IR 07200038/2021001

From kanterella
Jump to navigation Jump to search
Construction of an Independent Spent Fuel Storage Installation Report 07200038/2021001
ML21120A063
Person / Time
Site: McGuire, Mcguire  
Issue date: 04/30/2021
From: Binoy Desai
NRC/RGN-II/DRS/EB3
To: Teresa Ray
Duke Energy Carolinas
References
EPID I-2021-001-0150 IR 2021001
Download: ML21120A063 (6)


Text

April 30, 2021

SUBJECT:

MCGUIRE NUCLEAR STATION - CONSTRUCTION OF AN INDEPENDENT SPENT FUEL STORAGE INSTALLATION REPORT 07200038/2021001

Dear Mr. Ray:

On April 7, 2021, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at McGuire Nuclear Station and discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely,

/RA/

Binoy B. Desai, Chief Engineering Branch 3 Division of Reactor Safety

Docket No. 07200038

Enclosure:

As stated

Inspection Report

Docket Number:

07200038

License Number:

NPF-9 and NPF-17

Report Number:

07200038/2021001

Enterprise Identifier: I-2021-001-0150

Licensee:

Duke Energy Carolinas, LLC

Facility:

McGuire Nuclear Station

Location:

Huntersville, North Carolina

Inspection Dates:

February 15, 2021 to April 7, 2021

Inspectors:

P. Cooper, Senior Reactor Inspector

Approved By:

Binoy B. Desai, Chief

Engineering Branch 3

Division of Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees

performance by conducting inspections of activities related to McGuire Nuclear Stations (MNS)

pre-operational activities of dry cask storage of spent fuel from February 15, 2021 to

April 7, 2021. The NRCs program for overseeing the safe operation of dry storage of spent fuel

at an Independent Spent Fuel Storage Installations (ISFSI) is described in Inspection Manual

Chapter 2690, Inspection Program for Dry Storage of Spent Reactor Fuel at Independent Spent

Fuel Storage Installations and for 10 CFR Part 71 Transportation Packagings.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in

effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with

their attached revision histories are located on the public website at http://www.nrc.gov/reading-

rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared

complete when the IP requirements most appropriate to the inspection activity were met

consistent with Inspection Manual Chapter (IMC) 2690, Inspection Program for Storage of

Spent Reactor Fuel and Reactor-Related Greater-than-Class C Waste at Independent Spent

Fuel Storage Installations (ISFSI) and for 10 CFR Part 71 Transportation Packagings." The

inspectors reviewed selected procedures and records, observed activities, and interviewed

personnel to assess licensee performance and compliance with Commission rules and

regulations, license conditions, site procedures, and standards.

60853 - ON-SITE FABRICATION OF COMPONENTS AND CONSTRUCTION ON AN ISFSI

On-Site Fabrication of Components and Construction on an ISFSI (1 Sample)

(1)

On February 15 - April 7, 2021 the inspector conducted a review of licensee and

vendor activities in preparation for the construction of a concrete storage pad,

identified as Pad 9, to store 6 MAGNASTOR systems. The inspectors verified that

activities related to the ISFSI have been properly incorporated into the existing

licensee programs by reviewing the following activities:

a. ISFSI pad design

The inspector verified that the licensee completed evaluations which establish that

the ISFSI storage pads and areas have been designed to adequately support the

static and dynamic loads of the stored dry storage systems (DSS), considering

potential amplification of earthquakes through soil-structure interaction, and soil

liquefaction potential or other soil instability due to vibratory ground motion by

reviewing the following calculations;

  • MCC-1140.00-00-0010, "Concrete Slab (foundation) Analysis for Dry Cask

Storage"

MCC-1140.00-00-0091, "Soil-Structure Interaction Analysis for ISFSI Pad 9"

b. ISFSI pad construction

The inspector verified the ISFSI storage pad was constructed in accordance with the

DSS Certificate of Compliance (CoC) and reviewed licensee controls that ensured no

adverse impact on site operations or technical specifications (TS) by performing the

following activities;

  • The inspector walked down the construction area of the ISFSI pad to verify the

formwork and rebar placement complied to licensee-approved drawings,

specifications,

The inspectors observed the placement of the ISFSI slab, and observed tests

for concrete slump, air content, temperature measurements, and the

collection/preparation of cylinder samples for compression tests, to verify that

the work was implemented in accordance with the approved specifications

and procedures,

The inspector verified that the pad was being finished according to

approved specifications and code requirements,

Following completion of the 7-day and 28-day compression tests by the

independent laboratory, the inspector reviewed the results to verify that

the acceptance criteria were met.

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On April 7, 2021, the inspectors presented the results to Tom Ray, Site Vice President and

other members of the licensee staff.