uly 16, 2008

SUBJECT:

NRC INSPECTION REPORT NO. 50-284/2008-201

Dear Dr. Kunze:

On June 23-26, 2008, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at the Idaho State University AGN-201M Research Reactor Facility. The enclosed report documents the inspection results, which were discussed on June 26, 2008, with you and members of your staff.

The inspection examined activities conducted under your license as they relate to safety and compliance with the Commission=s rules and regulations and with the conditions of your license.

The inspector reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.

In accordance with 10 CFR 2.390 of the NRCs, ARules of Practice, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRC=s document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this inspection, please contact Craig Bassett at 404-358-6515.

Sincerely,

/RA/

Johnny H. Eads, Branch Chief Research and Test Reactors Branch B Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No. 50-284 License No. R-110 Enclosure: NRC Inspection Report No. 50-284/2008-201 cc w/enclosure: See next page

Idaho State University Docket No. 50-284 cc:

Idaho State University ATTN: Dr. John S. Bennion Reactor Supervisor Campus Box 8060 Pocatello, ID 83209-8060 Idaho State University ATTN: Dr. Richard T. Jacobsen College of Engineering Dean Campus Box 8060 Pocatello, ID 83209-8060 Idaho State University ATTN: Dr. Richard R. Brey Radiation Safety Officer Physics Department Box 8106 Pocatello, ID 83209-8106 Toni Hardesty, Director Idaho Dept. of Environmental Quality 1410 North Hilton Boise, ID 83606 Test, Research and Training Reactor Newsletter 202 Nuclear Sciences Center University of Florida Gainesville, FL 32611

July 16, 2008 Dr. Jay