IR 05000507/2006003

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 850507-0603
ML18142A558
Person / Time
Site: Surry, 05000507  
Issue date: 06/25/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML18142A557 List:
References
50-280-85-19, 50-281-85-19, NUDOCS 8507110797
Download: ML18142A558 (1)


Text

, I I

I

~

I

,_

I I

ENCLOSURE 1 NOTICE OF VIOLATION Virginia Electric and Power Company Surry Units 1 and 2 Docket No and 50-281 License No DPR-32 and DPR-37 The following violation was identified during an inspection conducted on May 7 - June 3, _198 The Severity Level was assigned in accordance with the NRC Enforcement Policy (10 CFR Part 2, Appendix C).

.

Appendix B to 10 CFR 50, Criterion V requires that activities affecting quality shall be prescribed by documented instructions, procedures or drawings of a type appropriate to the circumstances and shall be accomplished in accordance with these instructions, procedures or drawing Contrary to the above, appropriate procedures were not prescribed nor provided for the installation of the environmentally qualified (EQ) Conax electrical conductor (connector) seal assembly on to EQ, safety-related electrical components inside the Units 1 and 2 containment For example, Design Change procedure DC-81-103 and Attachments, for replacing the Class IE transmitters and seal assemblies, did not provide appropriate instructions for centering the midlock ferrule on the feedthrough assembly and did not specify thread sealing materials or proper bracing for the installation In addition, certain installations were not accomplished in accordance with the DC-81-103 procedures and instructions. Seal assemblies were found over and under torqued and installed backwards, and two unqualified PL type seal assemblies were found installed inside containmen As a result of the above, some 10 EQ, safety-related electrical components inside the Units 1 and 2 containments were determined to be unqualified, and at least 36 of the remaining 200 EQ components inside the containments may not have provided adequate sealing during and following design basis event This is a Severity Level IV violation (Supplement II).

Pursuant to 10 CFR 2.201, you are required to submit to this office within 30 days of the date of this Notice a written statement or explanation in reply including:

(1) admission or denial of the alleged violations; (2) the reasons for the violations if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieve Security or safeguards i nformat-i.,on.... shoul d be submitted as an enclosure to facilitate withholding it from public disclosure as required by 10 CFR 2.790(d)

or 10 CFR 73. 2 Date:

JUN 25 19S5

,r r-- 8507110797 850625

PDR' ADOCK 05000280 G

PDR*

' j