IR 05000128/2009201

From kanterella
Jump to navigation Jump to search
IR 05000128-09-201, on December 7-10, 2009, Texas a & M University Nuclear Science Center Reactor Facility
ML100070002
Person / Time
Site: 05000128
Issue date: 01/07/2010
From: Johnny Eads
Research and Test Reactors Branch B
To: Hall K
Texas A&M Univ
Bassett C, NRR/DRP/PRT, 404-562-4712
References
IR-09-201
Download: ML100070002 (25)


Text

January 7, 2010

SUBJECT:

NRC ROUTINE INSPECTION REPORT NO. 50-128/2009-201

Dear Dr. Hall:

This letter refers to the inspection conducted on December 7-10, 2009, at the Texas A&M University Nuclear Science Center Reactor Facility. The inspection included a review of activities authorized for your facility. The enclosed report presents the results of that inspection.

Areas examined during the inspection are identified in the report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observation of activities in progress.

Based on the results of this inspection, the NRC has determined that a Severity Level IV violation of NRC requirements occurred. This violation is being treated as a Non-Cited Violation (NCV), consistent with Section VI.A of the Enforcement Policy. The NCV is described in the subject inspection report. If you contest the violation or significance of the NCV, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001, with copies to: the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington DC 20555-0001.

In accordance with Title 10 of the Code of Federal Regulations Section 2.390 Public inspections, exemptions and requests for withholding a copy of this letter, its enclosure, and your response (if any) will be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (Agencywide Documents Access and Management System (ADAMS)).

Adams is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Should you have any questions concerning this inspection, please contact Mr. Craig Bassett at (404) 358-6515 or by electronic mail at Craig.Bassett@nrc.gov.

Sincerely,

/RA/

Johnny H. Eads, Chief Research and Test Reactors Branch B

Division of Policy and Rulemaking

Office of Nuclear Reactor Regulation

Docket No. 50-128 License No. R-83

Enclosure:

NRC Inspection Report No. 50-128/2009-201 cc w/encl:

Please see next page