ENS 55583
ENS Event | |
|---|---|
06:00 Nov 15, 2021 | |
| Title | Abnormal Occurrence |
| Event Description | University Of Missouri Research Reactor (MURR) Technical Specification (TS) 6.6.c(1) requires notification to the NRC Operations Center that an Abnormal Occurrence, as defined by MURR TS 1.1, has occurred. MURR was not in compliance with one (1) of the TS Limiting Conditions of Operations. TS 3.2.g states, 'The reactor safety system and the number (N) of associated instrument channels necessary to provide the following scrams shall be operable whenever the reactor is in operation.' Specifically, the reactor safety scram function that occurs when the differential pressure across the reactor pool reflector (PT-917) instrument channel decreases below 2.52 psi minimum in Mode 1 operation was not operable as required by TS 3.2.g.10.
On 11/15/21 while the reactor was shut down, Control Room operators shut down the pool coolant system and noticed that the `Reflector Hi-Low Diff Pressure Scram' annunciator alarm did not initiate as pool coolant flow rate decreased to zero. The Control Room operators contacted reactor management, and an investigation was initiated to prove whether or not the safety scram function from the PT-917 instrument channel actuated correctly. Further testing revealed the safety scram signal from the PT-917 instrument channel did not occur due to a failed alarm-meter unit. The alarm-meter unit was replaced with an exact spare, the PT-917 instrument channel was calibrated, and the reactor safety scram functions of the PT-917 instrument channel were retested satisfactorily. In accordance with TS 6.6.c(4), the Reactor Facility Director was briefed and gave permission to restart the reactor prior to the reactor returning to operation later on 11/15/21. Currently, MURR is operating at 10 MW. A detailed event report will follow within 14 days as required by MURR TS 6.6.c(3). The NRC Project manager was notified. |
| Where | |
|---|---|
| University of Missouri-Columbia Columbia, Missouri (NRC Region 0) | |
| License number: | R-103 |
| Reporting | |
| Non | |
| Time - Person (Reporting Time:+33.98 h1.416 days <br />0.202 weeks <br />0.0465 months <br />) | |
| Opened: | Bruce Meffert 15:59 Nov 16, 2021 |
| NRC Officer: | Kerby Scales |
| Last Updated: | Nov 16, 2021 |
| 55583 - NRC Website
Loading map... | |
University of Missouri-Columbia with Non | |
WEEKMONTHYEARENS 573822024-10-14T19:00:00014 October 2024 19:00:00
[Table view]Non Noncompliance with Technical Specification ENS 571802024-06-17T05:00:00017 June 2024 05:00:00 Non Noncompliance with Technical Specification ENS 571252024-05-10T05:00:00010 May 2024 05:00:00 Non Technical Specification Violation ENS 565342023-05-23T13:45:00023 May 2023 13:45:00 Non Technical Specification Violation ENS 562962022-09-22T18:00:00022 September 2022 18:00:00 Non Technical Specification Violation ENS 555832021-11-15T06:00:00015 November 2021 06:00:00 Non Abnormal Occurrence ENS 555682021-11-08T06:00:0008 November 2021 06:00:00 Non Technical Specification Violation ENS 555162021-10-11T05:00:00011 October 2021 05:00:00 Non One Primary Coolant LOW Pressure Instrument Channel Scram Setpoint Found Below Technical Specification Required Minimum 2024-06-17T05:00:00 | |