Text
January 14, 2015
SUBJECT:
UNIVERSITY OF FLORIDA - NRC SAFETY INSPECTION REPORT NO.
50-083/2014-202
Dear Dr. Jordan:
From December 15-18, 2014, the U.S. Nuclear Regulatory Commission (NRC or the Commission) completed an inspection at your University of Florida Training Reactor facility.
The enclosed report documents the inspection results, which were discussed with you, Mr. Brian Shea, Reactor Manager; and other members of your staff on December 18, 2014.
The inspection examined activities conducted under your license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license.
The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel. Based on the results of this inspection, no findings of significance were identified.
No response to this letter is required.
In accordance with Title 10 of the Code of Federal Regulations, Section 2.390, Public inspections, exemptions, requests for withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRC Public Document Room or from the NRCs document system (Agencywide Documents Access and Management System (ADAMS)). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). Should you have any questions concerning this inspection, please contact Mr. Ossy Font at (301) 415-2490 or electronic mail at Ossy.Font@nrc.gov.
Sincerely,
/RA/
Kevin Hsueh, Chief Research and Test Reactors Oversight Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation
Docket No.50-083 License No. R-56
Enclosure:
Inspection Report No. 50-083/2014-202
cc w/encl: See next page
University of Florida
Docket No.50-083
Administrator Department of Environmental Regulation Power Plant of Siting Section State of Florida 2600 Blair Stone Road Tallahassee, FL 32301
State Planning and Development Clearinghouse Office of Planning and Budgeting Executive Office of the Governor The Capitol Building Tallahassee, FL 32301
Chief, Bureau of Radiation Control Department of Health 4052 Bald Cypress Way Tallahassee, FL 32399-1741
Test, Research and Training Reactor Newsletter Director of Nuclear Facilities University of Florida 202 Nuclear Science Building Gainesville, FL 32611-8300
Brian Shea, Reactor Manager Nuclear & Radiological Engineering Dept 202 Nuclear Sciences Center P.O. Box 118300 University of Florida Gainesville, FL 32611-8300
Cammy Abernathy, Dean University of Florida College of Engineering PO Box 116550 Gainesville, FL 32611