IR 05000326/2022201

From kanterella
Jump to navigation Jump to search
Board of Regents of the University of California – U.S. Nuclear Regulatory Commission Routine Inspection Report No. 05000326/2022201
ML23032A410
Person / Time
Site: University of California - Irvine
(R-116)
Issue date: 02/08/2023
From: Travis Tate
NRC/NRR/DANU/UNPO
To: Stern H
University of California - Irvine
References
IR 2022201
Download: ML23032A410 (14)


Text

SUBJECT:

BOARD OF REGENTS OF THE UNIVERSITY OF CALIFORNIA - U.S. NUCLEAR REGULATORY COMMISSION ROUTINE INSPECTION REPORT NO.

05000326/2022201

Dear Dr. Stern:

From December 13-15, 2022, the U.S. Nuclear Regulatory Commission (NRC) staff conducted an inspection at the University of California, Irvine Nuclear Reactor Facility. The enclosed report presents the results of that inspection, which were discussed on December 15, 2022, with members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspector reviewed selective procedures and records, observed various activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified. No response to this letter is required.

In accordance with Title 10 of the Code of Federal Regulations Section 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

February 7, 2023 Should you have any questions concerning this inspection, please contact Juan Arellano at (301) 415-0477, or by email to Juan.Arellano@nrc.gov.

Sincerely, Travis L. Tate, Chief Non-Power Production and Utilization Facility Oversight Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Docket No. 50-326 License No. R-116 Enclosure:

As stated cc: w/enclosure: See next page Signed by Tate, Travis on 02/07/23

University of California - Irvine Docket No. 50-326 cc:

Dr. Douglas Tobias, Chair Department of Chemistry University of California, Irvine Irvine, CA 92697-2025 Radiologic Health Branch California Department of Public Health P.O. Box 997414, MS 7610 Sacramento, CA 95899-7414 Mr. John Keffer, Reactor Supervisor Nuclear Reactor Facility Department of Chemistry University of California, Irvine 1102 Natural Sciences 2 Irvine, CA 92697-2025 Dr. A.J. Shaka, Reactor Director Nuclear Reactor Facility Department of Chemistry University of California, Irvine 231A Rowland Hall Irvine, CA 92697-2025 Test, Research and Training Reactor Newsletter Attention: Ms. Amber Johnson Dept of Materials Science and Engineering University of Maryland 4418 Stadium Drive College Park, MD 20742-2115 Dr. Howard Gillman, Chancellor University of California, Irvine 510 Aldrich Hall Irvine, CA 92697

ML23032A410 NRC-002 OFFICE NRR/DANU/UNPO/RI NRR/DANU/UNPO/LA NRR/DANU/UNPO/BC NAME JArellano NParker TTate DATE 2/3/2023 2/3/2023 2/7/2023

Enclosure U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION Docket No.:

50-326 License No.:

R-116 Report No:

05000326/2022201 Licensee:

Board of Regents of the University of California Facility:

University of California, Irvine Nuclear Reactor Facility Location:

Department of Chemistry University of California, Irvine, CA Dates:

December 13-15, 2022 Inspectors:

Juan Arellano Kevin Roche Approved by:

Travis L. Tate, Chief Non-Power Production and Utilization Facility Oversight Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation

- 2 -

EXECUTIVE SUMMARY University of California, Irvine Nuclear Reactor Facility Inspection Report No. 05000326/2022201 The primary focus of this routine, announced inspection was the onsite review of selected aspects of the University of California - Irvine, Nuclear Reactor Facility (UCINRF, the licensee)

Class II research reactor facility safety programs including: (1) procedures; (2) experiments; (3)

health physics; (4) design changes; (5) committees, audits and review; and (6) transportation activities. The U.S. Nuclear Regulatory Commission (NRC) staff determined the licensees programs were acceptably directed toward the protection of public health and safety, and in compliance with the NRC requirements.

Procedures

The program for change, control, and implementation of facility procedures was maintained as required by the technical specifications (TSs) and the applicable procedures.

Experiments

The program for reviewing, authorizing, and conducting experiments satisfied TS and procedural requirements.

Health Physics

Surveys were completed and documented as required by procedure.

Postings met the regulatory requirements specified in Title 10 of the Code of Federal Regulations (10 CFR) Part 19, Notices, Instructions and Reports to Workers: Inspection and Investigations, and 10 CFR Part 20, Standards for Protection against Radiation.

Personnel dosimetry was worn and recorded doses were within the NRCs regulatory limits.

Radiation monitoring equipment was maintained and calibrated as required by the TS.

The radiation protection program satisfied regulatory requirements.

Environmental monitoring satisfied license and regulatory requirements.

Design Changes

The licensee reviewed changes using the criteria specified in 10 CFR 50.59, Changes, tests and experiments, and the changes were reviewed by the Reactor Operations Committee (ROC) in accordance with the applicable procedures.

- 3 -

Committee, Audits and Reviews

The review and audit program were conducted as stipulated in TS.

Transportation Activities

Shipments of radioactive material were made in accordance with the applicable regulatory and procedural requirements.

- 4 -

REPORT DETAILS Summary of Facility Status The UCINRF 250 kilowatt TRIGA Mark-I research reactor continued to be operated in support of graduate and undergraduate research and laboratory instruction. During the inspection, the reactor was not operated.

1.

Procedures a.

Inspection Scope (Inspection Procedure (IP) 69001)

The inspector reviewed selected aspects of the following to verify that the licensee complied with the requirements of TS 6.4:

TSs for the U.C. Irvine TRIGA Mark I Nuclear Reactor dated July 7, 2016

UCINRF standard operating procedure (SOP) 1, Introduction, Revision 3.3 approved 2020

UCINRF SOP 4.10, "Miscellaneous Procedures," Revision 3.3 approved 2020

UCINRF SOP 6, "Emergency Procedures," Revision 3.3 approved November 2021 b.

Observations and Findings The inspector reviewed the licensees written procedures and revisions to procedures. The inspector found that the SOP manual was organized to address the full scope of activities conducted at the UCINRF. The inspector noted that procedural changes were reviewed by the ROC as required by TS. Through discussions of various activities at the facility, the inspector found that the licensee personnel conducted activities in accordance with applicable procedures.

c.

Conclusion The inspector determined the licensee maintained and implemented written procedures in accordance with TS requirements.

2.

Experiments a.

Inspection Scope (IP 69001)

The inspector reviewed the following to verify compliance with TSs 3.8, 4.8, and 6.5:

TSs for the U.C. Irvine TRIGA Mark I Nuclear Reactor dated July 7, 2016

UCINRF SOP 3, "Experiments," Revision 3.3 approved 2020

reactor experiment approvals Number (No.) 5, 7, and 9

experiment review report from 2021 - present

select UCINRF irradiation request forms from 2021 - present

- 5 -

select UCINRF irradiation performance forms from 2021 - present

TRIGA Mark I 250 - kilowatt pulsing reactor mechanical maintenance and operating manual dated June 1, 1969

UCINRF SOP, "Instrumental Neutron Activation Analysis," dated August 3, 2022 b.

Observations and Findings The inspector found UCINRF has experimental procedures approved for a broad class of applications. The mission of the UCINRF is primarily to provide irradiation services to researchers, and educational laboratory instruction. New experiments are uncommon. The inspector reviewed how experiments are performed in order to verify compliance with the TS and procedures. Additionally, from review of random samples of forms for experiments performed since the previous inspection, the inspector found that experiments were reviewed and performed in accordance with TS requirements and the licensees written procedures.

c.

Conclusion The inspector determined that experiments were reviewed and performed in accordance with TS requirements and the licensees written procedures.

3.

Health Physics a.

Inspection Scope (IP 69001)

The inspector reviewed the following to verify compliance with 10 CFR Part 19, and 10 CFR Part 20 and TSs 3.7, 4.7, and 6.3 requirements:

UCINRF annual report 2020 - 2021

UCINRF annual report 2021 - 2022

UCINRF SOP 5, "Radiological Safety Program," Revision 3.3 approved 2020

"UCI Nuclear Reactor Checklist for Miller RUA#7001," from 2021 - present

environmental health and safety (EH&S) radiation protection monitoring records from 2021 - present

EH&S swipe records from 2021 - present

reactor DMC3000 Mirion operational check records 2021 - present

environmental monitoring records from 2021 - present

occupational radiation exposure reports from 2021 - present

calibration records for portable detectors from 2021 - present

calibration records for continuous air monitors and area radiation monitors 2021 - present

radiation safety logbook from 2021 - present b.

Observations and Findings (1)

Surveys The inspector reviewed monthly radiation and contamination surveys of the licensee-controlled areas conducted by the licensee staff and

- 6 -

quarterly radiation and wipe surveys completed by campus EH&S Health Physics personnel. The results of the licensee staff surveys were documented on the forms and entered into a Reactor Health Physics notebook which were verified by EH&S. The inspector verified that the results of EH&S surveys were documented on survey maps and forms, and forwarded to the licensee for information.

The inspector directly observed radiation readings and compared the results to the radiation levels observed by the licensee. The readings were comparable, and no anomalies were noted by the inspector.

(2)

Postings and Notices The inspector reviewed the postings at the entrances to various controlled areas including the Control Room and the Reactor Room. The inspector found that the postings indicated the levels of radiation and/or contamination present. Other postings also showed the industrial hygiene hazards present in the areas. The inspector verified the licensee posted the facilitys radioactive material storage areas. No unmarked radioactive material was identified in the facility by the inspector.

The inspector verified the licensee posted copies of current notices to workers, including copies of NRC Form 3, required by 10 CFR 19.11, Posting of notices to workers, on various bulletin boards throughout the facility.

(3)

Dosimetry The licensee used thermoluminescent dosimeters (TLDs) for whole body monitoring of beta and gamma radiation exposure with an additional component to measure neutron radiation. The licensee used TLD finger rings for extremity monitoring. Personal electronic dosimeters were issued to staff and visitors as outlined in licensee procedures and calibrated by EH&S. The licensees issued exposure criteria met or was more restrictive than the requirements of 10 CFR 20.1502, Conditions requiring individual monitoring of external and internal occupational dose, for individual monitoring. The dosimetry was supplied and processed by a National Voluntary Laboratory Accreditation Program accredited vendor.

The inspector reviewed the TLD monitoring results indicating radiological exposures at the facility for the past 2 years. The inspector verified that the highest occupational doses, as well as doses to the public, were well within 10 CFR Part 20 limitations.

(4)

Radiation Monitoring Equipment The inspector reviewed records of selected radiation meters, radiation detectors, and air monitoring equipment in use at the facility. The inspector noted that the calibration of instruments is controlled by EH&S.

The inspector verified that calibrations were completed and that

- 7 -

appropriate calibration records were maintained by the licensee as required.

(5)

Radiation Protection Program The licensees radiation protection program was established in the UCINRF SOP No. 5. The program required that all personnel with unescorted access to work in a radiation area or with radioactive material receive training in radiation protection, policies, procedures, requirements, and facilities prior to entry. The inspector verified that licensee staff received the required radiation protection training given by the Office of EH&S.

The inspector determined the EH&S office completed an annual review of the radiation protection program in accordance with 10 CFR 20.1101, Radiation protection programs, paragraph (c). This audit was accomplished by the campus Radiation Safety Officer.

(6)

Effluent Releases The inspector found gaseous releases were monitored, calculated as prescribed by procedure, and documented in accordance with the TS.

The inspector verified the releases were well within 10 CFR Part 20, Appendix B, Table 2 concentrations, and TS limits. To demonstrate compliance with the annual dose constraints of 10 CFR 20.1101(d), the inspector verified that the licensee used the computational method specified in UCINRF SOP No. 5, section 5.6.

(7)

Facility Tours The inspector toured the Control Room, the Reactor Room, the Pneumatic Tube Laboratory and the Preparation Laboratory within the UCINRF. The inspector verified the control of radioactive material and control of access to radiation and high radiation areas were acceptable.

The inspector determined that the postings and signs for these areas were appropriate.

c.

Conclusion The inspector determined that the radiation protection program implemented by the licensee satisfied regulatory requirements.

4.

Design Changes a.

Inspection Scope (IP 69001)

The inspector reviewed the following to verify compliance with the regulatory requirements of 10 CFR 50.59 were met:

UCINRF annual report 2020 - 2021

UCINRF annual report 2021 - 2022

- 8 -

UCINRF change documentation form 2020-05 dated November 17, 2020

UCINRF change documentation form 2021-01 dated September 14, 2021

UCINRF change documentation form 2021-02 dated August 24, 2021

UCINRF change documentation form 2021-03 dated November 4, 2021

UCINRF change documentation form 2021-04 dated November 15, 2021

UCINRF change documentation form 2021-05 dated November 19, 2021

UCINRF change documentation form 2022-01 dated September 15, 2022

UCINRF change documentation form 2022-02 dated November 18, 2022 b.

Observations and Findings The inspector found that facility changes or modifications were reviewed by the ROC and documented in the committees meeting minutes. TS 6.2.3a requires the review and approval by the ROC of all proposed changes to the facility including those made under 10 CFR 50.59. The inspector verified that the licensee documented changes by requiring a staff evaluation. Completion of the changes or modifications was documented on forms that were developed for that purpose and recorded in the reactor operations logbook, which was also used to document maintenance activities at the facility. The inspector noted that various changes or modifications were implemented by the licensee and subsequently reviewed by the ROC. The documentation and information concerning these changes and modifications were acceptable. Through this review, the inspector verified that the design change process at the facility was functioning and was acceptable for the current operation and staffing of the facility.

c.

Conclusion The inspector determined that changes at the facility were reviewed in accordance with 10 CFR 50.59 and applicable licensee administrative controls.

5.

Committees, Audits and Review a.

Inspection Scope (IP 69001)

The inspector reviewed the following to ensure that the review and audit functions stipulated in the TS:

safety review and audit records for the past 2 years

ROC meeting minutes dated March 4, 2022

ROC meeting minutes dated March 18, 2021

UCINRF supervisors report for 2020

UCINRF supervisors report for 2021 b.

Observations and Findings The inspector verified the ROC membership satisfied TS requirements and the ROC also held annual meetings with a quorum present at those meetings. The inspector found the ROC provided appropriate guidance and direction for reactor operations and ensured suitable use and oversight of the reactor.

- 9 -

The inspector found that EH&S personnel conducted radiation surveys and walk-through tours of the facility which fulfilled the review and audit of radiological safety function of the ROC stipulated in TS 6.2. The inspector determined that the licensee completed and documented all required audits of reactor facility operations and reviews of programs, and procedures.

c.

Conclusion The inspector concluded that the ROC provided the oversight required by the TS.

6.

Transportation Activities a.

Inspection Scope (IP 86740)

The inspector interviewed personnel and reviewed the following to verify compliance with regulatory and procedural requirements for transferred licensed material:

Department of Transportation (DOT) training records from 2020 - present

transfer of radioactive material forms 2021 - present

UCI radioactive sample shipping checklist dated March 15, 2022

shipment records dated March 30, 2021

UCINRF SOP 5.10, "Transportation of Radioactive Material," Revision 3.3 approved 2020 b.

Observations and Findings Through records review and discussions with licensee personnel, the inspector found that the licensee made a shipment of radioactive material since the previous inspection in this area. The inspector verified that the radioisotope types and quantities were calculated and dose rates measured as required. The inspector also found that the shipping containers used were appropriate and showed the appropriate markings as required by Title 49 of the CFR. All radioactive material shipment records reviewed by the inspector were completed in accordance with DOT and NRC regulatory requirements.

c.

Conclusion The inspector determined the radioactive material shipments were made in accordance with the applicable procedures and regulatory requirements.

7.

Exit Interview The inspector presented the inspection results to licensee management at the conclusion of the inspection on December 15, 2022. The inspector described the areas inspected and discussed in detail the inspection observations. The licensee acknowledged the findings presented and did not identify as proprietary any of the material provided to or reviewed by the inspector during the inspection.

Attachment PARTIAL LIST OF PERSONS CONTACTED Licensee A. Shaka Reactor Director J. Keffer Reactor Supervisor R. Dendo UC Irvine Senior Health Physicist A. Chung UC Irvine Health Physicist INSPECTION PROCEDURES USED IP 69001 Class II Non-Power Reactors IP 86740 Transportation ITEMS OPENED, CLOSED, AND DISCUSSED Opened None Closed None Discussed None