HBL-98-013, Forwards 10CFR50.59 Annual Rept of Changes,Tests & Experiments for Jan-Dec 1997. Encl Annual Rept Provides Brief Description of 10CFR50.59 Facility Design Changes, Including Summary of Each SE

From kanterella
(Redirected from HBL-98-013)
Jump to navigation Jump to search
Forwards 10CFR50.59 Annual Rept of Changes,Tests & Experiments for Jan-Dec 1997. Encl Annual Rept Provides Brief Description of 10CFR50.59 Facility Design Changes, Including Summary of Each SE
ML20195F447
Person / Time
Site: Humboldt Bay
Issue date: 11/10/1998
From: Moulia T
PACIFIC GAS & ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20195F452 List:
References
HBL-98-013, HBL-98-13, NUDOCS 9811190267
Download: ML20195F447 (3)


Text

-

.a ..

Pacific Gas and Electric Company 10W King Sahnon Avenue Humboldt Bay P:werPlant Eureka CA 95$03 TOM A. MOULIA '

Plant Manager November 10,1998  ;

1

)

)

PG&E Letter HBL-98-013 U.S. Nuclear Regulatory Commission j ATTN: Document Control Desk l l

Washington, D.C. 20555 Docket No. 50-133, OL-DPR-7 l

Humboldt Bay Power Plant, Unit 3 i 10 CFR 50.59 Annual Report of Changes. Tests. and Exneriments for January I through i December 31.1997

Dear Commissioners and Staff:

Pursuant to 10 CFR 50.59, enclosed is the Annual Report of Changes, Tests, and Experiments j for Humboldt Bay Power Plant, Unit 3 (HBPP) for the reporting interval January I through -

December 31,1997.

Channes in the Facility as Described in the SAESTOR Decommissioning Plan (SDP)

The enclosed annual report provides a brief description of the 10 CFR 50.59 facility design changes, including a summaiy of each safety evaluation. Each change was reviewed and accepted by the Plant Staff Review Committee (PSRC).

Changes in Procedures as Described in the SD._P The enclosed annual report provides a brief description of the 10 CFR 50.59 procedure changes, including a summary of each safety evaluation. Each change was reviewed and accepted by the PSRC.

l Tests and Exocriments Not Described in the SDP No tests or experiments were performed during the reporting period that are not described in the SDP.

i i nO Sm ,- g( '

9811190267 981110

~'

[DR ADOCK 05000133 PDR j d

l:!"M Document Control Desk ^

PG&E Letter HBL-98413 -

' November 10,1998 Page 2 p .,  :,'-

%c PSRC determined that none of the design changes or procedure changes invoi 'ed an unreviewed safety question or a change to the HBPP Technical Specifications.

. Sinc ely,- .

4 TOM A. MO LIA ~-

I~

cc: Ellis W. Merschbff Louis L. Wheeler

' Enclosure 1

o l

., j

f PG&E letter HBL-98-013 bec: Marna Colcun I D;vid Sokolsky DCPP BASES HD ACTS Library (DCPP 104/5/2A)  !

l I

1 1

. 1 i

I I

l I

I l

.