L-2003-254, Core Operating Limits Report for Cycle 21
| ML033030425 | |
| Person / Time | |
|---|---|
| Site: | Turkey Point |
| Issue date: | 10/20/2003 |
| From: | Jones T Florida Power & Light Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-2003-254 | |
| Download: ML033030425 (4) | |
Text
FPL OCT 2 0 2003 L-2003-254 10 CFR 50.36 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Re:
Turkey Point Unit 4 Docket No. 50-251 Core Operating Limits Report In accordance with Technical Specification 6.9.1.7, the attached Core Operating Limits Report is provided for Turkey Point Unit 4. These curves are applicable for Unit 4 Cycle 21.
Should there be any questions, please contact Walter Parker, Licensing Manager, at 305-246-6632.
Very truly yours, Terry
. ones Vice President Turkey Point Nuclear Plant 01H Attachment NRC Regulatory Issue Summary 2001-05 waived the requirements that multiple copies of documents be submitted to the NRC
-Aco 1.
an FPL Group company
Attachment to L-2003-254 Page 1 of 3 CORE OPERATING LIMITS REPORT - UNIT 4 CYCLE 21 The Technical Specifications (TS) affected by this report are:
3.1.3.2 Analog Rod Position Indication System 3.1.3.6 Control Rod Insertion Limits 3.2.1 Axial Flux Difference (AFD) 3.2.2 Heat Flux Hot Channel Factor - FQ(Z) 3.2.3 Nuclear Enthalpy Rise Hot Channel Factor - FISH The Control Rod Insertion Limits, AFD, FQ(Z), K(Z), and FISH have been developed using the NRC approved methodology specified in TS 6.9.1.7.
TS 3.1.3.2 Analog Rod Position Indication System The All Rods Out position for all Shutdown Banks and Control Banks is defined to be 230 steps withdrawn.
TS 3.1.3.6 Control Rod Insertion Limits The control rod banks shall be limited in physical insertion as shown on page 2 for All Rods Out = 230 steps withdrawn.
TS 3.2.1 Axial Flux Difference The AFD limits are provided on page 3.
TS 3.2.2 Heat Flux Hot Channel Factor - FQ(Z)
FQ] =2.50 K(Z) = 1.0 for 0 ft. < z < 12 ft. where z = core height.
TS 3.2.3 Nuclear Enthalpy Rise Hot Channel Factor RTP = 1.70 FAH PF&H = 0.3
Attachment to L-2003-254 Page 2 of 3
(_
i-In 0.
E 0
0.
0 cr A:
r_
230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0
Figure Al Turkey Point Unit 4 - Cycle 21 Rod Insertion Limit vs Thermal Power ARO = 230 Steps Withdrawn, Overlap= 102 Ste s 64.5, 30) __
( 00,171)
-,-,105).
=
=
=
=
=
=
=~~~~~-01 Be nk Dl 0
10 20 30 40 50 60 70 80 90 100 Percent Reactor Power
I
. e e
Attachment to L-2003-254 Page 3 of 3 Figure A2 Axial Flux Difference as a Function of Rated Thermal Power Turkev Point Unit 4 - Cycle 21 120 100 Uj 0
al
-z w
0 O.-0 4-0CU a.
80 60 40 20 0
-50
-40
-30
-20
-10 0
10 Axial Flux Difference (%)
20 30 40 50