SUBJECT:

NOTICE OF VIOLATION (NRC INSPECTION REPORT NO. 50-315/95014(DRP))

Dear Mr. Fitzpatrick:

This refers to the inspection conducted on December 20, 1995, through January 16, 1996, at Donald C.

Cook Nuclear Plant.

The purpose of the inspection was to review the circumstances surrounding your identification on November 20, 1995, that the Unit 1 West Centrifugal Charging Pump (CCP)

had been rendered inoperable by an overcurrent relay, calibration conducted in March 1995.

The report documenting the inspection was sent to you by letter dated January 25, 1996, and you declined an opportunity to participate in a

predecisonal enforcement conference.

Based on the information developed during the inspection and the information that you provided in a Licensee Event Report dated December 20, 1995, and in your response to the inspection report dated February 26, 1996, the NRC has determined that violations of NRC requirements occurred.

The violations are cited in the enclosed Notice of Violation and the circumstances surrounding them are described in detail in the subject inspection report.

On September 12,,1995, while Unit 1 was in a refueling outage with all fuel removed from the reactor vessel, full flow testing of the emergency core cooling system was performed.

During the testing the West CCP tripped on a

sensed overcurrent after 7 minutes of full flow.

Your investigation following the event determined that the time overcurrent relay for the pump had been improperly set since its last calibration on March 15, 1995.

This mis-calibration of the relay rendered the West CCP inoperable until Unit 1 was shut down for the refueling outage on July 30, 1995.

Also, the Unit 1 East CCP was unavailable for approximately 68 hours7.87037e-4 days <br />0.0189 hours <br />1.124339e-4 weeks <br />2.5874e-5 months <br /> during this period.

The primary root cause of the event was the lack of proficiency (requalification training) which led to personnel error on the part of the Instrumentation and Control (18C) technicians.

The lead technician was qualified on the relay in February 1992.

However, the lead technician had not performed any relay calibrations since his qualification and calibrated the relay in March 1995 using a wrong technique.

The second technician was qualified on the relay in August 1993 and had assisted other lead technicians in the performance of this type calibration.

However, he did not question or closely observe the lead technician in the performance of the March 1995 calibration.

j 40039 9603i403i3 9603ii PDR ADQCK 050003i5

PDR L.>G lE.-c I

Al

E. Second, the calibration procedure for the relay remained essentially unchanged since it was written in the mid-1970s.

At that time, technicians specialized in'he calibration of relays and as such the amount of detail required in the procedure was small.

Since then, D.

C. Cook's practice was to have all qualified technicians capable of calibrating relays.

This diluted the proficiency that any one technician would gain.

Therefore, the procedure was not adequate for the current level of proficiency.

The violations represent a significant failure to comply with the action statement for a Technical Specification limiting condition for operation where the appropriate action was not taken within the required time.

Therefore, the violations are classified in the aggregate in accordance with the "General Statement of Policy and Procedure for NRC Enforcement Actions" (Enforcement Policy),

NUREG-1600, as a Severity Level III problem, In accordance with the Enforcement Policy, a base civil penalty in the amount of $50,000 is considered for a Severity Level III problem.

Where there has been escalated enforcement within the past 2 years,Section VI.B.2 of the Enforcement Policy requires consideration of credit for both Identification and Corrective Action.

In this case, credit was warranted for your identification of the violation.

Credit was also warranted for your comprehensive corrective actions.

The West CCP relay was recalibrated and

other relays monitoring motors for pumps that did not receive full flow testing following relay calibration were checked.

Seven additional relays, which were calibrated by the involved second technician and are monitoring an energized bus, will have their calibrations checked once appropriate plant conditions can be established.

The training qualification cards for the involved technicians have been pulled and they will not perform relay calibrations until requalification has been completed.

Additionally, the training program has been enhanced such that during I&C crew training sessions relay calibrations are covered.

Until all technicians have undergone crew training on relay calibrations, only those technicians who have demonstrated proficiency under supervision are performing calibrations on safety related protective relays.

The calibration procedure for the relay has been enhanced.

The concept of the two person wor k team and the responsibilities of the team members are being reinforced with the I&C technicians and the first line supervisors.

Maintenance Standard GEN-02, "First Line Supervisor Pre-Job Activities" is being revised to include the topics of worker proficiency and supervisory guidance, as well as the need to maintain a questioning attitude.

The revised crew train>ng sessions include discussion of the need for all members of the crew performing a task and the personnel reviewing completed work to maintain a questioning attitude.

'

Severity Level IIIviolation (identified on November 11, 1994) was issued on February 28, 1995 (EA 95-002); and a Severity Level IIIviolation (identified on August 22, 1995) was issued on December 8, 1995 (EA 95-219).

E. Therefore, to encourage prompt identification and comprehensive correction of violations, I have been authorized, after consultation with the Director, Office of Enforcement; not to propose a civil penalty in this case.

However, significant violations in the future could result in a civil penalty.

The NRC has concluded'that information regarding the reason for the violations, and the corrective actions taken and planned to correct the violations and prevent recurrence is already adequately addressed on the docket in Inspection Report No. 50-315/95014(DRP),

LER 95-011-00, and your letter dated February 26, 1996.

Therefore, you are not required to respond to this letter unless the description in the docketed materials referenced above does not accurately reflect your corrective actions or your position.

In that case, or if you choose to provide additional information, you should follow the instructions specified in the enclosed Notice.

In'ccordance with 10 CFR 2.790 of the NRC's "Rules of Practice,"

a copy of this letter and its enclosure will be placed in the NRC Public Document Room (PDR).

Sincerely, Docket No. 50-315 License No.

DPR-58 Hu ert J. Hiller Regional Administrator Enclosure:

Notice of Violation cc w/encl:

A. A. Blind, Site Vice President John Sampson, Plant Hanager James R. Padgett, Hichigan Public Service Commission Hichigan Department of Public Health

Ir

E. Therefore, to encourage prompt identification and comprehensive correction of violations, I have been authorized, after consultation with the Director, Office of Enforcement, not to propose a civil penalty in this case.

However, significant violations in the future could result in a civil penalty.

The NRC has concluded that information regarding the reason for the violations, and the corrective actions taken and planned to correct the violations and prevent recurrence is already adequately addressed on the docket in Inspection Report No. 50-315/95014(DRP),

LER 95-011-00, and your letter dated February 26, 1996.

Therefore, you are not required to respond to this letter unless the description in the docketed materials referenced above does not accurately reflect your corrective actions or your position.

In that case, or if you choose to provide additional information, you should follow the instructions specified in the enclosed Notice.

In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice,"

a copy of this letter and its enclosure will be placed in the NRC Public Document Room (PDR).

Sincerely, Docket No. 50-315 License No.

DPR-58 Hubert J. Miller Regional Administrator Enclosure:

Notice of Violation cc w/encl:

A. A. Blind, Site Vice President John Sampson, Plant Manager James R. Padgett, Michigan Public Service Commission Michigan Department of Public Health To receive a copy ot this document, Indicate tn the box:

C

~ Copy without attachment/enclosure E

~ Copy with attachment/enclosure N

~ No copy OFFICE RIII g

RII RIII R

I NAME Pelk Bu Berson on er DATE 03/ / /96 03/

/96 03/

/96 (y~~//(~m OFFICIAL RECORD COPY g, gitjrsfa4r

~ s+<<r/r/rt, Q /96 03/

/96 03f

/96

E. Distribution PUBLIC IE-01 SECY CA JTaylor, EDO JHilhoan, DEDR LChandler, OGC JGoldberg, OGC WRussell, NRR RZimmerman, NRR Enforcement Coordinators RI, RII, RIV JHickman, NRR ABeach, RIII OC/LFDCB Resident Inspector, D.

C.

Cook JGilliland, OPA LNorton, OIG GCaputo, OI EJordan, AEOD OE:EA(2)

MSatorius, OE Docket File DRP State of Michigan RAO:RIII SLO:RIII PAO:RIII INS:RIII