L-2014-343, Response to Request for Additional Information Regarding License Amendment Request No. 216 - Transition to 10 CFR 50.48(c) - NFPA 805 Performance-Based Standard for Fire Protection for Light

From kanterella
(Redirected from L-2014-343)
Jump to navigation Jump to search
Response to Request for Additional Information Regarding License Amendment Request No. 216 - Transition to 10 CFR 50.48(c) - NFPA 805 Performance-Based Standard for Fire Protection for Light
ML14365A196
Person / Time
Site: Turkey Point  
Issue date: 12/02/2014
From: Kiley M
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML14365A188 List:
References
L-2014-343
Download: ML14365A196 (2)


Text

Florida Power & Light Company 9760 SW 344 St Homestead, FL 33035 0

December 2, 2014 FPL.

L-2014-343 10 CFR 2.390 10 CFR 50.90 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555-0001 Re:

Turkey Point Nuclear Generating Station Units 3 and 4 Docket Nos. 50-250 and 50-251 Response to Request for Additional Information Regarding License Amendment Request No. 216 - Transition to 10 CFR 50.48(c) - NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 Edition)

References:

1. Florida Power & Light Company letter L-2012-092, "Transition to 10 CFR 50.48(c) -

NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 Edition)," June 28, 2012.

2. Florida Power & Light Company letter L-2014-256, "Response to Request for Additional Information Regarding License Amendment Request No. 216 - Transition to 10 CFR 50.48(c) - NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 Edition)," September 12, 2014.

By Florida Power & Light Company (FPL) letter L-2012-092 dated June 28, 2012, (Reference 1) in accordance with the provisions of 10 CFR 50.90, "Application of License or Construction Permit," FPL requested an amendment to the Renewed Facility Operating License (RFOL) for Turkey Point Nuclear Generating Station Units 3 and 4. The License Amendment Request (LAR) will enable FPL to adopt a new fire protection licensing basis which complies with the requirements in 10 CFR 50.48(a) and (c) and the guidance in Revision 1 of Regulatory Guide (RG) 1.205..

The final risk estimates were provided to the NRC by FPL letter L-2014-256 (Reference 2).

The purpose of this letter is to provide a revision to Enclosure 1, Table W-6, PTN Fire Area Risk Summary (Unit 3), and Table W-7, PTN Fire Area Risk Summary (Unit 4), of Reference 1. To clarify the methodology used for calculating the Additional Risk of Recovery Actions (RAs), Note 1 of Tables W-6 and W-7 for the calculated ACDF/LERF is revised. Enclosure 1 to this letter provides pages W-27 and W-36 of Tables W-6 and W-7, respectively incorporating the revised Note 1. Enclosure 1 to this letter contains sensitive security-related information; therefore, FPL requests that it be withheld from public disclosure in accordance with 10 CFR 2.390.

The additional information provided in this letter does not impact the 10 CFR 50.92 evaluation of "No Significant Hazards Consideration" previously provided in FPL letter L-2012-092.

If you should have any questions regarding this application, please contact Robert Tomonto, Licensing Manager, at 305-246-7327.

Security-Related Information -Withhold From Public Disclosure Under 10 CFR 2.390. to this letter contains security-related information. Upon removal of Enclosure 1 this letter is uncontrolled.

L-2014-343 Page 2 of 2 I declare under penalty of perry that the foregoing is true and correct.

Executed on December 2 2014.

Michael Kiley Vice President Turkey Point Nuclear Generating Station Enclosure cc:

Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point USNRC Project Manager for Turkey Point Ms. Cindy Becker, Florida Department of Health Security-Related Information - Withhold From Public Disclosure Under 10 CFR 2.390. to this letter contains security-related information. Upon removal of Enclosure 1 this letter is uncontrolled.