IR 015000014/2025001

From kanterella
Jump to navigation Jump to search
Olsson - NRC Forms 591M and 592M, Inspection Report 15000014/2025001
ML25133A132
Person / Time
Site: 15000014, 015000014
(IA-0377-1-77-IR1)
Issue date: 05/13/2025
From: Tindle-Engelmann E
NRC/RGN-III/DRSS/MIB
To: Krueger K
Olsson
References
IR 2025001
Download: ML25133A132 (1)


Text

NRC FORM 591M (09-11-2024)

Materials Inspection Report U.S. NUCLEAR REGULATORY COMMISSION Page 1 of 1

Add Continuation Page Licensee/Location Inspected:

Olsson 1717 Ingersoll Avenue, Suite 111 Des Moines, IA 50309

TJS (on 4/16/2025): LRN 686113 Report Number(s) 2025001 NRC/Regional Office Region III U. S. Nuclear Regulatory Commission 2056 Westings Avenue, Suite 400 Naperville, IL 60563-2657 Docket Number(s)

150-00014 License Number(s)

IA-0377-1-77-IR1 Date(s) of Inspection 02/10/2025 - 04/23/2025 LICENSEE:

The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follows: Based on the inspection findings, no violations were identifie. Previous violation(s) closed. During this inspection, certain of your activities, as described below and/or attached, were in violation of NRC requirements, and were assessed at Severity Level IV, in accordance with the NRC Enforcement Policy. The following violation(s) is/are being cited in accordance with NRC Enforcement Policy. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance with 10 CFR 19.1 (Violations and Corrective Actions)

Statement of Corrective Actions I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identifie This statement of corrective actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken, date when full compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requested. The violation(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-identified, non-repetitive, corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy were satisfie (Non-cited violation(s) was/were discussed involving the following requirement(s)

TITLE NRC INSPECTOR PRINTED NAME SIGNATURE AND DATE LICENSEE'S REPRESENTATIVE Kurt Krueger Elizabeth Tindle-Engelmann BRANCH CHIEF Rhex Edwards ELIZABETH TINDLE-ENGELMANN Digitally signed by ELIZABETH TINDLE-ENGELMANN Date: 2025.04.23 08:16:53 -05'00'

Digitally signed by RHEX EDWARDS Date: 2025.05.13 08:21:19 -05'00'

NRC FORM 592M (10-04-2022)

U.S. NUCLEAR REGULATORY COMMISSION Materials Inspection Record Page 1 of 2 NRC Form 592M (10-04-2022) Licensee Name:

Olsson Docket Number(s):

150-00014 License Number(s)

IA-0377-1-77-IR1 Report Number(s):

2025001 Date(s) of Inspection:

02/10/2025 - 04/23/2025; TJS on 4/16/2025 Inspector(s):

E. Tindle-Engelmann, G. Warren Program Code(s):

03320 Priority:

1 Inspection Guidance Used:

87121 1 Licensee Contact Name(s):

Kurt Krueger 1 Licensee E-mail Address:

kkrueger@olsson.com 1 Licensee Telephone Number(s):

832-775-2981 1 Inspection Type:

Initial Routine

Announced

Non-Routine Unannounced 1 Locations Inspected:

Hybrid

Main Office Field Office Temporary Job Site

Remote 1 Next Inspection Date (MM/DD/YYYY):

TBD Normal Reduced Extended No change

1 Location(s) Inspected List:

TJS: LRN 686113 1 Scope and Observations:

This inspection included in-office review of records and a temporary job site inspection for a non-destructive testing company authorized by the State of Iowa to use lridium-192 (lr-192) for industrial radiography at temporary job sites within Iowa jurisdiction. The licensee conducted these activities at temporary job sites in NRC jurisdiction under the terms of a reciprocity request filed in January of 2025 for calendar year 2025 and amended as needed throughout the year. In office review of records was conducted between 02/10/2025 and 04/23/202 The scope of this inspection included an evaluation of the licensee's activities at a TJS in Kansas City, Missouri, on 04/16/2025. During the TJS inspection, one radiographer and one radiography assistant performed a series of shots to evaluate pipe welds using a radiographic device (camera) as described on the NRC Form 241 and the State of Iowa license. During the TJS inspection, the inspector observed licensee staff arrive on site and check in with site management; perform daily checks on the radiographic equipment; verify calibration dates and proper operation for survey meters, alarming ratemeters, and direct-read dosimeters; remove the camera from the vehicle; place labeled cones at appropriate locations to establish radiation and high radiation areas; set up the camera; take multiple shots; maintain surveillance of the camera at all times; control the area during and between shots; challenge an individual approaching the marked radiation area; survey the boundaries during shots; survey the guide tube of the camera after each shot; return the camera to shielded and secured storage; survey the vehicle; check the direct-read dosimeters after completing work; develop and evaluate film; and fill out use log/shipping paperwork to return the camera to the permanent storage site. Licensee staff wore required dosimetry and appropriate personal protective equipment for the job site. Interviews with the radiographer and radiography assistant indicated adequate knowledge of radiation safety concepts and procedure Select record were reviewed including the following: annual program reviews, dosimetry, GPS coordinates of radiography vehicles, NRC Form 241s, sealed source leak tests, sealed source inventory, shipping papers, training, and use log NRC FORM 592M (10-04-2022)

U.S. NUCLEAR REGULATORY COMMISSION Materials Inspection Record (Continued)

Page 2 of 2 NRC Form 592M (10-04-2022)

Independent surveys were performed throughout the TJS inspection using a RadEyeG (SN: 30626, calibration due:

05/14/2025). Survey results were below applicable regulatory limit No violations above minor safety significance were identified as a result of this inspectio Signature and Date - Branch Chief Digitally signed by RHEX EDWARDS Date: 2025.05.13 08:20:57 -05'00'