Text

.

.

.

.

/

'o,

UNITED STATES

.O s// *' M'>' 1

  • k

'"*

NUCLEAR REGULATORY COMMISSION aEo'o~ ii

,

pe 10i uan:ETTA ST N.W..$UITE 3100

v4 /-

Art.ANTA. G EoRGIA 3o303 4.....

Special Report: WASTE PACKAGING INSPECTIONS OF LICENSEE-SHIPPERS REPORT NO. 80-13 Reference:

TI 2840/1, (Rev. 1), " Waste Packaging Inspections", 10/10/79 Licensee-Shipper:

Nuclear Metals, Inc., Concord, MA Disposal Site:

Chem-Nuclear Systems, Inc.

P. O. Box 726, Barnwell, South Carolina 29812 Docket No. 15000039 Inspector: 06 2 v_ Mt.

7h

O

-

T. C. MacArthur,, Radiation Specialist, Date Signed FF&.

S ti

, FF&MS Branch

/

Approved by:

-

/f{/

[/d /#

J[. ' Potter, Chief, FF&MS Section, FF&MS Branch

'Date/ Signed

,

SUMMARY Inspection Dates:

June 18, 1980 visit to Chem-Nuclear Waste disposal site, Barnwell, South Carolina for unannounced inspections of licensee-shippers.

Areas Reviewed.:

Each licensee-shipper vehicle was inspected for compliance with Department of Transportation (DOT) and Nuclear Regulatory Commission (NRC) regu-lations as follows:

(1) shipping paper requirements; (2) DOT placarding require-ments; (3) radiation levels; (4) removable contamination; (5) DOT marking and labeling requirements for packages; (6) DOT and NRC requirements for external package features, and (7) prohibited articles or contents.

Results: Of the seven areas inspected one item of noncompliance was found in this shipment.

i

/

8 011060 l'Ag

..

.

e DETAILS 1.

Persons Contacted R. Sappington, South Carolina, DHEC

'

W. House, South Carolina, DHEC V. Autry, South Carolina, DHEC D. Ebenback, CNSI R. C. Franks, NMI E. J. Kosinski, NMI 2.

General The NRC inspection consisted of a review of the shipping papers, radiation survey of the vehicle, contamination surveys and radiation level surveys of selected packages.

General su rveys and observations were conducted to determine if the vehicle had proper placards, proper seals, and if any obvious safety hazards existed. The contents of the vehicles were inspected for appropriate marking, labeling, tightness of seals, integrity of package construction or any evidence of leakage.

-

Chem-Nuclear assigns a control number for each shipment upon arrival at the site. These numbers were called " shipment survey report numbers" (SSR No.)

and were used by the inspectors to identify licensee-shippers during this inspection.

3.

Shipments, Inspected On June 18, 1980 a shipment designated as drums of radioactive material low specific activity LSA NOS depleted uranium scrap was delivered to the site from Nuclear Metals, Inc. of Concord, MA by Spector, trailer number 24135. The shipment consisted of 80 drums; 13 designated as oxides, 16 as trash, and the remainder as chips in cement. Radiation surveys conducted by Nuclear Metals personnel on June 13, 1980 indicated radiation levels in the operator's cab to be less than 0.1 mR/hr. Upon arrival at the Chem Nuclear burial site at Barnwell, SC., three independent surveys at different times by Chem Nuclear personnel, State of South Carolina DHEC representatives, and NRC inspector showed readings of 5 mR/hr in the operator's cab.

These values are in excess of the maximum allowed level of 2 mR/hr as prescribed by 49CFR173.393(J)(4).

A radiation level of this magnitude constitutes a Severity I violation. *

4.

Shipping Papers The shipping papers were reviewed for completeness and to ascertain if the contents of the shipment were properly identified, and if emergency notifi-

.

..

.

.

.

.

.

-2-cation procedures and instructions were included as required under 49 CFR 172, Subpart C.

Specific requirements for shipping papers were reviewed as follows:

,

Material shipping name 49 CFR 172.100/172.200/172.202

-

Material class 49 CFR 172.200/172.202

-

Name sequence 49 CFR 172.200/172.202

-

Total quantity-(volume)

49 CFR 172.200/172.202

-

Limited quantity 49 CFR 172.200/172.203

-

Name of each radionuclide

-

49 CFR 172.203 Physical and chemical form 49 CFR 172.203

-

Activity in curies 49 CFR 172.203

-

Category or label 49 CFR 172.203

-

Notation of NRC/ERDA package approval 49 CFR 172.203

-

Proper certification

-

49 CFR 172.204 In addition to the above, 49 CFR 177.817 requires carriers to maintain the above shipping papers readily available for inspection and reccgnizable by authorities in case of an accident.

,

No items of noncompliance were identified.

5.

Each vehicle was inspected for conformance with DOT placarding requirements (49 CFR 172, Subpart F and 49 CFR 173.392). The vehicles were also inspected for compliance with the following:

Maximum transportation index of 50 - (49 CFR 177.842)

Loaded so as to avoid spillage (49 CFR 177.842)

Properly blocked and braced (49 CFR 173.392/177.842)

LSA vehicle survey (49 CFR 177.843)

No items of noncompliance were identified.

6.

Maximum Radiation Levels Each truck was surveyed for maximum radiation levels in the normally occupied portions of the vehicle, at the vertical plane of the flat bed or at the sur-face of closed vehicles, in a vertical plane six feet from the sides of the vehicle where possible, and on the surface of a representative package.

One vehicle was in noncompliance with 49 CFR 173.393 limits.

.

r

-

-

)

..

.

..

<

,

.

-3-

.

7.

Packaging A representative sampling of packages from each shipment was examined for conformance with DOT marking and labeling requirements,. External features of the packages were examined for conformance with DOT and NRC requirments as noted below:

Low specific activity (LSA) packaging 49 CFR 173.392

-

Tight packages - Ltd. Qty.,

49 CFR 173.391 or 173.392

-

No release of material 49 CFR 173.392/173.393

-

Radioactive material markings 49 CFR 172.310

-

Security seals 49 CFR 173.393

-

Gross weight requirements

-

49 CFR 172.310 Proper shipping name 49 CFR 172.100/172.300

-

LSA labeling

-

-

49 CFR 173.392 Cask design specifications

-

49 CFR 173.38

..

l

.

B e