L-11-052, Submittal of January NPDES Discharge Monitoring Report

From kanterella
Jump to navigation Jump to search

Submittal of January NPDES Discharge Monitoring Report
ML110540281
Person / Time
Site: Perry 
Issue date: 02/15/2011
From: Bezilla M
FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation, State of OH, Environmental Protection Agency
References
L-11-052
Download: ML110540281 (9)


Text

FENOC Perry Nuclear Power Plant g10 Center Road FirstEnergy Nuclear Operating Company Perry, Ohio 44081 Mark B. Bezilla 440-280-5382 Vice President Fax: 440-280-8029 February 15, 2011 L-1 1-052 Ohio Environmental Protection Agency Division of Water Pollution Control Enforcement Section, ES/DMR P.O. Box 1049 Columbus, Ohio 43216-1049

SUBJECT:

Perry Nuclear Power Plant, January NPDES Discharge Monitoring Report Enclosed are the Perry Nuclear Power Plant, NPDES monthly report forms for the month of January 2011. No violations occurred during this period.

If you have questions or require additional information, please contact Mr. Randall Killing at (440) 280-7370.

Sincerely,

/ )

Mark B. Bezilla "

Enclosures:

A Station Code 004 Report B Station Code 094 Report C Station Code 601 Report D Station Code 602 Report E Station Code 800 Report cc: NRC Region III NRC Resident Inspector NRR Project Manager NRC Document Control Desk (Docket No. 50-440)

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 SIUBMISSION ID:

FACILITY:

LOCATION:

COUNTY:

DISTRICT:

STATUS:

FirstEnergy Nuclear Gen Corp - Perry Plant PERMIT NUMBER:

10 Center Rd STATION CODE:

North Perry, OH 44081 MONITORING PERIOD:

Lake REPORTING LAB:

NEDO ANALYST:

NO DISCHARGE INDICATOR:

Draft 31B00016*ID 004 2011-01-01 To: 2011-01-31 CCB125 Randall Killing Zinc, Total Copper, Total Oxidants, Total Chlorine, Total PARAMETER Water Temperature Flow Rate pH Recoverable Recoverable Residual Residual PARAMETER CODE 00011 50050 00400 01094 01119 34044 50060 UNITS F

MGD S.U.

ug/I ug/1 m,/1 mgl FREQUENCY I/Day 1/Day 2/Week I/Month I/Month When Disch.

When Disch.

SAMPLING TYPE Continuous Continuous Grab Grab Grab Grab Grab 2011-01-01 52 43.6 9.83 4.59 AH AA 0.05 2011-01-02 50 43.1 AH AA 0.05 2011-01-03 47 41.3 AH AA 0.05 2011-01-04 47 43.1 8.17 AH AA 0.05 2011-01-05 45 40.5 AH AA 0.05 2011-01-06 45 42.0 AH AA 0.05 2011-01-07 47 46.7 8.14 AH AA 0.05 2011-01-08 44 44.8 AH AA 0.05 2011-01-09 45 43.6 AH AA 0.05 2011-01-10 44 54.9 AH AA 0.05 2011-01-11 43 52.0 8.16 AH AA 0.05 2011-01-12 43 51.6 AH AA 0.05 2011-01-13 44 51.7 AH AA 0.05 2011-01-14 43 51.9 8.24 AH AA 0.05 2011-01-15 44 50.3 AH AA 0.05 2011-01-16 44 54.8 AH AA 0.05 2011-01-17 43 52.8 AH AA 0.05 2011-01-18 45 46.8 8.12 AH AA 0.05 2011-01-19 45 48.6 AH AA 0.05 2011-01-20 44 49.1 AH AA 0.05 2011-01-21 44 46:3 8.14 AH AA 0.05 2011-01-22 42 43.4 AH AA 0.05 2011-01-23 45 44.1 AH AA 0.05 2011-01-24 44 45.2 AH

  • AA 0.05 2011-01-25 48 37.6 8.19 AH AA 0.05 2011-01-26 46 39.7 AH AA 0.05 2011-01-27 47 48.2 AH 0.05 2011-01-28 46 39.6 8.25 AH AA 0.05 2011-01-29 47 39.2 AH AA 0.05 2011-01-30 46 40.9 AH AA 0.05 2011-01-31 45 46.5 AH AA 0.05 Minimum 42.0 37.6 8.12 9.83 4.59 0.0 Maximum 52.0 54.9 8.25 9.83 4.59 0.05 Average 45.29032 45.93226 1

9.83 4.59 1

0.00161 Count 31 31 8

1 I

1 31 Name of Responsible Official I certify under the penalty of law that I have personally examined and am familiar Signature of Responsible Official or Authorized Submission or Authorized Representative with the information submitted herein and based on my inquiry of those individuals Representative Date/Time K

C P

,,z.-*

immediately responsible for obtaining the information, I believe the submitted SVPI j*i

'.i*.,information is true, accurate and complete. I am aware that there are significant

"-/j Venalties for submitting false information, including the possibility of fine and imprisonment.

12

'I Page 1

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 S:BMISSION ID:

FACILITY:

LOCATION:

COUNTY:

DISTRICT:

STATUS:

FirstEnergy Nuclear Gen Corp - Perry Plant PERMIT NUMBER:

10 Center Rd STATION CODE:

North Perry, OH 44081 MONITORING PERIOD:

Lake REPORTING LAB:

NEDO ANALYST:

NO DISCHARGE INDICATOR:

Draft 3IB00016*ID 004 2011-01-01 To: 20111-3 CCB125 Randall Killing Chlorination/Bromination PARAMETER Drto Duration PARAMETER CODE 78739 UNITS Minutes FREQUENCY When Disch.

SAMPLING TYPE Total 2011-01-01 100 2011-01-02 100 2011-01-03 100 2011-01-04 100 2011-01-05 100 2011-01-06 100 2011-01-07 100 2011-01-08 100 2011-01-09 100 2011-01-10 100 2011-0l-11 100 2011-01-12 100 2011-01-13 100 2011-01-14 100 2011-01-15 100 2011-01-16 100 2011-01-17 100 2011-01-18 100 2011-01-19 100 2011-01-20 102 2011-01-21 106 2011-01-22 100 2011-01-23 100 2011-01-24 100 2011-01-25 100 2011-01-26 100 2011-01-27 100 2011-01-28 100 2011-01-29 100 2011-01-30 102 2011-01-31 100 Minimum 100.0 Maximum 106.0 Average 100.32258 Count 31 Signature of Responsible OfcloAtrid Sb so Name of Responsible Official I certify under the penalty of law that I have personally examined and am familiar Signature of Responsible Official or Authorizet Submission or Authorized Representative with the information submitted herein and based on my inquiry of those individuals Representative Date/Time 0%rk ja 1

immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant "j

pd, at penalties for submitting false information, including the possibility of fine and imprisonment.

Page 2

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 SUBMISSION ID:

FACILITY:

LOCATION:

COUNTY:

DISTRICT:

STATUS:

FirstEnergy Nuclear Gen Corp - Perry Plant PERMIT NUMBER:

10 Center Rd STATION CODE:

North Perry, OH 44081 MONITORING PERIOD:

Lake REPORTING LAB:

NEDO ANALYST:

NO DISCHARGE INDICATOR:

Draft 3IB00016 *ID 094 2011-01-01 To: 2011-01-31 AL Flow Rate pH Zinc, Total Copper, Total Oxidants, Total Chlorine, Total PARAMETER Water Temperature Recoverable Recoverable Residual Residual PARAMETER CODE 00011 50050 00400 01094 01119 34044 50060 UNITS F

MGD S.U.

ug/l ugl mg/I mg/I FREQUENCY 1/Dav I/Day 2/Week I/Month 1/Month When Disch.

When Disch.

SAMPLING TYPE Continuous Continuous Grab Grab Grab Grab Grab 2011-01-01 2011-01-02 2011-01-03 2011-01-04 2011-01-05 2011-01-06 2011-01-07 2011-01-08 2011-01-09 2011-01-10 2011-01-11 2011-01-12 2011-01-13 2011-01-14 2011-01-15 2011-01-16 2011-01-17 2011-01-18 2011-01-19 2011-01-20 2011-01-21 2011-01-22 2011-01-23 2011-01-24 2011-01-25 2011-01-26 2011-01-27 2011-01-28 2011-01-29 2011-01-30 2011-01-31 Minimum

_In Maximum Average Count Name of Responsible Official I certify under the penalty of law that I have personally examined and am familiar Signature of Responsible Official or Authorized Submission or Authorized Representative vith the information submitted herein and based on my inquiry of those individuals Representative Date/Time e~ti*immediately responsible for obtaining the information, I believe the submitted j-1 information is true, accurate and complete. I am aware that there are significant J

t' penalties for submitting false information, including the possibility of fine and imprisonment.

Page 3

i SUBMISSION ID:

FACILITY:

LOCATION:

COUNTY:

DISTRICT:

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 STATUS:

Draft FirstEnergy Nuclear Gen Corp - Perry Plant PERMIT NUMBER:

31BOOO16*ID 10 Center Rd STATION CODE:

094 North Perry, OH 44081 MONITORING PERIOD:

2011-01-01 To: 2011-01-31 Lake REPORTING LAB:

NEDO ANALYST:

NO DISCHARGE INDICATOR:

AL Chlorination/Bromination PARAMETER Drto Duration PARAMETER CODE 78739 UNITS Minutes FREQUENCY When Disch.

SAMPLING TYPE Total 2011-01-01 2011-01-02 2011-01-03 2011-01-04 2011-01-05 2011-01-06 2011-01-07 2011-01-08 2011-01-09 2011-01-10 2011-01-11 2011-01-12 2011-01-13 2011-01-14 2011-01-15 2011-01-16 2011-01-17 2011-01-18 2011-01-19 2011-01-20 2011-01-21 2011-01-22 2011-01-23 2011-01-24 2011-01-25 2011-01-26 2011-01-27 2011-01-28 2011-01-29 2011-01-30 2011-01-31 Minimum Maximum Average I

Count Name of Responsible Official I certify under the penalty oflaw that I have personally examined and am familiar Signature of Responsible Official or Authorized Submission or Authorized Representative with the information submitted herein and based on my inquiry of those individuals Representative Date/Time immediately responsible for obtaining the information, I believe the submitted J

information is true, accurate and complete. I am aware that there are significant

..J-penalties for submitting false information, including the possibility of fine and U, C r-imprisonment.

l r

l d~-

/

Page 4

/

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 SUBMISSION ID:

FACILITY:

LOCATION:

COUNTY:

DISTRICT:

STATUS:

FirstEnergy Nuclear Gen Corp - Perry Plant PERMIT NUMBER:

10 Center Rd STATION CODE:

North Perry, OH 44081 MONITORING PERIOD:

Lake REPORTING LAB:

NEDO ANALYST:

NO DISCHARGE INDICATOR:

Draft 3IB00016 *ID 601 2011-01-01 To: 2011-01-31 AL PARAMETER Flow Rate pH Total Suspended Oil and Grease, Solids Total PARAMETER CODE 50050 00400 00530 00550 UNITS MGD S.U.

mg/I m___/I FREQUENCY Continuous 1 / 2 Weeks 1 / 2 Weeks 1 / 2 Weeks SAMPLING TYPE 24hr Total Grab Grab Grab 2011-01-01 2011-01-02 2011-01-03 2011-01-04 2011-01-05 2011-01-06 2011-01-07 2011-01-08 2011-01-09 2011-01-10 2011-01-11 2011-01-12 2011-01-13 2011-01-14 2011-01-15 2011-01-16 2011-01-17 2011-01-18 2011-01-19 2011-01-20 2011-01-21 2011-01-22 2011-01-23 2011-01-24 2011-01-25 2011-01-26 2011-01-27 2011-01-28 2011-01-29 2011-01-30 2011-01-31 Minimum Maximum Average Count Name of Responsible Official I certify under the penalty of law that I have personally examined and am familiar Signature of Responsible Official or Authorized Submission or Authorized Representative with the information submitted herein and based on my inquiry of those individuals Representative Date/Time 7Yp 4

~'* :'I lq immediately responsible for obtaining the information, I believe the submitted j.C information is true, accurate and complete. I am aware that there are significan*t penalties for submining false information, including the possibility of fine andm...i

/1 5imprisonment.

Page 5 ii

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 SUBMISSION ID:

FACILITY:

LOCATION:

COUNTY:

DISTRICT:

STATUS:

FirstEnergy Nuclear Gen Corp - Perry Plant PERMIT NUM BER:

10 Center Rd STATION CODE:

North Perry, OH 44081 MONITORING PERIOD:

Lake REPORTING LAB:

NEDO ANALYST:

NO DISCHARGE INDICATOR:

Draft 3IB0001 6 *ID 602 2011-01-01 To: 2011-01-31 AL PARAMETER Flow Rate pH Total Suspended Oil and Grease, Iron, Total Copper, Total Solids Total Recoverable Recoverable PARAMETER CODE 50050 00400 00530 00550 00980 01119 UNITS MGD S.U.

mm*/

umgl________/I FREQUENCY Continuous I / 2 Weeks 1 / 2 Weeks 1 / 2 Weeks 1 / 2 Weeks I / 2 Weeks SAMPLING TYPE 24hr Total Grab 24hr Composite Grab 24hr Composite 24hr Composite 2011-01-01 2011-01-02 2011-01-03 2011-01-04 2011-01-05 2011-01-06 2011-01-07 2011-01-08 2011-01-09 2011-01-10 2011I01 -11 2011-01-12 2011-01-13 2011-01-14 2011-01-15 2011-01-16 2011-01-17 2011-01-18 2011-01-19 2011-01-20 2011-01-21 2011-01-22 2011-01-23 2011-01-24 2011-01-25 2011-01-26 2011-01-27 2011-01-28 2011-01-29 2011-01-30 2011-01-31 Minimum Maximum Average Count Name of Responsible Official I certify under the penalty of law that I have personally examined and am familiar Signature of Responsible Official or Authorized Submission or Authorized Representative with the information submitted herein and based on my inquiry of those individuals Representative Date/Time

~vY f.

LI0 k immediately responsible for obtaining the information, I believe the submitted 0

information is true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and gimprisonment.

L Page 6

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 SUBMISSION ID:

FACILITY:

LOCATION:

COUNTY:

DISTRICT:

STATUS:

FirstEnergy Nuclear Gen Corp - Perry Plant PERMIT NUMBER:

10 Center Rd STATION CODE:

North Perry, OH 44081 MONITORING PERIOD:

Lake REPORTING LAB:

NEDO ANALYST:

NO DISCHARGE INDICATOR:

Draft 3IB00016*ID 800 2011-01-01 To: 2011-01-31 CCB 125 Randall Killing PARAMETER Water Temperature Zinc, Total Copper, Total PARAMETER

_terTeperature Recoverable Recoverable PARAMETER CODE 00011 01094 01119 UNITS F

ug__l u_/I FREQUENCY 1/Day I/Month 1/Month SAMPLING TYPE Continuous Grab Grab 2011-01-01 35 4.89 AA 2.5 2011-01-02 36 2011-01-03 36 2011-01-04 35 2011-01-05 33 2011-01-06 34 2011-01-07 33 2011-01-08 33 2011-01-09 33 2011-01-10 32 2011-01-11 33 2011-01-12 32 2011-01-13 32 2011-01-14 32 2011-01-15 32 2011-01-16 32 2011-01-17 32 2011-01-18 32 2011-01-19 32 2011-01-20 33 2011-01-21 32 2011-01-22 33 2011-01-23 33 2011-01-24 33 2011-01-25 34 2011-01-26 34 2011-01-27 34 2011-01-28 33 2011-01-29 34 2011-01-30 34 2011-01-31 34 Minimum 32.0 4.89 0.0 Maximum 36.0 4.89 0.0 Average 33.22581 4.89 0

Count 31 1

I Name of Responsible Official I certify under the penalty of law that I have personally examined and am familiar Signature of Responsible Official or Authorized Submission or Authorized Representative with the information submitted herein and based on my inquiry of those individuals Representative Date/Time immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant p

,penalties for submitting false information, including the possibility of fine and P ~J

~ect.K imprisonment.

'1 Page 7

/

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FirstEnergy Nuclear Gen Corp - Perry Plant PERMIT NUMBER:

31B00016*ID 10 Center Rd MONITORING PERIOD:

2011-01-01 To: 2011-01-31 North Perry, OH 44081 FACILITY:

LOCATION:

PARAMETER COMMENTS:

Station Code Parameter Name Parameter Code Date Unit Comment 004 Oxidants, Total Residual 34044 2011-01-01 mg/l No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-02 mg/l No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-03 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-04 mg/l No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-05 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-06 mg/I No bromination event this date 004 Oxidants, TotalResidual 34044 2011-01-07 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-08 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-09 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-10 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-11 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-12 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-13 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-14 mg/l No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-15 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-16 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-17 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-18 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-19 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-20 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-21 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-22 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-23 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-24 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-25 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-26 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-27 mg/l No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-28 mg/l No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-29 mg/l No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-30 mg/I No bromination event this date 004 Oxidants, Total Residual 34044 2011-01-31 mg/I No bromination event this date