GO2-92-115, Monthly Operating Rept for Apr 1992 for WNP-2
| ML17289A554 | |
| Person / Time | |
|---|---|
| Site: | Columbia |
| Issue date: | 04/30/1992 |
| From: | John Baker, Hutchison L WASHINGTON PUBLIC POWER SUPPLY SYSTEM |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| GO2-92-115, NUDOCS 9205210298 | |
| Download: ML17289A554 (7) | |
Text
. ACCELERATED DISTRIBUTION DEMONSTION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
FACIL:50-397 WPPSS Nuclear Project, Unit 2, Washington Public Powe AUTH.NAME AUTHOR AFFILXATXON HUTCHISON,L.
Washington Public Power Supply System BAKER,J.W.
Washington Public Power Supply System RECIP.NAME RECXPIENT AFFILIATION DOCKET I 05000397
SUBJECT:
Monthly operating rept for Apr 1992 for WNP-2. /920506 tr.
DISTRIBUTION CODE:
XE24D COPIES RECEIVED:LTR ENCL SIZE:
TITLE: Monthly Operating Report (per Tech Specs)
NOTES:
D
~
RECXPXENT ID CODE/NAME PD5 LA DEAN,W.
INTERNAL: ACRS AEOD/DSP/TPAB NRR/DOEA/OEAB RGN5 EXTERNAL EG&G BRYCE IJ ~ H NSXC COPIES LTTR ENCL 3
3 1
1 10 10 1
1 1
1 1
1 1
1 1
1 RECIPXENT ID CODE/NAME PD5 PD AEOD/DOA NRR/DLPQ -LBE 0
cmrBR- -
o RC PDR COPIES LTTR ENCL 1
1 1
1 1
1 1
1 1
1 D
D 5 2.// gg D
NOTE TO ALL"RIDS" RECIPIENTS:
A D
D PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED:
LTTR 24 ENCL 24
WASHINGTONPUBLIC POWER SUPPLY SYSTEM P.O. Bm968 ~ 3000George Wasbtngton Way ~ Rtcbland, Wasbtngton 99352<968
~ (509)372-5000 Docket No. 50-397 May 6, 1992 G02-92-115 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.
20555
Dear Sir:
Subject:
NUCLEAR PLANTNO. 2 MONTHLYOPERATING REPORT APRIL 1992 Transmitted herewith is the Monthly Operating Report for the month of April 1992 as required by our Technical Specifications 6.9.1.6.
Very truly yours,
. Baker WNP-2 Plant Manager (MD 927M)
LBH:bap Enclosure CC:
Mr. W.H. Lovelace, NRC, Washington DC Mr. J,B. Martin, NRC Region V Ms. Dottie Sherman, ANI, Farmington CT Mr. C. Sorensen, NRC Resident Inspector (901A)
Mr. J.T. Wheelock, INPO Mr. F. Yost, UtilityData Institute 9205210298 920430 j
0 i.AA".'DR ADOCK 05000397 R
PDR" gp]o
(~~~zi(P gp<
'J ~
I
"~V'<,~Pm+
OPERATING DATA REPORT WNP-2 DATE 01-May-92 1.
DOCKET: 50-397 2.
REPORTING PERIOD:
Apr-92 3.
UTILITY CONTACT:
OUTAGE + ON-LINE HOURS LEONARD HUTCHISON (509) 377-2486 719 4.
LICENSED THERMAL POWER (MWt):
5.
NAMEPLATE RATING (GROSS MWe):
6.
DESIGN ELECTRICAL RATING (NET MWe):
7.
MAXIMUM DEPENDABLE CAPACITY (GROSS MWe):
8.
MAXIMUM DEPENDABLE CAPACITY (NET MWe):
9 ~
IF CHANGES OCCUR ABOVE SINCE LAST REPORT I GIVE REASONS None.
3323 1200.9 1100 1129 1085 10.
POWER TO WHICH RESTRICTED, IF ANY (NET MWe):
11.
REASONS FOR RESTRICTIONS, IF ANY:
12.
REPORT PERIOD HOURS 13.
HOURS REACTOR CRITICAL 14.
RX RESERVE SHTDWN HRS 15.
HRS GENERATOR ON LINE 16.
UNIT RESERVE SHUTDOWN HOURS 17.
GROSS THERMAL ENERGY (MWH) 18 'ROSS ELECTRICAL ENERGY (MWH) 19.
NET ELECTRICAL ENERGY (MWH) 20.
UNIT SERVICE FACTOR 21.
UNIT AVAILABILITYFACTOR 22.
UNIT CAPACITY FACTOR (MDC NET) 23.
UNIT CAPACITY FACTOR (DER NET)
- 24. UNIT FORCED OUTAGE RATE 25.
FORCED OUTAGE HOURS MONTH 719 416. 0 0.0 410. 6 0.0 1337639 452340 430411 57.14 57.14 55.24
- 54. 4>o
- 0. 04 0.0 YEAR 2903 2085.0 0.0 2042.6 0.0 6588250 2233530 2135947 70.44
- 70. 4~o 67.84 66.9l 21.
34'52.0 CUMULATIVE 64687. 2 45475.7 340.4 43842.5 381. 7 126204072 42089350 40393986 67.84 68.4<
57.1<
56.84
- 13. 5~0 6855.8 26 ~
SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE i DATEi DURATION)
None.
- 27. IF CURRENTLY SHUTDOWN ESTIMATED STARTUP DATE:
7/1/92
DOCKET NO.:
50-397 UNITNAME:
WNP-2 DATE:
MAY,1, 1992 COMPLETED BY:
LB HUTCHISON TELEPHONE:
(509) 377-2486 UNIT SHUTDOWN / REDUCTIONS REPORT PERIOD: APRIL I 92 NO.
DATE TYPE HOURS REASON METHOD LER NO SYSTEM COMPONENT CAUSE &CORRECTIVE ACTIONTO PREVENT RECURRE E
92-03 4/18/92 S
308.4 C
RC FUEL XX Plant was shutdown as scheduled for refueling outage R-7.
$UMlHARY: WNP-2 operated routinely until April 18, 1992 when it was shutdown for refueling outage R-7.
TYPE REASON METHOD SYSTEM &COMPONENT F-FORCED S-SCHED A-EQUIP FAILURE B-MAINTOR TEST C-REFUELING D-REGULATORYRESTRICTION E-OPERATOR TRAINING&
LICENSE EXAM F-ADMIN G-OPER ERROR H-OTHER 1-MANUAL 2-MANUALSCRAM 3-AUTO SCRAM 4-CONTINUED 5-REDUCED LOAD 9-OTHER EXHIBITF &H INSTRUCTIONS FOR PREPARATION OF DATAENTRY SHEET LICENSEE EVENT REPORT (LER) FILE (NUREG-0161)
~
~
A GE DAILYUNITPOWER L L
MONTH:
APRIL 1992 DOCKET NO.:
UNIT:
DATE:
COMPLETED BY:
TELEPHONE:
50-397 WNP-2 APRIL 1992 LB HUTCHISON (509) 377-2486 DAYAVERAGEDAILYPOWER LEVEL (MWe-NET)
DAYAVERAGE DAILYPOWER LEVEL (MWe-NET) 1078 17.
865 2.
1077 18.
1072 19.
4, 1088 20.
5.
1086 21.
6.
1093 22.
1094 23.
1091 24.
9.
1085 10.
1055 26.
1067 27.
12.
1083 28.
13.
1076 29.
14.
1075 30.
15.
1076 31.
16.
1070 INSTRUCTIONS ON THIS FORM, LIST THE AVERAGE DAILYUNIT POWER LEVEL IN MWe-NET FOR EACH DAY IN THE REPORTING MONTH. COMPUTE TO THE NEAREST WHOLE MEGAWATT.
THESE FIGURES WILLBE USED TO PLOT A GRAPH FOR EACH REPORTING MONTH. NOTE THAT WHEN MAXIMUMDEPENDABLECAPACITYIS USED FOR THE NET ELECTRICALRATINGOF THE UNIT,THRE MAY BE OCCASIONS WHEN THE DAILY AVERAGE POWER LEVEL EXCEEDS THE 100Fo LINE (OR THE RESTRICTED POWER LEVELLINE). IN SUCH CASES, THE AVERAGE DAILYUNITPOWER OUTPUT SHEET SHOULD BE FOOTNOTED TO EXPLAINTHE APPARENT ANOMALY.