U. S. NUCLEAR REGULATORY COMMISSION OFFICE OF IliSPECTION AND ENFORCEMENT P.EGION I Report No.

50-201/79-03 Category RP Docket No.

50-201 License No.

CSF-1 Safeguards Group

~I Nuclear Fuel Services, Incorporated Licensee:

6000 Executive Boulevard Rockville, Maryland 20852 Nuclear Fuel Services, Incorporated Facility Name:

W st Valley, New York Inspection At:

June 12-14, 1979 Inspection Conducted:

December 4-6, 1978 Date of Last Physical Security Inspection Visit:

Type of Inspection:

Unannounced Physical Security Inspectors: _f #.#f I,, /

7-6-77 Date d.11. LaSun, Physical Security Inspector

.& Tfl #U'mm

?* Y

'I<'

Date Lisa M. McKeown, Physical Security Inspector Date h///~14 Appreved by:

ywrt

Od'te

'

'

,S'/'W. Devlin, Chief, Security and Investigation Section, J

afeguards Branch Inspection Summary:

Areas Inspected:

Implementation of accepted security plan and applicable 1.icense Conditions relative to:

Security Plan; Security Organization; Physical Barriers; Access Controls; Keys, Locks and Combinations; Detection Aids; Response Controls; Central Alarm and Communication System; Testing and Maintenance; S!4M Protection; Records and Reports; and Reports of Incidents.

The inspection involved 54 inspector hours onsite by two Regional based NRC inspectors. The inspection was begun during an offshift period; 6 inspection hours were spent during off shift periods.

Resul ts :

The licensee was found to be in compliance with NRC requirements within the 12 areas examined during the inspection with the exception of the following two items:

1.

Detection Aids - A CCTV camera was found which could not meet its performance requirements (Infraction).

2.

Records and Reports - The licensee failed to record the details of alarm response (Deficiency).

8004090221