IR 05000284/2009201

From kanterella
Jump to navigation Jump to search
IR 05000284-09-201 on 08/24/2009 - 08/27/2009 for Idaho State University
ML092510333
Person / Time
Site: Idaho State University
Issue date: 09/24/2009
From: Johnny Eads
Research and Test Reactors Branch B
To: Kunze J
Idaho State University
Schoenebeck G, NRR/DPR, 415-6345
References
IR-09-201
Download: ML092510333 (15)


Text

September 24, 2009

SUBJECT:

IDAHO STATE UNIVERSITY - NRC ROUTINE INSPECTION REPORT NO.

50-284/2009-201

Dear Mr. Kunze:

On August 24-27, 2009, the U.S. Nuclear Regulatory Commission (NRC, the Commission)

conducted an inspection at the Idaho State University AGN-201M Reactor Facility (Inspection Report No. 50-284/2009-201). The enclosed report presents the results of that inspection.

This inspection was an examination of activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations of activities in progress. Based on the results of this inspection, no safety concern or noncompliance with NRC requirements was identified. No response to this letter is required.

In accordance with Title 10 of the Code of Federal Regulations Part 2.390 a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC=s document system (Agencywide Document Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at (the Public Electronic Reading Room)

http://www.nrc.gov/reading-rm/adams.html.

Should you have any questions concerning this inspection, please contact Greg Schoenebeck at 301-415-6345 or by electronic mail at Greg.Schoenebeck@nrc.gov.

Sincerely,

/RA/

Johnny H. Eads, Jr., Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation

Docket No. 50-284 License No. R-110

Enclosure:

As stated

cc: See next page

Idaho State University Docket No. 50-284

cc:

Idaho State University ATTN: Mr. Adam Mallicoat Reactor Supervisor Campus Box 8060 Pocatello, ID 83209-8060

Idaho State University ATTN: Dr. Richard T. Jacobsen College of Engineering Dean Campus Box 8060 Pocatello, ID 83209-8060

Idaho State University ATTN: Dr. Richard R. Brey Radiation Safety Officer Physics Department Box 8106 Pocatello, ID 83209-8106

Toni Hardesty, Director Idaho Dept. of Environmental Quality 1410 North Hilton Boise, ID 83606

Test, Research and Training Reactor Newsletter 202 Nuclear Sciences Center University of Florida Gainesville, FL 32611

ML092510333 NRC-002 OFFICE PRTB:RI PRT:LA PRT:BC NAME GSchoenebeck GLappert JEads DATE 9/9/09 9/21/09 9/24/09

U. S. NUCLEAR REGULATORY COMMISSION OFFICE OF NUCLEAR REACTOR REGULATION

Docket No:

50-284

License No:

R-110

Report No:

50-284/2009-201

Licensee:

Idaho State University

Facility:

AGN-201M Reactor Facility

Location:

Pocatello, Idaho

Dates:

August 24-27, 2009

Inspector:

Gregory Schoenebeck

Approved by:

Johnny H. Eads, Jr., Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation

EXECUTIVE SUMMARY

Idaho State University AGN-201M Reactor Facility NRC Inspection Report No. 50-284/2009-201

The primary focus of this routine, announced inspection was the onsite review of selected aspects of the Idaho State University (the licensee) Class II research reactor facility safety programs including: Organization and Staffing; Operations Logs and Records; Requalification Training; Surveillance and limiting conditions for operation (LCO); Emergency Planning; Maintenance Logs and Records; and Fuel Handling Logs and Records, and the Follow-up of Previously Identified Issues. The licensee=s programs were acceptably directed toward the protection of public health and safety, and were in compliance with the U.S. Nuclear Regulatory Commission (NRC) requirements.

Organization and Staffing

  • The organization and staffing was consistent with Technical Specification (TS)

requirements.

Operations Logs and Records

  • Operational activities were generally consistent with applicable TS and procedural requirements.

Requalification Training

  • The licensee was generally meeting the requalification program requirements to ensure the effectiveness of all licensed operators.

Surveillance and LCO

  • The licensees program for completing surveillance inspections satisfied TS and licensee administrative controls.

Emergency Planning

Maintenance Logs and Records

  • Maintenance was performed and logs and records maintained consistent with TS and licensee procedure requirements.

Fuel Handling Logs and Records

  • Fuel handling activities satisfied TS and licensees procedural requirements

- 2 -

Follow-up on Previously Identified Issues

  • The Non-Cited Violation (NCV) 50-284/2007-201-01 will remain an open item until resolution. The Inspector Follow-up Item (IFI) 50-284/2007-201-02 was closed.

REPORT DETAILS

Summary of Facility Status

The licensees Idaho State University (ISU) Aerojet General Nucleonics-201M (AGN-201M)

Reactor Facility, licensed to operate at a maximum steady-state thermal power of 5 Watts (W),

continues to be operated in support of operator training, surveillance, and minor utilization.

During the inspection the reactor was operated for pre-startup checks, but did not startup to achieve criticality due to equipment malfunction.

1.

Organization and Staffing

a.

Inspection Scope (Inspection Procedure [IP] 69001-02.01)

The inspectors reviewed the following to verify compliance with the organization and staffing requirements in Technical Specification (TS) Section 6.1:

  • Idaho State Reactor organizational structure and staffing

Technical Specifications for Idaho State University AGN-201M Reactor (Serial No. 103) dated August 2006

Meeting Minutes of ISU Reactor Safety Committee of March 12, 2009

Letter from Jay Kunze to the NRC, Change in Reactor Supervisory Position, dated June 19, 2009

Letter from Jay Kunze to the NRC, Cancellation of RO License of John Bennion, dated August 27, 2009

Idaho St. University Annual Operating Report for 2008

b.

Observations and Findings

Since the last inspection (NRC Inspection Report No. 50-284/2008-201, Agencywide Documents Access and Management System (ADAMS) No.

ML0819702882), the organizational structure for the reactor facility has changed.

The Reactor Supervisor (RS) position has changed and the qualifications of the incumbent are met as designated in the TS. Including the RS, there are 4 licensed Senior Reactor Operators (SROs) and 2 licensed Reactor Operators (ROs). Review of records verified that management responsibilities were administered as required by TS and applicable procedures. The inspector observed reactor operations on one occasions and noted the shift staffing of the licensee satisfies the requirements for TS.

c.

Conclusions

The organization and staffing was consistent with TS requirements.

- 2 -

2.

Operations Logs and Records

a.

Inspection Scope (IP 69001-02.02)

The inspector reviewed selected aspects of the following to ensure that the operations program was being implemented as required in TS Section 6:

  • ISU AGN-201M Procedure, General Operating Rules, Revision (Rev.) 4, dated October 7, 1994

ISU AGN-201M OP-1, AGN-201 Operating Procedure No. 1, Rev. 3, dated April 26, 1994

Form ROL-101 Page 1, Check Out, Rev. 3, dated April 26, 1994

Form ROL-101 Page 2, Prestart Data, Rev. 3, dated April 26, 1994

Form ROL-101 Page 3, Operational Data, Rev. 3, dated April 26, 1994

ISU AGN-201 Reactor Facility Master Log No.4, November 28, 2006 to April 20, 2008

ISU AGN-201 Reactor Facility Master Log No. 5, April 21, 2008 to Present

b.

Observations and Findings

Reactor operations were carried out according to written procedures and TS requirements. The inspector observed the performance of the required checklist for operation of the reactor. Additionally, a reactor start-up was observed, however malfunction of the high voltage power supply to nuclear instrument channels #2 and #3 occurred during the pre-startup checklist. The facility RS provided troubleshooting oversight and resolved the issue by replacing the faulty equipment. The RS used discretion and did not continue a startup to criticality without proper calibration of the newly installed components.

The inspector noted that the licensed RO and SRO were knowledgeable and competent. The inspector verified that reactor operating characteristics, and other TS and procedure required entries, were recorded on the appropriate forms and logs and that they were performed in accordance with procedure.

Through the review of logs and pre-startup check off lists, (i.e., Form ROL-101)

the inspector noted on several occasions that facility staff and those that are in training were signing into the logbook as a Certified Observer and performing reactor operations that were outside the constrains of TS 1.2, which states a Certified Observer is an individual certified by the Reactor Supervisor as qualified to activate manual scram and initiate emergency procedures. Upon further discussion with the licensee, it appears that it is a nomenclature error as the operators should be identified as Authorized Operators. TS 1.1 states, an Authorized Operator is an individual authorized by the Reactor Supervisor to operate the reactor controls and who does so with the knowledge of the Reactor Supervisor and under the direct supervision of a Reactor Operator. The licensee corrective action is to address this issue during the annual requalification

- 3 -

program training, and to address existing procedures that specify actions of a Certified Observer outside the confines of TS 1.2. The inspector discussed this issue with the Reactor Manager and RS. This item is designated as an Inspector Follow-up Item (IFI) 50-284/2009-201.

c.

Conclusions

Operational activities were generally consistent with applicable TS and procedural requirements.

3.

Requalification Training

a.

Inspection Scope (IP 69001-02.04)

The inspectors reviewed the following to verify compliance with the requirements in Title 10 of the Code of Federal Regulations (10 CFR) Part 55 and the Requalification Program:

  • Technical Specifications for Idaho State University AGN-201M Reactor (Serial No. 103) dated August 2006

Reactor Operator Requalification Program for the Idaho State University Reactor, Rev. 2, dated August 17, 1995

Medical Records for current Reactor Operators and Senior Reactor Operators

Idaho State University Nuclear Engineering Laboratory Requalification Program Progress Checklist, various

Audit of Training, Qualification of ISU Facility Staff, dated 8/21/2009

Letter from John Bennion, Reactor Supervisor to Todd Gansauge, Senior Reactor Operator, Reactor Operator Decertification, dated February 23, 2005

b.

Observations and Findings

The inspector followed-up on the Non-Cited Violation (NCV) 50-284/2007-201-01 (NRC Report 50-284/2007-201, ADAMS # ML072390213) regarding an SRO not meeting the requirements of 10 CFR 55 and continuing to perform licensed actions without oversight. Through interviews with the Reactor Manager and review of operating logs, the inspector determined that the licensed SRO has not been allowed to perform licensed activities without supervision of qualified personnel and is actively engaged in the requalification program.

The inspector also followed-up on the licensees committed actions regarding the aforementioned NCV. The licensee committed to requiring all operators to log their hours of conducting licensed activities, and to routinely review these records to ensure that the operators are meeting the requalification programs requirements. Upon review, it was determined that there is a check-off list to track hours of licensed activities and the completion of required training.

However, it was not completely evident that the operators were logging their

- 4 -

operating hours, nor being routinely reviewed as the licensee had committed. It does appear that the new Reactor Supervisor has committed to restructuring the requalification program to ensure requirements are being met during the current biennial requalification cycle. Therefore, the inspector will leave the NCV 50-284/2007-201-01 item as open, until the commitments are met.

c.

Conclusions

The licensee was generally meeting the requalification program requirements to ensure the effectiveness of all licensed operators.

4.

Surveillance and Limiting Conditions for Operation

a.

Inspection Scope (IP 69001-02.05)

The inspector reviewed the following to ensure that the surveillance requirements and limiting conditions for operation (LCOs) specified in TS Section 4.0 were met:

  • ISU AGN-201M Reactor Facility Master Log #4, various

ISU AGN-201M Reactor Facility Master Log#5, various

24M-3 RSC Audit: Performance, Training, Quals of Staff (TS 6.4.3.b),

dated August 21, 2009

Surveillance Procedure (SP)-1, Calibrate Period, CR and Power Channels, Rev 0 dated December 13, 1988

SP-1A, Checkoff Sheet, dated August 19, 2008

SP-2, Calibrate Period, CR, and Power Channels, Rev 1 dated

October 10, 1988

SP-2A, Check-Off List, dated June 22, 2009

b.

Observations and Findings

The inspector noted that daily, semiannual, and annual checks, tests, and/or calibrations for TS-required surveillance items were completed as required. The LCO verifications were completed on schedule and in accordance with licensee procedures.

c.

Conclusions

The licensee's program for completing surveillance inspections satisfied TS and licensee administrative controls.

5.

Emergency Planning

a.

Inspection Scope (IP 69001)

The inspector reviewed selected aspects of:

- 5 -

Summary of Emergency Exercise involving the ISU Reactor (AGN-201M)

on August 20, 2009-09-03

Memorandum of Understanding (MOU) by and between the Idaho State Police and Idaho State University concerning response to emergencies at Idaho State University involving radiation, dated February 26, 2009

MOU by and between the city of Pocatello and Idaho State University concerning response to emergencies at Idaho State University involving radiation, dated April 16, 2009

MOU by and between Portneuf Medical Center and Idaho State University, dated Apriil 3, 2009

b.

Observations and Findings

The inspector followed-up on an IFI 50-284/2007-201-02 (NRC Inspection Report 50-284/2007-201, ADAMS # ML072390213) regarding the familiarization of the firefighters and police personnel with the reactor facility. The inspector determined that annual training, including a site visit is performed prior to performance of the annual drill. The inspector has determined that IFI 50-284/2007-201-02 is closed.

The licensees Emergency Plan (E-Plan) was verified to be the same as the version most recently approved by the NRC. Emergency preparedness and response training for licensee staff was being completed on an annual basis.

Through drill scenario and record reviews, emergency responders were determined to be knowledgeable of the proper actions to take in case of an emergency. Emergency drills had been conducted annually as required by the E-Plan. Communications capabilities with support groups were acceptable and had been tested as required. Critiques were written following the drills to document the strengths and weaknesses identified during the exercise. Action items were developed to correct the problems identified.

c.

Conclusions

The emergency preparedness program was conducted in accordance with the approved E-Plan.

6.

Maintenance Logs and Records

a.

Inspection Scope (IP 69001-02.11)

The inspector reviewed the following:

  • Maintenance Procedure (MP)-1 AGN-201 Rod Maintenance, Rev. 5 dated June 15, 1994

MP-2 Procedure to Open the AGN-201 Core

- 6 -

  • ISU AGN-201 Reactor Facility Master Log No. 4, November 28, 2006 to April 20, 2008

ISU AGN-201 Reactor Facility Master Log No. 5, April 21, 2008 to Present

b.

Observations and Findings

The inspector reviewed maintenance logs and records and determined that they are maintained as required by licensees administrative procedures and TS.

Maintenance that was performed had been accomplished in accordance with TS and the licensees procedures.

c.

Conclusions

Maintenance logs, records, and performance satisfied TS and procedure requirements.

7.

Fuel Handling Logs and Records

a.

Inspection Scope (IP 69001-02.12

The inspectors reviewed the following to ensure that the licensee satisfied TS and procedural requirements:

  • Maintenance Procedure (MP)-1 AGN-201 Rod Maintenance, Rev. 5 dated June 15, 1994

MP-2 Procedure to Open the AGN-201 Core

ISU AGN-201 Reactor Facility Master Log No. 4, November 28, 2006 to April 20, 2008

ISU AGN-201 Reactor Facility Master Log No. 5, April 21, 2008 to Present

b.

Observations and Findings

The inspector determined that the licensee was maintaining the records of the control rod fuel movements that had been competed and verified that the movements were conducted and recorded in compliance with procedures

c.

Conclusions

Fuel handling activities satisfied TS and licensees procedural requirements.

10.

Follow-up on Previously Identified Issue

a.

Inspection Scope (IP 92701)

The inspector followed up on the NCV 50-284/2007-201-01 (NRC Inspection

- 7 -

Report No. 50-284/2007-201, ADAMS # ML072390213) regarding an SRO not meeting the requirements of 10 CFR 55 and continuing to perform licensed actions without oversight.

The inspector followed-up on an IFI 50-284/2007-201-02 (NRC Inspection Report No. 50-284/2007-201, ADAMS # ML072390213) regarding the familiarization of the firefighters and police personnel with the reactor facility.

b.

Observations and Findings

NCV 50-284/2007-201-01

Through interviews with the Reactor Manager and review of operating logs, the inspector determined that the licensed SRO has not been allowed to perform licensed activities without supervision of qualified personnel and is actively engaged in the requalification program. The inspector followed-up on the committed actions by the licensee with regards to tracking hours of licensed activities and training in accordance to the requalification program, and determined the operators are not documenting their information.

IFI 50-284/2007-201-02

The inspector determined that annual training, including a site visit is performed prior to performance of the annual drill

c.

Conclusion

The NCV 50 -284/2007-201-01 will remain an open item until resolution. The IFI 50-284/2007-201-02 was closed.

14.

Exit Interview

The inspector presented the inspection results to licensee management at the conclusion of the inspection on August 27, 2009. The inspector described the areas inspected and discussed in detail the inspection observations. No dissenting comments were received from the licensee. The licensee acknowledged the observations presented and did not identify as proprietary, any of the material provided to or reviewed by the inspector during the inspection.

PARTIAL LIST OF PERSONS CONTACTED

Licensee

R. Brey

Director, ISU HP Program, Radiation Safety Officer Reactor Manager A. Mallicoat

Reactor Supervisor

Other Personnel

V. Likes

Patrol Captain, Department of Public Safety

INSPECTION PROCEDURES USED

IP 69001

Class II Research and Test Reactors IP 92701

Follow-up

ITEMS OPENED, CLOSED, AND DISCUSSED

OPENED

50-284/2009-201 IFI Correct the terminology of Certified Operator and Authorized

Operators such that it is in accordance with Technical

Specification

CLOSED

50-284/2007-201-02 IFI Site familiarization for firefighters and police

DISCUSSED

50-284/2007-201-01 NCV Requalification program corrective actions

PARTIAL LIST OF ACRONYMS USED

10 CFR

Title 10 of the Code of Federal Regulations ADAMS Agencywide Documents Access and Management System AGN-201M Aerojet General Nucleonics-201M CFR Code of Federal Regulations EP Experimental Plan E-Plan Emergency Plan IFI Inspector Follow-up Item IP Inspection Procedure

- 2 -

ISU Idaho State University LCO Limiting Conditions for Operation MOU Memorandum of Understanding MP Maintenance Procedure NCV Non-Cited Violation NRC Nuclear Regulatory Commission PFD Pocatello Fire Department Rev Revision RO Reactor Operator RS Reactor Supervisor RSC Reactor Safety Committee SP Surveillance Procedure SRO Senior Reactor Operator TS Technical Specification W

Watt