JAFP-86-0479, Advises That Min Flow Logic Circuit for RHR Sys Not Susceptible to Single Failure,Per IE Bulletin 86-001,due to Removal of LPCI Loop Select Logic & Closure & Electrical Disabling of RHR cross-tie Valve
| ML20211E604 | |
| Person / Time | |
|---|---|
| Site: | FitzPatrick |
| Issue date: | 06/04/1986 |
| From: | Radford Converse POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK |
| To: | Murley T NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| References | |
| IEB-86-001, IEB-86-1, JAFP-86-0479, JAFP-86-479, NUDOCS 8606160179 | |
| Download: ML20211E604 (1) | |
Text
F J:mes A. Fit:P: trick Nuclerr Pow:r Plant P O Bo = 41 Lycomeng. New York 13093 315 342 3840 Radford J. Converse
- > NewYorkPower 4# Authoriq 37333 June 4, 1986 JAFP-86-0479 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention: Thomas Murley Regional Administrator
SUBJECT:
NRC IE Bulletin 86-01 Minimum Flow Logic Problems That Could Disable RHR Pumps
Dear Mr. Murley:
As requested by the subject bulletta, a review of the minimum flow logic installed on the FitzPatrick Resilus1 Heat Removal (RHR) System has been conducted. Due to the removal of the Low Pressure Coolant Injection (LPCI) Loop Select Logic and the closure and electrical disabling of the RHR cross-tie valve (10-MOV-20), each injection loop of the RHR System uses individual loop flow and pump breaker indication to operate the minimum flow valve for that individual loop. Therefore, a single failure of a flow sensing instrument would only affect the RHR loop in which the instrument is installed.
Based on this, the James A. FitzPatrick Nuclear Power Plant'a Minimum Flow Logic Circui
,f r _ e RHR System is not susceptible to single failure vulnerability,
/
i RADF0 J. CONVERSE RESIDENT MANAGER RJC:RAL:lar Subscribed & Swo n to before me this 4th da of June, 986.
T!!OM A9 G. COlTEY, Jis.
).
Notary 1*ublic - 8 tate of New York sa cec:a
/
QT!Ilfdl tu Oswego Cennt?
"'""""""*"'"E-jlic No CC:
U.S. Nuclear Regulatory Commission, Document Control Desk, Washington, DC 20555 RMS for Headquarters Distribution /WPO, W. Fernandez/JAF, R. L. Patch /JAF, D. J. Lindsey/JAF, NRC Resident Inspector /JAF, NRCB-86-01 File, Document Control Center ndif J
86hk k1N h6 604 b
PDR ADOCK 05000333 I) 1 G