| Title | Manual Initiation of the Auxiliary Feedwater System in Response to a Loss of Feedwater |
| Event Description | At 1324 CDT, on 4/22/2019, with unit 2 in Mode 3 at 0 percent power, an intentional manual initiation of the Auxiliary Feedwater System occurred in response to a loss of feedwater condition. The loss of feedwater condition occurred after the non-safety related Startup Feedwater Pump was secured due to high bearing temperatures. The A Train Auxiliary Feedwater Pump was started per procedure. The Auxiliary Feedwater System started and operated as designed following intentional manual initiation.
This event is being reported in accordance with 10 CFR 50.72(b)(3)(iv)(A) as an event that results in a valid actuation of the Auxiliary Feedwater System. There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified. |
| Where | |
|---|---|
| Byron Illinois (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(iv)(A), System Actuation | |
| Time - Person (Reporting Time:+2.28 h0.095 days <br />0.0136 weeks <br />0.00312 months <br />) | |
| Opened: | Brian Lewin 20:41 Apr 22, 2019 |
| NRC Officer: | Jeff Herrera |
| Last Updated: | Apr 22, 2019 |
| 54020 - NRC Website
Loading map... | |
Unit 2 | |
|---|---|
| Reactor critical | Not Critical |
| Scram | No |
| Before | Hot Standby (0 %) |
| After | Hot Standby (0 %) |
WEEKMONTHYEARENS 540202019-04-22T18:24:00022 April 2019 18:24:00
[Table view]10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Initiation of the Auxiliary Feedwater System in Response to a Loss of Feedwater ENS 534912018-07-06T05:00:0006 July 2018 05:00:00 10 CFR 50.72(b)(3)(iv)(A), System Actuation Transformer Failure Causes Loss of Offsite Power to Unit 2 ENS 522952016-10-12T18:38:00012 October 2016 18:38:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip Due to Spurious Feedwater Isolation ENS 508592015-03-03T17:01:0003 March 2015 17:01:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Automatic Reactor Trip Due to Main Power Transformer Bushing Short ENS 499192014-03-15T16:02:00015 March 2014 16:02:00 10 CFR 50.72(b)(3)(iv)(A), System Actuation Momentary Loss of Shutdown Cooling Due to a Loss of Offsite Power ENS 488382013-03-21T00:51:00021 March 2013 00:51:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Reactor Trip Due to Loss of Generator Stator Cooling Water ENS 477082012-02-28T23:31:00028 February 2012 23:31:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Unusual Event Due to Loss of Offsite Power ENS 476442012-02-06T23:19:0006 February 2012 23:19:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Manual Rps Actuation Due to Turbine Trip ENS 476242012-01-30T16:01:00030 January 2012 16:01:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration, 10 CFR 50.72(b)(3)(iv)(A), System Actuation, 10 CFR 50.72(b)(2)(i), Tech Spec Required Shutdown Unusual Event Due to Loss of Offsite Power Greater than 15 Minutes ENS 458672010-04-19T10:03:00019 April 2010 10:03:00 10 CFR 50.72(b)(3)(iv)(A), System Actuation Rps and Afw Actuation Signals While Shutdown in Mode 4 ENS 420632005-10-19T05:57:00019 October 2005 05:57:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(iv)(A), System Actuation Automatic Reactor Trip Due to Low 2 Steam Generator Water Level 2019-04-22T18:24:00 | |