ENS 55516
ENS Event | |
|---|---|
05:00 Oct 11, 2021 | |
| Title | |
| Event Description | [This notification is required] per University Of Missouri Research Reactor (MURR) Technical Specification (TS) 6.6.c(1) to report to the NRC Operations Center that an Abnormal Occurrence, as defined by MURR TS 1.1, had occurred. MURR was not in compliance with one (1) Limiting Conditions of Operations (LCO). TS 3.2.g. which states, 'The reactor safety system and the number (N) of associated instrument channels necessary to provide the following scrams shall be operable whenever the reactor is in operation..' TS 3.2.g.6 requires four (4) Primary Coolant Low Pressure reactor safety system instrument channels provide a reactor scram when the primary coolant pressure corresponding to the pressurizer during normal flow drops below 75 psia. Surveillance testing on 10/11/2021 revealed that one (1) of the four (4) channels was not operable.
On 10/11/21 while the reactor was shutdown for maintenance and conducting surveillance testing on the reactor core outlet pressure channels, the surveillance testing revealed that the reactor core outlet pressure channel associated with pressure transmitter 944B did not provide a reactor scram at an appropriate TS low pressure setpoint. On 10/11/21, the Primary Coolant Low Pressure reactor safety instrument channel 944B scram setpoint was calculated to be 74.43 psia which is slightly below the required 75 psia minimum. Previously on 4/12/2021, the Primary Coolant Low Pressure reactor safety instrument channel 944B scram setpoint was calculated to be 76.94 psia which is within the TS-required setpoint range. So, sometime between 4/12/2021 and 10/11/2021, the reactor possibly operated while one (1) of the four (4) instrument channels deviated from TS 3.2.g.6. Troubleshooting revealed the component in instrument channel 944B that caused the setpoint deviation. That component was replaced with an exact spare, and the instrument channel was retested and documented to be back in compliance with TS 3.2.g.6. In accordance with TS 6.6.c(4), permission from the Reactor Facility Director was obtained prior to the reactor returning to operation later on 10/11/21. Currently, MURR is operating at 10 MW. A detailed event report will follow within 14 days as required by MURR TS 6.6.c(3). |
| Where | |
|---|---|
| University of Missouri-Columbia Columbia, Missouri (NRC Region 0) | |
| License number: | R-103 |
| Reporting | |
| Non | |
| Time - Person (Reporting Time:+32.2 h1.342 days <br />0.192 weeks <br />0.0441 months <br />) | |
| Opened: | Bruce Meffert 13:12 Oct 12, 2021 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Oct 12, 2021 |
| 55516 - NRC Website
Loading map... | |
University of Missouri-Columbia with Non | |
WEEKMONTHYEARENS 573822024-10-14T19:00:00014 October 2024 19:00:00
[Table view]Non Noncompliance with Technical Specification ENS 571802024-06-17T05:00:00017 June 2024 05:00:00 Non Noncompliance with Technical Specification ENS 571252024-05-10T05:00:00010 May 2024 05:00:00 Non Technical Specification Violation ENS 565342023-05-23T13:45:00023 May 2023 13:45:00 Non Technical Specification Violation ENS 562962022-09-22T18:00:00022 September 2022 18:00:00 Non Technical Specification Violation ENS 555832021-11-15T06:00:00015 November 2021 06:00:00 Non Abnormal Occurrence ENS 555682021-11-08T06:00:0008 November 2021 06:00:00 Non Technical Specification Violation ENS 555162021-10-11T05:00:00011 October 2021 05:00:00 Non One Primary Coolant LOW Pressure Instrument Channel Scram Setpoint Found Below Technical Specification Required Minimum 2024-06-17T05:00:00 | |