L-11-227, Emergency Response Data System Data Point Library Update

From kanterella
Jump to navigation Jump to search
Emergency Response Data System Data Point Library Update
ML11201A002
Person / Time
Site: Beaver Valley
Issue date: 07/14/2011
From: Harden P
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-11-227
Download: ML11201A002 (28)


Text

FENOC FirstEnergy Nuclear Operating Company Beaver Valley Power Station P.O. Box 4 Shippingport, PA 15077 Paul A. Harden Site Vice President 724-682-5234 Fax: 724-643-8069 July 14, 2011 L-1 1-227 10 CFR 50, Appendix E, Section VI ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit Nos. 1 and 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No. NPF-73 Emergency Response Data System Data Point Library Update In accordance with 10 CFR 50, Appendix E, Section VI, an update of the Emergency Response Data System (ERDS) Data Point Library (DPL) for Beaver Valley Power Station, Unit Nos. 1 (BV1) and 2 (BV2) is provided. An attachment provides the details regarding each change and copies of updated DPL pages are enclosed.

There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager -

Fleet Licensing, at 330-761-6071.

Sincerely, 4P'.

a~rden

>Yv1/4r

Attachment:

Summary of Changes to Data Point Library (DPL)

Enclosure:

Updated Data Point Library Pages cc:

NRC Region I Administrator NRC Resident Inspector NRC Project Manager (w/o enclosures)

Director BRP/DEP Site BRP/DEP Representative

ýog ('C/

ý- I L 41

ý-

Attachment L-11-227 Summary of Changes to Data Point Library (DPL)

Page 1 of 2 Reactor DPL Description of Change(s)

Unit Point BV1 Y0735A Engr Units/Dig States: changed from: "MR/HR" to: "mR/HR" BV1 XR006 Alarm/Trip Set Points: changed from: "HIGH <= 669 CPM

>BACKGROUND" to: "HIGH <= 642 CPM >BACKGROUND" BV1 XR007 Alarm/Trip Set Points: changed from: "13.2" to: "10.8" BV1 XR010 Alarm/Trip Set Points: changed from: "HIGH <= 798 CPM

>BACKGROUND" to: "HIGH <= 766 CPM >BACKGROUND" BV1 XR011 Alarm/Trip Set Points: changed from: "22.8" to: "18.6" BV1 XR015 Alarm/Trip Set Points: changed from: "HIGH 1.83E5 CPM

>BACKGROUND" to: "HIGH 1.76E5 CPM >BACKGROUND" BV2 R0002A Minimum Instr Range: changed from: "0" to "1.0E-3" Maximum Instr Range: changed from: "1.0E2" to "1.0E4" BV2 R0003A Minimum Instr Range: changed from: "0.0" to "1.0E-1" Maximum Instr Range: changed from: "1.0E5" to "1.0E6" BV2 R0010A Minimum Instr Range: changed from: "0" to "1.0E-7" BV2 R0079A Minimum Instr Range: changed from: "0.0" to "1.0E-8" Maximum Instr Range: changed from: "1.0" to "1.OE-1" BV2 R0086A Minimum Instr Range: changed from: "0.0" to "1.0E-1" Maximum Instr Range: changed from: "1 E9" to "1.0E8" BV2 R0087A Minimum Instr Range: changed from: "0.0" to "1.0E-1" Maximum Instr Range: changed from: "1E9" to "1.0E8" BV2 R0088A Minimum Instr Range: changed from: "0.0" to "1.0E-3" BV2 R0089A Minimum Instr Range: changed from: "0.0" to "1.0E-3"

Attachment L-1 1-227 Page 2 of 2 Reactor DPL Description of Change(s)

Unit Point BV2 R0090A Minimum Instr Range: changed from: "0.0" to "1.OE-3" BV2 R0094A Minimum Instr Range: changed from: "0.0" to "1.OE-8" BV2 XR015 Alarm/Trip Set Points: changed from: "HIGH 1.83E5 CPM

>BACKGROUND" to "HIGH 1.76E5 CPM >BACKGROUND" BV2 XR041 Generic/Cond Desc: changed from: "RADIOACTIVITY OF RELEASED GASSES" to: "RADIOACTIVITY OF RELEASED PARTIC" Minimum Instr Range: changed from: "5.6E-1 1" to "3.24E-1 0" Maximum Instr Range: changed from: "5.6E-5" to "3.24E-4" Alarm/Trip Set Points: changed from: "HIGH 1.67E-5 uCi/cc

>BACKGROUND" to: "HIGH 9.71E-5 uCi/cc >BACKGROUND" BV2 XR042 Maximum Instr Range: changed from: "0.37" to "0.372" BV2 XR045 Generic/Cond Desc: changed from: "RADIOACTIVITY OF RELEASED GASSES" to: "RADIOACTIVITY OF RELEASED PARTIC" Minimum Instr Range: changed from: "3.3E-1 1" to "3.24E-1 0" Maximum Instr Range: changed from: "3.3E-5" to "3.24E-4" Alarm/Trip Set Points: changed from: "HIGH 9.84E-6 uCi/cc

>BACKGROUND" to: "HIGH 2.59E-4 uCi/cc >BACKGROUND" BV2 XR046 Minimum Instr Range: changed from: "2.45E-7" to "2.5E-7" Maximum Instr Range: changed from: "1.0E+5" to "8.9E+4" Alarm/Trip Set Points: changed from: "HIGH 1.77E3 uCi/SEC" to: "N/A" BV2 XR053 Alarm/Trip Set Points: changed from "HIGH 3.9E-2 uCi/cc

>BACKGROUND" to "N/A" BV2 XR054 Alarm/Trip Set Points: changed from "HIGH 3.9E-2 uCi/cc

>BACKGROUND" to "N/A" BV2 XR055 Alarm/Trip Set Points: changed from "HIGH 3.9E-2 uCi/cc

>BACKGROUND" to "N/A"

Enclosure L-1 1-227 Updated Data Point Library Pages (24 pages follow)

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

7/7/2011 Reactor Unit:

BV1 Data Feeder:

IPC NRC ERDS Parameter:

EXTRA19 Point ID:

Y0735A Plant Spec Point Desc.:

CONTAINMENT LOW RNG RIS-1RM-202 Generic/Cond Desc.:

RADIATION LEVEL IN CONTAINMENT Analog/Digital:

A Engr Units/Dig States:

mRIHR Engr Units Conversion:

N/A Minimum Instr Range:

0.1 Maximum Instr Range:

10000 Zero Point

Reference:

N/A Reference Point Notes:

N/A PROCorSENS:

S Number of Sensors:

1 How Processed:

N/A Sensor Location:..SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Tdp Set Points:

SEE UNIT 1 RMS SETPOINT LOG NI Detector Power Supply Cut-Off Power Level:

N/A NI Detector Power Supply Turn-ON Power Level:

N/A Instrument Failure Mode:

LOW Temperature Compensation for DP Transmitters:

N Level Reference Leg:

N/A Unique System Desc.:

RM-1RM-202 monitors the radiation level inside Containment and warns personnel of an increase in the radiation level. A geiger-mueller detector monitors radiation level inside the Containment Crane Wall opposite the personnel access. Ref: Op Manual Chapter 43 1-67

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Thp Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/7/2011 BV1 ARERAS EFF-GAS-RAD2 XR006 1RM-VS-109 CH7 RADIOACTIVITY OF RELEASED GASSES A

CPM Xe133=3.54E2 CPM/uCl/cc 1.0 1.2E6 N/A N/A S

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH <= 642 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N

N/A Point is 1 minute average. Site doseassessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to a General Emergency for eight hours.

RM-1VS-109 Chapnel 7 monitors for mid range noble gases at the discharge of the Auxiliary Building Shielded Area Exhaust Fans and at the discharge of the Containment Refueling and Purge Exhaust Fan (during refueling). This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-79

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/7/2011 BV1 ARERAS EFF-GAS-RAD3 XR007 1RM-VS-109 CH9 RADIOACTIVITY OF RELEASED GASSES A

CPM Xel33=3.95 CPM/uCl/cc 1.0 1.2E6 N/A N/A S

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD 10.8 N/A N/A DEPENDS ON FAILURE MODE N

N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. RM-1VS-109 Channel 9 monitors for high range noble gases at the

.discharge of the Auxiliary Building Shielded Area Exhaust Fans and at the discharge of the Containment Refueling and Purge Exhaust Fan (during refueling). This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data.

Ref: Op Manual Chapter 43; RM-416-1; Calculation Package ERS-SFL 024; CR 04L05484 1-80

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Des'c.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

.7/7/2011 BV1 ARERAS EFF-GAS-RAD5 XR010 1RM-VS-110 CH7

-RADIOACTIVITY OF RELEASED GASSES A

CPM Xe133=3.01E2 CPM/uCI/cc 1.0 1.2E6 N/A N/A S

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH <= 766 CPM >BACKGROUND N/A N/A DEPENDSON FAILURE MODE N

N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to a General Emergency if the release continues 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. RM-1VS-1110 Channel 7 monitors for mid range noble gases at the discharge of the Leak Collection Area Exhaust Fans before the Elevated Release Vent. This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-82

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero.Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

  • 7/7/2011 BV1 ARERAS:

EFF-GAS-RAD6 XR011 1RM-VS-110 CH9 RADIOACTIVITY OF RELEASED GASSES A

CPM Xel33=4.87 CPM/uCI/cc 1.0 1.2E6 N/A N/A S

1 i

N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD 18.6 N/A N/A DEPENDS'ON FAILURE MODE N

N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. RM-1VS-110 Channel 9 monitors for high range noble gases at the discharge of the Leak Collection Area Exhaust Fans before the Elevated Release Vent. This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data.

Ref: Op Manual Chapter 43; RM-416-1; Calculation Package ERS-SFL 024; CR 04-05484 1-83

BEAVER VALLEY POWER sTATION---

ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/7/2011 BV1 ARERAS EXTRA17 XR015

.1RM-GW-109 CH9 RADIOACTIVITY OF RELEASED GASSES A

CPM Xe133=3.95 CP.M/uCI/cc 1.0

.1.2E6 N/A N/A S

1 N/A SEE UNIQUE SYSTEM. DESCRIPTION FIELD HIGH 1.76E5 CPM>BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N

N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to a General Emergency if the release continues for eight hours. RM-1GW-109 Channel 9 monitors for High Range noble gases at the discharge of the Gaseous Waste Disposal Blowers. The monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-419-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-86

L.

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 PCS RCS-LTD-RAD2 R0002A RX CLNT LTDN LO RNG 2CHS-RQ101A RAD LEVEL OF RCS LETDOWN LINE A

uCl/CC N/A 1.OE-3 1.0E4 N/A

  • N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N

N/A 2CHS-RQ101A monitors the gross activity of the reactor coolant (Cs-137) by drawing samples from the Reactor Coolant Letdown Line and delaying them to permit sufficient decay of the N-16 isotope before they pass by the detectors. This is an indication of fission products present in the reactor coolant. This radiation monitor provides the Low Range indication. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A detector monitors gross activity of the reactor coolant at Reactor Coolant Letdown Line.

2-26

. I BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 PCS RCS-LTD-RAD1 R0003A RX CLNT LTDN HI RNG 2CHS-RQ101B RAD LEVEL OF RCS LETDOWN LINE A

uCI/CC N/A 1.OE-1 1.0E6 N/A N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N

N/A 2CHS-RQ101B monitors the gross activity of the reactor coolant (Cs-137) by drawing samples from the Reactor Coolant Letdown Line and delaying them to permit sufficient decay of the N-1 6 isotope before they pass by the detectors. This is an indication of fission products present in the reactor coolant. This radiation monitor provides the High Range indication. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A detector monitors gross activity of the reactor coolant at Reactor Coolant Letdown Line.

2-27

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 PCS COND-AE-RAD2 R0010A.

AIR EJ DELAY BED 2GWS-RQ102

,COND AIR EJECTOR RADIOACTIVITY A

uCI/CC N/A 1.OE-7 1.0 N/A N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N

N/A 2GWS-RQ102 monitors the gaseous effluent from the Air Ejector Charcoal Bed for Xe-133. An alarm indicates a primary to secondary leak and a possible malfunction of the Charcoal Delay Beds. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A beta scintillation detector monitors Air Ejector Charcoal Bed gaseous effluent.

Ref: Op Manual Chapter 43; RM-443-17; TLD-43-062.

2-28

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Geperic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 PCS SG-BD-RAD-1A R0079A SG BLOWDOWN 2SSR-RQ100 STM GEN A/B/C BLOWDOWN RAD LEVEL A

uCI/CC N/A 1.OE-8 1.0E-1 N/A N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N

N/A 2SSR-RQI100 monitors the activity of the Steam Generator Blowdown for Cs-137. Samples are taken from a common header which acts as a manifold from the three Steam Generators. A High Alarm isolates the sample lines.

The sampling valve arrangement permits the operator to determine the source of the high activity. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator monitors the activity of the Steam Generator Blowdown effluent in a common header from all three Steam Generators.

2-29

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

  • 7/11/2011 BV2 PCS CTMNT-RAD1 R0086A IN-CNMT HI RNG AREA 2RMR-RQ206 RADIATION LEVEL IN CONTAINMENT A

R/HR N/A 1.OE-1 1.0E8 N/A N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N

N/A 2RMR-RQ206 monitors the radiation levels inside Containment and provides both local and Control Room alarms and indication. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. An ion chamber detects High Range area radiation levels inside Containment. Ref: Op Manual Chapter 43; TLD-43-017.

2-30

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 PCS CTMNT-RAD2 R0087A IN-CNMT HI RNG AREA 2RMR-RQ207 RADIATION LEVEL IN CONTAINMENT A

R/HR N/A 1.OE-1 1.0E8 N/A N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW I.

N N/A 2RMR-RQ207 monitors the radiation levels inside Containment and provides both local and Control Room alarms and indication. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. An ion chamber detects High Range area radiation levels inside Containment. Ref: Op Manual Chapter 43; TLD-43-018.

2-31

BEAVER VALLEY POWER STATION I ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 PCS MAIN-SL-1A R0088A MAIN STM ACTIVITY 2MSS-RQ101A STM GEN A STEAM LINE RAD LEVEL A

uCl/CC N/A 1.OE-3 1.0E4 N/A N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N

N/A 2MSS-RQ101A monitors the activity (Kr-88) following an accident in which the Power-Operated Dump Valves or Main Steam Safety Valves may be used as a discharge path to the environment. This monitor is activated by a Safety Injection Signal. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator detects activity in the Main Steam Line between SG A and the Main Steam Trip Valves upstream of the Safety Valve tie-in. Ref: Op Manual Chapter 43; TLD-43-071; RM-421-2.

2-32

BEAVER VALLEY POWER-STATION

. ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 PCS MAIN-SL-2B R0089A MAIN STM ACTIVITY 2MSS-RQ101B STM GEN B STEAM LINE RAD LEVEL A

uCI/CC N/A 1.OE-3 1.0E4 N/A N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N

N/A 2MSS-RQ101B monitors the activity (Kr-88) following an accident in which the Power-Operated Dump Valves or Main Steam Safety Valves may be used as a discharge path to the environment. This monitor is activated by a Safety Injection Signal. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator detects activity in the Main Steam Line between SG B and the Main Steam Trip Valves upstream of the Safety Valve tie-in. Ref: Op Manual Chapter 43; TLD-43-075; RM-421-2.

2-33

BEAVERVALLEY POWER _STATION_

ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 PCS MAIN-SL-3C R0090A MAIN STM ACTIVITY 2MSS-RQ101C STM GEN C STEAM LINE RAD LEVEL A

uCI/CC N/A 1.OE-3 1.0E4 N/A N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N

N/A 2MSS-RQ101C monitors the activity (Kr-88) following an accident in which the Power-Operated Dump Valves or Main Steam Safety Valves may be used as a discharge path to the environment. This monitor is activated by a Safety Injection Signal. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator detects activity in the Main Steam Line

.between SG C and the Main Steam Trip Valves upstream of the Safety Valve tie-in. Ref: Op Manual Chapter 43; TLD-43-076; RM-421-2 2-34

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Tum-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 PCS EFF-LIQ-RAD1 R0094A LIQ WST EFFLUENT 2SGC-RQ100 RADIOACTIVITY OF RELEASED LIQ A

uCI/CC N/A 1.OE-8 1.OE-1 N/A N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N

N/A 2SGC-RQ100 receives an auto-start signal and monitors the activity (Cs-137) in the Liquid Waste Process System when flow is detected. Upon detection of High radiation a valve is closed to prevent the release of this discharge.

Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator detects activity in the discharge from the Liquid Waste Process System. Ref: Op Manual Chapter 43; TLD-43-048 2-35

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/7/2011 BV2 ARERAS EXTRA17 XR015 1RM-GW-109 CH9 RADIOACTIVITY OF RELEASED GASSES A

CPM Xe133=3.95 CPM/uCl/cc 1.0 1.2E6 N/A N/A S

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 1.76E5 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N

N/A Point is 1 minute average. Site dose assessment varies CPM to uCI/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to a General Emergency if the release continues for eight hours. RM-1GW-109 Channel 9 monitors for High Range noble gases at the discharge of the Gaseous Waste Disposal Blowers. The monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-419-1; Calculation Package ERS-SFL-92-024; CR 04-05484 2-74

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Unfts/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/7/2011 BV2 ARERAS EFF-GAS-RAD1 XR041 2HVS-RQI101A RADIOACTIVITY OF RELEASED PARTIC A

uCi/cc N/A 3.24E-10 3.24E-4 0

N/A P

I N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 9.71E-5 uCi/cc >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N

N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. 2HVS-RQI101A monitors the airborne activity between the discharge of the Leak Collection Normal Exhaust Fans and the Ventilation Vent. A High activity signal will isolate the Purge System and indicate to the operator the need to divert flow through the Filter Banks.

Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Op Manual Chapter 43; TLD43-068; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484 2-75

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/7/2011 BV2 ARERAS EFF-GAS-RAD2 XR042 2HVS-RQI!01B RADIOACTIVITY OF RELEASED GASSES A

uCi/cc

  • N/A 3.7E-7 0.372 0

N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 1.81 E-4 uCi/cc >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N

N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. 2HVS-RQI101B monitors the airborne activity between the discharge of the Leak Collection Normal Exhaust Fans and the Ventilation Vent. A High activity signal will isolate the Purge System and indicate to the operator the need to divert flow through the Filter Banks.

Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Op Manual Chapter 43; TLD-43-068; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484.

2-76

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

7/7/2011 Reactor Unit:

BV2 Data Feeder:

ARERAS NRC ERDS Parameter:

EFF-GAS-RAD3 Point ID:

XR045 Plant Spec Point Desc.:

Generic/Cond Desc.:

2HVS-RQI109A RADIOACTIVITY OF RELEASED PARTIC Analog/Digital:

A Engr Units/Dig States:

uCi/cc Engr Units Conversion:

N/A Minimum Instr Range:

3.24E-10 Maximum Instr Range:

3.24E-4 Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

0 N/A S

1 N/A Sensor Location:

Alarm/Trp Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 2.59E-4 uCi/cc >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:

N Level Reference Leg:

N/A Unique System Desc.:

1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. 2HVS-RQI109A monitors the airborne activity between the discharge of the Leak Collection Filter Exhaust Fans and the Elevated Release Exhaust Line. This sample is composed of effluent from the Auxiliary and Fuel Buildings, after it has passed through Main Filter Banks in the SLCRS system before being discharged to atmosphere. Note:

The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to.the monitor conversion factor. Ref: Op Manual Chapter 43; TLD-43-068; RM-416-2; Calculation Package ERS-SFL-92-024; CR 04-05484.

2-77

1.

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

7/7/2011 Reactor Unit:

BV2 Data Feeder:

ARERAS NRC ERDS Parameter:

EFF-GAS-RAD4 Point ID:

XR046 Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

2HVS-RQI109 RADIOACTIVITY OF RELEASED GASSES A

uCi/cc N/A 2.5E-7 8.9E+4 0

N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

N/A N/A N/A DEPENDS ON FAILURE MODE N

N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. This is a multi-range monitor. Lowest onscale channel report. 2HVS-RQI109B, C and D monitors the gaseous activity between the discharge of the leak collection filter exhaust fans and the elevated release exhaust line. This sample is composed of effluent from the Auxiliary and Fuel Buildings, after it has passed through the Main Filter Banks in the SLCRS system before being discharged to atmosphere. Note The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref Calculation Package ERS-SFL-92-024 CR 04-05484 2-78

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 ARERAS EXTRA9 XR053 2MSS-RQI101A RADIOACTIVITY OF RELEASED GASSES A

uCi/cc N/A 2.5E-3 2.5E3 0

N/A

.P N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N

N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. Only read if release ongoing. Density corrected to atmospheric pressure. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.

2-79

BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 ARERAS EXTRA10 XR054 2MSS-RQI101B RADIOACTIVITY OF RELEASED GASES A

uCi/cc N/A 2.5E-3 2.5E3 0

N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N

N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. Only read if release ongoing. Density corrected to atmospheric pressure. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.

2-80

I BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:

Reactor Unit:

Data Feeder:

NRC ERDS Parameter:

Point ID:

Plant Spec Point Desc.:

Generic/Cond Desc.:

Analog/Digital:

Engr Units/Dig States:

Engr Units Conversion:

Minimum Instr Range:

Maximum Instr Range:

Zero Point

Reference:

Reference Point Notes:

PROC or SENS:

Number of Sensors:

How Processed:

Sensor Location:

Alarm/Trip Set Points:

NI Detector Power Supply Cut-Off Power Level:

NI Detector Power Supply Turn-ON Power Level:

Instrument Failure Mode:

Temperature Compensation for DP Transmitters:

Level Reference Leg:

Unique System Desc.:

7/11/2011 BV2 ARERAS EXTRA 11 XR055 2MSS-RQI101C RADIOACTIVITY OF RELEASED GASSES A

uCi/cc N/A 2.5E-3 2.5E3 0

N/A P

1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N

N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. Only read if release ongoing. Density corrected to atmospheric pressure. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.

2-81