IR 05000367/1979003

From kanterella
Jump to navigation Jump to search
IE Insp Rept 50-367/79-03 on 790709.No Noncompliance Noted. Major Areas Inspected:Site Tour & ACRS Meeting Re Pile Foundation Design
ML19249C910
Person / Time
Site: Bailly
Issue date: 07/18/1979
From: Knop R, Phillips H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19249C905 List:
References
50-367-79-03, 50-367-79-3, NUDOCS 7909190277
Download: ML19249C910 (3)


Text

{{#Wiki_filter:. U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT

REGION III

Report No. 50-367/79-03 Docket No. 50-367 License No. CPPR-104 Licensee: Northern Indiana Public Service Company 5256 Hohman Avenue Hammond, IN 46325 Facility Name: Bailly Generating Station Nuclear 1 Inspection At: Bailly Site, Porter, Indiaaa Holiday Inn, Portage, Indiana Inspection Conducted: Jul-9, 1979 . . {{ -r% J-7 7- 0 9

Inspector: H. S.

I 1ps < L '{/ n Approved By: R. CT op, dhie( h /f-7f p'W Projects Section 1 Inspection Summary Inspection on July 9, 1979 (Report No. 50-367/79-03) Areas Inspected: Site tour; ACRS meeting relative to pile foundation desi n.

The inspection involved a total of 7 on site inspector-hours by

one h3C inspector.

Results: No items of noncompliance or deviations were identified.

. t60 79091902

, - DETAILS . Persons Contacted on Site R. J. Bohn, Manager Nuclear Staff C. A. Carlisle, Manager of Quality Assurance C. F. Braun and Company D. Maxwell, C. F. Braun and Company Site QC Supervisor E. Barnett, C. F. Braun and Company Quality Control Engineer 1.

Plant Tour NIPSCo Nuclear Staff Manager conducted a tour at the excavation where pile driving had been accomplished under nonsafety related structures. Test pile which were driven in areas where safety related structures were also observed.

2.

The inspector attended the ACRS subcommittee meeting to render assistance to NRC Headquarters personnel relative to the Region III Inspection and Enforcement (IE) program. No assistance was required because no question was raised regarding the IE Program.

The ACRS subcommittee meeting agenda was as follows: TENTATIVE DETAILED SCHEDULE ACRS BAILLY SUMCOMMITTEE MEETING PORTAGE HOLIDAY INN 6200 Melton Road Portage, Indiana 46368 July 9, 1979 Times Are Approximate I.

EXECUTIVE SESSION (OPEN) 2:00 P.M.

Opening Statement - Dr. Stephen Lawroski, Bailly Subcommittee Chairman 2:05 Brief report of ACRS Consultants - Dr. F. E. Richart U. of Michigan Dr. R. E. Scott, Ca1. Inst.

, 2:20 II.

INTRODUCTION BY NRC STAFF - Mr. M. David Lynch NRC Staff Licensing Project Mgr.

-2- - , ' L' . , . t '

. - 2:30 III. KEETING WITH APPLICANT - Northern Indiana Public Service Company - Introduction 1.

History of Project, Evolution of Pile Design, Mr. Russell Bohn, NIPSCO 2.

Soil Details, Tests Performed - Mr. Michael Keiffer, Dames & Moore 3:40 IV.

MEETING WITH NRC STAFF - Mr. M. D. Lynch, LPM Mr. Lyman Heller - GeoSciences Br.

Mr. Franz Schauer - Ch, Structures & Engrg. Br.

Mr. John Ma - Structures & Engrg. Br.

4:00 V.

STATEMENTS BY PUBLIC (IF REQUESTED) 4:30 VI.

EXECUTIVE SESSION (OPEN) 4:45 VII. CLOSING REMARKS Presentations Recommended for full Committee Review 6:00 P.M.

July 12 5:00 P.M.

ADJ0 URN The subcommittee focused attention on the foundation design, that is, short versus long pile design. The purpose of the meeting was to gather facts to be reported to the full ACRS committee on July 12, 1979.

The licensee's presentation included technical data to show that the proposed short pile design would satisfy original PSAR design criteria / requirements.

The NRC staff summary stated that densific. ion of piling and driving criteria required additional attention by NRR/NIPSCo. Piles which break through and which would not meet the required blow counts should be adequately covered.

Bracing in 3reas to be excavated was also considered an open item. Other matters to be followed up by NRR were factors of safety, corrosion, up lift and licensee analysis of the pinned or fixed effect.

-3- . , iU9 I t iOJ }}