Title | Report of Degraded Condition Due to Leaking Valve |
Event Description | On 3/26/2019 at 1030 CDT Engineering evaluation determined that Traversing lncore Probe (TIP) System test results related to Leak Rate Testing of 2-CKV-76-653, TIP Purge Header Check Valve, during the Unit 2 Refueling Outage resulted in a reportable condition. On 3/24/2019 at 1558 CDT, Leak Rate Testing identified a [local leak rate test] LLRT failure of 2-CKV-76-653. The gross leakage Leak Rate value exceeded the Technical Specification allowable value for Type C valves of less than 0.6 [allowable leakage] La.
This constitutes an 8-hour NRC notification in accordance with 10 CFR 50.72(b)(3)(ii)(A) - Any event or condition that results in the condition of the nuclear power plant, including its principal safety barriers, being seriously degraded. There was no impact on the health and safety of the public or plant personnel. The NRC Resident Inspector has been notified. The short-term corrective actions include repairing the valve such that it passes the test. The valve needs to be repaired before the unit can change modes. |
Where | |
---|---|
Browns Ferry Alabama (NRC Region 2) | |
Reporting | |
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
Time - Person (Reporting Time:+0.63 h0.0263 days <br />0.00375 weeks <br />8.62974e-4 months <br />) | |
Opened: | Matthew Slouka 16:08 Mar 26, 2019 |
NRC Officer: | Jeffrey Whited |
Last Updated: | Mar 26, 2019 |
53959 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 53959\u003C/a\u003E - \u003Ca href=\"/Browns_Ferry\" title=\"Browns Ferry\"\u003EBrowns Ferry\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EReport of Degraded Condition Due to Leaking Valve\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 53959 - Browns Ferry\n","link":"","lat":34.70418333333333,"lon":-87.11844722222222,"icon":"/w/images/c/ce/Tennessee_Valley_Authority_icon.png"}],"imageoverlays":null} | |
WEEKMONTHYEARENS 564112023-03-15T03:57:00015 March 2023 03:57:00
[Table view]10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Reactor Coolant System (RCS) Boundary Degraded Condition ENS 563712023-02-18T10:39:00018 February 2023 10:39:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition ENS 562572022-12-03T16:00:0003 December 2022 16:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Discovered on Shutdown Cooling Test Line ENS 557062022-01-16T05:20:00016 January 2022 05:20:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Discovered on Shutdown Cooling Test Line ENS 539592019-03-26T15:30:00026 March 2019 15:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Report of Degraded Condition Due to Leaking Valve ENS 451072009-05-31T18:30:00031 May 2009 18:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Due to Discovery of Pressure Boundary Leakage ENS 446802008-11-23T18:00:00023 November 2008 18:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Pressure Boundary Leak ENS 436592007-09-22T17:45:00022 September 2007 17:45:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Pressure Boundary Leakage Discovered During Drywell Inspection 2023-03-15T03:57:00 | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_53959&oldid=1377363"