IE Insp Rept 50-099/82-02 on 820316-18.No Noncompliance Noted.Major Areas Inspected:Radiation Protection Associated W/Dismantling of Facility
ML20053B226
Person / Time
Site: Lynchburg Research Center
Issue date: 04/26/1982
From: Barr K, Peery W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20053B216 List:
References
50-099-82-02, 50-99-82-2, NUDOCS 8205280196
Download: ML20053B226 (3)


Text

_

.

Babcock and Wilcox Company

APR 2 81982 bcc w/o encl:

License Fee Management Branch bcc w/ encl:

Document Management Branch Commonwealth of Virginia RII h /

R RI RII RI j

q WWPeery:ht arr AF son CJulian ong 4/3,6'82 4/p/82

82 4/2'/82 4fX/82

<

8205280/9G t

e-

.

'o,,

UNITED STATES

NUCLEAR REGULATORY COMMISSION

,,

$

E REGION 11

e 101 MARIETTA ST., N.W., SUITE 2100 ATLANTA, GEORGIA 30303

.....

APR 2 81982 Report No. 50-99/82-02 Licensee:

Babcock and Wilcox Company Lynchburg Research Center Lynchburg, VA 24505 Facility Name:

Lynchburg Research Center Docket No. 50-99 License No. R-47

,

Inspection at Lynchburg site near Lynchburg, VA f9 F3 Inspector:__

_ Date Signed W. W. Peery

__

Approved by:

~

h- - #

c/ J (, J L K. P. Bar, Sectio Chief Da Signed Technical Inspection Branch Division of Engineering and Technical Programs SUMMARY Inspection on March 16-18, 1982 Areas Inspected This special, announced inipection involved 16 inspector-hours on site in the area of radiation protection assoc 4ct.ed with the dismantling of the LPR facility.

Results Of the area icipected, no violations or deviations were identified.

I

r_

,

REPORT DETAILS 1.

Persons Contacted Licensee Employees

  • T. Engelder, Laboratory Director
  • A. Olsen, License Administrator M. Baldwin, Supervisor Reactor Operations
  • J. Cure III, Health and Safety Supervisor C. Burnham, Senior Operator D. Harris, Senior Health Physics Engineer K. Long, Accountability Specialist
  • Attended exit interview 2.

Exit Interview The inspection scope and findings were summarized on March 18, 1982, with those persons indicated in paragraph I above.

3.

Licensee Action on Previous Inspection Findings Not inspected.

4.

Unresolved Items Unresolved items were not identified during this inspection.

5.

Disposition of Materials a.

This preliminary inspection revealed that all LPR fuel has been shipped to SR00. Three shipments were made in November 1981 for a total of 25 l

f r1 elements, utilizing a Battelle Columbus Laboratories cask,

!

USA / 5957 B()F, under Certificate of Compliance Number 5957. DOE /NRC

!

Forms 741, Nuclear Materials Transaction Reports were prepared by the licensee and these were reviewed to verify disposal of all LPR fuels.

Form 741s, Nuclear Material Transaction Reports and licensee internal records were reviewed to determine that all neutron sources possessed under the LPR license number R-47 had been transferred to authorized recipients off-site or to the B&W License No. SNM-778. All sources had been transferred.

b.

All major activated components have been removed from the LPR and are l

being held in secured storage pending shipment to an authorized waste l

disposal site.

The remaining radioactivity in the LPR consists of activation products (Eu-152) in the concrete pool walls, metal activa-tion products (primarily Co-60) the majority of which is located in the 8 inch beam port on the interior end of the ports and contaminated l

i

!

-

.

.

resins in the LPR water clean-up system. Removal of activation pro-ducts is continuing and final verification of the absence of license-able material could not be completed at the time of this inspection.

6.

Confirmatory Survey a.

Inspection of licensee records of surveys and decontamination efforts revealed that conscientious efforts have been made, and are continuing, l

to eliminate residual radioactivity. Upon completion by the licensee of dismantling, decontamination and final survey of the LPR, a verifi-cation survey will be performed.

b.

At the time of this inspection samples were obtained of a core drilling from the interior of the LPR pool wall, dust samples from the floor of the pool, smears adjacent to the pool, breathing zone air sample and a liquid waste hold up tank sample for analysis in Region II and compa-rison with licensee analysis results.

The results will be included with all other data in the final close-out inspection report.

.

i l

l l

<

l