Text
.
l
'
.
U.S. NUCLEAR REGULATORY CO E SSION OFFICE OF INSPECTION AND ENFORCEMENT
REGION III
Report No. 50-367/78-05 Docket No. 50-367 License No. CPPR-104 Licensee: Northern Indiana Public Service Corporation 5256 Hohman Avenue Hammond, IN 46325 Facility Name:
Baily Generating Station Nuclear 1 Inspection At:
Bailly Site, Porter, IN b
Inspection Conducted: August 18, 1978 E ~ y h !d %
[ 7b Inspectors:
E. Y. Gallagh'er
.
J. H. Neisler hd 9-T-?/
Accompanied By:
D. k'.
Hayes 0 (J. - w< >+ r,+ -
i
,
p//4 j.,9,.
~
'X:
.
..
Approved By:
R. L. Spes'sard, Chief Engineering Support Section 1 Inspection Su= mary Inspection on August 18, 1078 (Recort No. 50-367/78-05)
Areas Inspected:
Foundation piles installation, procedures and quality records; qualifications and training of pile driving inspectors. The inspection involved a total of 12 inspector-hours onsite by two NRC inspectors.
Results: Three areas were inspected. One item of noncompliance was identified in one of the three areas inspected.
(Infraction - failure to follow procedures relative to training and qualification of pile driving inspectors - Section II, paragraph 1.b).
.
7P19511 W iP Y Poe Apoex qc,,g.gs, q
,,,,,,
,
.
.
.
DETAILS I
Licensee Personnel Contacted
- R. Bohn, Manager, Nuclear Staf f
- A. Severance, Nuclear Staff Licensing Supervisor
- J. Dunn, Nuclear Staff Engineer
- E. Kritzer, Quality Assurance Engineer i
Other Personnel Contacted
- E. Barnett, C. F. Braun & Co., Project Manager D. Maxwell, C. F. Braun & Cc., Quality Control Engineer J. Smith, C. F. Braun & Co., Quality Control Inspector
- J. Paulson. Sargent & Lundy, Site Geotechnical Engineer E. Hutson, Thatcher Engineering Corp., Chief, Quality Assurance r~
Functional or Protram Areas Inspected
..
Details of functional or program areas inspected are documented in
"
Sections I and II.
s
.
l i
i i-2-f w
.,, -
n
--
.
=
.
SECTION I j
Prepared by E. J. Gallagher Reviewed by R. L. Spessard, Chief Engineering Support Section 1 1.
Review of Indicator Pile Program Records The purpose of the driving indicator pile program is to provide information to confirm the top of the bearing stratum into which production piling will be driven and for the purpose of confirming the estimated tip elevations for production piles under Category I main building complex. The inspector reviewed the pile driving records for the 49 piles driven between August 7, 1978 to August 17, 1978. The following table includes pertinent information such as, r
pile identification, driving blow counts for the last 5 feet, 1 foot and 1 inch, estimated tip elevation from drawing Nos. S-48, Rev. P, S-49, Rev. T and S-50, actual tip elevation after driving
,
and final cushion thickness recorded. Notes regarding the results of the piles driven are included and reference identified noncon-formance reports issued.
The acceptance criteria established, to date, and subject to change
'
after review of the indicator pile program are as follows:
a.
Driving Criteria: 500 blows for last 5 feet and 100 blows for last 1 foot and 10 blows for last 1 inch b.
Pile Tolerances: pile location: 1 3 inches pile plumbness:
2*. ma::imum pile rotation: 10 degrees c.
Heave Criteria: Piles heaved in excess of 0.01 feet (1/8 inch) shall be redriven by at least the amount of heave to a minimum resistance of 10 blows per inch, or to a maximum of 50 blows per inch.
d.
Piles Section - 14HP117 e.
Piles shall be cut off to provide 3 feet embedment into the foundation base mat.
f.
Cushion thickness criteria not determined to date.
-3-
,
.
. - -
,
.
_
i INDICATOR PILE PROGRAM DATA 8/7/78 to 8/17/78 Date Pile Pile Blow Counts Per Last Estimated Actual Final Tip Tip Cushion Driven ID 5 ft i ft 1 inch Elevation Elevation Thickness (in.)
8/7/78 SA86*
591 319
-55.0-47.98 not measured 8/7/78 SA135**
573 313 49/b"
-55.0-55 not measured 8/7/78 SA59 546 246
-55.0-48.99 not measured
- 0ut-of location tolerance (6 1/4" off) S&L Accepted as is.
(NCR #153C)
- Not continuous driving as required. NCR #190 issued and accepted as is.
-55.0-50.52 not measured 8/8/78 SA9
-
-
8/8/78 A359 568 188/6"
-55.0-47.28 not measured 8/8/78 AB82 510 220
-55.0-48.70 not measured 8/8/78 A3141 514 154
-55.0-50.44 not measured 8/8/78 SC155 637 218
-45.0-44.87 not measured 8/9/78 SF20 8/9/78 SF31 8/9/78 SC47 Did not meet driving criteria established, NCR #193C issued; 8/9/78 SC70 Sargent & Lundy resolution stated, " splice section onto pile 8/9/78 SC107
_,and drive to specified criteria. Length of steel section to 8/9/78 SF63 be spliced is to be determined from results of ongoing indi-cator pile program."
,
8/10/78 AB33 8/10/78 A99 8/10/78 WD140 Did not meet driving criteria established 8/10/78 WD143 Did not meet driving criteria established 8/10/78 WC86 531 179
-36.0-44.2 4 3/8 8/10/78 WE16 655 196
-20.0-25.6
-
8/10/78 WC89 516 246
-30.0-37.98 4 1/2 8/10/78 WC2 787 257/6"
-
-35.0-36.55 3 1/8 8/10/78 WC18 570 339
-30.0-36.3 4 3/8 8/10/78 WB52 519 171
-35.0-34.2 4 1/2 8/11/78 WD4 614 136
-25.0-31.3 4 1/2 8/11/78 WD1 589 265
-25.0-27.9 4 7/8 8/11/78 WC9 531 185
-25.0-39.4 4 1/2 8/11/78 WC42 677 255
-30.0-31.2 4 3/8 8/11/78 WC56 738 283
-30.0-26.2 4 1/8 8/11/78 WC62 560 172
-30.0-48.1 3 1/2 8/11/78 WC76 574 358 107-30.0-41.4 2 1/4
_6_
I
.
.
l i
Date Pile File Blow Counts Per Last Estimated Actual Final Tip Tip Cushion
,
Driven ID 5 ft 1 ft 1 inch Elevation Elevation Thickness (in.)
l
!
8/14/78 WB2 671 189
-35.0-36.52 4 1/2 8/14/78 WC6 617 167
-30.0-33.47 4 1/8
-25.0-37.75 3 5/8 8/14/78 WD12
-
-
-40.0-44.6 4 1/2 8/16/78 WA169
-
-
8/16/78 WB110 545 130
-35.0-33.99 4 1/2 8/16/78 WA177 584 237
-40.0-36.69 4 1/2 8/16/78 WA172 537 196
-40.0-53.15 4 1/2
-55.0-61.28 4 1/4 8/17/78 AB25
-
-
-
-
-60.0-56.09 4 3/8
!
S/17/78 AA130
-60.0-55.49 4 5/8 l
8/17/78 AA66
-
-
-60.0-56.05 5 1/4
-
8/17/78 AA86
-
-
-
-
-60.0-54.05 4 3/8 8/17/78 AA106 23/h"
-60.0-56.15 4 3/8 8/17/78 AA43
-
-
l( 8/17/78 AA2 554 125
-60.0-62.52 4 1/4 Based on discussions with licensee representatives the reasons for the above piles that did not reach the acceptance driving criteria are as follows:
Piles SF20, SF31, SF63, WD140 and WD143 are in general vicinity a.
where previously water jetted test piles were driven. The ef fect of water jetting adjacent to these piles have effected the original estimated bearing stratum, b.
The reason that piles SC47, 70 and 107 did not meet the acceptance driving criteria has not been determined at this time.
No items of noncompliance were identified in the area inspected.
2.
Observation of Pile Driving Work Activities l
The inspectors observed the installation of one 14 HPil7 H-pile l
identified as AB-3 (auxiliary building).
The pile was driven using a Valcan 016 single action steam a.
hammer with a rated energy of 48,750 ft-lb's using a 36 inch stroke.
l b.
The pile was driven from elevation +8.0 with a final driving l
resistance of 523 blows per last 5 feet, 127 blows per last l
foot and 11 blows per last 1 inch. This met the driving acceptance criteria.
,
-5-J
_ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -
-_
__
.
.
!*
c.
The pile cushion was measured after driving and found to be 4 7/8 inches. No acceptance criteria has been determined for the final cushion thickness.
l l
d.
A set graph was taken after the driving resistance was met and included as part of the documentation records.
e.
The contractor placed a reference mark to determine a known-I elevation within 15 minutes as required by the pile. instal-lation procedure.
f.
Pile location, plumbness and rotation tolerance were to be surveyed. Results were not available at the time of inspec-tion.
No items of noncompliance were identified in the area inspected.
?
e
.
-6-
-
'
'
'
-
-
- --
...,.. _... _ _ _ _. _ _
_
_
-. __
.
.
.
<
.
SECTION II Prepared by J. H. Neisler
' Reviewed by D. W. Hayes, Chief Projects Section Review of Thatcher Engineer Corocration Pile Driving Procedures 1.
The inspector reviewed the following procedures relating to pile driving activities being performed by Thatcher Engineering Corporation, a.
Procedure 7-1, Control of Stick and Wire Electrodes b.
Procedure 10-2, Splice Welding c.
Procedure 10-3, Pile Driving Procedure e
d.
Procedure 10-4, In-Lead Splice Inspection Procedure 10-5, H-Pile Inspection Personnel Qualification e.
j and Training f.
Procedure 10-6, Visual Weld Inspection g.
Procedure 10-7, Cut-Off Inspection h.
Procedure 11-2, Vertical Pile Load Test
1.
Procedure 11-3, Lateral Pile Load Test j.
Procedure 12-1, Instrument Calibration k.
Procedure 13-1, Handling, Storage and Transporting 1.
Procedure 14-1, Inspection Plan m.
Procedure 15-1, Nonconformance Reports n.
Procedure 16-1, Corrective Action
2.
The inspector reviewed training and qualification records of Thatcher Engineering Corporation inspection personnel.
It was noted that four inspectors had not been certified to ANSI N45.2.6 Level I qualification.
Training and qualification records did not contain evidence that inspectors had been tested for visual accuity as regtf. red by Pro-cedure 10-5.
This is an infraction.
(367/78-05-01)
Exit Interview The inspectors met with staff representatives (denoted under Persons Contacted) at the conclusion of the inspection on August 13, 1978.
The inspectors summarized the purpose and findings of the inspection.
l
!
l
.