0 Florida Power & *ght Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 FPL January 21, 2012 L-2011-036 10 CFR 50.4 EPP 3.2.4 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re: St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 Environmental Protection Plan Report Request for Minor Revision to IWW Permit No. FL0002208 Pursuant to Section 3.2.4 of the St. Lucie Environmental Protection Plan, Florida Power &
Light Company (FPL) is hereby providing the enclosed copy of the requested revision to the Industrial Wastewater Facility Permit (Permit Number FL0002208) at the same time that it is being submitted to the State of Florida Department of Environmental Protection.
Please contact Vince Munn6 (772) 263-2847 should you have any questions on this matter.
Sincerely, Eric S. Katzman Licensing Manager St. Lucie Plant ESK/kdr Enclosure an FPL Group company 14~-
Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 F=PL January 21, 2012 Marc Harris, P.E. CERTIFIED MAIL Florida Dept. of Environmental Protection RETURN RECEIPT REQUESTED Industrial Wastewater Section 7006 3450 0003 0174 4622 2600 Blair Stone Road, MS 3545 Tallahassee, Florida 32399-2400 RE: Florida Power & Light Company St. Lucie Power Plant Units 1 and 2 IWW Permit No. FL0002208 Request for Minor Revision Dear Mr. Harris Based on our review of the revised Industrial Wastewater Permit FL0002208 issued on September 29, 2011, St. Lucie is recommending several changes for your consideration. St. Lucie is requesting a Minor Revision to the permit to address typographical errors, wording changes, and clarifying statements and parameters in the printed monthly Discharge Monitor Report. Also requested is a due date extension for the Administrative Order AO022TL final reports to allow adequate time to properly evaluate project data.
The following enclosures are included herein:
- 1) Description of the change requests (Enclosure 1)
- 2) Three (3) signed copies of FDEP Form 62-620.910(9), Application for a Minor Revision to a Wastewater Facility or Activity Permit (Enclosure 2)
- 3) Mark-ups of the applicable permit and Discharge Monitoring Report text (Enclosure 3)
- 4) FPL check payable to the State of Florida, Department of Environmental Protection in the amount of $250.00 for the application fee (Enclosure 4)
If you have any questions or need additional information, please contact Vince Munne at (772) 263-2847.
Sincerely, Richard L. Anderson Site Vice president St. Lucie Plant VPPSL003 cc: Siting Office an FPL Group company
VPPSL003 Enclosure 1 Description of the Change Requests (1 page)
VPPSL003
- 1) General Conditions of the NPDES Permit, Section 22.b.3 reads - Permit Condition IX.22.b. The correct verbiage is Permit Condition IX.22.c
- 2) General Conditions of the NPDES Permit, Section 22.d reads - Permit Condition IX.22.a.1. The correct verbiage is Permit Condition IX.22.b.1.
- 3) After a review of the new Discharge Monitoring Report, several issues were identified that require clarification or wording changes. Listed below is an aggregate of the requested changes:
a.) For the Flow Parameter associated with Monitoring Group Number D-001, under Sample Type, it is requested that "Pump Curves" be changed to "Pump Logs" b.) For the Chlorination Duration parameter associated with Monitoring Group Number D-001, it is requested that a designated entry be provided in the report for both Unit I (U-I) and Unit 2 (U-2).
c.) For the Monitoring Group Description associated with Monitoring Group Number 1-003, it is requested that the caption after "MONITORING GROUP DESCRIPTION" be changed to, "Liquid radiation waste discharge to the discharge canal to the Atlantic Ocean".
- 4) FPL requests that the due dates for the final reports identified in Administrative Order AO022TL (Biological Plan of Study and Heated Water Plan of Study) be extended to 120 days to allow adequate time to properly evaluate project data.
VPPSL003 Enclosure 2 Three (3) Signed Copies of FDEP Form 62-620.910(9), Application for a Minor Revision to a Wastewater Facility or Activity Permit (6 pages)
APPLICATION FOR A MINOR REVISION TO A WASTEWATER FACILITY OR ACTIVITY A OM PERMIT
- 1. Instructions
- a. In accordance with Rule 62-620.325, F.A.C., this form must be submitted to the appropriate Department district office or approved local program when requests for minor revisions to a permit or minor modifications to a facility are made by a permittee, except for transfer of a permit to a new permittee and addition of a major user of reclaimed water to a Part III reuse system. Application for transfer of a permit to a new permittee shall be made on DEP Form 62-620.910(11). Application for addition of a major user of reclaimed water shall be made on DEP Form 62-610.300(4)(a)1.
- b. Each applicable item must be completed in full in order to avoid delay in processing ofthis form. Where attached sheets or other technical documentation are provided, indicate appropriate cross-references.
- c. Three (3) copies of this application with supporting documentation shall be submitted with this form.
- d. All information is to be typed or printed in ink. Dates are to be entered in MM/DD/YR format.
- e. This application and attachments shall be signed in accordance with Rule 62-620.305, F.A.C. Also, as applicable, this application and all attachments shall be signed and sealed by a professional engineer registered in Florida in accordance with Rule 62-620.3 10, F.A.C.
- 2. Facility Information
- a. Permit Number: FL0002208 b. Facility Identification Number:
- c. Project/Facility Name: St. Lucie Power Plant
- d. Contact Name: Vince Munne Number and Street: 6501 S. Ocean Drive City/State/Zip Code: Jensen Beach, FL 34957 Telephone 772-263-2847
- 3. Type of Revision ED Correct Typographical Errors' - Submit one copy of each page of the permit showing revisions being requested.
El Change Improvement Schedule' - Provide a description of the improvement, a list of the dates to be revised, and a reason for the proposed change in each date.
El Change Expiration Date of Permit' - Provide the current and proposed expiration dates for the permit and the reasons for the proposed change.
LI Change Staffing Requirements2 - Describe the proposed change and submit justification for the change in accordance with Chapter 62-699, F.A.C.
El Change Monitoring and Reporting Requirements 2 - Describe the proposed change and submit justification for the change in accordance with Chapter 62-601, F.A.C.
'Aprocessing fee isnot requirec. DEPForm 62-620.911)(9)
'Aprocessing fee isrequired withthe application Effective October 23, 2000 in accordancewith Rule62-4.050, F.A.C.
ED Modify Approved Pretreatment Program' - Describe the proposed modification and provide the information required by Rule 62-625.540, F.A.C.
ED Delete Point Source Outfall' - Identify the outfall and explain why the outfall is being eliminated.
[ Modify or Expand Approved Residuals Land Application Sites2 - Attach a new or updated Agricultural Use or Dedicated Site Plan as required by Chapter 62-640, F.A.C.
D Minor Modification to the Facility2 - Provide a description of the proposed modification, If applicable, attach any reports, plans, and specifications which have been developed to implement this modification.
[ Other 2 - Provide appropriate documentation. Describe.
- 4. Certifications
- a. Applicant or Authorized Representative I certify under penalty of law that I have personally examined and am familiar with the information submitted in this application and all attachments and that, based on my inquiry of persons immediately responsible for obtaining the information contained in the application, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imp sonment.
(Signature of Appli tat or Athorized Representative 3) (Date) I Name (please type) Richard L. Anderson Company Name FPL Title Site Vice President Company Address: 6501 S. Ocean Drive Phone: 772-467-7101 City/State/Zip Code: Jensen Beach, FL 34957
- b. Professional Engineer Registered in Florida I certify that the engineering features of this project have been (designed) (examined) by me and found to conform to engineering principles applicable to such projects. In my professional judgement, this facility, when properly constructed, operated, and maintained, will comply with all applicable statutes of the State of Florida and rules of the Department.
Name (please type): Not Required for this Revision Florida Registration Number:
Company Name:
Company Address:
City/State/Zip Code:
Phone Number:
(Seal, Signature, Date, and Registration Number)
'Ifsigned bythe authorzed representative, 2 DEP Form 62-620.910(9) attach a letterof aathoriatiron in accordance EffectiveOctober 23, 2000 Rlte 62-620.305, F.A.C.
APPLICATION FOR A MINOR REVISION TO vA WASTEWATER FACILITY OR ACTIVITY FoRn mPERMIT
- 1. Instructions
- a. In accordance with Rule 62-620.325, F.A.C., this form must be submitted to the appropriate Department district office or approved local program when requests for minor revisions to a permit or minor modifications to a facility are made by a permittee, except for transfer of a permit to a new permittee and addition of a major user of reclaimed water to a Part III reuse system. Application for transfer of a permit to a new permittee shall be made on DEP Form 62-620.910(11). Application for addition of a major user of reclaimed water shall be made on DEP Form 62-610.300(4)(a)1.
- b. Each applicable item must be completed in full in order to avoid delay in processing of this form. Where attached sheets or other technical documentation are provided, indicate appropriate cross-references.
- c. Three (3) copies of this application with supporting documentation shall be submitted with this form.
- d. All information is to be typed or printed in ink. Dates are to be entered in MM/DD/YR format.
- e. This application and attachments shall be signed in accordance with Rule 62-620.305, F.A.C. Also, as applicable, this application and all attachments shall be signed and sealed by a professional engineer registered in Florida in accordance with Rule 62-620.310, F.A.C.
- 2. Facility Information
- a. Permit Number: FL0002208 b. Facility Identification Number:
- c. Project/Facility Name: St. Lucie Power Plant
- d. Contact Name: Vince Munne Number and Street: 6501 S. Ocean Drive City/State/Zip Code: Jensen Beach, FL 34957 Telephone 772-263-2847
- 3. Type of Revision
[ Correct Typographical Errors' - Submit one copy of each page ofthe permit showing revisions being requested.
D Change Improvement Schedule' - Provide a description of the improvement, a list of the dates to be revised, and a reason for the proposed change in each date.
ED Change Expiration Date of Permit' - Provide the current and proposed expiration dates for the permit and the reasons for the proposed change.
ED Change Staffing Requirements2 - Describe the proposed change and submit justification for the change in accordance With Chapter 62-699, F.A.C.
E] Change Monitoring and Reporting Requirements 2 - Describe the proposed change and submit justification for the change in accordance with Chapter 62-601, F.A.C.
'A processing fee is not required 1 DEP Formn62-620.910(9)
'A processing fee is requiredwith theapplication EFfeti- Octoe 23, 2000 in accordance oith Rule624.050, F.A.c.
E] Modify Approved Pretreatment Program' - Describe the proposed modification and provide the information required by Rule 62-625.540, F.A.C.
El Delete Point Source Outfall1 - Identify the outfall and explain why the outfall is being eliminated.
ED Modify or Expand Approved Residuals Land Application Sites2 - Attach a new or updated Agricultural Use or Dedicated Site Plan as required by Chapter 62-640, F.A.C.
D] Minor Modification to the Facility2 - Provide a description of the proposed modification. If applicable, attach any reports, plans, and specifications which have been developed to implement this modification.
[ Other 2 - Provide appropriate documentation. Describe.
- 4. Certifications
- a. Applicant or Authorized Representative I certify under penalty of law that I have personally examined and am familiar with the information submitted in this application and all attachments and that, based on my inquiry of persons immediately responsible for obtaining the information contained in the application, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possib of fine and imprisonr~nt.
(Signatu~re of Applicant or Authorizd Rersettie Rersettive3) (Date)
(Date)
Name (please type) Richard L. Anderson Company Name FPL Title Site Vice President Company Address: 6501 S. Ocean Drive Phone: 772-467-7101 City/State/Zip Code: Jensen Beach, FL 34957
- b. Professional Engineer Registered in Florida I certify that the engineering features of this project have been (designed) (examined) by me and found to conform to engineering principles applicable to such projects. In my professional judgement, this facility, when properly constructed, operated, and maintained, will comply with all applicable statutes of the State of Florida and rules of the Department.
Name (please type): Not Required for this Revision Florida Registration Number:
Company Name:-
Company Address:
City/State/Zip Code:
Phone Number:
(Seal, Signature, Date, and Registration Number)
'If signedbythe authorized representative, 2 DEPForm62-62M.91(9) attacha letter of authorizationin accordance EffectiveOctober 23, 2000 RuLe62-620,305. FA.C.
APPLICATION FOR A MINOR REVISION TO A WASTEWATER FACILITY OR ACTIVITY
.... ..... PERMIT
- 1. Instructions
- a. In accordance with Rule 62-620.325, F.A.C., this form must be submitted to the appropriate Department district office or approved local program when requests for minor revisions to a permit or minor modifications to a facility are made by a permittee, except for transfer of a permit to a new permittee and addition of a major user of reclaimed water to a Part III reuse system. Application for transfer of a permit to a new permittee shall be made on DEP Form 62-620.910(11). Application for addition of a major user of reclaimed water shall be made on DEP Form 62-610.300(4)(a)1.
- b. Each applicable item must be completed in full in order to avoid delay in processing of this form. Where attached sheets or other technical documentation are provided, indicate appropriate cross-references.
- c. Three (3) copies of this application with supporting documentation shall be submitted with this form.
- d. All information is to be typed or printed in ink. Dates are to be entered in MMvI/DD/YR format.
- e. This application and attachments shall be signed in accordance with Rule 62-620.305, F.A.C. Also, as applicable, this application and all attachments shall be signed and sealed by a professional engineer registered in Florida in accordance with Rule 62-620.310, F.A.C.
- 2. Facility Information
- a. Permit Number: FL0002208 b. Facility Identification Number:
- c. Project/Facility Name: St. Lucie Power Plant
- d. Contact Name: Vince Munne Number and Street: 6501 S. Ocean Drive City/State/Zip Code: Jensen Beach, FL 34957 Telephone 772-263-2847
- 3. Type of Revision
[ Correct Typographical Errors' - Submit one copy of each page of the permit showing revisions being requested.
El Change Improvement Schedule' - Provide a description of the improvement, a list of the dates to be revised, and a reason for the proposed change in each date.
ED Change Expiration Date of Permit' - Provide the current and proposed expiration dates for the permit and the reasons for the proposed change.
LI Change Staffing Requirements 2 - Describe the proposed change and submit justification for the change in accordance with Chapter 62-699, F.A.C.
FI Change Monitoring and Reporting Requirements 2 - Describe the proposed change and submit justification for the change in accordance with Chapter 62-601, F.A.C.
'A processing fee isnot required. 1 DEPForm 62-620,910(9) 2Aprocessing fee isrequiredwiththe application EffectiveOctober 23,2000 in accordencewithRule 624.050, FAC.
D Modify Approved Pretreatment Program' - Describe the proposed modification and provide the information required by Rule 62-625.540, F.A.C.
D Delete Point Source Ouffall' - Identify the outfall and explain why the outfall is being eliminated.
ED Modify or Expand Approved Residuals Land Application Sites' - Attach a new or updated Agricultural Use or Dedicated Site Plan as required by Chapter 62-640, F.A.C.
El Minor Modification to the Facility2 - Provide a description of the proposed modification. If applicable, attach any reports, plans, and specifications which have been developed to implement this modification.
[ Other 2 - Provide appropriate documentation. Describe.
- 4. Certifications
- a. Applicant or Authorized Representative I certify under penalty of law that I have personally examined and am familiar with the information submitted in this application and all attachments and that, based on my inquiry of persons immediately responsible for obtaining the information contained in the application, I believe that the information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possi ty of fine and impris ent.
(Signraure of Applicda or Authorized Representative3) (Date) (
Name (please type) Richard L. Anderson Company Name FPL Title Site Vice President Company Address: 6501 S. Ocean Drive Phone: 772-467-7101 City/State/Zip Code: Jensen Beach, FL 34957
- b. Professional Engineer Registered in Florida I certify that the engineering features of this project have been (designed) (examined) by me and found to conform to engineering principles applicable to such projects. In my professional judgement, this facility, when properly constructed, operated, and maintained, will comply with all applicable statutes of the State of Florida and rules of the Department.
Name (please type): Not Required for this Revision Florida Registration Number:
Company Name:
Company Address:
City/State/Zip Code:
Phone Number:
(Seal, Signature, Date, and Registration Number)
'If signed bytheauthorizedrepresentative, 2 DSPForn,62-620910(9) attach a letterof authorization in accordance EffectiveOctober 23, 2000 Rule 62-620,305, F.A.C.
VPPSL003 Enclosure 3 Mark-ups of the Applicable Permit and Discharge Monitoring Report Text (3 pages)
r PERMITTEE: Florida Power & Light (FPL) PERMIT NUMBER: FL0002208 (Major)
FACILITY: St. Lucie Power Plant EXPIRATION DATE: September 28, 2016
- c. If the oral report has been received within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />, tihe nonconipliance has been corrected,.and the noncompliance-did not endanger health or the environment, the Department's Southeast District Office shall waive the written report.
[62-620.610(20)]
- 21. The permittee shall report all instances of noncompliance not reported under Permit Conditions IX. 17i 18 or 19 of this permit at the time monitoring reporis are submitted. This report shall contain the same information required by Perlmit Condition iX,.20 of this permit. [62-620.610(21)]
- 22. Bypass Provisions.
- a. Bypass'* means the ifitenti6inal diversion of waste streams from any portion of a tr'eatment works.
- b. Bypass isprohibited, and the Depairtment. may take enforcement action agahist a permittee for bypass, unless the: perm ittee affirmatively demohstrates that:
(I) Bypass was unavoidable to prevent loss of life, personal injury, or severe property damage; and (2) There were no feasible alter'natives to the bypass, such a, h Ise fa a tretmentf acihities re ention ofuntreated wastes, or mnintenance during normnal pe* ace IX.22.b" l . . ot satisfied if adequatelback-up equipment should have b " ..... w i- ..
engineering judgment to prevent a bypass which occurred during norma.period of equipment downtime or preventivejmaintenance; and (3) The permittee submitted notices as required under Permit Conditi IX.22;b f this permit.
- c. If the pernihteeiknowis in advance of the need for a bypass, it shltibi ti-ce to the Department, if possible at least, 10 days before the date of the bypass. The permittee shall submbit notice of an tunanticipated bypass within'24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of learhing about the bypass as required iin Permit Condition IX.20. of this permit. A notice shall include a description ofthe bypass and its Cans times; if the bypass has not been corrected, the anticipated Replace "IX22.a.1 with *X.22.b. 1 -
planned to reduce, eliminate, and prevent recurrence of tle
- d. The Department shall approve an anticipated bypass, after considering its e if the p6rmittee demonstrates that it will meet the three conditions listed in PermitConditi ilX.22.an. irough3ofthis permit.
- e. A pcrimittee may allow any bypass to occur which does not cause reclaime -e fluent limitations to be exceeded if it is for essential maintenance to assure efficient operation. These bypasses are not subject to the provisions of Permit Condition IX.22.a. through c. of this permit.
[62-620.610(22)]
- 23. Upset Provisions.
- a. "Upset" means an exceptional incident in which there is unintentional and temporary noncompliance with technology-based effluent limitations because of factors beyond the reasonable control of the penrittee.
(I) An upset does not include noncompliance caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventive maintenance, careless or improper operation.
(2) An upset constitutes an affirmative defense to an action brought for noncompliance with technology based permit effluent limitations if the requirements of upset provisions of Rule 62-620.610, F.A.C., are met.
- b. A permittee who wishes to establish the affirmative defense of upset shall demonstrate, through properly signed contemporaneous operating logs, or other relevant evidence that:
(I) An upset occurred and that the permittee can-identify the cause(s) of the upset; (2) The permitted facility was at the time being properly operated; (3) Thepermittee submitted notice of the upset as required in Permit Condition IX.5. of this permit; and (4) The pernittee complied with any-remedial measures required under Permit Condition IX.5. of this permit.
- c. In any enforcement proceeding, the burden of proof for establishing the occurrence of an upset rests with the pennittee.
- d. Before an enforcement proceeding is instituted, no representation made during the Department review of a claim that noncompliance was caused by an upset is final agency action subject to judicial review.
24
40 DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT- PART A When Completed mail this report to: Department of Environmental Protection, Wastewater Compliarce Evaluation Section, MS 3551, 2600 Blair Stone Road, Tallahassee; FL 32399-2400 PERMITTEE NAME: Florida Power & Light (FPL) PERMIT NUMBER: FL,000220S-01 -IWlS MAILING ADDRESS: 6501 S. Ocean Drive Jensen Beach, Florida 34957 LIMIT: Final REPORT FREQUENCY: Monthly CLASS SIZE: MA PROGRAM: Industrial FACILITY: St Lucie Plant Units 1 and 2 MONITORING GROUP NUMBER: D-001 LOCATION: Hutchinson Island, FL MONITORING GROUP DESCRIPTION: Condenser once-through cooling wate and auxiliary equipment cooling water from Units I and 2 to the discharge canal thence the Atlantic Ocean.
RE-SUBMITTED DMR: r NO DISCHARGE FROM SITE: "
COUNTY: St. Lucie MONITORING PERIOD From: To:, Replace "Curves" with "Logs" OFFICE: Southeast District Parameter Quantity or Loading Units Quality or Concesation Units No. Free wcy of Sample Type
_ _ _ _ _EX. Anal-i, Flow Sample Measurement PARM Code 50050 1 Permit Report MO- Hourly p Curv Mon. Site No. FLW-1 Requirement (Day-,Max) .______ _ ___ _
Temperature (F)nWater Sample (During Normal Operation) Measurement PARM Code 00011 1 Permit Report DegF Hourly Recorder Mon. Site No- EFF-2 Requ.ireme. _ (Da_.M__._
Temperature (F), Water Sample (During Maintenance Activities) Mea emnt PARM Code 000I1 Q Permit 117 Deg F Hourly Recorder Mon. Site No, EFF-2 Requirement _ayMax_)
Temp. Diff. between Intake and Sample Discharge (During Normal Operation) Measurement PARM Code 61576 1 Permit 30 DegF Hourly Calculated Mon. Site No. EFF-2 Requirement (Day.M__)
Temp. Diff. between Intake aid Sample Discharge Measurement (Duing Maintenance Activi'tis)
PARM Code 61576 Q Permit 32 DegF Hourly Calculated Mon. Site No. EFF-2 Requirement (Day-Max.)
Oxidants, Total Residual Sample MeasurementYY PARM Code 34044 I Permit Provide entries for both U-1 and U-2 0.1 0.1 mg/L Continuous Recorder o_.__to.___________"Ao.Av (Day.Max,)
Chlorination Du~ration Sample
- Measurement PARi Code 78739 1 Permit 120 min Daily; 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Logs Mon. Site No. EFF-1 PcquxrerWet (Day.Max.)
a hts were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry ofthe person or persons who manage the system, or those persons directly responsible for gathering the information. the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware thatthere are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations.
NAMEITITLE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHOtIZD AGENT SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT TELEPHONE NO DATE (mm/dd/yy)
COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here):
ISSUANCE/RIEISSUANCIEDAT'E: September201I D-001 Final Monthly Page I of 2 DEP Form 62-620.910(10), Effective Nov. 29,1994
DEPARTMENT OF ENVIRONMENTAL PROTECTION DISCHARGE MONITORING REPORT - PART A When Completed mail this report to: Departnment ofEnvirormnental Protection, Wastewater Compliance Evaluation Section, MS 3551,2600 Blair Stone Road, Tallahassee, FL 32399-2400 PERMITTEE NAME: Florida Power & Light (FPL) PERMIT NUMBER. FL0002208-011-IWIS MAILING ADDRESS: 6501 S. Ocean Drive Jensen Beach, Florida 34957 LIMIT: Final REPORT FREQUENCY: Annually CLASS SIZE: MA PROGRAM: Industrial FACILITY: St Lucie Plant Units I and 2 MONITORING GROUP NUMBER: 1-003 LOCATION: Hutchinson Island, FL MONITORING GROUP DESCRIPTION: Liquid radiation waste dischs to the discharge the discharge canal to the Atlantio Ocean-RE-SUBMfTTED DMR. 11 NO DISCHARGE FROM SITE: 0l COUNTY: St. Lucie MONITORING PERIOD From:
OFFICE: Southeast District Delete dpiae to the discharge" Parameter Quantity or Loading Units Quality or Concetration Units No. Frequency of Sample Type
___ Ex. Analysis Sample Oil and Grease Measurement PARM Code 00556 P Permit 15.0 20.0 mg,-0 Annually Grab Mon. Site No. OU-I- Requirement (Mo.Avg.) _(Day.M-_.)
I certify under penalty of law thattbis document and all attachments were prepared uder my direction or supervision in accordance with a system designed to assure That qualified persormel properly gather aid evaluate the information submitted. Based on my inquiry of the person orpersons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, ,curate, and complete. I am aware that there are significant pcnaltics for submitting false information, including the possibility offine and imprisonment for knowing violations.
NAMErTITLE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT SIGNATURE OF PRINCIPAL EXECUTTVE OFFICER OR AUTHORIZED AGENT TELEPHONE NO DATE (/dd/-yyy)
COMMENT AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here):
ISSUANCEIREISSUANCE DATE: Septernber201 I 1-003 Final Annually Page I of E Form 62-620.910(10), Effective Nov. 29,1994 DEP
VPPSL003 Enclosure 4 FPL Check Payable to the State of Florida, Department of Environmental Protection in the Amount of $250.00 for the Application Fee (1 page)