ENS 54145
ENS Event | |
|---|---|
15:26 Jul 3, 2019 | |
| Title | Offsite Notification Due to Radio Transmitter Out of Service |
| Event Description | At 1026 CDT on July 3, 2019, the National Weather Service notified the South Texas Project (STP) that the Bay City NOAA radio transmitter was out of service. This affects the tone alert radios used to notify the public in the event of an emergency condition.
This condition impacts the ability to readily notify a portion of the Emergency Planning Zone (EPZ) population for the STP Electric Generating Station. The loss of the alert radio system meets the reporting criterion for 10 CFR 50.72(b)(3)(xiii). The Matagorda County alert sirens, which are also part of the Public Prompt Notification System, remain operable. Compensatory measures have been verified to be available should the Prompt Notification System be needed. These measures consist of a reverse 911 system available from Matagorda County as well as local law enforcement personnel who would perform route alerting for the affected areas of the EPZ. The event has been entered into the Corrective Action Program and the NRC Resident Inspector has been notified. A return to service time for the radio transmitter is not currently available. Matagorda County was also notified by the National Weather Service and STP. This meets the reporting requirement for notification of an offsite agency, 10 CFR 50.72(b)(2)(xi).
At 1321 CDT, the National Weather Service communication tower was returned to service. South Texas Project verified that the automatic notification radios have been returned to service. The licensee has notified the NRC Resident Inspector. Notified R4DO (Haire). |
| Where | |
|---|---|
| South Texas Texas (NRC Region 4) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
| Time - Person (Reporting Time:+-0.03 h-0.00125 days <br />-1.785714e-4 weeks <br />-4.1094e-5 months <br />) | |
| Opened: | Robert Tatro 15:24 Jul 3, 2019 |
| NRC Officer: | Andrew Waugh |
| Last Updated: | Jul 3, 2019 |
| 54145 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
South Texas | |
WEEKMONTHYEARENS 579862025-10-15T04:05:00015 October 2025 04:05:00
[Table view]10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 572372024-07-24T12:02:00024 July 2024 12:02:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Notification of Unusual Event Due to Loss of Offsite Power ENS 572012024-06-30T17:22:00030 June 2024 17:22:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 564392023-03-30T06:03:00030 March 2023 06:03:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to ON-SITE Fatality ENS 559182022-05-25T18:54:00025 May 2022 18:54:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification for Inadvertent Discharge of Halon ENS 550532020-12-30T21:50:00030 December 2020 21:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Inadvertent Emergency Siren Activation ENS 547142020-05-14T21:10:00014 May 2020 21:10:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification for Hydraulic Oil Release ENS 545872020-03-17T20:58:00017 March 2020 20:58:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Notification to Other Government Agency ENS 545612020-03-04T13:18:0004 March 2020 13:18:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release ENS 545292020-02-17T23:17:00017 February 2020 23:17:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Notification to Other Government Agency ENS 542842019-09-18T12:50:00018 September 2019 12:50:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Communication with Emergency Operations Facility ENS 541452019-07-03T15:26:0003 July 2019 15:26:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Offsite Notification Due to Radio Transmitter Out of Service ENS 540972019-06-01T21:18:0001 June 2019 21:18:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Gasoline Leakage to Site Drainage System ENS 536562018-10-09T05:00:0009 October 2018 05:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Unplanned Loss of Emergency Response Equipment ENS 534052018-05-17T03:02:00017 May 2018 03:02:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of Fires in the Owner Controlled Area ENS 531412018-01-01T16:15:0001 January 2018 16:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Emergency Notification Siren Inadvertent Actuation ENS 531182017-12-12T23:57:00012 December 2017 23:57:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Unplanned Loss of Emergency Response Equipment ENS 531162017-12-12T21:19:00012 December 2017 21:19:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Inadvertent Actuation of Emergency Notification Siren ENS 529112017-08-17T19:42:00017 August 2017 19:42:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Non Work Related Onsite Fatality ENS 527752017-05-30T14:29:00030 May 2017 14:29:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Operations Facility Integrated Computer System Data for Planned Maintenance ENS 527332017-05-05T02:03:0005 May 2017 02:03:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Miscommunication During On-The-Job Training ENS 527162017-04-29T21:23:00029 April 2017 21:23:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Small Grass Fire in Owner Controlled Area ENS 521422016-08-01T20:18:0001 August 2016 20:18:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Unintentional Release of Halon ENS 521062016-07-13T16:00:00013 July 2016 16:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Exercise Press Releases Aired on Radio as an Actual Event ENS 519642016-05-28T01:46:00028 May 2016 01:46:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to an Inadvertent Actuation of One Emergency Siren ENS 517872016-03-14T07:47:00014 March 2016 07:47:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Inadvertent Actuation of Offsite Emergency Notification Siren ENS 515362015-11-13T12:39:00013 November 2015 12:39:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notification of Unusual Event Due to Unidentified Rcs Leakage Greater than 10 Gpm ENS 513392015-08-23T18:00:00023 August 2015 18:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Grass Fire in Owner Controlled Area ENS 511152015-06-01T15:26:0001 June 2015 15:26:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Unit 2 Ventilation Radiation Monitor Operability ENS 510732015-05-15T22:53:00015 May 2015 22:53:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Siren Actuation ENS 507162015-01-05T23:45:0005 January 2015 23:45:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Death of Employee ENS 484482012-10-27T19:15:00027 October 2012 19:15:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Offsite Communications ENS 473622011-10-20T21:50:00020 October 2011 21:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to the Offsite Fatality of an Employee ENS 465882011-02-02T14:30:0002 February 2011 14:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Partial Loss of Prompt Notification System (Pns) Emergency Sirens Due to a Loss of Power ENS 463872010-11-03T15:21:0003 November 2010 15:21:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unusual Event Declared Due to an Explosion in the Protected Area Which Affects Normal Operations ENS 452622009-08-13T20:41:00013 August 2009 20:41:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to a Grass Fire in the Owner Controlled Area ENS 436122007-09-01T21:58:0001 September 2007 21:58:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Related to Fatality ENS 435952007-08-25T12:30:00025 August 2007 12:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Erds System and Portions of Plant Computer Out of Service for Planned Maintenance Outage ENS 430862007-01-10T18:35:00010 January 2007 18:35:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Offsite Landline Communications Capability Due to Cut Fiber Optic Cable ENS 427572006-08-08T20:43:0008 August 2006 20:43:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Emergency Notification Siren Activation ENS 425792006-05-16T14:45:00016 May 2006 14:45:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Disruption of Incoming and Outgoing Telephone Communciation Capability ENS 423222006-02-08T22:30:0008 February 2006 22:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 415052005-03-19T14:27:00019 March 2005 14:27:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Injured Contract Employee ENS 413942005-02-10T02:20:00010 February 2005 02:20:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Press Release for Plant Shutdown ENS 406572004-04-08T14:44:0008 April 2004 14:44:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of a Fatality 2025-10-15T04:05:00 | |