ENS 54325
From kanterella
Jump to navigation
Jump to search
ENS Event | |
---|---|
17:00 Oct 11, 2019 | |
Title | Technical Specification Required Shutdown Initiated |
Event Description | At 1300 EDT, a Technical Specification required shutdown was initiated at Calvert Cliffs Unit 1. Technical Specification Action 3.1.4.C (Restore Control Element Assembly [CEA] alignment) was entered on 10/11/2019 at 1100 EDT, with a Required Action to reduce thermal power to less than 70 percent Rated Thermal Power and restore CEA alignment within 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br />. This Required Action was not completed within the Completion Time; therefore, a Technical Specification required shutdown was initiated, and this event is being reported as a four-hour, non-emergency notification per 10 CFR 50.72(b)(2)(i).
At 1345 EDT, CEA alignment was restored and Technical Specification 3.1.4 (Control Element Assembly Alignment) was met. Reactor Power is being stabilized. There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified. |
Where | |
---|---|
Calvert Cliffs Maryland (NRC Region 1) | |
Reporting | |
10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown | |
Time - Person (Reporting Time:+-2.63 h-0.11 days <br />-0.0157 weeks <br />-0.0036 months <br />) | |
Opened: | Michael Saul 14:22 Oct 11, 2019 |
NRC Officer: | Donald Norwood |
Last Updated: | Oct 11, 2019 |
54325 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 54325\u003C/a\u003E - \u003Ca href=\"/Calvert_Cliffs\" title=\"Calvert Cliffs\"\u003ECalvert Cliffs\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003ETechnical Specification Required Shutdown Initiated\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 54325 - Calvert Cliffs\n","link":"","lat":38.434263888888886,"lon":-76.44219722222222,"icon":"/w/images/b/be/Constellation_icon.png"}],"imageoverlays":null} | |
Unit 1 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (96 %) |
After | Power Operation (30 %) |
WEEKMONTHYEARENS 543252019-10-11T17:00:00011 October 2019 17:00:00
[Table view]10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Technical Specification Required Shutdown Initiated ENS 503072014-07-25T03:15:00025 July 2014 03:15:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Technical Specification Required Shutdown Due to Reactor Coolant System Pressure Boundary Leakage ENS 493232013-09-05T17:14:0005 September 2013 17:14:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Failure to Align Control Element Assembly During Testing ENS 487632013-02-17T18:45:00017 February 2013 18:45:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Pressure Boundary Leakage Discovered During Containment Walkdown ENS 481832012-08-12T16:34:00012 August 2012 16:34:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Technical Specification Shutdown Due to Fully Inserted Control Rod While Operating ENS 481242012-07-21T16:10:00021 July 2012 16:10:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Technical Specification Required Shutdown Due to Rcs Pressure Boundary Instrument Line Leakage ENS 481162012-07-17T04:00:00017 July 2012 04:00:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Technical Specification Required Shutdown Due to Small Rcs Pressure Boundary Instrument Line Leak ENS 473162011-10-03T14:35:0003 October 2011 14:35:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown, 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Technical Specification (Ts) Required Shutdown Due to Both 'A' Train Edg'S Inoperable ENS 424842006-04-09T03:42:0009 April 2006 03:42:00 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Control Element Assembly Stuck During Physics Testing 2019-10-11T17:00:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_54325&oldid=2508141"