L-2003-132, Steam Generator Tube Plugging Report
| ML031490089 | |
| Person / Time | |
|---|---|
| Site: | Saint Lucie |
| Issue date: | 05/26/2003 |
| From: | Jefferson W Florida Power & Light Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-2003-132 | |
| Download: ML031490089 (1) | |
Text
0 FPL Florida Power & Light Company, 6501 S. Ocean Drive, Jensen Beach, FL 34957 May 26, 2003 L-2003-1 32 10 CFR 50.36 10 CFR 50.4 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:
St. Lucie Unit 2 Docket No. 50-389 Special Report Steam Generator Tube Pluging Report This letter is being sent pursuant to St. Lucie Unit 2 Technical Specification 4.4.5.5.a. The number of tubes plugged in each steam generator during the Unit 2 refueling outage (SL2-14) is listed below.
Steam Generator 2A - 197 Steam Generator 2B - 333 Cumulative tubes plugged during this outage and previous outages:
Steam Generator 2A - 671 Steam Generator 2B - 872 Please contact us should you have any questions regarding this information.
William effersc Vice President St. Lucie Plant WJ/spt A 4D1 an FPL Group company