JAFP-83-1225, Monthly Operating Rept for Nov 1983
| ML20082S349 | |
| Person / Time | |
|---|---|
| Site: | FitzPatrick |
| Issue date: | 11/30/1983 |
| From: | Jackie Cook, Corbin McNeil POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK |
| To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE) |
| References | |
| JAFP-83-1225, NUDOCS 8312140114 | |
| Download: ML20082S349 (7) | |
Text
?
.b OPERATING DA"I A REPORT DOCKET NO. 50-333 DATE _ December 1983 COMPLETED BY J. Cook TELEPHONE. (315)342-3840 OPERATING STATUS FITZPATRICK Notes
.1. Unit Name:
- 2. Reporting Period:
831101 - 831130
- 3. Licensed Thermal Power (MWt):
2436 883
- 4. Nameplate Rating (Gross MWe):
821
- 5. Design Electrical Rating (Net MWe):
- 6. Maximum Dependable Capacity (Gross MWe): 830
- 7. Maximum Dependable Capacity (Net MWe): 810
- 8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons:
N/A
- 9. Power Level To Which Restricted,If Any (Net MWe):
NONE
- 10. Reasons For Restrictions,if Any:
N/A 4
This Month Yr..to.Date Cumulatise 720 8016 73153 I1. Hours In Reporting Period
- 12. Number Of Hours Reactor Was Critical 720 5529.1 51784.8 0
0 0
- 13. Reactor' Reserve Shutdown Hourr 720 5440.4 50455.6
- 14. Hours Generator On-Line
- 15. Unit Reserve Shutdown Hours 0
0 0
l
- 16. Gross Thermal Energy Generated (MWH) 1720344 12433152 105957010 l-
- 17. Gross Electrical Energy Generated (MWH) 578630 4184440 36619220 l
- 18. Net Electrical EnerEy Generated (MWH) 560470 4053865 34918250
- 19. Unit Service Factor 100%
67.86%
68.97%
100%
67.86%
68.97%
- 20. Unit Availability Factor
- 21. Unit Capacity Factor (Using MDC Net) 96.1%
62.43%
62.53%
- 22. Unit Capacity Factor (Using DER Net) 94.81%
61.59%
58.14%
0%
5.8%
14.75%
- 23. Unit forced Outage Rate
- 24. Shutdowns Scheduled Over Next 6 Months (Type. Date,and Duration of Each):
Maintenance outage to conanence around January 20.FS4.
Lasting approximately ten days.
- 25. If Shut Down At End Of Report Period. Estimated Date of Startup:
i
- 26. Units In Test Status (Prior to Commercial Operation):
Forecast Achieved l
l INITIAL CRITICALITY I
INITIAL ELECTRICITY COMMERCIAL OPERATION l
8312140114 831209 PDR ADOCK 05000333 R
pay
7 AVERAGE DAll.Y UNIT POWER LEVEL j..
[
i DOCKET NO. 333 I
UNIT FITZPATRICK i
DATE DECEMBER 1983 i
COMPLETED.BY
.T. cong TELEPHONE (315)342-3840.
I a
l MONTH NOVEMBER, 1983 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWEP, LEVEL
{
(MWe-Net)
(MWe-Net)
[
793 794 g
g7 792 2
33 789 I
3 19 792 793 4
0 576 s
794 r
633 794 6
22 l
7 742 3
795 i
3 789 24 793 790 793 3
I 10 792 26 792 790 794 11 27 4;
792 794 12 j
13 794 794 29 794 793 2
14 30 1
794 15 31 16 795
SUMMARY
The Fitzpatrick Plant operated at near full thermal power for this entire reporting period.
b 4
-w
q I
I
~
zo 4
.m.m.
z g
M m.
e.v:
Ac. e.c.
E. c.
nc-c u
K IJ l
0 ' m 9 9 :' > f Type co>Ozzrmu c
a u.c -
- - X o. a n n aa
-- =
O E 0 E. E 3 c ".
5' l
5~c"~E3 Duralism mc ua f f 2 qq, g 3 (llours)
. 2 0. m m
es u
u
- ,.: n
- 2. es
,o. =
,=
- r..=
a,c
=
M e.
Reason,
a a
{ Cg-
~~
m
- 3
=
3-Method of c
3 Shutting 2
n Down ReactorI q
m r
m
=
p
=
c m
=
~4 b
C
~
M r
5 ym[
n O
ca m H
T Eg g
2 O2 2
o m
-z
-o o
O t y y -- I System O>Er2 Codc4 a"
-cu uw w-oo-eng z
2.c e e c, d 2. 2. -
m m ". m C
~*
C 5 EO Cornpor:ent m=
co
- 2. n 5 Code'c V
O 5
2w a
.n s
n.
O 3
n g
m ommmm 3
E Mm C
on
=x
-*=
w n
F 2
a>n r
m 6-
~ I 4 ~ '- E C>
Q --(
-4h z!aE f=e'n
=m
=
C >e ZH ZWHD2 43E0 O
c.
=
y
=2h-C -:
g,r-
- - R -
m < m m.o u
5
~~=-
=
2 f~ ~
m 2
5 WL. c
'1 u m
w m s o 3 *--
e-O H i
O
-Qg-
=
=
wn m s w u
7 m = "- E vo
- s e w e.
==
wo tz > w
- W m H 4
N
- c
- c Z
I M
e-
'u
.. O O
00
@ X d'
00 h.
o W
k.
NEW YORK POWER AUTHORITY JAMES.A. FITZPATRICK NUCLEAR POWER PLANT NARRITIVE
SUMMARY
OF OPERATING EXPERIENCE NGVEMBER 1983 The unit operated at near full thermal power for this entire reporting period.
At the end of the reporting period the unit is operating at approximately 793 MWc.
l u
l
POWER AUTHORITY OF THE STATE OF NEW YORK JAMES A. FITZPATRidK NOCL. EAR POWER PLANT
(.
SAFETY RELATED ELECTRICAL a MECHANICAL MAINTENANCE
SUMMARY
NOVEMBER 1983 RE N #
DATE SYSTEM HOW DETECTED CAUSE OF MALFUNCTION ACTION TAKEN TO PRECLUDE RECURRENCE T E COMPONENT #
HOURS 11/04 00 22724 Letter Suspected faulty Replaced arms 2
NAMCO from actuator arms j
switches supplier j
11/03 10 28328 Visual Vibration caused Replaced nipple 10 HP1-401 3/4" nipple to crack
.2
& 402A i
11/02 23 28328 Visual Worn Packing Repacked 6
LS-90 11/04 23 29303 Visual Worn Packing Adjusted packing 4
MOV-14 I
11/15 13 29324 Visual Worn Packing Repacked 10 MOV-131 1?/08 27 25306 OPS Leaking diaphragm Rebuilt valve 84 i-PCV1228 and gaskets 12/03 10 18453 S.T.
Worn shaft and Replaced bearings 116 P-1C bearings 11/07 23 22979 OPS Overspeed_ trip Cleaned filters, replaced 108 TU-2 failed to reset dirt spindle & ball assembly
NEWYORK POWER AUTHORITY-JAMES A.FITZPATRICK NUCLEAR POWER PLANT MAINTENANCE
SUMMARY
I & C NOVEMBER, 1983 WORK REQUEST NO.
HOW CAUSE OF RESULTS OF ACTION TAKEN REPAIR DATE SYSTEM COMPONENT NO.
DETECTED MALFUNCTION MALFUNCTION TO PRECLUDE TIME RECURRENCE HOURS 2
10/31/83 76 027613 OPS Bad light Amber light failed Changed light bulb 8
CO2-PNL-2 to light 11/8/83 13 029312 OPS Out of adjustment Max centroller Adjusted controller
- 10 EGM output i
11/10/83 23 028522 JIC Sticky switches Ensure proper Cleaned switches &
8 i
LS-74A/B operation of SW ran ISP-75 l
1 11/10/83 07 029344 OPS Wear and tear Mode switch loose Tightened Allen 1
APRM-F screws on HNDL l
11/15/83 17 029297 OPS Check source Check source stuck Mechanically unbounc 4
i RIS-452B binding up in out POS.
CK source i
11/15/83 17 029441 JIC Broken connector Bad LPRM cable Replaced connector 4
RM-150A connector 11/16/83 17 027671 OPS Loose gear, worn REC doesn't Welded and bored 5.0 4
f RR-154 hub shaft advance chart out shaft i
11/18/83 07 029397 OPS Bad DC amp (card Unit failed Replaced amp; 26 APRM-E Z-32)-old age downscale adjusted 11/22/83 16 029431 Penetration not Penetration Filled X-104D W/N2 3
X-104D OPS pressurized pressure 10 PSIG to 15 PSIG l
r Jamea A. FitrPrtrick Nuclear Power Pl!.nt RO. Box 41 Lycommg, New York 13093 315 342.3840
- D NewYorkPower 4# Authority December 9, 1983 JAFP-83-1225 a
Director, Office of Inspectio'n and Enforcement U.S. Regulatory Commission
-Washington, D.C.
20555 ATTENTION:
Document Control Desk
REFERENCE:
Docket No. 50-333
Dear Sir:
The Operating Status Report for the month of November, 1983 is enclosed.
The refueling information remains the same as previously submitted.'
If there are any questions concerning this report, contact John Cook at (315)342-3840, Ext. 439.
Very truly yours, Corbin A. McNeill, Jr.
Enclosures CC:
Internal Distribution ZGAY
'll
.-