| Event Description | The following information was provided by the licensee via phone and email:
The facility is in a safe and stable configuration. Additionally, the facility is not [and] has never been in a flooded state, and no accident has occurred. Urenco USA has stored three end-of-life uranium hexafluoride traps in the ventilated room on the first floor of the cylinder receipt and dispatch building (CRDB). These traps were previously installed in the system on the second floor of the process services corridor (PSC). While installed, these traps have been analyzed as safe for movement and interaction without any external controls. Flooding is not considered a credible event for the second floor of the PSC. However, these traps have been moved to the first floor of the CRDB for storage where flooding is a credible event. A first-floor condition of flooding with the traps has not been modeled in the nuclear criticality safety analysis (NCSA). The storage of traps in the first-floor ventilated room potentially falls outside of the normal operating conditions analyzed in NCSA and integrated safety analysis (ISA) related documentation and results in the facility being in a state that was different from analyzed in the ISA. Corrective actions have begun. The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance: Personnel access to the area has been restricted pending completion of the evaluation. |
| Where | |
|---|---|
| Louisiana Energy Services Eunice, New Mexico (NRC Region 2) | |
| License number: | SNM-2010 |
| Reporting | |
| Part 70 App A (B)(1) | |
| Time - Person (Reporting Time:+17.87 h0.745 days <br />0.106 weeks <br />0.0245 months <br />) | |
| Opened: | Barry Love 13:40 Jul 27, 2025 |
| NRC Officer: | Ernest West |
| Last Updated: | Jul 27, 2025 |
| 57829 - NRC Website | |
Louisiana Energy Services with Part 70 App A (B)(1) | |
WEEKMONTHYEARENS 578292025-07-26T19:48:00026 July 2025 19:48:00
[Table view]Part 70 App A (B)(1) Unanalyzed Condition ENS 578082025-07-10T19:30:00010 July 2025 19:30:00 Part 70 App A (B)(1) Unanalyzed Condition ENS 576262025-03-25T21:15:00025 March 2025 21:15:00 Part 70 App A (B)(1) Unanalyzed Condition ENS 566702023-08-08T20:22:0008 August 2023 20:22:00 Part 70 App A (B)(1) Unanalyzed Condition ENS 558022022-03-25T19:30:00025 March 2022 19:30:00 Part 70 App A (B)(1) Instances of Unanalyzed Conditions ENS 538922019-02-22T01:45:00022 February 2019 01:45:00 Part 70 App A (B)(1) Irofs Surveillance Periodicity Error ENS 534452018-06-05T06:00:0005 June 2018 06:00:00 Part 70 App A (B)(1) En Revision Imported Date 7/12/2018 ENS 531832018-01-25T19:00:00025 January 2018 19:00:00 Part 70 App A (B)(1) Potential Deficiency Associated with an Item Relied Upon for Safety ENS 509382015-03-27T22:30:00027 March 2015 22:30:00 Part 70 App A (B)(1) Accumulation of Sample Cylinders in the Chemistry Lab Exceeds Amount Allowed ENS 471312011-08-05T22:30:0005 August 2011 22:30:00 Part 70 App A (B)(1) Material Discovered in an Unanalyzed Container 2025-07-26T19:48:00 | |