ENS 53749
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
05:00 Nov 21, 2018 | |
| Title | Degraded Condition Identified During Surface Inspection of Reactor Head Nozzle Penetration |
| Event Description | On November 21, 2018, during an extent of condition review, after completion of ultrasonic testing, further interrogation of reactor vessel closure head (RVCH) penetration 36 was performed using eddy current testing. The testing detected three repairable indications. No indication of boric acid leakage was identified at this location during the bare metal visual inspection. Extent of condition review is complete on all RVCH penetrations.
The plant was in cold shutdown at 0 percent power and in Mode 6 for a refueling outage at the time of discovery. Repair actions will be completed prior to plant startup from the outage. This condition has no impact to the health and safety of the public. This report is being made in accordance with 10 CFR 50.72(b)(3)(ii)(A) for degradation of a principal safety barrier. The licensee notified the NRC Senior Resident Inspector. |
| Where | |
|---|---|
| Palisades Michigan (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
| Time - Person (Reporting Time:+12.45 h0.519 days <br />0.0741 weeks <br />0.0171 months <br />) | |
| Opened: | James Byrd 17:27 Nov 21, 2018 |
| NRC Officer: | Ossy Font |
| Last Updated: | Nov 21, 2018 |
| 53749 - NRC Website
Loading map... | |
WEEKMONTHYEARENS 548972020-09-11T23:30:00011 September 2020 23:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | Degraded Condition ENS 537492018-11-21T05:00:00021 November 2018 05:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Identified During Surface Inspection of Reactor Head Nozzle Penetration ENS 537342018-11-11T04:00:00011 November 2018 04:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Due to Indication During Ultrasonic Inspection of Reactor Head Nozzle Penetration ENS 537332018-11-10T05:00:00010 November 2018 05:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Boric Acid Identified on Reactor Vessel Head Penetration ENS 527222017-05-02T13:28:0002 May 2017 13:28:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Failed Ultrasonic Testing of Weld ENS 497962014-02-05T18:00:0005 February 2014 18:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Discovered on Pressurizer Nozzle Weld During Testing ENS 497732014-01-29T14:00:00029 January 2014 14:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Indications Identified on Control Rod Drive Mechanism Housings ENS 481822012-08-12T08:18:00012 August 2012 08:18:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Reported Based on the Discovery of Pressure Boundary Leakage ENS 411282004-10-16T21:30:00016 October 2004 21:30:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Reactor Vessel Head Nozzle Cracking 2020-09-11T23:30:00 [Table view] | |
Retrieved from "https://kanterella.com/w/index.php?title=ENS_53749&oldid=2508276"