IR 05000422/2005008

From kanterella
Jump to navigation Jump to search
Notice of Deviation from Insp on 850422-0508.Thermal Overloads on safety-related Motor Operated Valves Could Be Unbypassed by Switches on Panel 0C697 & Condition Not Indicated in Control Room
ML17156A387
Person / Time
Site: Susquehanna, 05000422  
Issue date: 07/16/1985
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML17156A384 List:
References
50-387-85-16, 50-388-85-15, EA-85-073, EA-85-73, NUDOCS 8507220353
Download: ML17156A387 (2)


Text

APPENDIX B NOTICE OF DEVIATION Pennsylvania Power

& Light Company Susquehanna Steam Electric Station Units 1 and

Docket Nos.

50-387

, 50-388 License Nos.

NPF-14

'PF-22 EA 85-73 During an NRC inspection conducted on April 22 May 8, 1985, a deviation from the Final Safety Analysis Report (FSAR) was identified.

In accordance with the

"General Statement of Policy and Procedure for NRC Enforcement Actions,"

CFR Part 2 Appendix C (1985), the deviation is set forth below:

The Final Safety Analysis Report (FSAR),

and Regulatory Guide (RG) 1. 106, Revision 1 specifies that thermal overloads in safety related motor,'perated valves be continuously bypassed.

Section C. 1 of this RG specifies that the non-bypassing of these thermal overloads be continuously indicated in the control room.

Contrary to the above, thermal overloads on safety-related motor operated valves can be unbypassed by switches on Panel OC697 and this condition is not indicated in the control room.

This is a deviation.

Pennsylvania Power 5 Light Company is hereby requested to submit to this,',office within>30 days of the date of the letter transmitting this Notice, a written statement or explanation in reply, including:

(1) the corrective steps which have been taken and the results achieved, (2) the corrective steps which, will be taken to avoid further deviations, and (3) the date when corrective action will be completed.

8507220353 8507ib PDR ADOCK 05000387

PDR OFFICIAL RECORD COPY CP PKG SUSQUEHANNA REV 2 - 0006.0.0 07/12/85

~e

0