document and all attachments were prepared under nty direction or supervision tnaccordance with a system designed to assare that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true. accurate, and complete I am aware that there are significant penalties for submitting false information, including the possibilty of fine and imprisonment for knowing violations.
NAMETITL E OPPICPAL EXECUTIVE OFFICER ORAUTHORIZED AGENT SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER Ge AUTHORIZED AGENT TELEPHONE NO DATElmnydd/yyvvi COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here):
See Permit Condition I.B.7 for how to calculate the Hydrazine concentration at EFF-2.
See Permit Condition I B 7 for how to calculate the Carbohydrazide concentration at EFF-2.
ISSUANCE/REISSUANCE DATE: November 2014 1-005 Final Monthly Page I of I DEP Form 62-620.910(10), Effective Nov. 29. 1994
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Department of Environmental Protection. Wastewater Compliance Evaluation Section. MS 3551. 2600 Blair Stone Road, Tallahassee. FL 32399-2400 PERMII'EE NAME Florida Power & Light (FPL) PERMIT NUMBER: FL0002208-016-1WB MAILING ADDRESS: 6501 S Ocean Drive Jensen Beach. Florida 34957 LIMIT. Final REPORT FRE( *UENCY: Monthly CLASS SIZE. MA PROGRAM: Industrial FACILITY: St Lucie Plant Units I and 2 MONITORING GROUP NUMBER: 1-008 LOCATION: Hutchinson Island, FL MONITORING GROUP DESCRIPTION: Evaporation percolation basin-industrial related stormwater to the intake canal.
RE-SUBMITTED DMR: 0i NO DISCHARGE FROM SITE: f]
COUNTY St Lucie MONITORING PERIOD From: To:
OFFICE. Southeast District Parameter Quantity or Loading Units Quality or Concentration Units No. Frequency of Sample Type Ex. Analysis Flow Sample Measurement PARM Code 50050 P Permit Report Report MGD Weekly, when Calculated Mon. Site No. OUI-5 Requirement (Mo.Avg (Daoy.Max.) discharging Solids. Total Suspended Sample Measurement PARM Code 00530 P Permit 300 1000 rg/L Weekly. when Gnah Mon. Site No. OUI-5 Requirement Mo.Ava.l (Day.Max.) discharging Oil and Grease Sample Measurement PARM Code 00556 P Permit 15 0 20 0 mg/L Weekly, when Grab Mon. Site No. OUI-5 Requirement (Mo.Avg.) (Day.Max.) discharging I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief. tane, accurate, and complete. I am aware thai there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
MMENiTE O P IPALEXECUTVEOFFICERORAUTHORIZED AGENT SIGNATURE OP PRINCIPAL EXECUTIVE OFICER ORAUTHORIZED AGENT TELEPHONE NO DAT COMMENT AND EXPLANATION OF ANY VIOLATIONS (Referenceall uatachments here):
ISSUANCE/REISSUANCE DATE November 2014 1-008 Final Monthly Page I of I DEP Form 62-620.910,(10). Effective Nov. 29. 1994
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Department of Environmental Protection, Wastewater Compliance Evaluation Section. MS 3551, 2600 Blair Stone Road, Tallahassee, FL 32399-2400 PERMITTEE NAME: Florida Power & Light (FPL) PERMIT NUMBER FL0002208-016-1WB MAILING ADDRESS 6501 S Ocean Drive Jensen Beach, Florida 34957 LIMIT: Final REPORT FREQ UENCY: Annually CLASS SIZE MA PROGRAM Industrial FACILITY St Lucie Plant Units I and 2 MONITORING GROUP NUMBER: 1-009 LOCATION. Hutchinson Island, FL MONITORING GROUP DESCRIPTION: Emergency Condensate and Component Cooling Water Pit Stormwater Discharge.
RE-SUBMITFED DMR: 0 NO DISCHARGE FROM SITE: '-
COUNTY St Lucie MONITORING PERIOD From To:
OFFICE: Southeast District Parameter Quantily or Loading Units Quality or Concentration Units No. Frequency of Sample Type Es. Analysis Flow Sample Measurement PARM Code 50050 P Permit Report Report MGD Per discharge Calculated Mon. Site No. OUI-6 Requirement (Day.Max.) (Mo.Avg.)
Oil and Grease Sample Measurement PARM Code 00556 P Permit 15.0 20.0 rng/L Per discharge Grab Mon. Site No. OUI-6 Requirement (Mo.Avg.) (Day.Max.)
Solids. Total Suspended Sample Measurement PARM Code00530 P Permit 30.0 100.0 g/L Per discharge Grab Mon. Site No. OUI-6 Requirement (Mo Avg.) (Day.Max.)
pH Sample Measurement PARM Code 00400 P Permit 6.0 9.0 ta. Per discharge Grab Mon. Site No. OUI-6 Requirement (Day.Min.) (Day.Max.)
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submuited is. to the best of my knowledge and belief, true,accurate, andcomplete. I am aware that there are significant penalties for submritting false information, including the possibility of fine and imprisonment for knowing violations MMEITLE OFP IPAL EXECUTIVE OFFICER ORAUTHORIZED AGENT SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER ORAUTHORIZED AGENT TELEPHONE NO DATErneddyy COMMENT AND EXPLANATION OF ANY VIOLATIONS (Referenceall attachmntens here)
ISSUANCEfREISSUANCE DATE November 2014 1.009 Final Annually Page I of I DEP Form 62-620.9 10( I0). Effective Nov 29, 1994
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Department of Environmental Protection, Wastewater Compliance Evaluation Section, MS 3551, 2600 Blair Stone Road, Tallahassee, FL 32399-2400 PERMITTEE NAME: Florida Power & Light (FPL) PERMIT NUMBER: FL0002208-016-IWB MAILING ADDRESS. 6501 S Ocean Drive Jensen Beach, Florida 34957 LIMIT: Final REPORT FREQ UENCY: Annually CLASS SIZE: MA PROGRAM Industrial FACILITY. St Lucie Plant Units I and 2 MONITORING GROUP NUMBER 1-06B LOCATION: Hutchinson Island, FL MONITORING GROUP DESCRIPTION: Former oil storage area industrial related storm wa ter to the intake canal.
RE-SUBMITTED DMR: 0 NO DISCHARGE FROM SITE: [)
COUNTY: St. Lucte MONITORING PERIOD From: To OFFICE: Southeast District Parameter Quantity or Loading Units Quality or Concentration Units No. Frequency of Sample Type E.. Analysis Flow Sample Measurement PARM Code 50050 P Permit Report Report MOD Annually Calculated Mon Site No. OUI-3 Peqairement l~o.Avg.) (Day Max.)
Solids, Total Suspended Sample Measurement PARM Code 00530 P Permit Report mgiL Annually Grab Mon. Site No. OUI-3 Requirement IDay.Mau.)
Oil and Grease Sample Measurement PARM Code 00556 P Permit Report ing/L Annually Grab Mon Site No. OUI-3 Requirement (Day Max I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the tnformation submitted Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief. true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possihility of fine and imprisonment for knowing violations ENtTL O IPALEXECUTIVE OFFICEROG AUTHORIZED AGENT SIGNATURE OF PRINCIPAL EXECUTIeE OFFICEROn AUTHO RIZEDAGENT TELEPHONE NO DATE(nsdd/yeyyy COMMENT AND EXPLANATION OP ANY VIOLATIONS (Referenceall attachmients here)
ISSUANCE/REISSUANCE DATE November2014 1-06B Final Annually Page I of I DEP Form 62-620.910( 10), Effective Nov. 29, 1994
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Department of Environmental Protection, Wastewatet Compliance Evaluation Section, MS 3551, 2600 Blair Stone Road. Tallahassee. FL 32399-2400 PERMITTEE NAME: Florida Power & Light (FPL) PERMIT NUMBER: FLOO02208-016-IWB MAILING ADDRESS: 6501 S Ocean Drive Jensen Beach. Florida 34957 LIMIT Final REPORT FREQ UENCY. Annulally CLASS SIZE: MA PROGRAM. Indust rial FACILITY. St. Lucie Plant Units I and 2 MONITORING GROUP NUMBER: 1-06C LOCATION: Hutchinson Island. FL MONITORING GROUP DESCRIPTION: Non-industrial related storm water to the Mangrove Impoundment 8E RE-SUBMITTED DMR. M NO DISCHARGE FROM SITE: F]
COUNTY St. Lucie MONITORING PERIOD From To:
OFFICE Southeast District Parameter Quantity or Loading Units Quality or Concentration Units No. Frequency of Sample Type Ex Analysis Flow Sample Measurement PARM Code 50050 P Permit Report Report MGD Annually Calculated Mon. Site No. OUI-4 Requirement (Mo.Av.) (Day.Max.)
Oil and Grease Sample Measurement PARMCode00556 P Permit Report .g/L Annually Grab Mon Site No. OUI-4 Requirement (Day.Max I I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is. to the best of my knowledge and beltef, true, accurate, and complete I am aware that there are signtficant penalties for submitting false tnformation, ncludtng the possibility of fine and imprisonment for knowing violations NAMETTLE OFPRINCIPAL EXECUTIVE OFFICER ORAUTHORIZED AGENT SIGNATUREaOF PRINCIPAL EXECUTIVE OFFICrER G AUTHORIZED AGENT TELEPHONE NO DATEemV nsdlvti COMMENT AND EXPLANATION OF ANY VIOLATIONS (Referenceall attachmentshere):
ISSUA NCE/REISS UANCE DATE: November 2014 I-06C Final Annually Page I of I DEP Form 62-620.910 f 10), Effective Nov 29. 1994
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Department of Environmental Protection, Wastewater Compliance Evaluation Section, MS 3551, 2600 Blair Stone Road, Tallahassee. FL 32399-2400 PERMITrEE NAME: Florida Power & Light (FPL) PERMIT NUMBER: FL0002208-016-IWB MAILING ADDRESS: 6501 S Ocean Drive Jensen Beach, Florida 34957 LIMIT. Final REPORT FREQUENCY: Annually CLASS SIZE MA PROGRAM: Industrial FACILITY St. Lucie Plant Units I and 2 MONITORING GROUP NUMBER: 1-009 LOCATION. Hutchinson Island, FL MONITORING GROUP DESCRIPTION: Emergency Condensate and Component Cooling Water Pit Stormvater Discharge RE-SUBMITTED DMR M NO DISCHARGE FROM SITE: El COUNTY: St Lucie MONITORING PERIOD From To:
OFFICE Southeast District Parameter Quantity or Loading Units Quality or Concentration Units No Frequency of Sample Type Es Analysis Flo. Sample Measurement PARM Code 50050 P Permit Report Report MGD Per discharge Calculated Mon Site No. OUI-6 Requirement lDay.Max.) (Mo.Avg)
Od and Grease Sample Measurement PARM Code 00556 P Permtt 15.0 20.0 m8/L Per discharge Grab Mon. Site No. OUI-6 Requirement (Mo.Avg.) (DayMa-.)
Solids. Total Suspended Sample Measurement PARM Code 00530 P Permit 30.0 1000 mg/L Per discharge Grab Mon. Site No. OUI-6 Requirement (Mo.Avg. (Day.Max.)
pH Sample Measurement PARM Code 00400 P Permit 6.0 9.0 s.o. Per discharge Grab Mon Site No OUI-6 Requirement (DayMin.) (Day.Max.)
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my tnqutry of the person or persons who manage the system. or those persons directly responsible for gathering the tnformation. the information submitted is. to the best of my knowledge and beltef, true. accurate, and complete I am aware that there are significant penalties for submioing false information, including the possibility of fine and imprisonment for knowing violations.
ONAME/TITLEOFPRINCtPALEXECUTIVEOFFICERORAUTHORIZEDAGENT Am/dd/ayyh e SIGNATUREOF PRINCIPAL EXECUTIVEOFFICERORAUTHORIZEDAGENT TELEPHONENO DATEO COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference all attachmentshere)
ISSUANCE/REISSUANCE DATE Novembei-2014 1-06C Final Annually Page I of I DEP Form 62-620 910(10I0.Effective Nov 29, 1994
INSTRUCTIONS FOR COMPLETING THE WASTEWATER DISCHARGE MONITORING REPORT Read these instructions before completing the DMR. Hard copies and/or electronic copies of the required parts ofthe DMR were provided with the permit. All required information shall be completed in full and typed or printed in ink. A signed, original DMR shall be mailed to the address printed on the DMR by the 28' of the month following the monitoring period. The DMR shall not be submitted before the end of the monitoring period The DMR consists of three parns--A, B, and D--all of which may or may not be applicable to every facility. Facilities may have one or more Parr A's for reporting effluent or reclaimed water data. All domestic wastewater facilities will have a Part B for reporting daily sample results Part D is used for reporting ground water monitoring well data.
When results are not available, the following codes should be used on parts A and D of the DMIRand an explanation provided where appropriate. Note Codes used on ParnB for raw data are different.
CODE DESCRIPTION/INSTRUCTIONS CODE DESCRIPTION/INSTRUCTIONS ANC Analysis not conducted. NOD No discharge fromi/to site DRY Dry Well OPS Operations were shutdown so no sample could be taken.
FLD Flood disaster. OTH Other. Please enter an explanation of why monitoring data were not available.
ITS Insufficient flow for sampling. SEF Sampling equipment failure.
LS Lost sample IMtNR Monitoring not required this period When reporting analytical results that fall below a laboratory's reported method detection limits or practical quantification limits, the following instructions should be used:
I. Results greater than or equal to the PQL shall be reported as the measured quantity.
- 2. Results less than the PQL and greater than or equal to the MDL shall be reported as the laboratory's MDL value These values shall be deemed equal to the MDL when necessary to calculate an average for that parameter and when determining compliance with permit limits
- 3. Results less than the MDL shall be reported by entering a less than sign ("<")followed by the laboratory's MDL value, e.g. < 0 001. A value of one-half the MDL or one-half the effluent limit, whichever is lower, shall be used for that sample when necessary to calculate an average for that parameter. Values less than the MDL are considered to demonstrate compliance with an effluent limitation.
PART A -DISCHARGE MONITORING REPORT (DM1R)
Part A of the DMR is comprised of one or more sections, each having its own header information. Facility information is preprinted in the header as well as the monitoring group number, whether the limits and monitoring requirements are interim or final, and the required submittal frequency le.g monthly, annually, quarterly, etc I. Submit Parr A based on the required reporting frequency in the header and the instructions shown in the permit. The following should be completed by the permittee or authorized representative Resubmitted DMR: Check this box if this DMR is being re-submitted because there was information missing from or information that needed correction on a previously submitted DMR. The information that is being revised should be clearly noted on the re-submirted DMR (e g. highlight, circle, etc.)
No Discharge From Site: Check this box if no discharge occurs and. as a result, there are no data or codes to be entered for all of the parameters on the DMR for the entire monitoring group nunmber:however, if the monitoring group includes other monitoring locations (e.g. influent sampling). the "NOD" code should be used io individually denote those parameters forwwhichthere was no discharge.
Monitoring Period: Enter the month, day. and year for the first and last day of the mortoring period (i e the month, the quarter, the year, etc.) during which the data on this report were collected and analyzed Sample Measurement: Before filling in sample measurements in the table, check to see that the data collected correspond to the limit indicated on the DMR (i.e. interim or final) and that the data correspond sothe morntoring group number in the header. Enter the data or calculated results for each parameter on this row in the non-shaded area above the trmot.Be sure the result being entered corresponds to the appropriate statistical base code (eg. annual average, monthly average, single sample maximum, etc.) and units.
No. Ex.: Enter the number of sample measurements during the monitoring period that exceeded the permit limit for each parameter in the non-shaded area. If none, enter zero Frequency of Analysis: The shaded areas in this column contain the minimum number of times the measurement is required to be made according to the permit. Enter the actual number of times the measurement was made in the space above the shaded area.
Sample Type: The shaded areas in this column contain the type of sample (e g grab, composite, continuous) required by the permit Enter the actual sample type that was taken in the space above the shaded area.
Signature: This report must be signed in accordance with Rule 62-620.305, F.A C. Type or print the name and title of the signing official. Include the telephone number where the official may be reached in the event there are questions concerning this report. Enter the date when the report is signed Comment and Explanation of Any Violations: Use this area to explain any exceedances, any upset or by-pass events. Or other items which require explanation If more space is needed, reference all attachments in this area
PART B - DAILY SAMPLE RESULTS Monitoring Period: Enter the month, day, and year for the first and last day of the monitoring period (i.e. the month, the quarter, the year, etc.) during which the data on this report were collected and analyzed Daily Monitoring Results: Transfer all analysical data from your facility's laboratory or a contract laboratory's data sheets for all day(s) that samples were collected. Record the data in the units indicated Table I in Chapter 62-160.
F.A.C. contains a complete list of all the data qualifier codes that your laboratorv may use when reporting analytical results. However, when transferring numerical results onto Part B of the DMIR. only the following data qualifier codes should be used and an explanation provided where appropriate.
CODE DESCRIPTION/INSTRUCTIONS
< The compound was analyzed for but not detected.
A Value reported is the mean (average) of two or more determinations.
J Estimated value, value not accurate Q Sample held beyond the actual holding time.
Ya Laboratory analysis was from an unpreserved or improperly preserved sample.
To calculate the monthly average. add each reported value to get a total. For flow. divide this total by the number of days in the month. For all other parameters, divide the total by the number ofobservations.
Plant Staffing: List the name. certificate number. and class of all state certified operators operating the facility during the monitoring period. Use additional sheets as necessary.
PART D - GROUND WATER MONITORING REPORT Monitoring Period: Enter the month, day, and year for the first and last day of the monitoring period (i.e the month, the quarter, the year, etc.) during which the data on this report were collected and analyzed.
Date Sample Obtained: Enter the date the sample was taken Also, check whether or not the well was purged before sampling.
Time Sample Obtained: Enter the time the sample was taken.
Sample Measurement: Record the results of the analysis If the result was below the minimum detection limit, indicate that.
Detection Limits: Record the detection limits of the analytical methods used Analysis Method: Indicate the analytical method used Record the method number from Chapter 62-160 or Chapter 62-601, F.AC., or from other sources.
Sampling Equipment Used: Indicate the procedure used to collect the sample (e g. airlift, bucket/bailer, centrifugal pump. etc.)
Samples Filtered: Indicate whether the sample obtained was filtered by laboratory (L), filtered in field (F), or unfiltered (N).
Signature: This report must be signed in accordance with Rule 62-620.305. F A.C Type or print the name and title of the signing official. Include the telephone number where the official may be reached in the event there are questions concerning this report Enter the date when the report is signed.
Comments and Explanation: Use this space to make any comments on or explanations of results that are unexpected If more space is needed, reference all attachments in this area.
SPECIAL INSTRUCTIONS FOR LIMITED WET WEATHER DISCHARGES Flow (Limited Wet Weather Discharge): Enter the measured average flow rate during the period of discharge or divide gallons discharged by duration of discharge (converted into days). Record in million gallons per day (MGD).
Flow (Upstream): Enter the average flow rate in the receiving stream upstream from the point of discharge for the period ofdischarge The average flow rate can be calculated based on two measarements: one made at the start and one made at the end of the discharge period. Measurements are to be made at the upstream gauging station described in the permit.
Actual Stream Dilution Ratio: To calculate the Actual Stream Dilution Ratio, divide the average upstream flow rate by the average discharge flow rate. Enter the Actual Stream Dilution Ratio accurate to the nearest 0. 1.
No. of Days the SDF > Stream Dilution Ratio: For each day of discharge, compare the minimum Stream Dilution Factor (SDF) from the permit to the calculated Stream Dilution Ratio On Part B of the DMR, enter an asterisk
(*) if the SDF is greater than the Stream Dilution Ratio on any day of discharge On Part A of the DMR, add up the days with an "*" and record the total number of days the Stream Dilution Factor was greater than the Stream Dilution Ratio.
CBOD1 : Enter the average CBOD, of the reclaimed water discharged during the period shown in duration of discharge.
TKN: Enter the average TKN of the reclaimed water discharged during the period shown in duration of discharge.
Actual Rainfall: Enter the actual rainfall for each day on Part B Enter the actual cumulative rainfall to date for this calendar year and the actual total monthly rainfall on Part A. The cumulative rainfall to date for this calendar year is the total amount of rain. in inches. that has been recorded since January I of the current year through the month for which this DMR contains data.
Rainfall During Average Rainfall Year: On Part A. enter the total monthly rainfall during the average rainfall year and the cumulative rainfall for the average rainfall year. The cumulautive rainfall for the average rainfall year is the amount of rain, in inches, which fell during the average rainfall year from January through the month for which this DMR contains data.
No. of Days LWWVD Activated During Calendar Year: Enter the cumulative number of days that the limited wet weather discharge was activated since January I of the current year.
Reason for Discharge: Attach to the DWR a brief explanation of the factors contributing to the need to activate the limited wet weather discharge.